Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Biomech Eng ; 146(1)2024 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-37773642

RESUMO

High-grade gliomas (HGG) are the most common primary brain malignancy and continue to be associated with a dismal prognosis (median survival rate of 15-18 months) with standard of care therapy. Magnetic hyperthermia therapy (MHT) is an emerging intervention that leverages the ferromagnetic properties of magnetic iron-oxide nanoparticles (MIONPs) to target cancer cells that are otherwise left behind after resection. We report a novel port device to facilitate localization, delivery, and temperature measurement of MIONPs within a target lesion for MHT therapy. We conducted an in-depth literature and intellectual property review to define specifications of the conceived port device. After setting the design parameters, a thorough collaboration with neurological surgeons guided the iterative modeling process. A prototype was developed using Fusion 360 (Autodesk, San Rafael, CA) and printed on a Form 3 printer (Formlabs, Medford, MA) in Durable resin. The prototype was then tested in a phantom skull printed on a Pro-Jet 660Pro 3D printer (3D Systems, Rock Hill, SC) and a brain model based on mechanical and electrochemical properties of native brain tissue. This phantom underwent MHT heating tests using an alternating magnetic field (AMF) sequence based on current MHT workflow. Successful localization, delivery, and temperature measurement were demonstrated. The purpose of this study was twofold: first, to create and validate the procedural framework for a novel device, providing the groundwork for an upcoming comprehensive animal trial and second, to elucidate a cooperative approach between engineers and clinicians that propels advancements in medical innovation.


Assuntos
Neoplasias Encefálicas , Glioma , Hipertermia Induzida , Animais , Glioma/terapia , Neoplasias Encefálicas/terapia , Encéfalo , Fenômenos Magnéticos
2.
Magn Reson Med ; 78(4): 1623-1634, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-27859558

RESUMO

PURPOSE: Increased signal-to-noise ratio and blood oxygenation level-dependent sensitivity at 7 Tesla (T) have the potential to enable high-resolution imaging of the human cervical spinal cord and brainstem. We propose a new two-panel radiofrequency coil design for these regions to fully exploit the advantages of ultra-high field. METHODS: A two-panel array, containing four transmit/receive and 18 receive-only elements fully encircling the head and neck, was constructed following simulations demonstrating the B1+ and specific absorption rate (SAR) benefits of two-panel over one-panel arrays. This array was compared with a previously reported posterior-only array and tested for safety using a phantom. Its anatomical, functional, and diffusion MRI performance was demonstrated in vivo. RESULTS: The two-panel array produced more uniform B1+ across the brainstem and cervical spinal cord without compromising SAR, and achieved 70% greater receive sensitivity than the posterior-only array. The two-panel design enabled acceleration of R = 2 × 2 in two dimensions or R = 3 in a single dimension. High quality in vivo anatomical, functional, and diffusion images of the human cervical spinal cord and brainstem were acquired. CONCLUSION: We have designed and constructed a wrap-around coil array with excellent performance for cervical spinal cord and brainstem MRI at 7T, which enables simultaneous human cervical spinal cord and brainstem functional MRI. Magn Reson Med 78:1623-1634, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Tronco Encefálico/diagnóstico por imagem , Medula Cervical/diagnóstico por imagem , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Adulto , Desenho de Equipamento , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Imagens de Fantasmas , Razão Sinal-Ruído
3.
J Vis Exp ; (196)2023 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-37335101

RESUMO

Heart failure remains the leading cause of death worldwide, creating a pressing need for better preclinical models of the human heart. Tissue engineering is crucial for basic science cardiac research; in vitro human cell culture eliminates the interspecies differences of animal models, while a more tissue-like 3D environment (e.g., with extracellular matrix and heterocellular coupling) simulates in vivo conditions to a greater extent than traditional two-dimensional culture on plastic Petri dishes. However, each model system requires specialized equipment, for example, custom-designed bioreactors and functional assessment devices. Additionally, these protocols are often complicated, labor-intensive, and plagued by the failure of the small, delicate tissues. This paper describes a process for generating a robust human engineered cardiac tissue (hECT) model system using induced pluripotent stem-cell-derived cardiomyocytes for the longitudinal measurement of tissue function. Six hECTs with linear strip geometry are cultured in parallel, with each hECT suspended from a pair of force-sensing polydimethylsiloxane (PDMS) posts attached to PDMS racks. Each post is capped with a black PDMS stable post tracker (SPoT), a new feature that improves the ease of use, throughput, tissue retention, and data quality. The shape allows for the reliable optical tracking of post deflections, yielding improved twitch force tracings with absolute active and passive tension. The cap geometry eliminates tissue failure due to hECTs slipping off the posts, and as they involve a second step after PDMS rack fabrication, the SPoTs can be added to existing PDMS post-based designs without major changes to the bioreactor fabrication process. The system is used to demonstrate the importance of measuring hECT function at physiological temperatures and shows stable tissue function during data acquisition. In summary, we describe a state-of-the-art model system that reproduces key physiological conditions to advance the biofidelity, efficiency, and rigor of engineered cardiac tissues for in vitro applications.


Assuntos
Células-Tronco Pluripotentes Induzidas , Engenharia Tecidual , Animais , Humanos , Engenharia Tecidual/métodos , Contração Miocárdica , Miócitos Cardíacos , Reatores Biológicos
4.
Cancers (Basel) ; 15(2)2023 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-36672278

RESUMO

We present in vivo validation of an automated magnetic hyperthermia therapy (MHT) device that uses real-time temperature input measured at the target to control tissue heating. MHT is a thermal therapy that uses heat generated by magnetic materials exposed to an alternating magnetic field. For temperature monitoring, we integrated a commercial fiber optic temperature probe containing four gallium arsenide (GaAs) temperature sensors. The controller device used temperature from the sensors as input to manage power to the magnetic field applicator. We developed a robust, multi-objective, proportional-integral-derivative (PID) algorithm to control the target thermal dose by modulating power delivered to the magnetic field applicator. The magnetic field applicator was a 20 cm diameter Maxwell-type induction coil powered by a 120 kW induction heating power supply operating at 160 kHz. Finite element (FE) simulations were performed to determine values of the PID gain factors prior to verification and validation trials. Ex vivo verification and validation were conducted in gel phantoms and sectioned bovine liver, respectively. In vivo validation of the controller was achieved in a canine research subject following infusion of magnetic nanoparticles (MNPs) into the brain. In all cases, performance matched controller design criteria, while also achieving a thermal dose measured as cumulative equivalent minutes at 43 °C (CEM43) 60 ± 5 min within 30 min.

5.
Appl Radiat Isot ; 132: 189-194, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29253756

RESUMO

Recently published studies have suggested an annual fluctuation of the decay rate of several radionuclides, in particular 32Si and 226Ra. Variation of solar neutrino flux caused by variation of Earth-Sun distance has been proposed as the mechanism of this fluctuation. In this study we prospectively look at two radionuclides which have not previously been studied for annual variation, 123I and 99mTc. Half-lives of samples of these radionuclides were measured approximately weekly and semiweekly respectively over a period of 2 years. Spectral analysis using the Lomb-Scargle method demonstrated no significant periodicity, and in particular, no evidence for a period of 1 year.

6.
Addit Manuf ; 23: 374-380, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31106119

RESUMO

Multi-material 3D printing with several mechanically distinct materials at once has expanded the potential applications for additive manufacturing technology. Fewer material options exist, however, for additive systems that employ vat photopolymerization (such as stereolithography, SLA, and digital light projection, DLP, 3D printers), which are more commonly used for advanced engineering prototypes and manufacturing. Those material selections that do exist are limited in their capacity for fusion due to disparate chemical and physical properties, limiting the potential mechanical range for multi-material printed composites. Here, we present an ethylene glycol phenyl ether acrylate (EGPEA)-based formulation for a polymer resin yielding a range of elastic moduli between 0.6 MPa and 33 MPa simply by altering the ratio of monomer and crosslinker feedstocks in the formulation. This simple chemistry is also well suited to form seamless adhesions between mechanically dissimilar formulations, making it a promising candidate for multi-material DLP 3D printing. Preliminary tests with these polymer formulations indicate that variability due to molecular differences between hard and soft formulations is near net shape and less than 3% of the prescribed dimensions, comparable to existing commercial DLP and SLA resins, with unique advantages of a wide range of elastomer stiffness and seamless fusion for 3D printing of structurally detailed and mechanically heterogeneous composites.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA