Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
J Orthop Traumatol ; 25(1): 21, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38637406

RESUMO

BACKGROUND: Treating tibial non-unions efficiently presents a challenge for orthopaedic trauma surgeons. The established gold standard involves implanting autologous bone graft with adequate fixation, but the addition of biologicals according to the so-called diamond concept has become increasingly popular in the treatment of non-unions. Previous studies have indicated that polytherapy, which involves implanting mesenchymal stem cells, bioactive factors and osteoconductive scaffolds, can improve bone healing. This study aims to evaluate the efficacy of polytherapy compared with monotherapy in treating tibial non-unions of varying severity. MATERIALS AND METHODS: Data from consecutive tibial non-unions treated between November 2014 and July 2023 were retrospectively analysed. The Non Union Scoring System (NUSS) score before non-union surgery, and the Radiographic Union Score for Tibial fractures (RUST), scored at 1, 3, 6, 9, 12 and 18 months post-surgery, were recorded. Initially, a comparison was made between the polytherapy and monotherapy groups. Subsequently, patients receiving additional surgical non-union treatment were documented, and the frequency of these treatments was tallied for a subsequent per-treatment analysis. RESULTS: A total of 34 patients were included and divided into a polytherapy group (n = 15) and a monotherapy group (n = 19). The polytherapy group demonstrated a higher NUSS score (44 (39, 52) versus 32 (29, 43), P = 0.019, z = -2.347) and a tendency towards a higher success rate (93% versus 68%, P = 0.104) compared with the monotherapy group. For the per-treatment analysis, 44 treatments were divided into the polytherapy per-treatment group (n = 20) and the monotherapy per-treatment group (n = 24). The polytherapy per-treatment group exhibited a higher NUSS score (48 (43, 60) versus 38 (30, 50), P = 0.030, z = -2.173) and a higher success rate (95% versus 58%, P = 0.006) than the monotherapy per-treatment group. Within the monotherapy per-treatment group, the NUSS score displayed excellent predictive performance (AUC = 0.9143). Setting the threshold value at 48, the sensitivity and specificity were 100.0% and 70.0%, respectively. CONCLUSIONS: Polytherapy is more effective than monotherapy for severe tibial non-unions, offering a higher success ratio. The NUSS score supports decision-making in treating tibial non-unions. LEVEL OF EVIDENCE: Level III.


Assuntos
Fraturas não Consolidadas , Fraturas da Tíbia , Humanos , Estudos Retrospectivos , Fraturas não Consolidadas/terapia , Consolidação da Fratura , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia , Transplante Ósseo , Resultado do Tratamento
2.
Sensors (Basel) ; 21(16)2021 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-34450927

RESUMO

Microwave-based sensing for tissue analysis is recently gaining interest due to advantages such as non-ionizing radiation and non-invasiveness. We have developed a set of transmission sensors for microwave-based real-time sensing to quantify muscle mass and quality. In connection, we verified the sensors by 3D simulations, tested them in a laboratory on a homogeneous three-layer tissue model, and collected pilot clinical data in 20 patients and 25 healthy volunteers. This report focuses on initial sensor designs for the Muscle Analyzer System (MAS), their simulation, laboratory trials and clinical trials followed by developing three new sensors and their performance comparison. In the clinical studies, correlation studies were done to compare MAS performance with other clinical standards, specifically the skeletal muscle index, for muscle mass quantification. The results showed limited signal penetration depth for the Split Ring Resonator (SRR) sensor. New sensors were designed incorporating Substrate Integrated Waveguides (SIW) and a bandstop filter to overcome this problem. The sensors were validated through 3D simulations in which they showed increased penetration depth through tissue when compared to the SRR. The second-generation sensors offer higher penetration depth which will improve clinical data collection and validation. The bandstop filter is fabricated and studied in a group of volunteers, showing more reliable data that warrants further continuation of this development.


Assuntos
Micro-Ondas , Músculos , Simulação por Computador , Humanos
3.
Sensors (Basel) ; 21(6)2021 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-33809710

RESUMO

Manual segmentation of muscle and adipose compartments from computed tomography (CT) axial images is a potential bottleneck in early rapid detection and quantification of sarcopenia. A prototype deep learning neural network was trained on a multi-center collection of 3413 abdominal cancer surgery subjects to automatically segment truncal muscle, subcutaneous adipose tissue and visceral adipose tissue at the L3 lumbar vertebral level. Segmentations were externally tested on 233 polytrauma subjects. Although after severe trauma abdominal CT scans are quickly and robustly delivered, with often motion or scatter artefacts, incomplete vertebral bodies or arms that influence image quality, the concordance was generally very good for the body composition indices of Skeletal Muscle Radiation Attenuation (SMRA) (Concordance Correlation Coefficient (CCC) = 0.92), Visceral Adipose Tissue index (VATI) (CCC = 0.99) and Subcutaneous Adipose Tissue Index (SATI) (CCC = 0.99). In conclusion, this article showed an automated and accurate segmentation system to segment the cross-sectional muscle and adipose area L3 lumbar spine level on abdominal CT. Future perspectives will include fine-tuning the algorithm and minimizing the outliers.


Assuntos
Aprendizado Profundo , Traumatismo Múltiplo , Tecido Adiposo/diagnóstico por imagem , Estudos Transversais , Humanos , Traumatismo Múltiplo/diagnóstico por imagem , Músculo Esquelético/diagnóstico por imagem , Tomografia Computadorizada por Raios X
4.
Anesthesiology ; 132(3): 424-439, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31743149

RESUMO

BACKGROUND: Vital signs are usually recorded once every 8 h in patients at the hospital ward. Early signs of deterioration may therefore be missed. Wireless sensors have been developed that may capture patient deterioration earlier. The objective of this study was to determine whether two wearable patch sensors (SensiumVitals [Sensium Healthcare Ltd., United Kingdom] and HealthPatch [VitalConnect, USA]), a bed-based system (EarlySense [EarlySense Ltd., Israel]), and a patient-worn monitor (Masimo Radius-7 [Masimo Corporation, USA]) can reliably measure heart rate (HR) and respiratory rate (RR) continuously in patients recovering from major surgery. METHODS: In an observational method comparison study, HR and RR of high-risk surgical patients admitted to a step-down unit were simultaneously recorded with the devices under test and compared with an intensive care unit-grade monitoring system (XPREZZON [Spacelabs Healthcare, USA]) until transition to the ward. Outcome measures were 95% limits of agreement and bias. Clarke Error Grid analysis was performed to assess the ability to assist with correct treatment decisions. In addition, data loss and duration of data gaps were analyzed. RESULTS: Twenty-five high-risk surgical patients were included. More than 700 h of data were available for analysis. For HR, bias and limits of agreement were 1.0 (-6.3, 8.4), 1.3 (-0.5, 3.3), -1.4 (-5.1, 2.3), and -0.4 (-4.0, 3.1) for SensiumVitals, HealthPatch, EarlySense, and Masimo, respectively. For RR, these values were -0.8 (-7.4, 5.6), 0.4 (-3.9, 4.7), and 0.2 (-4.7, 4.4) respectively. HealthPatch overestimated RR, with a bias of 4.4 (limits: -4.4 to 13.3) breaths/minute. Data loss from wireless transmission varied from 13% (83 of 633 h) to 34% (122 of 360 h) for RR and 6% (47 of 727 h) to 27% (182 of 664 h) for HR. CONCLUSIONS: All sensors were highly accurate for HR. For RR, the EarlySense, SensiumVitals sensor, and Masimo Radius-7 were reasonably accurate for RR. The accuracy for RR of the HealthPatch sensor was outside acceptable limits. Trend monitoring with wearable sensors could be valuable to timely detect patient deterioration.


Assuntos
Monitorização Intraoperatória/instrumentação , Sinais Vitais , Dispositivos Eletrônicos Vestíveis , Idoso , Cuidados Críticos , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/métodos , Monitorização Fisiológica , Oximetria/instrumentação , Oximetria/métodos , Reprodutibilidade dos Testes , Taxa Respiratória , Resultado do Tratamento , Tecnologia sem Fio
5.
J Orthop Traumatol ; 20(1): 20, 2019 04 11.
Artigo em Inglês | MEDLINE | ID: mdl-30976999

RESUMO

BACKGROUND: The incidence of hip fractures is increasing. Elderly patients with a hip fracture frequently present with comorbidities, which are associated with higher mortality rates. Clinical studies regarding long-term functional outcome and mortality in hip fractures are rare. The aim of this study was to analyse the functional outcome and the mortality rate after a follow-up of 5 years in elderly patients with a hip fracture. MATERIALS AND METHODS: This combined retrospective and cross-sectional study included patients aged 65 years or older with a low energy hip fracture who underwent surgery in the Maastricht University Medical Center+, the Netherlands. Data such as demographics and mortality rates were retrospectively collected and functional outcome (i.e. mobility, pain, housing conditions and quality of life) was assessed by a questionnaire. RESULTS: Two hundred and sixteen patients were included in this study (mean age 82.2, SD ± 7.5). No significant differences were found in pain before hip fracture and after 1-year and 5-year follow-ups. Long-term functional outcome deteriorated after a hip fracture, with a significant increase in the use of walking aids (p < 0.001), a significant decrease of patients living in a private home (p < 0.001), and a low physical quality of life (SF-12 PCS = 27.1). The mortality incidences after 30-day, 1-year and 5-year follow-ups were 7.9%, 37.0% and 69.4%, respectively. CONCLUSION: Long-term functional outcome in elderly patients with hip fractures significantly deteriorated, with an increased dependency for mobility and housing conditions and a decreased physical quality of life. In addition, hip fractures are associated with high mortality rates at the 5-year follow-up. LEVEL OF EVIDENCE: Level III, a retrospective cohort study.


Assuntos
Fixação Interna de Fraturas/métodos , Fraturas do Quadril/cirurgia , Qualidade de Vida , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Feminino , Seguimentos , Fraturas do Quadril/psicologia , Humanos , Masculino , Estudos Retrospectivos , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento
6.
BMC Surg ; 18(1): 8, 2018 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-29391063

RESUMO

BACKGROUND: The standard aftercare treatment in surgically treated trauma patients with fractures around or in a joint, known as (peri)- or intra-articular fractures of the lower extremities, is either non-weight bearing or partial weight bearing. We have developed an early permissive weight bearing post-surgery rehabilitation protocol in surgically treated patients with fractures of the lower extremities. In this proposal we want to compare our early permissive weight bearing protocol to the existing current non-weight bearing guidelines in a prospective comparative cohort study. METHODS/DESIGN: The study is a prospective multicenter comparative cohort study in which two rehabilitation aftercare treatments will be contrasted, i.e. permissive weight bearing and non-weight bearing according to the AO-guideline. The study population consists of patients with a surgically treated fracture of the pelvis/acetabulum or a surgically treated (peri)- or intra-articular fracture of the lower extremities. The inclusion period is 12 months. The duration of follow up is 6 months, with measurements taken at baseline, 2,6,12 and 26 weeks post-surgery. PRIMARY OUTCOME MEASURE: ADL with Lower Extremity Functional Scale. Outcome variables for compliance, as measured with an insole pressure measurement system, encompass peak load and step duration. DISCUSSION: This study will investigate the (cost-) effectiveness of a permissive weight bearing aftercare protocol. The results will provide evidence whether a permissive weight bearing protocol is more effective than the current non-weight bearing protocol. TRIAL REGISTRATION: The study is registered in the Dutch Trial Register ( NTR6077 ). Date of registration: 01-09-2016.


Assuntos
Fraturas Ósseas/cirurgia , Fraturas Intra-Articulares/cirurgia , Adulto , Feminino , Humanos , Extremidade Inferior , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento , Suporte de Carga
7.
Sensors (Basel) ; 18(2)2018 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-29466312

RESUMO

In recent research, microwave sensors have been used to follow up the recovery of lower extremity trauma patients. This is done mainly by monitoring the changes of dielectric properties of lower limb tissues such as skin, fat, muscle, and bone. As part of the characterization of the microwave sensor, it is crucial to assess the signal penetration in in vivo tissues. This work presents a new approach for investigating the penetration depth of planar microwave sensors based on the Split-Ring Resonator in the in vivo context of the femoral area. This approach is based on the optimization of a 3D simulation model using the platform of CST Microwave Studio and consisting of a sensor of the considered type and a multilayered material representing the femoral area. The geometry of the layered material is built based on information from ultrasound images and includes mainly the thicknesses of skin, fat, and muscle tissues. The optimization target is the measured S11 parameters at the sensor connector and the fitting parameters are the permittivity of each layer of the material. Four positions in the femoral area (two at distal and two at thigh) in four volunteers are considered for the in vivo study. The penetration depths are finally calculated with the help of the electric field distribution in simulations of the optimized model for each one of the 16 considered positions. The numerical results show that positions at the thigh contribute the highest penetration values of up to 17.5 mm. This finding has a high significance in planning in vitro penetration depth measurements and other tests that are going to be performed in the future.

8.
Sensors (Basel) ; 18(9)2018 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-30134629

RESUMO

In this paper, we investigate the use of fat tissue as a communication channel between in-body, implanted devices at R-band frequencies (1.7⁻2.6 GHz). The proposed fat channel is based on an anatomical model of the human body. We propose a novel probe that is optimized to efficiently radiate the R-band frequencies into the fat tissue. We use our probe to evaluate the path loss of the fat channel by studying the channel transmission coefficient over the R-band frequencies. We conduct extensive simulation studies and validate our results by experimentation on phantom and ex-vivo porcine tissue, with good agreement between simulations and experiments. We demonstrate a performance comparison between the fat channel and similar waveguide structures. Our characterization of the fat channel reveals propagation path loss of ∼0.7 dB and ∼1.9 dB per cm for phantom and ex-vivo porcine tissue, respectively. These results demonstrate that fat tissue can be used as a communication channel for high data rate intra-body networks.


Assuntos
Tecido Adiposo , Eletrônica/métodos , Próteses e Implantes , Animais , Corpo Humano , Humanos , Modelos Anatômicos , Imagens de Fantasmas , Suínos
9.
Sensors (Basel) ; 17(3)2017 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-28327505

RESUMO

BACKGROUND: A variety of techniques for measuring lower limb loading exists, each with their own limitations. A new ambulatory biofeedback system was developed to overcome these limitations. In this study, we described the technical aspects and validated the accuracy of this system. METHODS: A bench press was used to validate the system in the static situation. Ten healthy volunteers were measured by the new biofeedback system and a dual-belt instrumented treadmill to validate the system in the dynamic situation. RESULTS: Bench press results showed that the sensor accurately measured peak loads up to 1000 N in the static situation. In the healthy volunteers, the load curves measured by the biofeedback system were similar to the treadmill. However, the peak loads and loading rates were lower in the biofeedback system in all participants at all speeds. CONCLUSIONS: Advanced sensor technologies used in the new biofeedback system resulted in highly accurate measurements in the static situation. The position of the sensor and the design of the biofeedback system should be optimized to improve results in the dynamic situation.


Assuntos
Biorretroalimentação Psicológica , Teste de Esforço , Terapia por Exercício , Humanos , Extremidade Inferior , Suporte de Carga
10.
Clin Immunol ; 164: 78-84, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26854617

RESUMO

The role of inflammatory cells in bone regeneration remains unclear. We hypothesize that leukocytes contribute to fracture healing by rapidly synthesizing an "emergency extracellular matrix (ECM)" before stromal cells infiltrate the fracture hematoma (FH) and synthesize the eventual collagenous bone tissue. 53 human FHs were isolated at different time points after injury, ranging from day 0 until day 23 after trauma and stained using (immuno)histochemistry. FHs isolated within 48 h after injury contained fibronectin(+) ECM, which increased over time. Neutrophils within the early FHs stained positive for cellular fibronectin and neutrophil derived particles were visible within the fibronectin(+) ECM. Stromal cells appeared at day 5 after injury or later and collagen type I birefringent fibrils could be identified during the second week after injury. Our study suggests that neutrophils contribute to bone regeneration by synthesizing an "emergency ECM" before stromal cells infiltrate the FH and synthesize the eventual bone tissue.


Assuntos
Matriz Extracelular/imunologia , Fibronectinas/imunologia , Consolidação da Fratura/imunologia , Neutrófilos/imunologia , Adulto , Contagem de Células , Feminino , Hematoma/imunologia , Humanos , Masculino , Pessoa de Meia-Idade
11.
Eur J Trauma Emerg Surg ; 50(1): 315-326, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37646799

RESUMO

PURPOSE: Recently, a surgical suction filter device was introduced which aims at generating a suction filter-derived bone grafting substitute (SF-BGS). The osteogenic capacity of this grafting material, however, is unclear. MicroRNAs (miRNAs) and osteogenic mRNAs may influence these processes. The aim of this study was therefore to investigate the quality of the SF-BGS by determining the expression of miRNAs and osteogenic mRNAs. METHODS: Samples were collected during non-union surgery. Upon exposure of the intramedullary canal, the surgical vacuum system was fitted with the suction filter device containing collagen complex and synthetic ß-TCP: (Ca3(PO4)2, granule size 5-8 mm, total volume 10 mL (Cerasorb Foam®, Curasan AG, Kleinostheim, Germany). As a control, venous blood was used as in current clinical practice. Samples were snap-frozen and mechanically disrupted. MiRNAs and mRNAs were isolated, transcribed, and pooled for qPCR analysis. Lastly, mRNA targets were determined through in silico target analyses. RESULTS: The study population consisted of seven patients with a posttraumatic long bone non-union (4♀; mean age 54 ± 16 years). From the array data, distinct differences in miRNA expression were found between the SF-BGS and control samples. Osteogenic marker genes were overall upregulated in the SF-BGS. Qiagen IPA software identified 1168 mRNA targets for 43 of the overall deregulated miRNAs. CONCLUSION: This study revealed distinctly deregulated and exclusively expressed osteogenic miRNAs in SF-BGS, as well as overall enhanced osteogenic marker gene expression, as compared to the venous blood control group. These expression profiles were not seen in control samples, indicating that the derived material displays an osteogenic profile. It may therefore be a promising tool to generate a BGS or graft extender when needed.


Assuntos
Substitutos Ósseos , MicroRNAs , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , MicroRNAs/genética , MicroRNAs/metabolismo , RNA Mensageiro/genética , RNA Mensageiro/metabolismo , Transplante Ósseo , Sucção , Osso e Ossos , Substitutos Ósseos/farmacologia
12.
Bone ; 181: 117021, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38253189

RESUMO

PURPOSE: This review aims to provide an overview of the multiple functions of neutrophils, with the recognition of the inflammatory (N1) and regenerative (N2) phenotypes, in relation to fracture healing. METHODS: A literature search was performed using the PubMed database. The quality of the articles was evaluated using critical appraisal checklists. RESULTS: Thirty one studies were included in this review. These studies consistently support that neutrophils exert both beneficial and detrimental effects on bone regeneration, influenced by Tumor Necrosis Factor-α (TNF-α), Interleukin 8 (IL-8), mast cells, and macrophages. The N2 phenotype has recently emerged as one promoter of bone healing. The N1 phenotype has progressively been connected with inflammatory neutrophils during fracture healing. CONCLUSIONS: This review has pinpointed various aspects and mechanisms of neutrophil influence on bone healing. The recognition of N1 and N2 neutrophil phenotypes potentially shed new light on the dynamic shifts taking place within the Fracture Hematoma (FH).


Assuntos
Fraturas Ósseas , Neutrófilos , Humanos , Neutrófilos/patologia , Regeneração Óssea , Consolidação da Fratura , Fraturas Ósseas/patologia , Fenótipo
13.
Bone Joint Res ; 13(5): 214-225, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38699779

RESUMO

Aims: The aim of this study was to determine the fracture haematoma (fxH) proteome after multiple trauma using label-free proteomics, comparing two different fracture treatment strategies. Methods: A porcine multiple trauma model was used in which two fracture treatment strategies were compared: early total care (ETC) and damage control orthopaedics (DCO). fxH was harvested and analyzed using liquid chromatography-tandem mass spectrometry. Per group, discriminating proteins were identified and protein interaction analyses were performed to further elucidate key biomolecular pathways in the early fracture healing phase. Results: The early fxH proteome was characterized by immunomodulatory and osteogenic proteins, and proteins involved in the coagulation cascade. Treatment-specific proteome alterations were observed. The fxH proteome of the ETC group showed increased expression of pro-inflammatory proteins related to, among others, activation of the complement system, neutrophil functioning, and macrophage activation, while showing decreased expression of proteins related to osteogenesis and tissue remodelling. Conversely, the fxH proteome of the DCO group contained various upregulated or exclusively detected proteins related to tissue regeneration and remodelling, and proteins related to anti-inflammatory and osteogenic processes. Conclusion: The early fxH proteome of the ETC group was characterized by the expression of immunomodulatory, mainly pro-inflammatory, proteins, whereas the early fxH proteome of the DCO group was more regenerative and osteogenic in nature. These findings match clinical observations, in which enhanced surgical trauma after multiple trauma causes dysbalanced inflammation, potentially leading to reduced tissue regeneration, and gained insights into regulatory mechanisms of fracture healing after severe trauma.

14.
Clin Orthop Relat Res ; 471(9): 2790-6, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23229434

RESUMO

BACKGROUND: Segmental tibial fractures are considered to be a special injury type associated with high complication rates. However, it is unclear whether healing of these fractures truly differs from that of nonsegmental fractures. QUESTIONS/PURPOSES: We therefore asked (1) does the time to union in segmental tibial fractures differ from that of nonsegmental fractures; and (2) does the complication rate of segmental fractures differ from that of nonsegmental fractures? METHODS: We retrospectively studied 30 patients with segmental tibial fractures treated at a Level I trauma center from January 2000 to December 2008 and compared healing and complications with a matched control group of 30 nonsegmental tibial fractures. In followup we determined time to union, delayed and nonunion, and overall complication rates. Patients were followed at least until union was attained. The minimum followup was 5 months (median, 15 months; range, 5-54 months). RESULTS: Median time to union was 34 weeks (range, 12-122 weeks). Segmental fractures took longer to heal than nonsegmental fractures (median, 34 weeks; range, 12-122 weeks and median, 24 weeks; range, 11-39 weeks, respectively). The overall rate of complications was higher in segmental fractures as was the necessity for reoperation to attain healing. CONCLUSIONS: Healing of segmental tibial fractures is characterized by substantially more complications and longer healing times than nonsegmental fractures and should be considered as a special type of injury. We believe these should be treated in specialized trauma centers.


Assuntos
Consolidação da Fratura , Fraturas Expostas/cirurgia , Tíbia/cirurgia , Fraturas da Tíbia/cirurgia , Adolescente , Adulto , Idoso , Feminino , Fraturas Expostas/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Reoperação , Estudos Retrospectivos , Tíbia/diagnóstico por imagem , Fraturas da Tíbia/diagnóstico por imagem , Resultado do Tratamento
15.
Arch Orthop Trauma Surg ; 133(8): 1109-13, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23700225

RESUMO

BACKGROUND: Intramedullary fixation is the treatment of choice for diaphyseal fractures of the femur and tibia. Locking the implant can sometimes be cumbersome and time consuming. In our institution, fractures with axial and rotational stability are treated with intramedullary nailing without interlocking. METHODS: All consecutive patients presented in the University Medical Center Utrecht from October 2003 to August 2009 with acute traumatic diaphyseal fractures of the tibia or femur that were considered axial and rotational stable were included. They underwent internal fixation using intramedullary nails without interlocking. Patient records were evaluated for duration of surgery, perioperative complications, consolidation time and re-operations. RESULTS: Twenty-nine long bone fractures were treated in 27 patients: 20 men and 7 women, with an average age of 28.9 years (range 15.6-54.4). There were 12 femoral fractures and 17 tibial fractures. Sixteen fractures were closed and 13 were open (10 Gustilo 1, 3 Gustilo 2). The mean operating time was 43 min (range 18-68 min) for tibial fractures and 55 min (range 47-150 min) for femoral fractures. Postoperative complications occurred in six patients. Two patients (three fractures) were lost to follow-up. Healing occurred in 25 of the 26 remaining fractures (96 %) without additional interventions. One tibia was secondarily converted to a standard locked nail because of axial and rotational instability. All patients returned to their pre-injury level of activity. CONCLUSION: The use of intramedullary nailing without interlocking is associated with minimal complications in selected fractures. The advantages include a short operating time and the simplicity of its application.


Assuntos
Pinos Ortopédicos , Parafusos Ósseos , Fraturas do Fêmur/cirurgia , Fixação Intramedular de Fraturas/instrumentação , Fraturas da Tíbia/cirurgia , Adolescente , Adulto , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
16.
Life (Basel) ; 13(3)2023 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-36983847

RESUMO

Innovative techniques can help overcome the limitations of the human body. Operating on very small structures requires adequate vision of the surgical field and precise movements of sophisticated instruments. Both the human eye and hand are limited when performing microsurgery. Conventional microsurgery uses operation microscopes to enhance the visualization of very small structures. Evolving technology of high-definition 3D cameras provides the opportunity to replace conventional operation microscopes, thereby improving ergonomics for surgeons. This leaves the human hand as a limiting factor in microsurgery. A dedicated robot for microsurgery has been developed to overcome this limitation and enhance the precision and stability of the surgeons' hands. We present the first-in-human case in reconstructive microsurgery where both technologies are integrated using a dedicated microsurgical robot in combination with a 4K 3D exoscope.

17.
Clin Nutr ESPEN ; 57: 617-623, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37739714

RESUMO

BACKGROUND: During Intensive Care Unit (ICU) admission, patients demonstrate up to 15% muscle loss per week, contributing to neuromuscular weakness, complicating recovery and delaying return to daily life. Biomarkers for muscle loss could aid in early detection of patients at risk and help guide resources to mitigate muscle loss, e.g. physical therapy and protein supplementation. AIMS: To explore serum biomarkers for muscle mass and muscle loss in ICU patients using a metabolomics approach. METHODS: Mechanically ventilated patients with an unplanned ICU admission between June and December 2021 were prospectively studied. The cross-sectional area of the rectus femoris muscle was assessed using ultrasound (RFcsa) and 188 serum metabolites were assessed using the Biocrates™ AbsoluteIDQ p180 kit for targeted metabolomics. Patients were eligible for analysis when a serum sample drawn within 5 days of ICU admission and at least 1 RFcsa were available. In patients with sequential RFcsa measurements, muscle loss was defined as the negative slope of the regression line fitted to the RFcsa measurements per patient in the first 10 days of ICU admission. Correlations between baseline metabolite concentrations and baseline muscle mass, as well as between baseline metabolite concentrations and muscle loss were assessed using Pearson's test for correlations. To correct for multiple testing, the Benjamini-Hochberg procedure was used. RESULTS: Seventeen patients were eligible for analysis. Mean age was 62 (SD ± 9) years and the cohort was predominantly male (76%). Four metabolites correlated with baseline muscle mass: creatinine (R = 0.5, p = 0.041), glycerophospholipid PC_ae_C30_0 (R = 0.5, p = 0.034) and two acylcarnitines: C14_2 (R = 0.5, p = 0.042) and C10_2 (R = 0.5, p = 0.049). For muscle loss, significant associations were found for histidine (R = -0.8, p = 0.002) and three glycerophospholipids; PC_aa_C40_2 (R = 0.7, p = 0.015), PC_ae_C40_1 (R = 0.6, p = 0.032) and PC_aa_C42_1 (R = 0.6, p = 0.037). After correction for multiple testing, no significant associations remained. CONCLUSIONS: This exploratory analysis found certain metabolites to be associated with muscle mass and muscle loss. Future research, specifically addressing these metabolites is necessary to confirm or refute an association with muscle loss and determine their role as potential muscle loss marker.


Assuntos
Estado Terminal , Músculo Quadríceps , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Músculo Quadríceps/diagnóstico por imagem , Creatinina , Cuidados Críticos , Metabolômica
18.
Bone ; 177: 116921, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37769955

RESUMO

BACKGROUND: All musculoskeletal tissues are in a constant state of turnover, with a dynamic equilibrium between tissue protein synthesis and breakdown rates. The synthesis of protein allows musculoskeletal tissues to heal following injury. Yet, impaired tissue healing is observed following certain injuries, such as geriatric hip fractures. It is assumed that the regenerative properties of femoral head bone tissue are compromised following an intracapsular hip fracture and therefore hip replacement surgery is normally performed. However, the actual impact on in vivo bone protein synthesis rates has never been determined. DESIGN: In the present study, 10 patients (age: 79 ± 10 y, BMI: 24 ± 4 kg/m2) with an acute (<24 h) intracapsular hip fracture received a primed continuous intravenous infusion of L-[ring-13C6]-phenylalanine before and throughout their hip replacement surgery. Trabecular and cortical bone tissue from both the femoral head and proximal femur were sampled during surgery to assess protein synthesis rates of affected (femoral head) and unaffected (proximal femur) bone tissue, respectively. In addition, tissue samples of gluteus maximus muscle, synovium, ligamentum teres, and femoral head cartilage were collected. Tissue-specific protein synthesis rates were assessed by measuring L-[ring-13C6]-phenylalanine incorporation in tissue protein. RESULTS: Femoral head trabecular bone protein synthesis rates (0.056 [0.024-0.086] %/h) were lower when compared to proximal femur trabecular bone protein synthesis rates (0.081 [0.056-0.118] %/h; P = 0.043). Cortical bone protein synthesis rates did not differ between the femoral head and proximal femur (0.041 [0.021-0.078] and 0.045 [0.028-0.073] %/h, respectively; P > 0.05). Skeletal muscle, synovium, ligamentum teres, and femoral head cartilage protein synthesis rates averaged 0.080 [0.048-0.089], 0.093 [0.051-0.130], 0.121 [0.110-0.167], and 0.023 [0.015-0.039] %/h, respectively. CONCLUSION: In contrast to the general assumption that the femoral head is avital after an intracapsular displaced hip fracture in the elderly, our data show that bone protein synthesis is still ongoing in femoral head bone tissue during the early stages following an intracapsular hip fracture in older patients. Nonetheless, trabecular bone protein synthesis rates are lower in the femoral head when compared to the proximal femur in older patients following an acute intracapsular hip fracture. Trial register no: NL9036.

19.
Br J Pain ; 16(2): 214-222, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35419200

RESUMO

Background: Complex regional pain syndrome type I (CRPS) is a symptom-based diagnosis of which the reported incidence varies widely. In daily practice, there appears to be a decrease in incidence of CRPS after a distal radius fracture and in general. Questions/purposes: The aim of this study was to assess the trend in the incidence of CRPS after a distal radius fracture and in general in the Netherlands from 2014 to 2018. Methods: The incidence of CRPS after a distal radius fracture was calculated by dividing the number of confirmed cases of CRPS after distal radius fracture by the total number of patients diagnosed with a distal radius fracture. Medical records of these patients were reviewed. Hospital-based data were used to establish a trend in incidence of CRPS in general. A Dutch national database was used to measure the trend in the incidence of CRPS in the Netherlands by calculating annual incidence rates: the number of new CRPS cases, collected from the national database, divided by the Dutch mid-year population. Results: The incidence of CRPS after distal radius fracture over the whole study period was 0.36%. Hospital data showed an absolute decrease in CRPS cases from 520 in 2014 to 223 in 2018. National data confirmed this with a decrease in annual incidence from 23.2 (95% CI: 22.5-23.9) per 100,000 person years in 2014 to 16.1 (95% CI: 15.5-16.7) per 100,000 person years in 2018. Conclusion: A decreasing trend of CRPS is shown in this study. We hypothesize this to be the result of the changing approach towards CRPS and fracture management, with more focus on prevention and the psychological aspects of disproportionate posttraumatic pain. Level of Evidence: level 3 (retrospective cohort study).

20.
Injury ; 53 Suppl 3: S30-S41, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35680433

RESUMO

INTRODUCTION: Sarcopenia is a muscle disease that involves loss of muscle strength and physical function and is associated with adverse health effects. Even though sarcopenia has attracted increasing attention in the literature, many research findings have not yet been translated into clinical practice. In this article, we aim to validate a deep learning neural network for automated segmentation of L3 CT slices and aim to explore the potential for clinical utilization of such a tool for clinical practice. MATERIALS AND METHODS: A deep learning neural network was trained on a multi-centre collection of 3413 abdominal cancer surgery subjects to automatically segment muscle, subcutaneous and visceral adipose tissue at the L3 lumbar vertebral level. 536 Polytrauma subjects were used as an independent test set to show generalizability. The Dice Similarity Coefficient was calculated to validate the geometric similarity. Quantitative agreement was quantified using Bland-Altman's Limits of Agreement interval and Lin's Concordance Correlation Coefficient. To determine the potential clinical usability, randomly selected segmentation images were presented to a panel of experienced clinicians to rate on a Likert scale. RESULTS: Deep learning results gave excellent agreement versus a human expert operator for all of the body composition indices, with Concordance Correlation Coefficient for skeletal muscle index of 0.92, Skeletal muscle radiation attenuation 0.94, Visceral Adipose Tissue index 0.99 and Subcutaneous Adipose Tissue Index 0.99. Triple-blinded visual assessment of segmentation by clinicians correlated only to the Dice coefficient, but had no association to quantitative body composition metrics which were accurate irrespective of clinicians' visual rating. CONCLUSION: A deep learning method for automatic segmentation of truncal muscle, visceral and subcutaneous adipose tissue on individual L3 CT slices has been independently validated against expert human-generated results for an enlarged polytrauma registry dataset. Time efficiency, consistency and high accuracy relative to human experts suggest that quantitative body composition analysis with deep learning should is a promising tool for clinical application in a hospital setting.


Assuntos
Traumatismo Múltiplo , Sarcopenia , Composição Corporal , Humanos , Traumatismo Múltiplo/diagnóstico por imagem , Gordura Subcutânea , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA