Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
1.
Eur J Clin Invest ; 53(7): e13977, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36852491

RESUMO

BACKGROUND: Wearable cardioverter defibrillators (WCD) are used as a 'bridging' technology in patients, who are temporarily at high risk for sudden cardiac death (SCD). Several factors should be taken into consideration, for example patient selection, compliance and optimal drug treatment, when WCD is prescribed. We aimed to present real-world data from seven centres from Germany and Switzerland according to age differences regarding the outcome, prognosis, WCD data and compliance. MATERIALS AND METHODS: Between 04/2012 and 03/2021, 1105 patients were included in this registry. Outcome data according to age differences (old ≥45 years compared to young <45 years) were analysed. At young age, WCDs were more often prescribed due to congenital heart disease and myocarditis. On the other hand, ischaemic cardiomyopathy (ICM) was more present in older patients. Wear days of WCD were similar between both groups (p = .115). In addition, during the WCD use, documented arrhythmic life-threatening events were comparable [sustained ventricular tachycardia: 5.8% vs. 7.7%, ventricular fibrillation (VF) .5% vs. .6%] and consequently the rate of appropriate shocks was similar between both groups. Left ventricular ejection fraction improvement was documented over follow-up with a better improvement in younger patients as compared to older patients (77% vs. 63%, p = .002). In addition, at baseline, the rate of atrial fibrillation was significantly higher in the older age group (23% vs. 8%; p = .001). The rate of permanent cardiac implantable electronic device implantation (CiED) was lower in the younger group (25% vs. 36%, p = .05). The compliance rate defined as wearing WCD at least 20 h per day was significantly lower in young patients compared to old patients (68.9% vs. 80.9%, p < .001). During the follow-up, no significant difference regarding all-cause mortality or arrhythmic death was documented in both groups. A low compliance rate of wearing WCD is predicted by young patients and patients suffering from non-ischaemic cardiomyopathies. CONCLUSION: Although the compliance rate in different age groups is high, the average wear hours tended to be lower in young patients compared to older patients. The clinical events were similar in younger patients compared to older patients.


Assuntos
Fibrilação Atrial , Isquemia Miocárdica , Dispositivos Eletrônicos Vestíveis , Humanos , Idoso , Pessoa de Meia-Idade , Volume Sistólico , Função Ventricular Esquerda , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Isquemia Miocárdica/terapia , Isquemia Miocárdica/complicações , Sistema de Registros , Fibrilação Atrial/complicações , Desfibriladores/efeitos adversos , Estudos Retrospectivos
2.
J Stroke Cerebrovasc Dis ; 32(8): 107104, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37156088

RESUMO

OBJECTIVES: Recently published results of the ANGEL-ASPECT and SELECT2 trials suggest that stroke patients presenting with low Alberta Stroke Program Early Computed Tomography Score (ASPECTS) benefit from mechanical thrombectomy. Purpose of this retrospective study was to identify factors that are associated with a favorable outcome in patients with low ASPECTS of 4-5 and 0-3 undergoing mechanical thrombectomy. MATERIAL AND METHODS: All patients reported in the quality registry of the German Society for Neuroradiology that were treated between 2018 and 2020 were analyzed. Favorable outcome was defined as a National Institute of Health Stroke Scale (NIHSS) score of less than 9 at dismissal. Successful recanalization was defined as Thrombolysis in Cerebral Infarction (mTICI) ≥ 2b. Multivariable logistic regression analyses were performed to assess the association of baseline and treatment variables with favorable outcome. RESULTS: 621 patients were included in the analysis, thereof 495 with ASPECTS 4-5 and 126 with ASPECTS 0-3. In patients with ASPECTS 4-5patients with favorable outcome had less severe neurological symptoms at admission with median NIHSS of 15 vs. 18 (p<0.001), had less often wake-up strokes (44% vs. 81%, p<0.001), received more often iv-lysis (37% vs. 30%, p<0.001), had more often conscious sedation (29% vs. 16%, p<0.001), had a higher rate of successful recanalization (94% vs. 66% and lower times from groin puncture to recanalization. In multivariate regression analysis lower NIHSS at admission (aOR 0.87, CI 0.89-0.91) and successful recanalization (aOR 3.96, CI 2-8.56) were associated with favorable outcome. For ASPECTS 0-3, patients with favorable outcome had lower median NIHSS at admission (16 vs. 18 (p<0.001), lower number of passes (1 vs. 3, p=0.003) and a higher rate of successful recanalization (94% vs. 66%, p<0.001) and lower times from groin puncture to recanalization. In multivariate regression analysis lower NIHSS at admission (aOR 0.87, CI 0.81-0.94) and successful recanalization, (aOR 11.19, CI 3.19-55.53), were associated with favorable outcome. CONCLUSION: Full recanalization with low groin punction to recanalization times and low number of passes were associated with favorable outcome in patients with low ASPECTS.


Assuntos
AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Alberta , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/terapia , Trombectomia/efeitos adversos , Tomografia
3.
Rev Cardiovasc Med ; 22(3): 1047-1052, 2021 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-34565106

RESUMO

Pulmonary vein isolation (PVI) has become a cornerstone therapy in the treatment of atrial fibrillation (AF). Patients with overweight or obesity suffer more often from AF, and studies investigating the safety and feasibility of PVI in these patients have shown varying results. In this study we analyzed PVI performed with the 2nd generation cryoballoon (CB) with regard to safety, procedure and fluoroscopy time in patients with normal weight, overweight and obesity. We analyzed 228 consecutive patients treated with CB PVI in our hospital in 2018 and 2019. Fifty nine (25.88%) patients presented with normal weight (body mass index (BMI) of <25), 115 (50.44%) patients with overweight (BMI between 25 and 29.9) and 54 (23.68%) were obese patients (BMI >30). All pulmonary veins (PV) were isolated successfully. Concerning procedural parameters, neither complications, procedural time, nor fluoroscopy time differed significantly. There was a significant increase of dose area product (DAP) in obese patients compared to normal weight and overweight patients (2035.5 ± 1930.1 µGym2 vs. 975.3 ± 814.9 vs. 1325.1 ± 2081.3, p = 0.001) but no significant difference between overweight and normal weight patients (p = 0.611). Our follow-up data of 168 patients (73.68%) observed for 12 months showed no differences in the recurrence of AF in the three BMI groups [80.9% vs. 83.3% (p = 0.733) vs. 86.55% (p = 0.460)]. In conclusion, CB PVI in overweight and obese patients is safe with similar levels of complications and recurrence of AF as patients of normal weight. However, obese patients and operators are exposed to higher radiation doses.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Humanos , Obesidade/complicações , Obesidade/diagnóstico , Obesidade/epidemiologia , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
5.
Europace ; 20(FI_3): f359-f365, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-29016757

RESUMO

Aims: Atrial fibrillation (AF) is associated with thromboembolic events. Currently, the CHA2DS2-VASc score is recommended for thromboembolic risk stratification in non-valvular AF patients. However, recent data suggested a potential role of atrial remodelling on thromboembolism. This study aimed to assess the association between left atrial low-voltage area (LVA) and history of clinical manifest as well as subclinical silent cerebral ischaemia (SCI) in AF patients. Methods and results: Two-hundred patients [64 ± 10.5 years, 75 women (37.5%)] with symptomatic paroxysmal (n = 88, 44%) or persistent AF undergoing pulmonary vein isolation (PVI) were prospectively enrolled. Left atrial LVA (bipolar voltage < 0.5mV) was evaluated by intra-procedural mapping (>300 points per patient) during sinus rhythm. Cerebral delayed-enhancement magnetic resonance imaging was performed after PVI for detection of pre-existing procedural-independent SCI. Over all, 17 patients (8.5%) had previous history of stroke. Pre-existing SCIs were detected in 135 patients (67.5%). Patients with previous stroke (4.0 ± 1.5 vs. 2.1 ± 1.3, P < 0.0001) and pre-existing SCI (2.7 ± 1.3 vs. 1.5 ± 1.4, P < 0.0001) had a significantly higher CHA2DS2-VASc score. LVA was significantly larger in patients with previous stroke (12.5 ± 8.5% vs. 3.4 ± 5.4%, P < 0.0001) as well as pre-existing SCI (5.8 ± 6.9% vs. 0.8 ± 1.7%, P < 0.0001). Multivariate regression analysis revealed that LVA was independently associated with the presence of SCI [hazard ratio (HR) per 1% LVA 1.13 (1.06-1.22), P = 0.0003] and history of stroke [HR per 1% LVA 1.36 (1.19-1.60), P < 0.0001] after adjustment of CHA2DS2-VASc score. Conclusion: Left atrial LVA is associated with history of stroke and SCI in patients with non-valvular AF and might improve thromboembolic risk stratification after confirmation of its predictive value in future studies.


Assuntos
Potenciais de Ação , Fibrilação Atrial/complicações , Função do Átrio Esquerdo , Remodelamento Atrial , Isquemia Encefálica/etiologia , Átrios do Coração/fisiopatologia , Veias Pulmonares/fisiopatologia , Tromboembolia/etiologia , Idoso , Doenças Assintomáticas , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/fisiopatologia , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Feminino , Átrios do Coração/cirurgia , Frequência Cardíaca , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/cirurgia , Medição de Risco , Fatores de Risco , Tromboembolia/diagnóstico , Tromboembolia/fisiopatologia , Resultado do Tratamento
6.
Int Heart J ; 58(6): 880-884, 2017 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-29151478

RESUMO

Pulmonary vein isolation (PVI) is a cornerstone therapy for atrial fibrillation (AF). Although severe complications are rather rare, the development of an atrio-esophageal fistula (AEF) is a fatal complication with a very high mortality even after surgical treatment. The use of esophageal temperature probes (ETP) during PVI may protect the esophagus but it is still under debate since the ETP may also lead to esophageal lesions. The aim of this study was to evaluate the clinical safety of PVI using contact-force (CF) sensing catheter without esophageal temperature monitoring.We investigated 70 consecutive patients who underwent point-by-point PVI without usage of ETP and who underwent esophago-gastro-duodenoscopy (EGD) with detailed evaluation of the esophagus after the index PVI procedure. The operator attempted to keep CF within the 10-40 g range. The incidences of esophageal lesions (EDEL) detected by endoscopy were then analyzed.Two of 70 patients (2.9%) showed EDEL consisting of one longitudinal ulcer-like erythematous lesion with fibrin and a different one consisting of a round-shaped lesion surrounded by erythema and petechial hemorrhage. All EDEL healed within two weeks under high proton-pump inhibitor therapy without developing AEF as proven by a second EGD of the esophagus.Point-by-point PVI without usage of ETP showed a low incidence of EDEL (2.9%); atrio-esophageal fistula was absent. Further studies on the necessity of ETP under CF control are necessary.


Assuntos
Fibrilação Atrial/terapia , Ablação por Cateter/efeitos adversos , Doenças do Esôfago/etiologia , Idoso , Ablação por Cateter/métodos , Endoscopia Gastrointestinal , Doenças do Esôfago/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
7.
Int Heart J ; 58(2): 205-210, 2017 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-28321025

RESUMO

The use of a novel irrigated multipolar ablation and mapping catheter for pulmonary vein isolation in patients with atrial fibrillation (AF) has demonstrated reasonable acute success rates and short procedure times, however, long-term outcome data are limited. The aim of this study was to analyze the long-term efficacy of this novel ablation system utilizing a reduced power setting for safety purposes.A total of 89 patients with paroxysmal (63 of 89 patients; 71%) or persistent AF underwent PVI with a reduced power setting of maximum 20 Watts (W) unipolar radiofrequency energy and 30 seconds in duration. In cases of persistent AF, atrial substrate ablation was performed additionally. Follow-up was based on outpatient clinic visits at 3, 6, and 12 months and included 5-day Holter ECGs. All of the 347 identified pulmonary veins were successfully isolated. Mean procedure times in PVI and PVI plus substrate ablation were 102 ± 25 minutes and 126 ± 32 minutes, respectively, applying a mean total radiofrequency time of 14 ± 6 minutes and 19 ± 9 minutes. Mean fluoroscopy time was 17 ± 8 minutes and 18 ± 6 minutes, respectively. Follow-up was available for all 89 patients. At one-year follow-up, 44 (70%) patients with paroxysmal AF and 11 (42%) patients with persistent AF remained in stable sinus rhythm after a singleprocedure and off antiarrhythmic drugs.The use of a novel irrigated multipolar ablation catheter with a reduced power setting is safe and feasible, and demonstrates a one-year success rate of 70% in paroxysmal AF and 42% in persistent AF.


Assuntos
Fibrilação Atrial/terapia , Ablação por Cateter/métodos , Idoso , Ablação por Cateter/instrumentação , Ablação por Cateter/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares
8.
Int Heart J ; 57(3): 299-303, 2016 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-27181037

RESUMO

Pulmonary vein isolation (PVI) is a cornerstone therapy in patients with atrial fibrillation (AF). With increasing numbers of PVI procedures, demand arises to reduce the cumulative fluoroscopic radiation exposure for both the physician and the patient. New technologies are emerging to address this issue. Here, we report our first experiences with a new fluoroscopy integrating technology in addition to a current 3D-mapping system. The new fluoroscopy integrating system (FIS) with 3D-mapping was used prospectively in 15 patients with AF. Control PVI cases (n = 37) were collected retrospectively as a complete series. Total procedure time (skin to skin), fluoroscopic time, and dose-area-product (DAP) data were analyzed. All PVI procedures were performed by one experienced physician using a commercially available circular multipolar irrigated ablation catheter. All PVI procedures were successfully undertaken without major complications. Baseline characteristics of the two groups showed no significant differences. In the group using the FIS, the fluoroscopic time and DAP were significantly reduced from 571 ± 187 seconds versus 1011 ± 527 seconds (P = 0.0029) and 4342 ± 2073 cGycm(2) versus 6208 ± 3314 cGycm(2) (P = 0.049), respectively. Mean procedure time was not significantly affected and was 114 ± 31 minutes versus 104 ± 24 minutes (P = 0.23) by the FIS.The use of the new FIS with the current 3D-mapping system enables a significant reduction of the total fluoroscopy time and DAP compared to the previous combination of 3D-mapping system plus normal fluoroscopy during PVI utilizing a circular multipolar irrigated ablation catheter. However, the concomitant total procedure time is not affected. Thus, the new system reduces the radiation exposure for both the physicians and patients.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Fluoroscopia/métodos , Exposição Ocupacional/prevenção & controle , Veias Pulmonares/cirurgia , Doses de Radiação , Idoso , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Técnicas Eletrofisiológicas Cardíacas/métodos , Feminino , Humanos , Imageamento Tridimensional/métodos , Invenções , Masculino , Pessoa de Meia-Idade , Saúde Radiológica/métodos , Fatores de Tempo
9.
Artigo em Inglês | MEDLINE | ID: mdl-38985244

RESUMO

BACKGROUND AND AIMS: Wearable cardioverter defibrillator (WCD) can protect patients from sudden cardiac death due to ventricular tachyarrhythmias and serve as a bridge to decision of definite defibrillator implantation. The aim of this analysis from an international, multicenter WCD registry was to identify predictors of sustained ventricular tachycardia (VT) and/or ventricular fibrillation (VF) in this population. METHODS: One thousand six hundred seventy-five patients with WCD were included in a multicenter registry from 9 European centers, with a median follow-up of 440 days (IQR 120-893). The primary study end point was the occurrence of sustained VT/VF. RESULTS: Sustained VT was detected by WCD in 5.4% and VF in 0.9% of all patients. Of the 30.3% of patients receiving ICD implantation during follow-up, sustained VT was recorded in 9.3% and VF in 2.6%. Non-ischemic cardiomyopathy (HR 0.5, p < 0.001), and medication with angiotensin-converting enzyme inhibitors (HR 0.7, p = 0.027) and aldosterone antagonists (HR 0.7, p = 0.005) were associated with a significantly lower risk of VT/VF. CONCLUSIONS: Patients who received WCD due to a transient increased risk of sudden cardiac death have a comparatively lower risk of VT/VF in the presence of non-ischemic cardiomyopathy. Of note, optimal medical treatment for heart failure not only results in an improvement in left ventricular ejection fraction but also in a reduction in the risk for VT/VF.

10.
Cardiol J ; 30(1): 44-50, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-33634842

RESUMO

BACKGROUND: With the advent of novel recanalization techniques and emerging devices, percutaneous coronary intervention (PCI) has become a promising leading treatment option for patients with chronic total occlusions (CTO). The present study aims to evaluate the acute outcomes of PCI in previously failed re-attempted vs. first-attempted CTO-lesions. METHODS: Between 2012 and 2019, 619 patients were included and treated with PCI of at least one CTO. 253 patients were re-attempted lesions, while 366 were initially attempted lesions. RESULTS: Re-attempted lesions were more complex, including higher Japanese-CTO (J-CTO) score and the need for a retrograde approach. The procedure time and fluoroscopy time were longer in this group. Nevertheless, overall success rates were comparable between both groups of patients. In-hospital events were rare and without significant differences. CONCLUSIONS: Re-attempted CTO lesions are more complex than first-attempt lesions and are associated with longer procedural times. However, they can be safely intervened by experienced operators with a similar success rate.


Assuntos
Oclusão Coronária , Intervenção Coronária Percutânea , Humanos , Intervenção Coronária Percutânea/métodos , Fatores de Risco , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/cirurgia , Hospitais , Doença Crônica , Resultado do Tratamento , Angiografia Coronária/métodos , Sistema de Registros
11.
J Interv Card Electrophysiol ; 66(3): 567-575, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36038739

RESUMO

BACKGROUND: Pulsed field ablation (PFA) is a new, non-thermal technology in the treatment of atrial fibrillation (AF). Early investigations have shown a promising safety profile with durable pulmonary vein isolation (PVI) and large antral lesions. However, clinical data remains scarce. METHODS: We investigated a cohort of 43 patients. Twenty-three patients underwent PVI with PFA in our hospital and we analyzed them with regard to procedural characteristics and with regard to the size of acute antral lesion which was estimated by using an electroanatomical map of the left atrium (LA). We compared these data with data of 20 patients who had undergone cryoballon (CB) PVI in our hospital. RESULTS: We could show acute isolation of all veins in all patients (100% PFA, 100% CB). Post-ablation high-density mapping revealed no early reconnection (0%). The acute antral lesion size of PFA was significantly higher compared to the CB (67.03 ± 12.69% vs. 57.39 ± 10.91%, p = 0.01). In the PFA group, we found no acute phrenic nerve injury, no major or minor bleeding, and no tamponade but one (4.34%) patient suffered from a stroke. Transient hypotension was observed frequently as well as transient bradycardia or asystole episodes requiring right ventricular pacing. In the CB group, no complications occurred. Furthermore, we discuss practical issues on PFA procedures. CONCLUSIONS: PFA is a promising technology with high acute PV isolation rate and large antral lesions compared to CB. However, larger trials with more patients and data on long-term freedom of AF but also complications are needed.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Criocirurgia/métodos , Resultado do Tratamento , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Átrios do Coração/cirurgia , Ablação por Cateter/métodos , Recidiva
12.
Injury ; 54(7): 110829, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37246114

RESUMO

OBJECTIVES: Oral anticoagulation (OAC) may have an impact on mortality in cases hospitalized for hip fracture (HF). We studied nationwide time trends of OAC prescriptions and compared time trends of inhospital mortality of HF cases with and without OAC in Germany DESIGN: Retrospective cohort study SETTING: Nationwide German hospitalization, Diagnosis-Related Groups Statistic PATIENTS/PARTICIPANTS: All hospital admissions for HF 60 years and older in the years 2006 through 2020. INTERVENTION: Additional diagnosis with a personal history of long-term use of anticoagulants (ICD code Z92.1). MAIN OUTCOME MEASUREMENTS: Inhospital mortality RESULTS: Cases hospitalized for HF 60 years and older increased by 29.5%. In 2006, 5.6% had a documented history of long-term use of OACs. This proportion rose to 20.1% in 2020. Age-standardized hospitalization mortality in HF cases without long-term use of OACs in males decreased steadily from 8.6% (95% confidence intervals 8.2 - 8.9) in 2006 to 6.6% (6.3 - 6.9) in 2020 and in females from 5.2% (5.0 - 5.3) to 3.9% (3.7 - 4.0). Mortality of HF cases with long-term use of OACs remained unchanged: males 7.0% (5.7 - 8.2) in 2006 and 7.3% (6.7 - 7.8) in 2020, females 4.8% (4.1 - 5.4) and 5.0% (4.7 - 5.3). CONCLUSION: Inhospital mortality of HF cases with and without long-term OAC show different trends. In HF cases without OAC, mortality decreased from 2006 to 2020. In cases with OAC such a decrease could not be observed.


Assuntos
Fibrilação Atrial , Fraturas do Quadril , Acidente Vascular Cerebral , Masculino , Feminino , Humanos , Estudos Retrospectivos , Mortalidade Hospitalar , Hospitalização , Anticoagulantes/uso terapêutico
13.
Interv Neuroradiol ; : 15910199231197615, 2023 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-37671446

RESUMO

BACKGROUND: Length of stay is an important factor for managing the limited resources of a hospital. The early, accurate prediction of hospital length of stay leads to the optimized disposition of resources particularly in complex stroke treatment. OBJECTIVE: In the present study we evaluated different machine learning techniques in their ability to predict the length of stay of patients with stroke of the anterior circulation who were treated with thrombectomy. MATERIAL AND METHODS: This retrospective study evaluated four algorithms (support vector machine, generalized linear model, K-nearest neighbour and Random Forest) to predict the length of hospitalization of 113 patients with acute stroke who were treated with thrombectomy. Input variables encompassed baseline data at admission, as well as periprocedural and imaging data. Ten-fold cross-validation was used to estimate accuracy. The accuracy of the algorithms was checked with a test dataset. In addition to regression analysis, we performed a binary classification analysis to identify patients that stayed longer than the mean length of stay. RESULTS: Mean length of stay was 10.7 days (median 10, interquartile range 6-15). The sensitivity of the best-performing Random Forest model was 0.8, the specificity was 0.68 and the area under the curve was 0.73 in the classification analysis. The mean absolute error of the best-performing Random Forest Model was 4.6 days in the test dataset in the regression analysis. CONCLUSION: Machine learning has potential use to estimate the length of stay of patients with acute ischaemic stroke that were treated with thrombectomy.

14.
Clin Neuroradiol ; 33(3): 687-694, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36745214

RESUMO

PURPOSE: Whether patients presenting with mild stroke (NIHSS at admission < 6) should be treated with mechanical thrombectomy (MT) is the subject of an ongoing debate. This retrospective study based on large-scale clinical data aims to identify factors associated with favorable outcome (FO) in patients with mild stroke. METHODS: A total of 761 patients with mild stroke enrolled between 1 January 2020 and 31 December 2020 in the Quality Registry of the German Society for Neuroradiology were analyzed. The FO was defined as stable or improved NIHSS at discharge vs. admission. Descriptive statistics and multivariable logistic regression analyses were performed to identify factors associated with FO. Furthermore, a subgroup analysis of mild stroke based on distal vessel occlusion was conducted. RESULTS: In this study 610 patients had FO with a median NIHSS at discharge of 1 (interquartile range, IQR, 0-2) and 151 had an unfavorable outcome (UO) with median NIHSS at discharge of 10 (IQR 13). Patients with FO had a slightly higher NIHSS at admission (4 vs. 3, p < 0.001), lower mTICI 0 (2.7% vs. 14.2%, p < 0.001), higher mTICI 3 (61.3% vs. 34.5%, p < 0.001) and a lower number of passes (1 vs. 2, p < 0.001). No statistically significant difference was observed for MT-related adverse events. Multivariable logistic regression suggested that NIHSS at admission (adjusted odds ratio (aOR) = 1.28, 95% confidence interval (CI) = 1.10-1.48), mTICI 2b (aOR = 5.44, CI = 2.06-15.03), mTICI 2c (aOR = 10.81, CI = 3.65-34.07) and mTICI 3 (aOR = 11.56, CI = 4.49-31.10) as well as number of passes (aOR 0.76, CI = 0.66-0.88) were significantly associated with FO. No MT-related adverse events were observed for distal vessel occlusions. CONCLUSION: The FO in patients with mild stroke undergoing MT was associated with successful recanalization. No significant differences between patients with FO and UO were found for MT-related adverse events, suggesting that MT complications have no significant effects on the outcome of these patients. MT might improve the prognosis also in patients with mild stroke based on distal vessel occlusions without significantly increasing the risk of adverse events.


Assuntos
Isquemia Encefálica , Acidente Vascular Cerebral , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/cirurgia , Acidente Vascular Cerebral/etiologia , Trombectomia/efeitos adversos , Sistema de Registros , Isquemia Encefálica/terapia
15.
J Am Heart Assoc ; 12(18): e030615, 2023 09 19.
Artigo em Inglês | MEDLINE | ID: mdl-37681569

RESUMO

Background Data on the use of the wearable cardioverter-defibrillator (WCD) among patients with myocarditis remain sparse. Consequently, evidence for guideline recommendations in this patient population is lacking. Methods and Results In total, 1596 consecutive patients were included in a multicenter registry from 8 European centers, with 124 patients (8%) having received the WCD due to myocarditis and reduced left ventricular ejection fraction or prior ventricular tachyarrhythmia. The mean age was 51.6±16.3 years, with 74% being male. Patients were discharged after index hospitalization on heart failure medication: Angiotensin-converting enzyme inhibitors (62.5%), angiotensin-receptor-neprilysin inhibitor (22.9%), aldosterone-antagonists (51%), or beta blockers (91.4%). The initial median left ventricular ejection fraction was 30% (22%-45%) and increased to 48% (39%-55%) over long-term follow-up (P<0.001). The median BNP (brain natriuretic peptide) level at baseline was 1702 pg/mL (565-3748) and decreased to 188 pg/mL (26-348) over long-term follow-up (P=0.022). The mean wear time was 79.7±52.1 days and 21.0±4.9 hours per day. Arrhythmic event rates documented by the WCD were 9.7% for nonsustained ventricular tachycardia, 6.5% for sustained ventricular tachycardia, and 0% for ventricular fibrillation. Subsequently, 2.4% of patients experienced an appropriate WCD shock. The rate of inappropriate WCD shocks was 0.8%. All 3 patients with appropriate WCD shock had experienced ventricular tachycardia/ventricular fibrillation before WCD prescription, with only 1 patient showing a left ventricular ejection fraction <35%. Conclusions Patients with myocarditis and risk for occurrence of ventricular tachyarrhythmia may benefit from WCD use. Prior ventricular arrhythmia might appear as a better risk predictor than a reduced left ventricular ejection fraction <35% in this population.


Assuntos
Miocardite , Taquicardia Ventricular , Dispositivos Eletrônicos Vestíveis , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Volume Sistólico , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/terapia , Função Ventricular Esquerda , Miocardite/complicações , Miocardite/terapia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Desfibriladores
16.
J Basic Microbiol ; 52(3): 269-76, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21780151

RESUMO

40-O -[2-Hydroxyethyl]rapamycin (RAD), a novel derivative of the immunosuppressive drug rapamycin, was analyzed for its immunomodulatory influence during the interaction of human monocyte-derived dendritic cells (moDC) with Aspergillus fumigatus. RAD is clinically used to prevent graft-versus -host disease as well as solid organ and bone marrow transplant rejection. However, it may constitute a risk factor for the development of opportunistic infections, such as invasive aspergillosis which is mainly caused by the most common airborne fungal pathogen A. fumigatus. moDC were generated in the presence or absence of RAD. In this setting, RAD had various modulating effects on the immune function of DC. A decrease of pro- and anti-inflammatory cytokines (IL-12, TNF-α, CCL20, IL-10) was observed. Furthermore, RAD reduced the expression of innate immunity receptors (TLR2, TLR4, dectin-1), impaired the maturation capacity of moDC observed through the reduction of costimulatory factors (CD40, CD80, CD83, CD86), and impaired their capacity to phagocytose and damage A. fumigatus. These data demonstrate that RAD influences the differentiation of DC. RAD modulates the cytokine response of DC to A. fumigatus and reduces their ability to kill germ tubes. Thus, RAD treatment might affect the risk of invasive aspergillosis independently of its capacity of blocking T cell activation.


Assuntos
Aspergillus fumigatus/imunologia , Células Dendríticas/efeitos dos fármacos , Células Dendríticas/imunologia , Imunossupressores/metabolismo , Sirolimo/análogos & derivados , Antígenos CD/metabolismo , Diferenciação Celular/efeitos dos fármacos , Citocinas/antagonistas & inibidores , Citocinas/metabolismo , Células Dendríticas/fisiologia , Everolimo , Experimentação Humana , Humanos , Receptores Imunológicos/antagonistas & inibidores , Receptores Imunológicos/biossíntese , Sirolimo/metabolismo
17.
J Belg Soc Radiol ; 106(1): 18, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35581972

RESUMO

Purpose: To evaluate the detection rate of intracranial aneurysms on reconstructed thin slice non enhanced CT (NECT) scans. Methods: NECT scans from 34 patients with 35 aneurysms and 35 individuals without aneurysms were collected. Thin slice maximum intensity projections of the NECT scans were reconstructed. One observer evaluated the native images twice with a time interval of six month between both passes with respect to the prevalence and location of an aneurysm. The size and location of the aneurysms were evaluated in corresponding CT-Angiography and Time of flight datasets. A logit regression analysis was performed with size and location as dependent variables. 2 × 2 tables were constructed. The sensitivity and false negative rate were calculated for aneurysms with 0-6.9 mm, 7-9.9 mm and 10-20 mm and the under the curve (AUC) was calculated. Results: The overall detection rate of the aneurysms was 63% for the first pass and 66% for the second pass in the reconstructed NECT scans. The detection rate of aneurysms is size dependent. The sensitivity to detect aneurysms with a size of 0-6.9 mm was 0.09 and 0.03, for aneurysms with a size of 7-9.9. mm was 0.8 and 0.7 and for aneurysms with a size of 10-20 mm was 0.92 for both passes.The AUC was 0.77 for the first pass and 0.78 for the second pass. Conclusions: NECT scans can be used to detect a significant proportion of intracranial aneurysms larger than 7 mm if properly displayed and reconstructed. These patients should receive further vascular imaging to prevent future aneurysm related subarachnoid hemorrhage.

18.
J Cardiovasc Dev Dis ; 9(6)2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35735804

RESUMO

BACKGROUND: Wearable cardioverter-defibrillators (WCDs) are a well-established tool to bridge the recovery time of left ventricular ejection fraction (LVEF) until the implantation of an implantable cardioverter defibrillator (ICD), as recommended by the current guidelines. Besides their function to detect and treat malignant arrhythmias, WCDs may be used as a telemonitoring system. In this study, we sought to illustrate and discuss the telemonitoring potential of WCDs and to analyze physical activity in specific patient cohorts. METHODS AND RESULTS: We retrospectively included 140 patients with reduced LVEF who were prescribed WCDs in our clinic. We analyzed the patients' physical activity (n = 105 with a WCD compliance above 21 h/day), body position and resting position. We found a reduced physical activity in women and in patients over the age of 65 compared to younger patients. Furthermore, the patients who were overweight or obese showed significantly reduced physical activity compared to the patients with a normal weight (6365 ± 3572 vs. 4972 ± 2476 vs. 7045 ± 3521, p = 0.02). CONCLUSION: WCDs may be used as a telemonitoring and intervention tool in patients with reduced LVEF. Specific patient groups may benefit from guidance from their treating physician regarding physical activity.

19.
Interv Neuroradiol ; : 15910199221135695, 2022 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-36344011

RESUMO

PURPOSE: Outcome prediction of large vessel occlusion of the anterior circulation in patients with wake-up stroke is important to identify patients that will benefit from thrombectomy. Currently, mismatch concepts that require MRI or CT-Perfusion (CTP) are recommended to identify these patients. We evaluated machine learning algorithms in their ability to discriminate between patients with favorable (defined as a modified Rankin Scale (mRS) score of 0-2) and unfavorable (mRS 3-6) outcome and between patients with poor (mRS5-6) and non-poor (mRS 0-4) outcome. METHODS: Data of 8395 patients that were treated between 2018 and 2020 from the nationwide registry of the German Society for Neuroradiology was retrospectively analyzed. Five models were trained with clinical variables and Alberta Stroke Program Early CT Score (ASPECTS). The model with the highest accuracy was validated with a test dataset with known stroke onset and with a test dataset that consisted only of wake-up strokes. RESULTS: 2419 patients showed poor and 3310 patients showed favorable outcome. The best performing Random Forest model achieved a sensitivity of 0.65, a specificity of 0.81 and an AUC of 0.79 on the test dataset of patients with wake-up stroke in the classification analysis between favorable and unfavorable outcome and a sensitivity of 0.42, a specificity of 0.83 and an AUC of 0.72 in the classification analysis between poor and non-poor outcome. CONCLUSION: Machine learning algorithms have the potential to aid in the decision making for thrombectomy in patients with wake-up stroke especially in hospitals, where emergency CTP or MRI imaging is not available.

20.
Int J Cardiol Heart Vasc ; 38: 100942, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35079620

RESUMO

BACKGROUND: The new EuroCTO CASTLE Score was validated against the widely adopted Japanese Multicenter CTO Registry (J-CTO) score in predicting technical success in percutaneous coronary intervention (PCI) for coronary chronic total occlusions (CTO). METHODS: A total of 463 patients treated by CTO PCI were included in a retrospective analysis. Result: The mean CASTLE score was 2.23 ± 1.1 and J-CTO score was 2.84 ± 1.0. The overall technical success rate was 83.2%. At 30 days follow up, a primary composite safety endpoint showed a low proportion of stent thrombosis (0.2%) and re-hospitalization (0.4%). Moreover, an improvement of clinical symptoms was found in 83% of patients. Receiver operating characteristic analysis (ROC) demonstrated a comparable overall discriminatory performance in predicting technical outcome: CASTLE score, area under the ROC curve (AUC) 0.668, 95% CI: 0.606-0.730; J-CTO score AUC 0.692, 95% CI: 0.631-0.752; Comparison of AUCs: p = 0.324. Those findings were even consistent in more complex procedures CASTLE Score ≥ 4 and J-CTO score ≥ 3: CASTLE Score AUC 0.514, 95% CI: 0.409-0.619; J-CTO score, AUC 0.617, 95% CI: 0.493-0.741; Comparison of AUCs: p = 0.211. Furthermore, increasing score values are accompanied by a longer examination and fluoroscopy time, more contrast medium and a higher dose area product. CONCLUSION: Compared to the widely accepted J-CTO score, the new introduced EuroCTO CASTLE score demonstrated a comparable overall discriminatory performance in predicting technical outcomes in CTO PCI.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA