Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
AJR Am J Roentgenol ; 215(4): 839-842, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32298149

RESUMO

OBJECTIVE. Coronavirus disease (COVID-19) is a global pandemic. Studies in the radiology literature have suggested that CT might be sufficiently sensitive and specific in diagnosing COVID-19 when used in lieu of a reverse transcription-polymerase chain reaction test; however, this suggestion runs counter to current society guidelines. The purpose of this article is to critically review some of the most frequently cited studies on the use of CT for detecting COVID-19. CONCLUSION. To date, the radiology literature on COVID-19 has consisted of limited retrospective studies that do not substantiate the use of CT as a diagnostic test for COVID-19.


Assuntos
Infecções por Coronavirus/diagnóstico por imagem , Pneumonia Viral/diagnóstico por imagem , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Betacoronavirus , COVID-19 , Humanos , Pandemias , SARS-CoV-2
2.
Radiographics ; 39(1): 30-43, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30468629

RESUMO

Aortic stenosis is the most prevalent valvular cardiovascular disease affecting the population over the age of 65 years. Transcatheter aortic valve replacement (TAVR) was developed as a minimally invasive surgical intervention to treat aortic stenosis in patients at high risk for surgical complications. Although the most commonly used approach for placement of a transcatheter aortic valve is in retrograde fashion via a transfemoral approach, narrowed luminal diameters, extensive atherosclerotic disease, or significant tortuosity may limit use of this route. In these patients, alternative methods including subclavian, transaortic, and transapical approaches should be considered. An understanding of these access routes and their respective indications and contraindications allows the radiologist to provide additional preprocedure measurements and images to help guide placement of the valve. ©RSNA, 2018.


Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Artéria Femoral , Coração/diagnóstico por imagem , Próteses Valvulares Cardíacas , Humanos , Tomografia Computadorizada Multidetectores
3.
Radiographics ; 39(5): 1264-1279, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31419188

RESUMO

Video-assisted thoracic surgery (VATS) and robotically assisted surgery are used increasingly for minimally invasive diagnostic and therapeutic resection of pulmonary nodules. Unsuccessful localization of small, impalpable, or deep pulmonary nodules can necessitate conversion from VATS to open thoracotomy. Preoperative localization techniques performed by radiologists have improved the success rates of VATS resection for small and subsolid nodules. Any center at which VATS diagnostic resection of indeterminate pulmonary nodules is performed should be supported by radiologists who offer preoperative nodule localization. Many techniques have been described, including image-guided injection of radioisotopes and radiopaque liquids and placement of metallic wires, coils, and fiducial markers. These markers enable the surgeon to visualize the position of an impalpable nodule intraoperatively. This article provides details on how to perform each percutaneous localization technique, and a group of national experts with established nodule localization programs describe their preferred approaches. Special reference is made to equipment required, optimization of marker placement, prevention of technique-specific complications, and postprocedural treatment. This comprehensive unbiased review provides valuable information for those who are considering implementation or optimization of a nodule localization program according to workflow patterns, surgeon preference, and institutional resources in a particular center. ©RSNA, 2019.


Assuntos
Biópsia Guiada por Imagem/métodos , Neoplasias Pulmonares/cirurgia , Nódulos Pulmonares Múltiplos/cirurgia , Radiografia Intervencionista/métodos , Procedimentos Cirúrgicos Robóticos , Cirurgia Torácica Vídeoassistida , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/diagnóstico por imagem
4.
Proc Natl Acad Sci U S A ; 113(31): 8759-64, 2016 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-27432961

RESUMO

Thoracic aortic aneurysms and dissections (TAAD) represent a substantial cause of morbidity and mortality worldwide. Many individuals presenting with an inherited form of TAAD do not have causal mutations in the set of genes known to underlie disease. Using whole-genome sequencing in two first cousins with TAAD, we identified a missense mutation in the lysyl oxidase (LOX) gene (c.893T > G encoding p.Met298Arg) that cosegregated with disease in the family. Using clustered regularly interspaced short palindromic repeats (CRISPR)/clustered regularly interspaced short palindromic repeats-associated protein-9 nuclease (Cas9) genome engineering tools, we introduced the human mutation into the homologous position in the mouse genome, creating mice that were heterozygous and homozygous for the human allele. Mutant mice that were heterozygous for the human allele displayed disorganized ultrastructural properties of the aortic wall characterized by fragmented elastic lamellae, whereas mice homozygous for the human allele died shortly after parturition from ascending aortic aneurysm and spontaneous hemorrhage. These data suggest that a missense mutation in LOX is associated with aortic disease in humans, likely through insufficient cross-linking of elastin and collagen in the aortic wall. Mutation carriers may be predisposed to vascular diseases because of weakened vessel walls under stress conditions. LOX sequencing for clinical TAAD may identify additional mutation carriers in the future. Additional studies using our mouse model of LOX-associated TAAD have the potential to clarify the mechanism of disease and identify novel therapeutics specific to this genetic cause.


Assuntos
Aneurisma da Aorta Torácica/genética , Dissecção Aórtica/genética , Predisposição Genética para Doença/genética , Mutação com Perda de Função , Proteína-Lisina 6-Oxidase/genética , Adulto , Idoso , Dissecção Aórtica/enzimologia , Animais , Aneurisma da Aorta Torácica/enzimologia , Sequência de Bases , Análise Mutacional de DNA/métodos , Saúde da Família , Feminino , Humanos , Masculino , Camundongos Endogâmicos C57BL , Camundongos Knockout , Pessoa de Meia-Idade , Linhagem , Proteína-Lisina 6-Oxidase/metabolismo
5.
Radiology ; 289(3): 809-813, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30277849

RESUMO

Academic medical centers have long relied on radiology residents to provide after-hours coverage, which means that they essentially function with autonomy. In this approach, attending radiologist review of resident interpretations occurs the following morning, often by subspecialist faculty. In recent years, however, this traditional coverage model in academic radiology departments has been challenged by an alternative model, the 24-hour attending radiologist coverage. Proponents of this new model seek to improve patient care after hours by increasing report accuracy and the speed with which the report is finalized. In this article, we review the traditional and the 24-hour attending radiologist coverage models. We summarize previous studies that indicate that resident overnight error rates are sufficiently low so that changing to an overnight attending model may not necessarily provide a meaningful increase in report accuracy. Whereas some centers completely replaced overnight residents, we note that most centers use a hybrid model, and overnight residents work alongside supervising attending radiologists, much as they do during the day. Even in this hybrid model, universal double reading and subspecialist final review, typical features of the traditional autonomous resident coverage model, are generally sacrificed. Because of this, changing from resident coverage to coverage by an attending radiologist that is 24 hours/day, 7 days/week may actually have detrimental effects to patient safety and quality of care provided. Changing to an overnight attending radiologist model may also have negative effects on the quality of radiology resident training, and it significantly increases cost.


Assuntos
Centros Médicos Acadêmicos/normas , Plantão Médico/normas , Competência Clínica/normas , Internato e Residência/métodos , Corpo Clínico Hospitalar/normas , Serviço Hospitalar de Radiologia/normas , Humanos , Radiologistas/normas , Reprodutibilidade dos Testes , Carga de Trabalho
6.
J Card Surg ; 32(2): 159-161, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28076895

RESUMO

Left ventricular noncompaction (LVNC) may result in systolic left ventricular (LV) failure resulting in the need for heart transplantation. LV assist devices (LVAD) have been used to bridge these patients to transplantation; however, the extensive trabeculations found in these patients predispose them to thromboembolic events and pump thrombosis. We describe a patient with LVNC in whom an aggressive surgical approach was used to debride the LV cavity of trabeculations to successfully implant an LVAD.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Cardiomiopatias/cirurgia , Ventrículos do Coração/cirurgia , Coração Auxiliar , Função Ventricular Esquerda/fisiologia , Adulto , Cardiomiopatias/diagnóstico , Cardiomiopatias/fisiopatologia , Ecocardiografia , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Tomografia Computadorizada por Raios X
8.
J Patient Saf ; 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38506482

RESUMO

OBJECTIVES: Inadequate follow-up of incidental imaging findings (IIFs) can result in poor patient outcomes, patient dissatisfaction, and provider malpractice. At our institution, radiologists flag IIFs during report dictation to trigger electronic health record (EHR) notifications to providers and patients. Nurse coordinators directly contact patients or their primary care physicians (PCPs) regarding IIFs if follow-up is not completed within the recommended time frame. Despite these interventions, many patients and their PCPs remain unaware of IIFs. In an effort to improve awareness of IIFs, we aim to investigate communication of IIFs on inpatient discharge summaries after implementation of our EHR notification system. METHODS: Inpatient records with IIFs from 2018 to 2021 were retrospectively reviewed to determine type of IIFs, follow-up recommendations, and mention of IIFs on discharge summaries. Nurse coordinators spoke to patients and providers to determine their awareness of IIFs. RESULTS: Incidental imaging findings were reported in 51% of discharge summaries (711/1383). When nurse coordinators called patients and PCPs regarding IIFs at the time follow-up was due, the patients and PCPs were aware of 79% of IIFs (1096/1383). CONCLUSIONS: With implementation of EHR notifications to providers regarding IIFs, IIFs were included in 51% of discharge summaries. Lack of inclusion of IIFs on discharge summaries could be related to transitions of care within hospitalization, provider alert fatigue, and many diagnostic testing results to distill. These findings demonstrate the need to improve communication of IIFs, possibly via automating mention of IIFs on discharge summaries, and the need for care coordinators to follow up on IIFs.

9.
Am J Nephrol ; 38(2): 158-67, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23941761

RESUMO

BACKGROUND/AIMS: Cardiovascular disease (CVD) is increased in chronic kidney disease (CKD), and contributed to by the CKD-mineral bone disorder (CKD-MBD). CKD-MBD begins in early CKD and its vascular manifestations begin with vascular stiffness proceeding to increased carotid artery intima-media thickness (cIMT) and vascular calcification (VC). Phosphorus is associated with this progression and is considered a CVD risk factor in CKD. We hypothesized that modifying phosphorus balance with lanthanum carbonate (LaCO3) in early CKD would not produce hypophosphatemia and may affect vascular manifestations of CKD-MBD. METHODS: We randomized 38 subjects with normophosphatemic stage 3 CKD to a fixed dose of LaCO3 or matching placebo without adjusting dietary phosphorus in a 12-month randomized, double-blind, pilot and feasibility study. The primary outcome was the change in serum phosphorus. Secondary outcomes were changes in measures of phosphate homeostasis and vascular stiffness assessed by carotid-femoral pulse wave velocity (PWV), cIMT and VC over 12 months. RESULTS: There were no statistically significant differences between LaCO3 and placebo with respect to the change in serum phosphorus, urinary phosphorus, tubular reabsorption of phosphorus, PWV, cIMT, or VC. Biomarkers of the early CKD-MBD such as plasma fibroblast growth factor-23, Dickkopf-related protein 1 (DKK1), and sclerostin were increased 2- to 3-fold at baseline, but were not affected by LaCO3. CONCLUSION: Twelve months of LaCO3 had no effect on serum phosphorus and did not alter phosphate homeostasis, PWV, cIMT, VC, or biomarkers of CKD-MBD.


Assuntos
Doenças Cardiovasculares/prevenção & controle , Insuficiência Renal Crônica/tratamento farmacológico , Rigidez Vascular , Idoso , Biomarcadores/metabolismo , Doenças Cardiovasculares/complicações , Complicações do Diabetes/diagnóstico , Método Duplo-Cego , Estudos de Viabilidade , Feminino , Homeostase , Humanos , Lantânio/uso terapêutico , Masculino , Pessoa de Meia-Idade , Fosfatos/química , Fósforo , Fósforo na Dieta/metabolismo , Projetos Piloto , Insuficiência Renal Crônica/complicações , Fatores de Risco , Resultado do Tratamento
10.
BMC Cardiovasc Disord ; 13: 66, 2013 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-24011389

RESUMO

BACKGROUND: Coronary artery disease (CAD) is a major cause of death and disability worldwide. Depression has complex bidirectional adverse associations with CAD, although the mechanisms mediating these relationships remain unclear. Compared to European Americans, African Americans (AAs) have higher rates of morbidity and mortality from CAD. Although depression is common in AAs, its role in the development and features of CAD in this group has not been well examined. This project hypothesizes that the relationships between depression and CAD can be explained by common physiological pathways and gene-environment interactions. Thus, the primary aims of this ongoing project are to: a) determine the prevalence of CAD and depression phenotypes in a population-based sample of community-dwelling older AAs; b) examine the relationships between CAD and depression phenotypes in this population; and c) evaluate genetic variants from serotoninP and inflammatory pathways to discover potential gene-depression interactions that contribute significantly to the presence of CAD in AAs. METHODS/DESIGN: The St. Louis African American Health (AAH) cohort is a population-based panel study of community-dwelling AAs born in 1936-1950 (inclusive) who have been followed from 2000/2001 through 2010. The AAH-Heart study group is a subset of AAH participants recruited in 2009-11 to examine the inter-relationships between depression and CAD in this population. State-of-the-art CAD phenotyping is based on cardiovascular characterizations (coronary artery calcium, carotid intima-media thickness, cardiac structure and function, and autonomic function). Depression phenotyping is based on standardized questionnaires and detailed interviews. Single nucleotide polymorphisms of selected genes in inflammatory and serotonin-signaling pathways are being examined to provide information for investigating potential gene-depression interactions as modifiers of CAD traits. Information from the parent AAH study is being used to provide population-based prevalence estimates. Inflammatory and other biomarkers provide information about potential pathways. DISCUSSION: This population-based investigation will provide valuable information on the prevalence of both depression and CAD phenotypes in this population. The study will examine interactions between depression and genetic variants as modulators of CAD, with the intent of detecting mechanistic pathways linking these diseases to identify potential therapeutic targets. Analytic results will be reported as they become available.


Assuntos
Negro ou Afro-Americano/etnologia , Doenças Cardiovasculares/etnologia , Depressão/etnologia , Nível de Saúde , Vigilância da População/métodos , Negro ou Afro-Americano/genética , Idoso , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/genética , Estudos de Coortes , Estudos Transversais , Depressão/diagnóstico , Depressão/genética , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Missouri/etnologia , Estados Unidos/etnologia
11.
J Am Coll Radiol ; 20(12): 1250-1257, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37805010

RESUMO

PURPOSE: Imaging clinical decision support (CDS) is designed to assist providers in selecting appropriate imaging studies and is now federally required. The aim of this study was to understand the effect of CDS on decisions and workflows in the emergency department (ED). METHODS: The authors' institution's order entry platform serves up structured indications for imaging orders. Imaging orders are scored by CDS on the basis of appropriate use criteria (AUC). CDS triggers alerts for imaging orders with low AUC scores. Because free text alone cannot be scored by CDS, an artificial intelligence predictive text (AIPT) module was implemented to guide the selection of structured indications when free-text indications are entered. A total of 17,355 imaging orders in the ED over 6 months were retrospectively analyzed. RESULTS: CDS alerts for low AUC scores were triggered for 3% of all imaging study orders (522 of 17,355). Providers spent an average of 24 seconds interacting with alerts. In 18 of 522 imaging orders with alerts, alternative studies were ordered. After AIPT implementation, the percentage of unscored studies significantly decreased from 81% to 45% (P < .001). CONCLUSIONS: In a quaternary academic ED, CDS alerts triggered by low AUC scores caused minimal increase in time spent on imaging order entry but had a relatively marginal impact on imaging study selection. AIPT implementation increased the number of scored studies and could potentially enhance CDS effects. CDS implementation enables the collection of novel data regarding which imaging studies receive low AUC scores. Future work could include exploring alternative models of CDS implementation to maximize its impact.


Assuntos
Sistemas de Apoio a Decisões Clínicas , Sistemas de Registro de Ordens Médicas , Humanos , Estudos Retrospectivos , Inteligência Artificial , Serviço Hospitalar de Emergência
12.
Transplant Proc ; 55(2): 432-439, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36914438

RESUMO

BACKGROUND: Accumulated knowledge on the outcomes related to size mismatch in lung transplantation derives from predicted total lung capacity equations rather than individualized measurements of donors and recipients. The increasing availability of computed tomography (CT) makes it possible to measure the lung volumes of donors and recipients before transplantation. We hypothesize that CT-derived lung volumes predict a need for surgical graft reduction and primary graft dysfunction. METHODS: Donors from the local organ procurement organization and recipients from our hospital from 2012 to 2018 were included if their CT exams were available. The CT lung volumes and plethysmography total lung capacity were measured and compared with predicted total lung capacity using Bland Altman methods. We used logistic regression to predict the need for surgical graft reduction and ordinal logistic regression to stratify the risk for primary graft dysfunction. RESULTS: A total of 315 transplant candidates with 575 CT scans and 379 donors with 379 CT scans were included. The CT lung volumes closely approximated plethysmography lung volumes and differed from the predicted total lung capacity in transplant candidates. In donors, CT lung volumes systematically underestimated predicted total lung capacity. Ninety-four donors and recipients were matched and transplanted locally. Larger donor and smaller recipient lung volumes estimated by CT predicted a need for surgical graft reduction and were associated with higher primary graft dysfunction grade. CONCLUSION: The CT lung volumes predicted the need for surgical graft reduction and primary graft dysfunction grade. Adding CT-derived lung volumes to the donor-recipient matching process may improve recipients' outcomes.


Assuntos
Transplante de Pulmão , Disfunção Primária do Enxerto , Humanos , Pulmão , Transplante de Pulmão/efeitos adversos , Transplante de Pulmão/métodos , Medidas de Volume Pulmonar/métodos , Tomografia Computadorizada por Raios X/métodos , Doadores de Tecidos , Estudos Retrospectivos , Tamanho do Órgão
13.
J Thorac Dis ; 15(4): 2233-2239, 2023 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-37197524

RESUMO

Background: Appropriate size matching between donor and recipient is critical for successful pulmonary transplantation. Although surrogate measurements such as height and gender are often utilized to approximate predicted lung volume, these methods provide only a gross estimation with wide variability and poor predictive value. Case Description: A single center exploratory study was conducted in which four patients underwent lung transplantation (LT) with pre-operative computed tomography (CT) volumetry obtained in both the donor and recipient to facilitate decision making regarding organ size and suitability. In four cases in which CT volumetry was used, the lung volumes calculated using surrogate measurements significantly overestimated both donor and recipient lung volumes quantified by CT volumetric analysis. All recipients underwent successful LT without necessary graft downsizing. Conclusions: This is an initial report of prospectively utilizing CT volumetry as an adjunct to decision-making regarding suitability of donor lungs. In these cases, CT volumetry facilitated the confident acceptance of donor lungs that were initially predicted to be oversized based on other clinical measures.

14.
Abdom Radiol (NY) ; 47(7): 2509-2519, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35482105

RESUMO

OBJECTIVE: The purpose of this study was to transition from a traditional score-based peer-review system to an education-oriented peer-learning program in our academic abdominal radiology practice. MATERIAL AND METHODS: This retrospective study compared our experience with a score-based peer-review model used prior to September 2020 and a peer-learning model implemented and used exclusively beginning in October of 2020. In peer review, a web-based peer-review tool randomly generated a list of cases, which were blindly reviewed in consensus. Comparison of the consensus interpretation with the original report was used to categorize each reviewed case and to calculate the rates of significant and minor discrepancies. Only cases with a discrepancy were considered to represent a learning opportunity. In peer learning, faculty prospectively identified and submitted cases for review in several categories, including case interpretations with a discrepancy from subsequent opinion or result, interpretations considered to represent a great call, and interesting or challenging cases meriting further discussion. The peer-learning coordinator showed each case to the group in a manner which blinded the group to both submitting and interpreting radiologist and invited discussion during various stages of the case. RESULTS: During peer review, a total of 172 cases were reviewed over 16 sessions occurring between April 2016 and September 2020. Only 3 cases (1.8%) yielded significant discrepancies whereas 13 (7.6%) yielded minor discrepancies, representing a total of 16 learning opportunities (3.6 per year). In peer learning, 64 cases were submitted and 52 reviewed over 7 sessions occurring between October 2020 and October 2021. 29 (56%) were submitted as an interesting or challenging case meriting further discussion, 18 (35%) were submitted for a discrepancy, and 5 (10%) were submitted for a great call. All 52 presented cases represented learning opportunities (48 per year). CONCLUSION: An education-focused peer-learning program provided a platform for continuous quality improvement and yielded substantially more learning opportunities compared to score-based peer review.


Assuntos
Revisão por Pares , Radiologia , Humanos , Melhoria de Qualidade , Radiologistas , Estudos Retrospectivos
15.
J Am Coll Surg ; 234(2): 166-175, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-35213437

RESUMO

BACKGROUND: Computed tomography (CT) is routinely used to determine the suitability of potential living donor liver transplants, providing important information about liver size, vascular anatomy, and the presence of other diseases that would preclude it from safe donation. CT is not routinely used, however, when evaluating eligible deceased organ donors after brain death, a group which comprises most orthotopic liver transplants. After the installation of a CT scanner at a local procurement facility, CTs have been performed on potential deceased organ donors and used, in conjunction with other evaluative protocols, to help direct donation decisions and assist in procurement procedures. STUDY DESIGN: A retrospective analysis of data from 373 cases spanning 5 years was systematically collected and analyzed, including information pertaining to patient's medical histories, biopsy results, operative findings, and CT results. RESULTS: CT findings directly impacted the directive decision-making process in 29% of cases in this patient cohort, likely an underestimate, and reliably evaluated important factors including variant vascular anatomy and the presence and severity of hepatic steatosis and cirrhosis. CONCLUSION: Overall, this study suggests that CT has the potential to play a significant role in procurement procedures and the directive decision-making process, thereby improving the efficiency and accuracy by which potential deceased organ donors are evaluated.


Assuntos
Transplante de Fígado , Obtenção de Tecidos e Órgãos , Humanos , Fígado/diagnóstico por imagem , Doadores Vivos , Estudos Retrospectivos , Doadores de Tecidos , Tomografia Computadorizada por Raios X
16.
Ann Thorac Surg ; 114(4): e249-e251, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-34998737

RESUMO

Partial anomalous pulmonary venous return is a rare congenital aberrancy that involves oxygen-rich pulmonary venous drainage into the right atrium instead of into the systemic circulation. This report describes a case of isolated partial anomalous pulmonary venous return of the right upper lobe in a donor lung. Successful transplantation was performed with a Carrel patch technique for left atrial cuff reconstruction using a segment of donor vena cava. This report of partial anomalous pulmonary venous return in a right donor lung describes this reconstructive approach to restore physiologic venous drainage.


Assuntos
Veias Pulmonares , Síndrome de Cimitarra , Humanos , Pulmão , Oxigênio , Veias Pulmonares/anormalidades , Veias Pulmonares/cirurgia , Síndrome de Cimitarra/cirurgia , Veia Cava Superior/cirurgia
17.
J Thorac Dis ; 14(4): 1042-1051, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35572863

RESUMO

Background: Errors in measuring chest X-ray (CXR) lung heights could contribute to the occurrence of size-mismatched lung transplant procedures. Methods: We first used Bland-Altman analysis for repeated measures to evaluate contributors to measurement error of chest X-ray lung height. We then applied error propagation theory to assess the impact of measurement error on size matching for lung transplantation. Results: A total 387 chest X-rays from twenty-five donors and twenty-five recipients were measured by two raters. Individual standard deviation for lung height differences were independent of age, sex, donor vs. recipient, diagnostic group and race/ethnicity and all were pooled for analysis. Bias between raters was 0.27 cm (±0.03) and 0.22 cm (±0.06) for the right and left lung respectively. Within subject variability was the biggest contributor to error in measurement, 2.76 cm (±0.06) and 2.78 cm (±0.2) for the right and left lung height. A height difference of 4.4 cm or more (95% CI: ±4.2, ±4.6 cm) between the donor and the recipient right lung height has to be accepted to ensure matching for at least 95% of patients with the same true lung height. This difference decreases to ±1.1 cm (95% CI: ±0.9, ±1.3 cm) when the average from all available chest X-rays is used. The probability of matching a donor and a recipient decreases with increasing true lung height difference. Conclusions: Individual chest X-ray lung heights are imprecise for the purpose of size matching in lung transplantation. Averaging chest X-rays lung heights reduced uncertainty.

18.
Am J Nephrol ; 33(2): 131-8, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21242673

RESUMO

BACKGROUND AND OBJECTIVES: Vascular calcification is a major contributor to morbidity and mortality in hemodialysis. The objective of this pilot study was to determine the feasibility, safety and efficacy of sodium thiosulfate (STS) in the progression of vascular calcification in hemodialysis patients. METHODS: Chronic hemodialysis patients underwent a battery of cardiovascular tests. Those with coronary artery calcium (Agatston scores >50) received intravenous STS after each dialysis for 5 months (n = 22) and the tests were repeated. Changes in MDCT-determined calcification were assessed as the mean annualized rate of change in 3 vascular beds (coronary, thoracic and carotid arteries) and in L1-L2 vertebral bone density. RESULTS: Although individual analyses showed coronary artery calcification progression in 14/22 subjects, there was no progression in the mean annualized rate of change of vascular calcification in the entire group. The L1-L2 vertebral bone density showed no changes. There were no correlations between rates of progression of vascular calcification and phosphorus, fetuin or C-reactive protein levels. Changes in coronary artery calcification scores correlated with those of the thoracic aorta. CONCLUSION: STS treatment is feasible, appears safe and may decrease the rate of progression of vascular calcification in hemodialysis patients. A large, randomized, controlled trial is warranted.


Assuntos
Falência Renal Crônica/tratamento farmacológico , Tiossulfatos/farmacologia , Idoso , Aorta Torácica/patologia , Densidade Óssea , Proteína C-Reativa/biossíntese , Artérias Carótidas/diagnóstico por imagem , Ecocardiografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fósforo/sangue , Projetos Piloto , Diálise Renal/métodos , Ultrassonografia/métodos , alfa-Fetoproteínas/biossíntese
19.
Med Phys ; 38(8): 4894-902, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21928661

RESUMO

PURPOSE: To mathematically model the relationship between CT measurements of emphysema obtained from images reconstructed using different section thicknesses and kernels and to evaluate the accuracy of the models for converting measurements to those of a reference reconstruction. METHODS: CT raw data from the lung cancer screening examinations of 138 heavy smokers were reconstructed at 15 different combinations of section thickness and kernel. An emphysema index was quantified as the percentage of the lung with attenuation below -950 HU (EI950). Linear, quadratic, and power functions were used to model the relationship between EI950 values obtained with a reference 1 mm, medium smooth kernel reconstruction and values from each of the other 14 reconstructions. Preferred models were selected using the corrected Akaike information criterion (AICc), coefficients of determination (R2), and residuals (conversion errors), and cross-validated by a jackknife approach using the leave-one-out method. RESULTS: The preferred models were power functions, with model R2 values ranging from 0.949 to 0.998. The errors in converting EI950 measurements from other reconstructions to the 1 mm, medium smooth kernel reconstruction in leave-one-out testing were less than 3.0 index percentage points for all reconstructions, and less than 1.0 index percentage point for five reconstructions. Conversion errors were related in part to image noise, emphysema distribution, and attenuation histogram parameters. Conversion inaccuracy related to increased kernel sharpness tended to be reduced by increased section thickness. CONCLUSIONS: Image reconstruction-related differences in quantitative emphysema measurements were successfully modeled using power functions.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Enfisema Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Humanos , Processamento de Imagem Assistida por Computador/normas , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Modelos Estatísticos , Reprodutibilidade dos Testes
20.
AJR Am J Roentgenol ; 194(3): 585-91, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20173132

RESUMO

OBJECTIVE: The purpose of this study was to assess the accuracy of emphysema measurements obtained from systematic samples of evenly spaced CT images compared with measurements obtained from the entire scan. MATERIALS AND METHODS: Evenly spaced transverse sections from the CT studies of 136 heavy smokers who underwent screening for lung cancer in the National Lung Screening Trial and of 112 subjects who underwent imaging before lung volume reduction surgery were sampled retrospectively. The samples were acquired both by selection of specific numbers of evenly spaced images and by selection of images at specific distance intervals. The percentage of lung pixels with attenuation below specific thresholds was used as an emphysema index. The image sample error was determined as the difference in emphysema index between the image samples and the entire scan. RESULTS: The largest absolute image sample errors in the National Lung Screening Trial cohort with image sample sizes of five, 10, and 20 were 2.2, 0.8, and 0.5 index percentage points, respectively, at 1-mm section thickness (-960 HU threshold), and 2.6, 1.1, and 0.5 index percentage points at 5-mm section thickness (-930 HU threshold). The largest errors in the lung volume reduction surgery cohort for image sample sizes of five and 10 were 5.6 and 2.3 index percentage points at 8- to 10-mm section thickness (-900 HU threshold). Image sample errors were equivalent for the two sampling methods. CONCLUSION: Systematic sampling resulted in very small errors in emphysema quantification and may be useful for decreasing radiation exposure in clinical research studies of emphysema.


Assuntos
Enfisema Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Análise de Variância , Feminino , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/etiologia , Masculino , Pessoa de Meia-Idade , Enfisema Pulmonar/etiologia , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Índice de Gravidade de Doença , Fumar/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA