Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Vasc Surg ; 79(2): 217-227.e1, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37852334

RESUMO

OBJECTIVE: To investigate the effect of narrow paravisceral aorta (NPA) on target vessel instability (TVI) after fenestrated-branched endovascular aortic repair. METHODS: We conducted a single-center retrospective study (2014-2023) of patients treated by fenestrated-branched endovascular aortic repair for thoracoabdominal aortic aneurysms (TAAA) or pararenal aortic aneurysms. The paravisceral aorta was defined as the aortic segment limited by the diaphragmatic hiatus proximally and the emergence of lower renal artery distally, and was considered "narrow" in case of a minimum inner diameter of <25 mm. The minimum aortic diameter, location, longitudinal extension, angulation, calcification, and thrombus thickness of NPA were evaluated at the preoperative computed tomography angiogram. End points were 30-day technical success and freedom from TVI. RESULTS: There were 142 patients with JRAA/pararenal aortic aneurysm (n = 85 [59%]) and extent IV (n = 24 [17%]) or extent I-III (n = 33 [23%]) TAAA, with 513 target arteries successfully incorporated through a fenestration (n = 294 [57%]) or directional branch (n = 219 [43%]). A NPA was present in 95 patients (70%), 73 (86%) treated by fenestrated endovascular aortic repair (FEVAR) and 22 (39%) by branched endovascular aortic repair (BEVAR). The overall 30-day mortality was 2% and technical success was 99%, without differences between NPA and non-NPA (P = .99). Kaplan-Meier estimated freedom from TVI at 4 years was 82%, 81% (95% CI, 75-95) in patients with a NPA and 80% (95% CI, 68-94) and in those without NPA (P = .220). The result was maintained for both FEVAR (NPA: 81% [95% CI, 62-88]; non-NPA: 76% [95% CI, 60-99]; P = .870) and BEVAR (NPA: 77% [95% CI, 69-99]; non-NPA: 80% [95% confidence interval (CI) 66-99]; P = .100). After multivariate analysis, the concomitant presence of a NPA <20 mm and angulation of >30° was significantly associated with TVI in FEVAR (HR, 3.21; 95% CI, 1.03-48.70; P = .036), being the result mostly driven by target vessel occlusion. In BEVAR, a NPA diameter of <25 mm was not associated with TVI (HR, 2.02; 95% CI, 0.59-5.23; P = .948); after multivariate analysis, the use of outer branches in case of a NPA longitudinal extension of >25 mm (hazard ratio [HR], 3.02; 95% CI, 1.01-36.33; P = .040) and NPA severe calcification (HR, 1.70; 95% CI, 1.00-22.42; P = .048) were associated with a higher chance for TVI. CONCLUSIONS: FEVAR and BEVAR are both feasible in cases of NPA and provide satisfactory target vessels durability. The use of outer branches should be avoided in cases with an inner aortic diameter of <25 mm with a longitudinal extension of >25 mm or moderate to severe NPA calcifications. In FEVAR, bridging stent patency may be negatively influenced by NPA of <20 mm in association with aortic angulation of >30°.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Correção Endovascular de Aneurisma , Prótese Vascular , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia , Implante de Prótese Vascular/efeitos adversos , Estudos Retrospectivos , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Fatores de Risco , Procedimentos Endovasculares/efeitos adversos , Resultado do Tratamento , Fatores de Tempo , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/etiologia , Aorta/cirurgia
2.
J Vasc Surg Cases Innov Tech ; 10(4): 101517, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39034961

RESUMO

The aim is to describe the technical feasibility, early outcomes, and graft stability of the Excluder iliac branch endoprosthesis (W.L. Gore & Associates) used as an infrarenal abdominal bifurcated endograft in cases unsuitable for standard endovascular aortic repair. The technique was used in 13 cases with abdominal and/or iliac aneurysms (n = 6), occlusive disease (n = 3), or complex aneurysms in association with a proximal fenestrated/branched endograft (n = 4). Technical success was 100%, and there were no adverse events, with 100% graft stability at 3 months. This case series demonstrates, in extremely selected cases, the feasibility and safety of Excluder iliac branch endoprosthesis used as an infrarenal aortic bifurcated device.

3.
J Vasc Surg Cases Innov Tech ; 10(5): 101580, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39234560

RESUMO

Cone-beam computed tomography (CBCT) is widely used for the technical assessment of standard and complex endovascular aortic interventions. Use of iodinated contrast in CBCT imaging might provide useful additional information; however, this also increases the procedural contrast dose, which may cause renal function deterioration, and the radiation exposure. We describe the technique and feasibility of carbon-dioxide (CO2)-enhanced CBCT for the technical assessment of standard and complex endovascular aortic repair. In our experience CO2-CBCT had no related adverse events and provided satisfactory imaging quality to assess endograft integrity, vessels patency, and was safely performed in case of severe chronic renal insufficiency.

4.
J Vasc Surg Cases Innov Tech ; 9(3): 101215, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37408941

RESUMO

We describe the feasibility of a technique for temporary aneurysm sac reperfusion after endovascular single-stage thoracoabdominal aortic aneurysm exclusion, to be used in the case of postoperative spinal cord ischemia. Two cases were treated for impending rupture of a thoracoabdominal aortic aneurysm. Before completion of sac exclusion, a supplementary buddy wire (V-18 control guidewire; Boston Scientific) was advanced in parallel fashion from the left percutaneous femoral access into the aneurysmal sac on the posterior aspect of the endograft. Distal aneurysm exclusion was completed using the main superstiff guidewire, and the femoral access was closed with a percutaneous closure device (ProGlide; Abbott) in standard fashion, leaving in place the sole V-18 guidewire, draped in sterile fashion. In the case of spinal cord ischemia, the "safe-line" can be rapidly used for spinal reperfusion after trans-sealing exchange with a 6F, 65-cm-long Destination sheath (Terumo) connected to a 6F introducer on the contralateral femoral artery.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA