Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Prenat Diagn ; 34(12): 1133-8, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24961405

RESUMO

OBJECTIVES: The objectives of this study were to report pregnancy outcomes after prenatal diagnosis of Turner syndrome (TS) and to compare and assess termination of pregnancy rates during two periods. The intervals selected were before and after 1997 when multidisciplinary centers for prenatal diagnosis (MCPDs) were established in France. METHODS: A database of 975 cases of TS diagnosed between 1980 and 2012 was created from 21 French cytogenetics laboratories. For each case, the karyotype indication, maternal age, year of prenatal testing, sampling procedure, karyotype, associated ultrasound findings, and outcomes were recorded. RESULTS: Karyotypes were mainly performed because of abnormal sonographic findings (84%). Before 1997, there were no changes in the rate of termination (90%) of affected fetuses. After 1997, the rate fell to 80%. This decrease was mainly observed in cases of mosaicism, incidental diagnosis, and in later gestations. US abnormalities were more likely to be associated with a full 45,X karyotype. CONCLUSION: There was an evolution in the way genetic counseling was performed following prenatal diagnosis of Turner syndrome that coincided with the opening of MCPDs in France. This resulted in a decrease in the rate of termination of affected fetuses.


Assuntos
Aborto Induzido/estatística & dados numéricos , Síndrome de Turner/diagnóstico por imagem , Adulto , Feminino , França/epidemiologia , Aconselhamento Genético/organização & administração , Humanos , Cariotipagem/estatística & dados numéricos , Medição da Translucência Nucal , Gravidez , Resultado da Gravidez , Estudos Retrospectivos
3.
Environ Technol ; 39(17): 2251-2265, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28792277

RESUMO

Scrap material recovery and recycling companies are producing wastewater in which common pollutants (such as COD, nutrients and suspended solids), toxic metals, polyaromatic hydrocarbons (PAH) and polychlorinated biphenyls (PCB) frequently can exceed the discharge limits. Lab-scale optimisation of different possible physical-chemical treatment techniques was performed on the wastewater originating from three different companies in view of further testing at pilot-scale testing and implementation at full-scale. The lab-scale tests demonstrate that sedimentation or hydrocyclone treatment as stand-alone technique cannot be used for proper treatment of this type of wastewater. Dual bed filtration or coagulation/flocculation proved to be more promising with removal efficiencies of about 71-95% (dual bed filtration) and 61-97% (coagulation/flocculation) for the above-mentioned pollutants (metals, PAH and PCB).


Assuntos
Reciclagem , Eliminação de Resíduos Líquidos , Poluentes Químicos da Água , Filtração , Floculação , Águas Residuárias
4.
Clin Case Rep ; 2(3): 98-102, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25356259

RESUMO

KEY CLINICAL MESSAGE: Translocations between X and acrocentric chromosomes are rare. We report on the inheritance of a familial t(X;15)(p22.3;p10) translocation in a fetus referred for short long bones. Cytogenetic analysis revealed an unbalanced translocation combined with a three-gene nullosomy. After genetic counseling, a prognosis was established and a healthy boy was delivered.

5.
Waste Manag ; 34(12): 2674-86, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25241019

RESUMO

Scrap material recovery and recycling companies are confronted with waste water that has a highly fluctuating flow rate and composition. Common pollutants, such as COD, nutrients and suspended solids, potentially toxic metals, polyaromatic hydrocarbons and poly chlorinated biphenyls can exceed the discharge limits. An analysis of the leaching behaviour of different scrap materials and scrap yard sweepings was performed at full-scale, pilot-scale and lab-scale in order to find possible preventive solutions for this waste water problem. The results of these leaching tests (with concentrations that frequently exceeded the Flemish discharge limits) showed the importance of regular sweeping campaigns at the company, leak proof or covered storage of specific scrap materials and oil/water separation on particular leachates. The particulate versus dissolved fraction was also studied for the pollutants. For example, up to 98% of the polyaromatic hydrocarbons, poly chlorinated biphenyls and some metals were in the particulate form. This confirms the (potential) applicability of sedimentation and filtration techniques for the treatment of the majority of the leachates, and as such the rainwater run-off as a whole.


Assuntos
Resíduos Industriais/análise , Resíduos Sólidos/análise , Eliminação de Resíduos Líquidos , Poluentes Químicos da Água/análise , Filtração , Reciclagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA