Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Instr Course Lect ; 73: 901-918, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38090947

RESUMO

Fractures of the tibia and femur are common. Rotation of the limb can affect the outcome of the injury, both in the immediate term and the long term. Because plain radiographs are two dimensional, rotation is hard to assess radiographically. As a result, rotational malalignment is common. It is important to provide technical tips on the assessment of rotation preoperatively, intraoperatively, and postoperatively. The goal is to better assess rotation so that deformity can be minimized. This applies to fractures of the tibia and femur. Even after careful treatment, rotational deformities can occur. When they are symptomatic, correction should be considered. Techniques for correction of malrotation of both tibial and femoral fractures are presented.


Assuntos
Fraturas do Fêmur , Fêmur , Humanos , Fêmur/cirurgia , Tíbia/cirurgia , Extremidade Inferior , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/cirurgia , Radiografia
2.
J Arthroplasty ; 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38823521

RESUMO

Acute fractures around the hip are prevalent injuries associated with potentially devastating outcomes. The growing utilization of arthroplasty for femoral neck fractures in the elderly is likely a result of improvements in reoperation rates and postoperative function. Compared to hemiarthroplasty, total hip arthroplasty is associated with a slight functional benefit that is unlikely noticeable for many patients, as well as minimal differences in complications and patient reported outcome measures. However, the evidence supporting cement use in femoral stem fixation is robust. Multiple high power randomized controlled trial-based studies indicate cement fixation brings more predictable outcomes and fewer reoperations. In the setting of acute acetabular fracture, total hip arthroplasty is a favorable approach for elderly patients and fracture patterns associated with increased risk of revision after open reduction and internal fixation. Variations in patient characteristics and fracture patterns demand careful consideration whenever selecting the optimal treatment. In fracture patient populations, comanagement is an important consideration when seeking to reduce complications and promote cost-effective quality care.

3.
J Orthop Trauma ; 38(7): e245-e251, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38837212

RESUMO

OBJECTIVES: To determine the accuracy of the intermalleolar method, an intraoperative fluoroscopic method for assessing tibial rotation in patients undergoing intramedullary nail fixation for tibial shaft fractures, by comparing it with the gold standard computed tomography (CT). DESIGN: Prospective cohort study. SETTING: Academic Level 1 trauma center. PATIENT SELECTION CRITERIA: Consecutive patients, aged 18 years and older, with unilateral tibial shaft fractures who underwent intramedullary fixation from September 2021 to January 2023. OUTCOME MEASURES AND COMPARISONS: Intraoperatively, tibial rotation measurements were obtained using the intermalleolar method on both the uninjured and injured limbs. Postoperatively, patients underwent bilateral low-dose lower extremity rotational CT scans. CT measurements were made by 4 blinded observers. Mean absolute rotational differences and standard errors were calculated to compare the injured and uninjured limbs. Subgroup analysis was performed assessing accuracy relating to injured versus uninjured limbs, body mass index, OTA/AO fracture pattern, tibial and fibular fracture location, and distal articular fracture extension requiring fixation. RESULTS: Of the 20 tibia fractures, the mean patient age was 43.4 years. The intermalleolar method had a mean absolute rotational difference of 5.1 degrees (standard error 0.6, range 0-13.7) compared with CT. Sixty percent (24/40) of the measurements were within 5 degrees, 90% (36/40) of the measurements were within 10 degrees, and 100% (40/40) were within 15 degrees of the CT. No patients were revised for malrotation postoperatively. CONCLUSIONS: The intermalleolar method is accurate and consistently provides intraoperative tibial rotation measurements within 10 degrees of the mean CT measurement for adult patients undergoing intramedullary nail fixation for unilateral tibial shaft fractures. This method may be employed in the operating room to accurately quantify tibial rotation and assist with intraoperative rotational corrections. LEVEL OF EVIDENCE: Diagnostic Level II. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Fixação Intramedular de Fraturas , Fraturas da Tíbia , Tomografia Computadorizada por Raios X , Humanos , Fraturas da Tíbia/cirurgia , Fraturas da Tíbia/diagnóstico por imagem , Fixação Intramedular de Fraturas/métodos , Estudos Prospectivos , Adulto , Masculino , Feminino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Fluoroscopia , Rotação , Idoso , Tíbia/cirurgia , Tíbia/diagnóstico por imagem , Cuidados Intraoperatórios/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA