Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Radiology ; 287(1): 185-193, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29498593

RESUMO

Purpose To compare the biopsy rate and diagnostic accuracy before and after applying the American College of Radiology (ACR) Thyroid Imaging Reporting and Data System (TI-RADS) criteria for thyroid nodule evaluation. Materials and Methods In this retrospective study, eight radiologists with 3-32 years experience in thyroid ultrasonography (US) reviewed US features of 100 thyroid nodules that were cytologically proven, pathologically proven, or both in December 2016. The radiologists evaluated nodule features in five US categories and provided biopsy recommendations based on their own practice patterns without knowledge of ACR TI-RADS criteria. Another three expert radiologists served as the reference standard readers for the imaging findings. ACR TI-RADS criteria were retrospectively applied to the features assigned by the eight radiologists to produce biopsy recommendations. Comparison was made for biopsy rate, sensitivity, specificity, and accuracy. Results Fifteen of the 100 nodules (15%) were malignant. The mean number of nodules recommended for biopsy by the eight radiologists was 80 ± 16 (standard deviation) (range, 38-95 nodules) based on their own practice patterns and 57 ± 11 (range, 37-73 nodules) with retrospective application of ACR TI-RADS criteria. Without ACR TI-RADS criteria, readers had an overall sensitivity, specificity, and accuracy of 95% (95% confidence interval [CI]: 83%, 99%), 20% (95% CI: 16%, 25%), and 28% (95% CI: 21%, 37%), respectively. After applying ACR TI-RADS criteria, overall sensitivity, specificity, and accuracy were 92% (95% CI: 68%, 98%), 44% (95% CI: 33%, 56%), and 52% (95% CI: 40%, 63%), respectively. Although fewer malignancies were recommended for biopsy with ACR TI-RADS criteria, the majority met the criteria for follow-up US, with only three of 120 (2.5%) malignancy encounters requiring no follow-up or biopsy. Expert consensus recommended biopsy in 55 of 100 nodules with ACR TI-RADS criteria. Their sensitivity, specificity, and accuracy were 87% (95% CI: 48%, 98%), 51% (95% CI: 40%, 62%), and 56% (95% CI: 46%, 66%), respectively. Conclusion ACR TI-RADS criteria offer a meaningful reduction in the number of thyroid nodules recommended for biopsy and significantly improve the accuracy of recommendations for nodule management. © RSNA, 2018 Online supplemental material is available for this article.


Assuntos
Sistemas de Informação em Radiologia/estatística & dados numéricos , Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/patologia , Ultrassonografia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia/estatística & dados numéricos , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Sociedades Médicas , Glândula Tireoide/diagnóstico por imagem , Glândula Tireoide/patologia , Estados Unidos , Adulto Jovem
2.
AJR Am J Roentgenol ; 211(1): 162-167, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29702015

RESUMO

OBJECTIVE: The purpose of this study was to assess interobserver variability in assigning features in the American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS) lexicon and in making recommendations for thyroid nodule biopsy. MATERIALS AND METHODS: The study cohort comprised 100 nodules in 92 patients who underwent fine-needle aspiration with definitive cytologic results (Bethesda category II or VI) or diagnostic lobectomy between April 2009 and May 2010. Eight board-certified radiologists evaluated the nodules according to the five feature categories that constitute ACR TI-RADS and gave a biopsy recommendation based on their own practice. Variability in feature assignment and biopsy recommendation was assessed with the Fleiss kappa statistic. RESULTS: Agreement in interpretation was fair to moderate for all features except shape (κ = 0.61) and macrocalcifications (κ = 0.73), which had substantial agreement. The features with the poorest agreement were margin and other types of echogenic foci, which had kappa values ranging from 0.25 to 0.39, indicating fair agreement. Interobserver agreement regarding biopsy recommendation was fair (κ = 0.22) based on radiologists' current practice. Applying ACR TI-RADS resulted in moderate agreement (κ = 0.51). CONCLUSION: Variability in interpreting thyroid nodule sonographic features was highest for margin and all types of echogenic foci, except for macrocalcifications. Because radiologists' interpretations of these features change the level of suspicion of thyroid malignancy, the results of this study suggest a need for further education. Despite the variability in assigning features, adoption of ACR TI-RADS improves agreement for recommending biopsy.


Assuntos
Neoplasias da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/diagnóstico por imagem , Ultrassonografia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha Fina , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Sociedades Médicas , Neoplasias da Glândula Tireoide/patologia , Nódulo da Glândula Tireoide/patologia , Estados Unidos
3.
Radiology ; 256(2): 397-405, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20530754

RESUMO

PURPOSE: To compare an algorithm of gradually ramped-up power to a full-power-level technique to determine which technical parameters maximized tissue coagulation by using a saline-perfused electrode. MATERIALS AND METHODS: Institutional review board approval was not necessary and animal committee approval was unnecessary because an ex vivo bovine liver model was used and the animals were not specifically killed for this study. This four-part experiment utilized multiple ablations of ex vivo bovine liver with a standard radiofrequency (RF) generator and an internally cooled needle. First, 10 RF ablations were performed at 20-60 W for 12 minutes. Second, ablation volumes obtained from an algorithm of eight ablations performed at 50 W were compared with those obtained from an algorithm of eight ablations that were gradually ramped-up to 50 W, until full impedance. Third, volumes obtained from 10 ablations performed at impedance control power levels were compared with those obtained from 10 ablations performed with a gradual ramp-up of power that started at 50 W, terminating at full impedance. Last, the third part was repeated, but with 11 ablations continuing past full impedance for 12 minutes each. RESULTS: In the first part, maximum measurements of tissue coagulation seemed to plateau from 40 to 60 W. The second part produced significantly larger measurements of tissue coagulation than did the use of a constant power level of 50 W. The third and final parts produced larger measurements of tissue coagulation than did utilizing full power for 12 minutes. Larger measurements and volumes were obtained from repeat ablations after the generator reached impedance level than were obtained from ablations stopped at maximum impedance. CONCLUSION: A gradual ramp-up of power and repeating ablations after power impedance level is reached are the two methods that increased tissue ablation in this ex vivo experiment.


Assuntos
Ablação por Cateter/instrumentação , Eletrodos , Hepatectomia/instrumentação , Hepatectomia/métodos , Fígado/fisiologia , Fígado/cirurgia , Cirurgia Assistida por Computador/métodos , Animais , Temperatura Corporal , Ablação por Cateter/métodos , Bovinos , Temperatura Baixa , Técnicas In Vitro
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA