Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Biomed Opt ; 29(2): 026001, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38312853

RESUMO

Significance: Near-infrared fluorescence imaging still lacks a standardized, objective method to evaluate fluorescent dye efficacy in oncological surgical applications. This results in difficulties in translation between preclinical to clinical studies with fluorescent dyes and in the reproduction of results between studies, which in turn hampers further clinical translation of novel fluorescent dyes. Aim: Our aim is to develop and evaluate a semi-automatic standardized method to objectively assess fluorescent signals in resected tissue. Approach: A standardized imaging procedure was designed and quantitative analysis methods were developed to evaluate non-targeted and tumor-targeted fluorescent dyes. The developed analysis methods included manual selection of region of interest (ROI) on white light images, automated fluorescence signal ROI selection, and automatic quantitative image analysis. The proposed analysis method was then compared with a conventional analysis method, where fluorescence signal ROIs were manually selected on fluorescence images. Dice similarity coefficients and intraclass correlation coefficients were calculated to determine the inter- and intraobserver variabilities of the ROI selections and the determined signal- and tumor-to-background ratios. Results: The proposed non-targeted fluorescent dyes analysis method showed statistically significantly improved variabilities after application on indocyanine green specimens. For specimens with the targeted dye SGM-101, the variability of the background ROI selection was statistically significantly improved by implementing the proposed method. Conclusion: Semi-automatic methods for standardized quantitative analysis of fluorescence images were successfully developed and showed promising results to further improve the reproducibility and standardization of clinical studies evaluating fluorescent dyes.


Assuntos
Neoplasias , Cirurgia Assistida por Computador , Humanos , Corantes Fluorescentes , Reprodutibilidade dos Testes , Neoplasias/diagnóstico por imagem , Neoplasias/cirurgia , Cirurgia Assistida por Computador/métodos , Imagem Óptica/métodos , Verde de Indocianina
2.
JAMA Netw Open ; 7(4): e246548, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38639939

RESUMO

Importance: Unintended tumor-positive resection margins occur frequently during minimally invasive surgery for colorectal liver metastases and potentially negatively influence oncologic outcomes. Objective: To assess whether indocyanine green (ICG)-fluorescence-guided surgery is associated with achieving a higher radical resection rate in minimally invasive colorectal liver metastasis surgery and to assess the accuracy of ICG fluorescence for predicting the resection margin status. Design, Setting, and Participants: The MIMIC (Minimally Invasive, Indocyanine-Guided Metastasectomy in Patients With Colorectal Liver Metastases) trial was designed as a prospective single-arm multicenter cohort study in 8 Dutch liver surgery centers. Patients were scheduled to undergo minimally invasive (laparoscopic or robot-assisted) resections of colorectal liver metastases between September 1, 2018, and June 30, 2021. Exposures: All patients received a single intravenous bolus of 10 mg of ICG 24 hours prior to surgery. During surgery, ICG-fluorescence imaging was used as an adjunct to ultrasonography and regular laparoscopy to guide and assess the resection margin in real time. The ICG-fluorescence imaging was performed during and after liver parenchymal transection to enable real-time assessment of the tumor margin. Absence of ICG fluorescence was favorable both during transection and in the tumor bed directly after resection. Main Outcomes and Measures: The primary outcome measure was the radical (R0) resection rate, defined by the percentage of colorectal liver metastases resected with at least a 1 mm distance between the tumor and resection plane. Secondary outcomes were the accuracy of ICG fluorescence in detecting margin-positive (R1; <1 mm margin) resections and the change in surgical management. Results: In total, 225 patients were enrolled, of whom 201 (116 [57.7%] male; median age, 65 [IQR, 57-72] years) with 316 histologically proven colorectal liver metastases were included in the final analysis. The overall R0 resection rate was 92.4%. Re-resection of ICG-fluorescent tissue in the resection cavity was associated with a 5.0% increase in the R0 percentage (from 87.4% to 92.4%; P < .001). The sensitivity and specificity for real-time resection margin assessment were 60% and 90%, respectively (area under the receiver operating characteristic curve, 0.751; 95% CI, 0.668-0.833), with a positive predictive value of 54% and a negative predictive value of 92%. After training and proctoring of the first procedures, participating centers that were new to the technique had a comparable false-positive rate for predicting R1 resections during the first 10 procedures (odds ratio, 1.36; 95% CI, 0.44-4.24). The ICG-fluorescence imaging was associated with changes in intraoperative surgical management in 56 (27.9%) of the patients. Conclusions and Relevance: In this multicenter prospective cohort study, ICG-fluorescence imaging was associated with an increased rate of tumor margin-negative resection and changes in surgical management in more than one-quarter of the patients. The absence of ICG fluorescence during liver parenchymal transection predicted an R0 resection with 92% accuracy. These results suggest that use of ICG fluorescence may provide real-time feedback of the tumor margin and a higher rate of complete oncologic resection.


Assuntos
Neoplasias Colorretais , Neoplasias Hepáticas , Idoso , Feminino , Humanos , Masculino , Estudos de Coortes , Neoplasias Colorretais/cirurgia , Neoplasias Colorretais/patologia , Verde de Indocianina , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/patologia , Margens de Excisão , Imagem Óptica/métodos , Estudos Prospectivos , Pessoa de Meia-Idade
3.
Artigo em Inglês | MEDLINE | ID: mdl-39151436

RESUMO

BACKGROUND: Anastomotic leakage is a severe postoperative complication in colorectal surgery and compromised bowel perfusion is considered a major contributing factor. Conventional methods to assess bowel perfusion have a low predictive value for anastomotic leakage. We therefore aimed to evaluate the efficacy of real-time assessment with near-infrared (NIR) fluorescence imaging with indocyanine green (ICG) in the prevention of anastomotic leakage. METHODS: This multicentre, randomised, controlled, phase 3 trial was done in eight hospitals in the Netherlands. We included adults (aged >18 years) who were scheduled for laparoscopic or robotic colorectal surgery (with planned primary anastomosis) for benign and malignant diseases. Preoperatively, patients were randomly assigned (1:1) to fluorescence-guided bowel anastomosis (FGBA) or conventional bowel anastomosis (CBA) by variable block randomisation (block sizes 4, 6, and 8) and stratified by site. The operating surgeon and investigators analysing the data were not masked to group assignment. Patients were unmasked after the surgical procedure or after study end. In the FGBA group, surgeons marked anastomosis levels per conventional perfusion assessment and then administered 5 mg of ICG by 2 mL intravenous bolus. They assessed bowel perfusion using NIR fluorescence imaging and adjusted (or kept) transection lines accordingly. Only conventional methods for bowel perfusion assessment were used in the CBA group. The primary outcome was the difference in the rate of clinically relevant anastomotic leakage (ie, requiring active therapeutic intervention but manageable without reoperation [grade B] or requiring reoperation [grade C], per the International Study Group of Rectal Cancer) between the FGBA group and the CBA group within 90 days post-surgery. The primary outcome and safety were assessed in the intention-to-treat population. This study was registered with ToetsingOnline.nl (NL7502) and ClinicalTrials.gov (NCT04712032) and is complete. FINDINGS: Between July 2, 2020, and Feb 21, 2023, 982 patients were enrolled, of whom 490 were assigned to FGBA and 492 were assigned to CBA. After excluding 51 patients, the intention-to-treat population comprised 931 (463 assigned FGBA and 468 assigned CBA). Patients had a median age of 68·0 years (IQR 59·0-75·0) and 485 (52%) were male and 446 (48%) were female. Ethnicity data were not available. The overall 90-day rate of clinically relevant anastomotic leakage was not significantly different between the FGBA group (32 [7%] of 463 patients) and the CBA group (42 [9%] of 468 patients; relative risk 0·77 [95% CI 0·50-1·20]; p=0·24). No adverse events related to ICG use were observed. 313 serious adverse events in 229 (25%) patients were at 90-day follow-up (159 serious adverse events in 113 [24%] patients in the FGBA group and 154 serious adverse events in 116 [25%] patients in the CBA group). 18 (2%) people died by 90 days (ten in the FGBA group and eight in the CBA group). INTERPRETATION: ICG NIR fluorescence imaging did not reduce 90-day anastomotic leakage rates in this trial across all types of colorectal surgeries. Further research should be done in subgroups, such as rectosigmoid resections, for which evidence suggests ICG NIR might be beneficial. FUNDING: Olympus Medical, Diagnostic Green, and Intuitive Foundation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA