Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Anal Bioanal Chem ; 394(3): 759-82, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19238366

RESUMO

Recently, cloud point extraction (CPE) has been an attractive subject as an alternative to liquid-liquid extraction. The technique is based on the property of most non-ionic surfactants in aqueous solutions to form micelles and become turbid when heated to the cloud point temperature. This review covers a selection of the literature published on applications of CPE in determination of metal ions over the period between 2004 and 2008.


Assuntos
Métodos Analíticos de Preparação de Amostras/métodos , Metais/análise , Micelas , Soluções , Tensoativos/química , Temperatura , Água/química
2.
J Pharm Biomed Anal ; 48(3): 519-32, 2008 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-18701232

RESUMO

Furosemide (FUR), a drug that promotes urine excretion, is used in the pharmacotherapy of various diseases and is considered as a doping agent in sports. FUR is a powerful diuretic (water pill). This medicine is used to treat excessive fluid accumulation and swelling (edema) of the body caused by heart failure, cirrhosis, chronic kidney failure, and nephrotic syndrome. Owing to its extensive use as a powerful diuretic, FUR has long attracted the attention of many analysts. A variety of analytical methods have been proposed for the determination of FUR in biological fluids and pharmaceutical samples. The revision includes the most relevant analytical methodologies used in its determination from the nineties decade at present.


Assuntos
Técnicas de Química Analítica/métodos , Diuréticos/análise , Diuréticos/química , Furosemida/análise , Eletroquímica/métodos , Furosemida/química , Humanos , Luminescência , Medições Luminescentes/métodos , Estrutura Molecular , Espectrometria de Fluorescência/métodos , Titulometria/métodos
3.
J Pharm Biomed Anal ; 44(4): 831-44, 2007 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-17532167

RESUMO

Omeprazole, a gastric acid pump inhibitor, dose-dependently controls gastric acid secretion; the drug has greater antisecretory activity than histamine H(2)-receptor antagonists. Omeprazole has been determined in formulations and biological fluids by a variety of methods such as spectrophotometry, high-performance liquid chromatography with ultraviolet detection and liquid chromatography coupled with tandem mass spectrometry. The overview includes the most relevant analytical methodologies used in its determination since the origin still today.


Assuntos
Omeprazol/análise , Animais , Cromatografia Líquida de Alta Pressão , Cromatografia com Fluido Supercrítico , Cromatografia em Camada Fina , Eletroquímica , Eletroforese Capilar , Humanos , Espectrometria de Massas , Espectrofotometria , Espectrofotometria Ultravioleta
4.
J Pharm Biomed Anal ; 42(3): 291-321, 2006 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-16716555

RESUMO

Paracetamol is a common analgesic and antipyretic drug that is used for the relief of fever, headaches and other minor aches and pains. Their determination in pharmaceuticals is of paramount importance, since an overdose of paracetamol can cause fulminating hepatic necrosis and other toxic effects. Many analytical methodologies have been proposed for the determination of paracetamol. The aim of the present study is to evaluate the utility of different techniques for quantification of paracetamol content in pharmaceutical formulations and biological samples.


Assuntos
Acetaminofen/análise , Animais , Química Farmacêutica , Cromatografia Líquida de Alta Pressão , Eletroforese Capilar , Análise de Injeção de Fluxo , Humanos , Medições Luminescentes , Espectrometria de Fluorescência , Espectroscopia de Infravermelho com Transformada de Fourier , Espectroscopia de Luz Próxima ao Infravermelho
5.
Ann Chim ; 96(11-12): 707-14, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17217175

RESUMO

A method of determining trace levels of platinum and rhodium in different samples was investigated. The method involves separation and preconcentration of the platinum and rhodium from the matrix by flow injection (FI) on-line coupled with electrothermal atomic absorption spectrometry (ETAAS) with Zeeman effect background correction. Platinum and rhodium were adsorbed on a microcolumn packed with 1,5-bis(di-2-pyridyl)methylene thiocarbohydrazide immobilized on silica gel (DPTH-gel). The sorbed metals were directly eluted with nitric acid into the graphite furnace and determined by AAS.


Assuntos
Platina/análise , Ródio/análise , Poluentes do Solo/análise , Poluentes Químicos da Água/análise , Animais , Bovinos , Monitoramento Ambiental , Peixes , Análise de Injeção de Fluxo , Contaminação de Alimentos/análise , Resinas de Troca Iônica , Lens (Planta)/química , Fígado/química , Sistemas On-Line , Oryza/química , Pinus/química , Espectrofotometria Atômica , Vinho/análise
6.
Talanta ; 47(2): 463-70, 1998 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18967347

RESUMO

A method for the simultaneous spectrophotometric determination of the divalent ions of iron, cobalt, nickel and copper based on the formation of their complexes with 1,5-bis(di-2-pyridylmethylene) thiocarbonohydrazide (DPTH) is proposed. The resolution of quaternary mixtures of these metallic ions was accomplished by several chemometric approaches. A comparative study of the results obtained for simultaneous determinations in mixture by using principal component regression (PCR) and partial least-squares regression (PLS-1 and PLS-2) for absorbance, first-derivative and second-derivative data is presented. In general, the best recovery values are obtained by the PLS-2 method for absorbance data. This procedure allows the simultaneous determination of the cited ions in alloys and biological materials Good reliability of the determination was proved.

7.
Anal Chim Acta ; 635(1): 22-44, 2009 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-19200476

RESUMO

Several techniques have been proposed for treatment of spectrophotometric data, with the objective of extracting a largest amount of analytical information from spectra composed of unresolved bands. Undoubtedly, a major success was achieved by derivative treatment of the absorbance curves-plotting of the first or a higher order mathematical derivative of absorbance against wavelength (d A/d lambda). Derivative spectrophotometry has been applied to many chemical systems, such as pharmaceuticals, foods, cosmetics, and environmental samples. The instrumental development and analytical applications of derivative UV-vis regions absorption spectrophotometry produced in the last 5 years (since 2004) are reviewed.

8.
Talanta ; 71(2): 918-22, 2007 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-19071395

RESUMO

In this work, a simple preconcentration system, achieved by replacing the sample tip of the autosampler arm by a micro-column packed with Amberlite IRA-910 or silica gel chelating resin functionalised with 1,5-bis(di-2-pyridyl)methylene tbiocarbohydrazide (DPTH-gel), is developed for the determination of Sb(V) and total antimony, respectively. Different factors including pH of sample solution, ionic strength, concentration and volume of eluent, sample flow rate, sample loading time and matrix effects for preconcentration were investigated. The method has been applied to the determination of antimony species in different samples.

9.
Talanta ; 68(5): 1407-20, 2006 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-18970480

RESUMO

Rhodium is present at about 0.001ppm in the earths crust. Rhodium metal is known for its stability in corrosive environments, physical beauty and unique physical and chemical properties. Recent interest in the medical and industrial significance of platinum and to a lesser extent palladium and rhodium has been accompanied by an increasing interest in their determination at low levels. Platinum group elements (PGEs: Pt, Pd, Rh, Ru, Ir and Os) play a decisive role in the performance of catalytic converters, world-wide applied in vehicles and in some household utensils, to reduce the emission of gaseous pollutants, such as carbon monoxide, nitrogen oxides and hydrocarbons. Since then, approximately 73% of the world production of rhodium is consumed in the production of autocatalyst. However, the hot exhaust gases flowing through the converter cause abrasion of these units, leading to the emission of these elements to the environment. The concentration level of rhodium (also platinum and palladium) is still very low in the nature; accordingly, their determination in environmental samples specially appears to be a challenging task for analytical chemists. In recent years, the development of analytical methods for the determination of rhodium has increased. The aim of the present review is to evaluate the utility of atomic absorption spectrometry, applied for the quantification of rhodium in different materials, such as environmental, biological, metallurgical and geological samples.

10.
Anal Bioanal Chem ; 382(4): 978-91, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15895211

RESUMO

This review summarizes and discusses effluent analysis, focusing on the methods and techniques that have been most frequently described in the literature since 1975. The methods are classified into four main categories: (1) physical and chemical properties; (2) inorganic metals analysis; (3) inorganic non-metallic analysis; (4) organic analysis.

11.
Anal Bioanal Chem ; 382(2): 513-8, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15940456

RESUMO

Selective sorption of Sb(III) on a microcolumn packed with 1,5-bis(di-2-pyridyl)methylene thiocarbohydrazide immobilized on silica gel (DPTH-gel) has been used for determination of Sb(III). A flow-injection system comprising a microcolumn connected to the tip of the autosampler was used for preconcentration. The sorbed antimony was eluted with nitric acid directly into the graphite furnace and determined by AAS. The detection limit for antimony under the optimum conditions was 0.3 ng mL(-1). This procedure was used for determination of antimony in natural water, soil, vegetation, and a certified sample of a city waste incineration ash (BCR 176).

12.
Anal Bioanal Chem ; 375(8): 1229-33, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12733043

RESUMO

A method to determine trace amounts of platinum in different samples based on electrothermal atomic absorption spectrometry is described. The preconcentration step is performed on a chelating resin microcolumn [1,5-bis(2-pyridyl)-3-sulfophenyl methylene thiocarbonohydrazide (PSTH) immobilized on an anion-exchange resin (Dowex 1x8-200)] placed in the autosampler arm. The combination of a peristaltic pump for sample loading and the atomic absorption spectrometer pumps for elution through a selection valve simplifies the hardware. The peristaltic pump and the selection valve are easily controlled electronically with two switches placed in the autosampler, which are activated when the autosampler arm is down. Thus, the process is fully automated without any modification of the software of the atomic absorption spectrometer. Under the optimum conditions with a 60-s preconcentration time, a sample flow rate of 2.4 mL min(-1), and an injection volume of eluent of 40 microL, a linear calibration graph was obtained in the range 0-100 ng mL(-1). The enrichment factor was 14. The detection limit under these conditions is 1 ng mL(-1), and the relative standard deviation (RSD) is 1.6% for 10 ng mL(-1) of Pt. The method has been applied to the determination of platinum in catalyst, vegetation, soil, and natural water samples. The results showed good agreement with the certified value and the recoveries of Pt added to samples were 98-105%.


Assuntos
Plantas/química , Platina/análise , Solo/análise , Análise Espectral/métodos , Água/química , Íons , Análise Espectral/instrumentação
13.
Analyst ; 117(11): 1749-51, 1992 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-1481997

RESUMO

An inductively coupled plasma atomic emission spectrometric method for the determination of trace amounts of cadmium after extraction of the metal into isobutyl methyl ketone containing 1,5-bis(di-2-pyridylmethylene) thiocarbonohydrazide is described. The optimum extraction conditions were evaluated from a critical study of the effects of pH, concentration of extractant, shaking time and ionic strength. The detection limit for cadmium is 0.1 ng ml-1 and the calibration is linear from 0.2 to 140 ng ml-1. The relative standard deviation for ten replicate measurements is 2.9% for 2 ng ml-1 of cadmium. Results from the analysis of some certified biological reference materials are given.


Assuntos
Cádmio/análise , Análise Espectral/métodos , Animais , Hidrazinas , Concentração de Íons de Hidrogênio , Indicadores e Reagentes , Metil n-Butil Cetona , Microquímica , Piridinas , Análise Espectral/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA