Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Unfallchirurg ; 121(2): 152-158, 2018 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-27933356

RESUMO

The upper limb is one of the most frequently injured body regions in equestrian sports, but it is unclear which injuries are involved, and there are no data on the associated accident mechanism. The present study is aimed at evaluating the accident mechanisms, injuries of the upper limbs, and the circumstances of the accident in equestrian sports. We included 218 patients who were all treated between 2006 and 2014 at the level I trauma center at the Medical University in Hannover because of equestrian-related accidents. The most frequent injuries were fractures and bruising in the shoulder area, fingers and hands, and the distal area of the lower arm, which were mostly caused by the horse kicking. To prevent hand injuries it is recommended that gloves are worn; the potential introduction of strengthened materials could protect the bones from severe bumping. Training in falling techniques to prevent serious injury to the upper limb would be useful. In general, primary prevention in equestrian sports should be extended to counteract the increasing neglect of protective equipment.


Assuntos
Traumatismos do Braço/prevenção & controle , Traumatismos do Braço/cirurgia , Traumatismos em Atletas/prevenção & controle , Traumatismos em Atletas/cirurgia , Cavalos , Acidentes por Quedas/prevenção & controle , Animais , Traumatismos em Atletas/diagnóstico , Traumatismos dos Dedos/prevenção & controle , Traumatismos dos Dedos/cirurgia , Fraturas Ósseas/prevenção & controle , Fraturas Ósseas/cirurgia , Traumatismos da Mão/prevenção & controle , Traumatismos da Mão/cirurgia , Humanos , Equipamento de Proteção Individual , Roupa de Proteção , Fatores de Risco
2.
Science ; 197(4307): 986-9, 1977 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-17784134

RESUMO

Detailed chemical maps of the lunar surface have been constructed by applying a new weighted-filter imaging technique to Apollo 15 and Apollo 16 x-ray fluorescence data. The data quality improvement is amply demonstrated by (i) modes in the frequency distribution, representing highland and mare soil suites, which are not evident before data filtering and (ii) numerous examples of chemical variations which are correlated with small-scale (about 15 kilometer) lunar topographic features.

3.
J Heart Lung Transplant ; 19(9): 834-9, 2000 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11008071

RESUMO

BACKGROUND: Extracorporeal membrane oxygenation (ECMO) is widely used for postcardiotomy cardiogenic shock in children. However, the efficacy of ECMO for early post-heart transplant graft failure in infants has not been reported. Our aims were to determine: (1) the utility of ECMO in infants with severe donor-heart dysfunction, (2) predictors for requiring ECMO, and (3) the long-term outcome of surviving ECMO patients. METHODS: All infants (age < 6 months at listing) undergoing heart transplantation were reviewed. Diagnostic categories were hypoplastic left heart syndrome (HLHS) and non-HLHS (complex congenital heart disease and cardiomyopathies). Continuous and categorical comparisons were by Wilcoxon's rank sum test and Fisher's exact test respectively. RESULTS: 14 (12 HLHS, 2 non-HLHS) of 63 (46 HLHS, 17 non-HLHS) infants were placed on ECMO. Ten patients (71%) were successfully weaned from ECMO and 8 (57%) were discharged alive. All ECMO hospital survivors remain alive (mean follow-up 36.2 +/- 21.4 months, range 13.1-77.6 months). Mean duration of ECMO support was 68 hours in weaned patients vs 144 hours (p = 0.19) in nonweaned patients, and 64 hours in survivors vs 123 hours (p = 0.35) in nonsurvivors. ECMO deaths were due to sepsis (n = 3), intractable pulmonary hypertension (n = 2), and intracranial bleed (n = 1). Neurologic deficits occurred in 2 survivors. Median ICU and hospital stays for ECMO survivors were 29 and 33 days vs 7 (p = 0.0003) and 9 (p = 0.0004) days for non-ECMO patients. Age listed, age transplanted, wait time, body weight, donor/recipient weight ratio, total ischemia time, and diagnosis did not predict the need for ECMO. CONCLUSIONS: (1) ECMO is useful for post-heart transplant circulatory support in infants with early graft failure. (2) All survivors were weaned in fewer than 4 days. (3) Three-year survival of ECMO hospital survivors has been high, but neurologic complications are prevalent.


Assuntos
Cardiomiopatias/cirurgia , Oxigenação por Membrana Extracorpórea , Cardiopatias Congênitas/cirurgia , Transplante de Coração , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Complicações Pós-Operatórias/terapia , Ponte Cardiopulmonar , Oxigenação por Membrana Extracorpórea/efeitos adversos , Humanos , Lactente , Estudos Retrospectivos , Fatores de Risco
4.
Ann Thorac Surg ; 55(6): 1534-9, 1993 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-8512408

RESUMO

The impedance catheter allows continuous measurement of ventricular volume. External influences have been described as causing parallel shifts in impedance-measured volumes; however, factors affecting impedance measurements in a nonparallel manner have not been fully characterized. Accordingly, an impedance catheter was placed inside a latex balloon into which known volumes of normal saline solution were injected. Conductive and nonconductive materials were individually placed within the balloon. Impedance was measured with materials touching (T) or not touching (NT) the catheter. Impedance-measured volumes were plotted versus actual volumes. Compared with the line of identity (LID), a statistical difference (p < 0.05) was found in the slopes in the presence of metallic objects only. These included a pacing lead (T, NT) (mT = 1.32m mNT = 1.29 versus mLID = 1.00), titanium (T) (mT = 1.68 versus mLID = 1.00), and aluminum (NT) (mNT = 0.72 versus mLID = 1.00). These changes in slope indicate nonparallel effects on impedance that confound the ability of the impedance catheter to determine volumes in vitro. These observations imply that serial calibration of both the slope constant (alpha) and the intercept (parallel conductance) of impedance may be necessary for in vivo measurements of ventricular volume based on impedance in the presence of metallic objects.


Assuntos
Cateterismo Cardíaco/instrumentação , Volume Cardíaco/fisiologia , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Alumínio , Condutividade Elétrica , Impedância Elétrica , Eletrodos , Humanos , Técnicas In Vitro , Processamento de Sinais Assistido por Computador , Cloreto de Sódio , Titânio
5.
Ann Thorac Surg ; 52(5): 1052-7, 1991 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-1953123

RESUMO

Although the automatic implantable cardioverter defibrillator (AICD) is effective against malignant ventricular arrhythmias, the effects of AICD patches on left ventricular diastolic properties have not been defined. Accordingly, extrapericardial (group E, n = 5) or intrapericardial (group I, n = 6) AICD patches were implanted through a median sternotomy in 11 anesthetized pigs. Six weeks later, using a left thoracotomy, the hearts were arrested with hypothermic cardioplegia. A balloon catheter was inserted into the left ventricle through the aortic root, and pressure-volume curves were measured before and after sequential removal of patches and pericardium. A dense intrapericardial fibrotic reaction in group I was not present in group E. Normalized left ventricular filling volumes in group E were significantly larger at pressures of 5.1 to 10, 15.1 to 20, and 20.1 to 28 mm Hg compared with group I (p less than 0.05). We conclude that intrapericardial AICD patches adversely affect left ventricular diastolic pressure-volume relations and recommend that AICD patches be placed in the extrapericardial location clinically whenever possible.


Assuntos
Diástole/fisiologia , Cardioversão Elétrica/instrumentação , Próteses e Implantes , Função Ventricular Esquerda/fisiologia , Animais , Cateterismo Cardíaco , Eletrodos Implantados , Fibrose , Pericárdio/patologia , Próteses e Implantes/efeitos adversos , Suínos
6.
Ann Thorac Surg ; 72(1): 251-3, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11465189

RESUMO

Mitral valve replacement in small children imposes significant clinical difficulties because of the relatively small mechanical prosthetic valves required and the need for lifelong anticoagulation therapy. A child weighing 10.4 kg presented with thrombosis of her 19-mm mechanical mitral prosthesis 4 weeks after implantation despite appropriate oral anticoagulation therapy. An emergency mitral valve replacement with a pulmonary autograft was successfully performed with encouraging short-term results.


Assuntos
Emergências , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/cirurgia , Complicações Pós-Operatórias/cirurgia , Valva Pulmonar/transplante , Trombose/cirurgia , Falha de Tratamento , Feminino , Humanos , Lactente , Valva Mitral/cirurgia , Reoperação , Técnicas de Sutura
7.
Ann Thorac Surg ; 56(1): 46-53, 1993 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-8328875

RESUMO

Laser myocardial revascularization has been shown to reduce mortality and infarct size after left anterior descending coronary artery (LAD) ligation in dogs. It has not been shown to improve myocardial contractility in acute ischemia. In this study a holmium-yttrium-aluminum garnet laser (wavelength, 2.14 microns) was used to create nontransmural myocardial channels from the endocardial surface in the ischemic regions of the canine left ventricle. Twelve mongrel dogs (6 controls, 6 laser myocardial revascularizations) underwent 90 minutes of LAD ligation followed by 6 hours of reperfusion. The ischemic region was determined by methylene blue injection during brief LAD occlusion. Laser myocardial revascularization averaged three channels per square centimeter in the ischemic region created using 12 J/channel (600 mJ/pulse, 10 Hz) before LAD ligation. Contractility was assessed from regional preload recruitable stroke work (RPRSW), using pairs of segment length ultrasonic transducers in the ischemic and the nonischemic regions. Two-dimensional echocardiography corroborated with segmental length findings. In control dogs, the ischemic region was dyskinetic during LAD ligation and reperfusion. Dyskinesis of the ischemic region during systole produced negative values for regional stroke work, and RPRSW was considered zero. In 4 of 6 laser-revascularized dogs, RPRSW remained positive in the ischemic region. Two dogs had intermittent dyskinesis. The difference between laser-revascularized and control dogs in ischemic region RPRSW was significant (p < 0.01 by Fischer's exact test).(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Endocárdio/cirurgia , Terapia a Laser , Isquemia Miocárdica/cirurgia , Revascularização Miocárdica , Doença Aguda , Animais , Cães , Eletrocardiografia , Hemodinâmica , Terapia a Laser/métodos , Isquemia Miocárdica/fisiopatologia , Isquemia Miocárdica/prevenção & controle , Revascularização Miocárdica/métodos
8.
Ann Thorac Surg ; 62(4): 968-74; discussion 974-5, 1996 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-8823074

RESUMO

BACKGROUND: We sought to determine whether low diffusion capacity of the lung to carbon monoxide (DLCO) is a predictor of high postoperative mortality and morbidity after major pulmonary resection and whether major pulmonary resection in patients with low DLCO results in substantial long-term morbidity. METHODS: Sixty-two major pulmonary resections were performed in 61 patients with low DLCO (DLCO < or = 60% predicted for pneumonectomy or bilobectomy; < or = 50% predicted for lobectomy). Contemporaneously, 262 other patients underwent 263 major pulmonary resections (group II). Long-term morbidity was assessed in subsets of patients with low (n = 24) and high (n = 22; DLCO > 60% predicted) DLCO. RESULTS: The hospital mortality rates were equivalent (4.8% low DLCO versus 4.9% group II), whereas respiratory complications were more frequent in patients with low DLCO (18% versus 9.5%; p = 0.05). In the subgroup analyses, patients with low DLCO had more hospitalizations for respiratory compromise and worse median dyspnea scores. Analysis of patients with substantial dyspnea revealed an association with extended pulmonary resection and postoperative radiation therapy in patients with low DLCO. CONCLUSIONS: Patients with low DLCO underwent major pulmonary resection with a low mortality rate and an acceptable, but increased, respiratory complication rate. Long-term respiratory morbidity was increased in patients with low DLCO; however, the extent of pulmonary resection and the use of postoperative radiation therapy may have contributed to the development of dyspnea in these patients.


Assuntos
Pneumonectomia/efeitos adversos , Complicações Pós-Operatórias , Capacidade de Difusão Pulmonar , Idoso , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Pneumonectomia/mortalidade , Fatores de Risco , Capacidade Vital
9.
Ann Thorac Surg ; 71(2): 482-7; discussion 487-8, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11235694

RESUMO

BACKGROUND: Homografts are implanted in the right ventricular outflow tract (RVOT) of children, with the knowledge that reoperation might be required. We reviewed 14 years of homograft RVOT reconstruction to assess the feasibility of homograft replacement and to determine risk factors for homograft survival. METHODS: From February 1985 through March 1999, 223 children (age 5 days to 16.9 years) underwent primary RVOT reconstruction with an aortic or pulmonary homograft. Of these, 35 patients underwent homograft explant at the implanting hospital with insertion of a second homograft from 2 months to 13.3 years after the first implantation. The primary operation and reoperation patient groups were compared with regard to incidence of early death, late death, homograft-related intervention without explant, and homograft explant. RESULTS: Actuarial survival and event-free curves for initial and replacement homografts were not significantly different. Univariable analysis was performed for the following risk factors: weight (p < 0.0001), age (p < 0.003), homograft diameter (p < 0.0001), homograft type (p < 0.01), surgery date (not significant [NS]), gender (NS), Blood Group match (NS), and type of distal anastomosis (NS). Multivariable analysis of significant univariable risks revealed small homograft diameter to be a significant risk factor (p < 0.001) for replacement. CONCLUSIONS: The RVOT homografts eventually require replacement. Patient and homograft survival for replacement homografts is similar to primary homografts. Reoperative homograft RVOT reconstruction is possible, with reasonably low morbidity and mortality.


Assuntos
Valva Aórtica/transplante , Cardiopatias Congênitas/cirurgia , Valva Pulmonar/transplante , Obstrução do Fluxo Ventricular Externo/cirurgia , Adolescente , Criança , Pré-Escolar , Criopreservação , Estudos de Viabilidade , Feminino , Sobrevivência de Enxerto , Humanos , Lactente , Recém-Nascido , Masculino , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/cirurgia , Reoperação , Taxa de Sobrevida , Transplante Homólogo , Obstrução do Fluxo Ventricular Externo/mortalidade
11.
Curr Genet ; 21(4-5): 265-8, 1992 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-1525852

RESUMO

The enzyme beta-lactamase, a secretory protein that is located in the Escherichia coli periplasmic space, can be highly expressed in Saccharomyces cerevisiae. Although the protein can cross eukaryotic membranes, it is only inefficiently secreted by yeast. To determine whether the lack of secretion in yeast is due to the nature of the bacterial signal sequence, it was replaced with the signal peptide of yeast invertase. The presence of the invertase signal peptide led to beta-lactamase secretion of up to 75%. The results indicate that the bacterial signal peptide is not functional in yeast, although cleavage can take place at the authentic processing site. The mature enzyme does not interfere with the yeast secretion pathway.


Assuntos
Glicosídeo Hidrolases/química , Sinais Direcionadores de Proteínas/metabolismo , Saccharomyces cerevisiae/fisiologia , beta-Lactamases/metabolismo , Sequência de Aminoácidos , Sequência de Bases , Escherichia coli/enzimologia , Glicosídeo Hidrolases/genética , Dados de Sequência Molecular , Plasmídeos , Proteínas Recombinantes de Fusão/metabolismo , beta-Frutofuranosidase , beta-Lactamases/química , beta-Lactamases/genética
12.
Mol Gen Genet ; 215(3): 401-6, 1989 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-2651889

RESUMO

Intercompartmental transport of secreted proteins in yeast was analysed using invertase mutants. Deletions and insertions at the BamHI (position + 787) or the Asp718 (position + 1159) sites of the SUC2 gene led to mutant proteins with different behaviour regarding secretion, localization and enzyme activity. The deletion mutants showed accumulation of core glycosylated material in the endoplasmic reticulum (ER) a decrease of secreted protein by 5%-30% and loss of enzyme activity. The secreted material was localized in the culture medium and not - as is normal for invertase - in the cell wall. No delay in transport from the Golgi to the cell surface was observed, indicating that the rate-limiting step for secretion is at the ER-Golgi stage. Two insertion mutants, pIPA and pIPB, retained enzyme activity. Mutant pIPB showed 10% secretion, while 60%-70% secretion was observed for pIPA. While the non-secreted material accumulated in the ER, the secreted material was present in the cell wall. The results suggest that the presence of structures incompatible with secretion leads to ER accumulation of mutated invertase.


Assuntos
Glicosídeo Hidrolases/metabolismo , Saccharomyces cerevisiae/enzimologia , Sequência de Aminoácidos , Sequência de Bases , Transporte Biológico Ativo , Deleção Cromossômica , DNA Fúngico/genética , Retículo Endoplasmático/enzimologia , Genes Fúngicos , Glicosídeo Hidrolases/genética , Dados de Sequência Molecular , Mutação , Saccharomyces cerevisiae/genética , beta-Frutofuranosidase
13.
Circulation ; 88(5 Pt 2): II447-51, 1993 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-8222192

RESUMO

BACKGROUND: A thoracoscopic technique was developed for the placement of commercially available implantable cardioverter-defibrillator (ICD) patch leads in sheep. METHODS AND RESULTS: Small ICD patch leads (13.5 cm2, A-67) were placed thoracoscopically in sheep (n = 5) that had survived coronary artery ligation from a previous experiment. The technique used three small incisions in the left chest. After lysis of adhesions, the ICD patch lead was introduced through a mediastinoscope. The ICD patch lead was secured in the extrapericardial position with surgical clips placed in the four corners of the ICD patch lead. After 2 weeks, a median sternotomy was performed, and ICD patch leads were reexamined for positioning. Extensive fibrosis was noted to adhere the ICD patch lead to the pericardium. The surgical clips were found intact in all animals without noticeable migration of patch lead position. There was no mortality related to ICD patch lead placement, and estimated blood loss was less than 30 mL without use of cautery. CONCLUSIONS: Commercially available ICD patch leads may be reliably and safely placed with minimal patch migration in sheep using thoracoscopic techniques.


Assuntos
Desfibriladores Implantáveis , Eletrodos Implantados , Toracoscopia , Animais , Masculino , Pericárdio/cirurgia , Ovinos , Técnicas de Sutura
14.
Pacing Clin Electrophysiol ; 17(6): 1100-6, 1994 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-7521035

RESUMO

Although the elective induction of cardiac arrest for implantable defibrillator insertion under general anesthesia is widely used, the hemodynamics of recovery of arterial blood pressure after cardiac arrest is not well-defined. Accordingly, the time course of recovery of systolic arterial pressure was studied in seven patients during the repetitive induction of ventricular fibrillation (n = 6) or ventricular flutter (n = 1). The mean number of episodes of cardiac arrest was 7 +/- 2, and the mean drop in systolic pressure was 84 +/- 16 mmHg. The mean recovery time for systolic pressure was 10 +/- 6 seconds, the average systolic pressure recovery rate was 13 +/- 14 mmHg/sec, and the mean percent systolic pressure recovery was 94% +/- 9%. A negative logarithmic relation was found to exist between the rate of systolic arterial pressure recovery and the duration of ventricular fibrillation or flutter with a correlation coefficient of 0.68 to 0.97 (P < 0.05) in five of the seven patients. A linear relation between the time for systolic pressure recovery and duration of asystole was also defined. These results are consistent with the view that prolongation of ventricular fibrillation or flutter increases the duration of arterial pressure recovery through a negative effect on left ventricular contractility. Increased understanding of these relations may lead to increased safety of implantable defibrillator insertion.


Assuntos
Pressão Sanguínea , Fibrilação Ventricular/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Estimulação Cardíaca Artificial , Desfibriladores Implantáveis , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
15.
Eur J Biochem ; 184(3): 699-706, 1989 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-2806251

RESUMO

We have cloned and characterized the alpha-amylase gene (AMY1) of the yeast Schwanniomyces occidentalis. A cosmid gene library of S. occidentalis DNA was screened in Saccharomyces cerevisiae for alpha-amylase secretion. The positive clone contained a DNA fragment harbouring an open reading frame of 1536 nucleotides coding for a 512-amino-acid polypeptide with a calculated Mr of 56,500. The deduced amino acid sequence reveals significant similarity to the sequence of the Saccharomycopsis fibuligera and Aspergillus oryzae alpha-amylases. The AMY l gene was found to be expressed from its original promoter in S. cerevisiae, Kluyveromyces lactis and Schizo-saccharomyces pombe leading to an active secreted gene product and thus enabling the different yeast transformants to grow on starch as a sole carbon source.


Assuntos
Ascomicetos/enzimologia , Transformação Genética , Leveduras/enzimologia , alfa-Amilases/genética , Sequência de Aminoácidos , Sequência de Bases , Clonagem Molecular , Expressão Gênica , Dados de Sequência Molecular , alfa-Amilases/análise , alfa-Amilases/metabolismo
16.
Circulation ; 86(5 Suppl): II276-9, 1992 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-1424013

RESUMO

BACKGROUND: Sudden cardiac death (SCD) is common among patients awaiting heart transplantation. Medical management of SCD may fail due to lack of efficacy or adverse side effects. The implantable cardioverter-defibrillator (ICD) may extend patient survival until a donor heart is available. METHODS AND RESULTS: We reviewed 16 patients listed for transplantation between November 1988 and October 1991 who underwent ICD implantation for ventricular arrhythmias refractory to medical management. Mean age was 51.4 +/- 11.4 years (range, 19-66 years), mean ejection fraction was 15.4 +/- 3.0% (range, 10-21%), and underlying cardiomyopathy was ischemic (12 patients), valvular (one patient), or dilated (three patients). There was no mortality from ICD insertion. Fourteen patients were discharged before transplantation, and two patients remained in the hospital until transplantation. Twelve patients underwent transplantation after a mean of 155.7 +/- 113.7 days (range, 3-319) on the transplant list. The ICD delivered shocks for tachyarrhythmia associated with near syncope in 15 of 16 patients. ICD shocks numbered > 10 in five patients, 5-9 in three patients, and 1-4 in seven patients. There was no morbidity or mortality attributed to patch electrode removal. CONCLUSIONS: We conclude that the ICD can be implanted with minimal morbidity in transplant candidates, allowing the patients to be ambulatory and to leave the hospital while awaiting heart transplantation. In patients at risk of SCD, the ICD is an effective electronic bridge to transplantation.


Assuntos
Arritmias Cardíacas/prevenção & controle , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Transplante de Coração , Avaliação da Tecnologia Biomédica , Antiarrítmicos/uso terapêutico , Cardiomiopatias/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cidade de Nova Iorque , Listas de Espera
18.
19.
Appl Opt ; 23(14): 2239, 1984 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-18212983
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA