Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Anesth Analg ; 129(3): 701-708, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31425209

RESUMO

BACKGROUND: Ketorolac tromethamine has been used for joint infiltration by the orthopedic surgeons as a part of postoperative multimodal analgesia. The objective of this study is to investigate the pharmacokinetic properties of S (-) and R (+) enantiomers of ketorolac in adult patients undergoing total hip (THA) and knee arthroplasty (TKA). METHODS: Adult patients with normal preoperative renal function received a periarticular infiltration of 30 mg of ketorolac tromethamine along with 100 mL of 0.2% ropivacaine and 1 mg of epinephrine at the end of their THA or TKA surgery. Blood samples were taken from a venous cannula at various time points after infiltration. Pharmacokinetic modeling was performed using PMetrics 1.5.0. RESULTS: From 18 participants, 104 samples were analyzed. The peak plasma concentration for S (-) ketorolac was found to be lower than that of R (+) ketorolac, for both THA (0.19-1.22 mg/L vs 0.39-1.63 mg/L, respectively) and TKA (0.28-0.60 mg/L vs 0.48-0.88 mg/L, respectively). The clearance of the S (-) ketorolac enantiomer was higher than R (+) ketorolac (4.50 ± 2.27 vs 1.40 ± 0.694 L/h, respectively). CONCLUSIONS: Our study demonstrates that with periarticular infiltration, S (-) ketorolac was observed to have increased clearance rate and highly variable volume of distribution and lower peak plasma concentration compared to R (+) ketorolac.


Assuntos
Anti-Inflamatórios não Esteroides/farmacocinética , Artroplastia de Quadril/efeitos adversos , Artroplastia do Joelho/efeitos adversos , Cápsula Articular/metabolismo , Cetorolaco/farmacocinética , Dor Pós-Operatória/sangue , Idoso , Idoso de 80 Anos ou mais , Anti-Inflamatórios não Esteroides/administração & dosagem , Artroplastia de Quadril/tendências , Artroplastia do Joelho/tendências , Feminino , Humanos , Cápsula Articular/efeitos dos fármacos , Cetorolaco/administração & dosagem , Masculino , Pessoa de Meia-Idade , Dor Pós-Operatória/tratamento farmacológico
2.
Hip Int ; 24(2): 144-8, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24186674

RESUMO

BACKGROUND: Metal ion release is common following total hip arthroplasty, yet postoperative levels have not been defined for most stems currently used in clinical practice. AIM: To assess metal ion release in the serum of patients with well functioning unilateral Exeter V40 primary total hip arthroplasties one year after surgery. METHODS: Whole blood chromium and serum cobalt levels were measured in 20 patients following primary total hip arthroplasty with the Exeter V40 stem and a variety of acetabular components one year after surgery. RESULTS: Whole blood chromium levels were within the normal range (10-100 nmol/L), with a single mild elevation of serum cobalt (normal <20 nmol/L). CONCLUSIONS: In well functioning primary unilateral total hip arthroplasty using the Exeter V40 stem with a variety of acetabular components one year post surgery, whole blood chromium levels are normal and serum cobalt elevations are rare and mild.


Assuntos
Artroplastia de Quadril , Metais/sangue , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/métodos , Feminino , Prótese de Quadril , Humanos , Íons/sangue , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Desenho de Prótese
SELEÇÃO DE REFERÊNCIAS