Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Refract Surg ; 31(3): 153-7, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25751830

RESUMO

PURPOSE: To evaluate and compare the mechanical properties of anterior capsule opening performed with femtosecond laser capsulotomy at different energy settings in ex vivo porcine anterior lens capsule specimens. METHODS: Twenty-five fresh porcine eyes per group were included in the study. Femtosecond laser capsulotomy was performed with three different pulse energy levels: 2 µJ (low energy group), 5 µJ (intermediate energy group), and 10 µJ (high energy group). The capsule openings were stretched with universal testing equipment until they ruptured. The morphologic profile of the cut capsule edges was evaluated using scanning electron microscopy. RESULTS: The high energy group had significantly lower rupture force (108 ± 14 mN) compared to the intermediate energy group (118 ± 10 mN) (P < .05) and low energy group (119 ± 11 mN) (P < .05), but the difference between the intermediate energy and low energy groups was not significant (P = .9479). The high energy group had significantly lower circumference stretching ratio (144% ± 3%) compared to the intermediate energy group (148% ± 3%) (P < .05) and low energy group (148% ± 3%) (P < .05), but the difference between the intermediate energy group and low energy group was not significant (P = .9985). Scanning electron microscopy images showed that the edge was only serrated with low and intermediate energy, but additional signs of collagen melting and denaturation were observed at high energy. CONCLUSIONS: Anterior capsule openings created at a high energy level were slightly weaker and less extensible than those created at low or intermediate levels, possibly due to the increased thermal effect of photo-disruption.


Assuntos
Cápsula Anterior do Cristalino/fisiologia , Elasticidade/fisiologia , Capsulotomia Posterior/métodos , Animais , Cápsula Anterior do Cristalino/cirurgia , Cápsula Anterior do Cristalino/ultraestrutura , Fenômenos Biomecânicos , Microscopia Eletrônica de Varredura , Suínos
2.
J Refract Surg ; 30(10): 660-4, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25291748

RESUMO

PURPOSE: To evaluate and compare the mechanical properties of anterior capsule openings performed with the continuous curvilinear capsulorhexis (CCC) technique and femtosecond laser capsulotomy (FLC) in ex vivo porcine lens capsule specimens. METHODS: Fresh porcine eyes were included in the study (CCC group, n = 50; FLC group, n = 30). The capsule openings were stretched with universal testing equipment until they ruptured. The rupture force and circumference stretching ratio were evaluated. The morphologic profile of the cut capsule edges was evaluated using scanning electron microscopy (SEM). RESULTS: The average rupture force was higher in the CCC group (median: 155 mN; interquartile range [IQR]: 129 to 201 mN; range: 71 to 294 mN) than in the FLC group (median: 119 mN; IQR: 108 to 128 mN; range: 91 to 142 mN) (P < .01, Mann-Whitney U test). The average circumference stretching ratio in the CCC group was greater (median: 150%; IQR: 146% to 156%; range: 136% to 161%) than in the FLC group (median: 148%; IQR: 145% to 150%; range: 141% to 154%) (P = .0468, Mann-Whitney U test). When less than 71 mN, no capsular tear occurred in either group. When less than 91 mN, no capsular tear occurred in the FLC group, whereas at 91 mN, the probability of capsular tears was 9% for the CCC group. SEM examination found that the CCC group had smooth edges, whereas those of the FLC group were gently serrated. CONCLUSIONS: According to the current results in a porcine eye model, FLC had less average resistance to capsule tear than CCC, but the weakest openings were seen in the CCC group.


Assuntos
Cápsula Anterior do Cristalino/fisiologia , Fenômenos Biomecânicos/fisiologia , Capsulorrexe , Terapia a Laser , Animais , Cápsula Anterior do Cristalino/cirurgia , Cápsula Anterior do Cristalino/ultraestrutura , Microscopia Eletrônica de Varredura , Ruptura da Cápsula Posterior do Olho/fisiopatologia , Estresse Mecânico , Suínos
3.
J Cataract Refract Surg ; 46(2): 293-297, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-32126044

RESUMO

PURPOSE: To evaluate and compare the mechanical resistance to tearing of the anterior lens capsule opening after staining with different concentrations of trypan blue in ex vivo porcine eyes. SETTING: Semmelweis University, and Budapest University of Technology and Economics, Budapest, Hungary. DESIGN: Experimental study. METHODS: The study comprised 75 porcine eyes. The capsule was unstained in the Control Group (n = 25 eyes), 0.06% trypan blue was used to stain the capsule in Stained 1 Group (n = 25 eyes), and 0.1% trypan blue was used to stain the capsule in Stained 2 Group (n = 25 eyes). After capsulorhexis, the capsule openings were stretched with custom-designed testing equipment until they ruptured. The rupture force (RF), circumference stretching ratio (CSR), and secant modulus at 10 mN (SM10mN) and 50 mN (SM50mN) were evaluated. RESULTS: In total, 75 eyes were enrolled. There were no statistically significant differences in the RF (P = .8924) or CSR (P = .3876) among the groups. There were no statistically significant differences in the SM10mN (P = .8215) or SM50mN (P = .4184) among the groups. CONCLUSIONS: In this porcine eye model, the trypan blue concentrations that are routinely used in cataract surgery had no effect on capsular rim stability.


Assuntos
Cápsula Anterior do Cristalino/lesões , Fenômenos Biomecânicos/fisiologia , Corantes/administração & dosagem , Ruptura/fisiopatologia , Azul Tripano/administração & dosagem , Animais , Cápsula Anterior do Cristalino/efeitos dos fármacos , Cápsula Anterior do Cristalino/fisiopatologia , Capsulorrexe , Elasticidade/fisiologia , Coloração e Rotulagem/métodos , Suínos
4.
J Biomech ; 47(13): 3264-71, 2014 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-25242131

RESUMO

The mechanical behaviour of zonular fibres greatly affects the accommodation process in mammalian eyes. This paper introduces a detailed measurement procedure for the purpose of obtaining the force-displacement diagram necessary to evaluate the mechanical properties of porcine zonular fibres in situ. It is a complex technique, keeping the integrity of the zonular bundles between the crystalline lens and the ciliary muscle cells. We present a brief description of the measurement procedure both in theory and in practice, along with the force-displacement diagrams acquired from a porcine sample group. The strengths of this newly developed method are the unequivocal force transmission between the sample and the transducer, and the intact connection between the ciliary body and the crystalline lens via zonular fibres. With the aid of these measurements, we define an estimated material model for the zonular apparatus both analytically and using the finite element method. The two different evaluation methods show close agreement in the calculated Young's modulus for the zonular fibres. The range of the calculated elastic modulus is 200-250 kPa. This new measuring method is adaptable to human specimens. Despite its complexity, the entire procedure and the evaluation part are reproducible. The constitutive model aims to shed light on the mechanics of the accommodation process.


Assuntos
Corpo Ciliar , Módulo de Elasticidade , Cristalino , Teste de Materiais/métodos , Acomodação Ocular , Animais , Fenômenos Biomecânicos , Corpo Ciliar/citologia , Corpo Ciliar/fisiologia , Análise de Elementos Finitos , Cristalino/citologia , Cristalino/fisiologia , Células Musculares/citologia , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA