Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
J Synchrotron Radiat ; 29(Pt 3): 896-907, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-35511023

RESUMO

The increase in successful adaptations of serial crystallography at synchrotron radiation sources continues. To date, the number of serial synchrotron crystallography (SSX) experiments has grown exponentially, with over 40 experiments reported so far. In this work, we report the first SSX experiments with viscous jets conducted at ALBA beamline BL13-XALOC. Small crystals (15-30 µm) of five soluble proteins (lysozyme, proteinase K, phycocyanin, insulin and α-spectrin-SH3 domain) were suspended in lipidic cubic phase (LCP) and delivered to the X-ray beam with a high-viscosity injector developed at Arizona State University. Complete data sets were collected from all proteins and their high-resolution structures determined. The high quality of the diffraction data collected from all five samples, and the lack of specific radiation damage in the structures obtained in this study, confirm that the current capabilities at the beamline enables atomic resolution determination of protein structures from microcrystals as small as 15 µm using viscous jets at room temperature. Thus, BL13-XALOC can provide a feasible alternative to X-ray free-electron lasers when determining snapshots of macromolecular structures.


Assuntos
Lasers , Síncrotrons , Cristalografia por Raios X , Humanos , Substâncias Macromoleculares , Proteínas , Viscosidade
3.
Nature ; 505(7482): 244-7, 2014 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-24270807

RESUMO

The determination of protein crystal structures is hampered by the need for macroscopic crystals. X-ray free-electron lasers (FELs) provide extremely intense pulses of femtosecond duration, which allow data collection from nanometre- to micrometre-sized crystals in a 'diffraction-before-destruction' approach. So far, all protein structure determinations carried out using FELs have been based on previous knowledge of related, known structures. Here we show that X-ray FEL data can be used for de novo protein structure determination, that is, without previous knowledge about the structure. Using the emerging technique of serial femtosecond crystallography, we performed single-wavelength anomalous scattering measurements on microcrystals of the well-established model system lysozyme, in complex with a lanthanide compound. Using Monte-Carlo integration, we obtained high-quality diffraction intensities from which experimental phases could be determined, resulting in an experimental electron density map good enough for automated building of the protein structure. This demonstrates the feasibility of determining novel protein structures using FELs. We anticipate that serial femtosecond crystallography will become an important tool for the structure determination of proteins that are difficult to crystallize, such as membrane proteins.


Assuntos
Cristalografia/métodos , Elétrons , Lasers , Proteínas/química , Difração de Raios X/métodos , Raios X , Animais , Galinhas , Cristalização , Feminino , Gadolínio , Proteínas de Membrana/química , Modelos Moleculares , Método de Monte Carlo , Muramidase/química , Conformação Proteica , Fatores de Tempo
4.
Proc Natl Acad Sci U S A ; 114(9): 2247-2252, 2017 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-28202732

RESUMO

To understand how molecules function in biological systems, new methods are required to obtain atomic resolution structures from biological material under physiological conditions. Intense femtosecond-duration pulses from X-ray free-electron lasers (XFELs) can outrun most damage processes, vastly increasing the tolerable dose before the specimen is destroyed. This in turn allows structure determination from crystals much smaller and more radiation sensitive than previously considered possible, allowing data collection from room temperature structures and avoiding structural changes due to cooling. Regardless, high-resolution structures obtained from XFEL data mostly use crystals far larger than 1 µm3 in volume, whereas the X-ray beam is often attenuated to protect the detector from damage caused by intense Bragg spots. Here, we describe the 2 Å resolution structure of native nanocrystalline granulovirus occlusion bodies (OBs) that are less than 0.016 µm3 in volume using the full power of the Linac Coherent Light Source (LCLS) and a dose up to 1.3 GGy per crystal. The crystalline shell of granulovirus OBs consists, on average, of about 9,000 unit cells, representing the smallest protein crystals to yield a high-resolution structure by X-ray crystallography to date. The XFEL structure shows little to no evidence of radiation damage and is more complete than a model determined using synchrotron data from recombinantly produced, much larger, cryocooled granulovirus granulin microcrystals. Our measurements suggest that it should be possible, under ideal experimental conditions, to obtain data from protein crystals with only 100 unit cells in volume using currently available XFELs and suggest that single-molecule imaging of individual biomolecules could almost be within reach.


Assuntos
Cristalografia/métodos , Elétrons , Granulovirus/ultraestrutura , Peptídeos e Proteínas de Sinalização Intercelular/química , Lasers , Cristalografia/instrumentação , Granulovirus/química , Modelos Moleculares , Progranulinas , Estrutura Secundária de Proteína , Síncrotrons
5.
Proc Natl Acad Sci U S A ; 111(35): 12769-74, 2014 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-25136092

RESUMO

It has long been known that toxins produced by Bacillus thuringiensis (Bt) are stored in the bacterial cells in crystalline form. Here we describe the structure determination of the Cry3A toxin found naturally crystallized within Bt cells. When whole Bt cells were streamed into an X-ray free-electron laser beam we found that scattering from other cell components did not obscure diffraction from the crystals. The resolution limits of the best diffraction images collected from cells were the same as from isolated crystals. The integrity of the cells at the moment of diffraction is unclear; however, given the short time (∼ 5 µs) between exiting the injector to intersecting with the X-ray beam, our result is a 2.9-Å-resolution structure of a crystalline protein as it exists in a living cell. The study suggests that authentic in vivo diffraction studies can produce atomic-level structural information.


Assuntos
Bacillus thuringiensis/química , Proteínas de Bactérias/química , Cristalografia por Raios X/métodos , Endotoxinas/química , Proteínas Hemolisinas/química , Esporos Bacterianos/química , Bacillus thuringiensis/ultraestrutura , Toxinas de Bacillus thuringiensis , Cristalização , Cristalografia por Raios X/instrumentação , Lasers , Esporos Bacterianos/ultraestrutura , Síncrotrons , Difração de Raios X
6.
Acta Crystallogr D Biol Crystallogr ; 71(Pt 2): 387-97, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25664750

RESUMO

Recent advances in synchrotron sources, beamline optics and detectors are driving a renaissance in room-temperature data collection. The underlying impetus is the recognition that conformational differences are observed in functionally important regions of structures determined using crystals kept at ambient as opposed to cryogenic temperature during data collection. In addition, room-temperature measurements enable time-resolved studies and eliminate the need to find suitable cryoprotectants. Since radiation damage limits the high-resolution data that can be obtained from a single crystal, especially at room temperature, data are typically collected in a serial fashion using a number of crystals to spread the total dose over the entire ensemble. Several approaches have been developed over the years to efficiently exchange crystals for room-temperature data collection. These include in situ collection in trays, chips and capillary mounts. Here, the use of a slowly flowing microscopic stream for crystal delivery is demonstrated, resulting in extremely high-throughput delivery of crystals into the X-ray beam. This free-stream technology, which was originally developed for serial femtosecond crystallography at X-ray free-electron lasers, is here adapted to serial crystallography at synchrotrons. By embedding the crystals in a high-viscosity carrier stream, high-resolution room-temperature studies can be conducted at atmospheric pressure using the unattenuated X-ray beam, thus permitting the analysis of small or weakly scattering crystals. The high-viscosity extrusion injector is described, as is its use to collect high-resolution serial data from native and heavy-atom-derivatized lysozyme crystals at the Swiss Light Source using less than half a milligram of protein crystals. The room-temperature serial data allow de novo structure determination. The crystal size used in this proof-of-principle experiment was dictated by the available flux density. However, upcoming developments in beamline optics, detectors and synchrotron sources will enable the use of true microcrystals. This high-throughput, high-dose-rate methodology provides a new route to investigating the structure and dynamics of macromolecules at ambient temperature.


Assuntos
Cristalografia por Raios X/instrumentação , Síncrotrons/instrumentação , Animais , Galinhas , Cristalografia por Raios X/economia , Cristalografia por Raios X/métodos , Desenho de Equipamento , Modelos Moleculares , Muramidase/química , Temperatura , Viscosidade
7.
J Synchrotron Radiat ; 22(3): 634-43, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25931079

RESUMO

X-ray free-electron laser sources such as the Linac Coherent Light Source offer very exciting possibilities for unique research. However, beam time at such facilities is very limited and in high demand. This has led to significant efforts towards beam multiplexing of various forms. One such effort involves re-using the so-called spent beam that passes through the hole in an area detector after a weak interaction with a primary sample. This beam can be refocused into a secondary interaction region and used for a second, independent experiment operating in series. The beam profile of this refocused beam was characterized for a particular experimental geometry at the Coherent X-ray Imaging instrument at LCLS. A demonstration of this multiplexing capability was performed with two simultaneous serial femtosecond crystallography experiments, both yielding interpretable data of sufficient quality to produce electron density maps.

8.
J Synchrotron Radiat ; 22(3): 644-52, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25931080

RESUMO

Serial femtosecond crystallography (SFX) is an emerging method for data collection at free-electron lasers (FELs) in which single diffraction snapshots are taken from a large number of crystals. The partial intensities collected in this way are then combined in a scheme called Monte Carlo integration, which provides the full diffraction intensities. However, apart from having to perform this merging, the Monte Carlo integration must also average out all variations in crystal quality, crystal size, X-ray beam properties and other factors, necessitating data collection from thousands of crystals. Because the pulses provided by FELs running in the typical self-amplified spontaneous emission (SASE) mode of operation have very irregular, spiky spectra that vary strongly from pulse to pulse, it has been suggested that this is an important source of variation contributing to inaccuracies in the intensities, and that, by using monochromatic pulses produced through a process called self-seeding, fewer images might be needed for Monte Carlo integration to converge, resulting in more accurate data. This paper reports the results of two experiments performed at the Linac Coherent Light Source in which data collected in both SASE and self-seeded mode were compared. Importantly, no improvement attributable to the use of self-seeding was detected. In addition, other possible sources of variation that affect SFX data quality were investigated, such as crystal-to-crystal variations reflected in the unit-cell parameters; however, these factors were found to have no influence on data quality either. Possibly, there is another source of variation as yet undetected that affects SFX data quality much more than any of the factors investigated here.

9.
J Synchrotron Radiat ; 22(2): 225-38, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25723924

RESUMO

Proteins that contain metal cofactors are expected to be highly radiation sensitive since the degree of X-ray absorption correlates with the presence of high-atomic-number elements and X-ray energy. To explore the effects of local damage in serial femtosecond crystallography (SFX), Clostridium ferredoxin was used as a model system. The protein contains two [4Fe-4S] clusters that serve as sensitive probes for radiation-induced electronic and structural changes. High-dose room-temperature SFX datasets were collected at the Linac Coherent Light Source of ferredoxin microcrystals. Difference electron density maps calculated from high-dose SFX and synchrotron data show peaks at the iron positions of the clusters, indicative of decrease of atomic scattering factors due to ionization. The electron density of the two [4Fe-4S] clusters differs in the FEL data, but not in the synchrotron data. Since the clusters differ in their detailed architecture, this observation is suggestive of an influence of the molecular bonding and geometry on the atomic displacement dynamics following initial photoionization. The experiments are complemented by plasma code calculations.


Assuntos
Ferredoxinas/efeitos da radiação , Metaloproteínas/efeitos da radiação , Síncrotrons , Clostridium/efeitos da radiação , Cristalografia por Raios X/métodos , Relação Dose-Resposta à Radiação , Humanos , Modelos Moleculares , Lesões por Radiação , Sensibilidade e Especificidade
10.
J Appl Crystallogr ; 57(Pt 2): 529-538, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38596720

RESUMO

Data collection at X-ray free electron lasers has particular experimental challenges, such as continuous sample delivery or the use of novel ultrafast high-dynamic-range gain-switching X-ray detectors. This can result in a multitude of data artefacts, which can be detrimental to accurately determining structure-factor amplitudes for serial crystallography or single-particle imaging experiments. Here, a new data-classification tool is reported that offers a variety of machine-learning algorithms to sort data trained either on manual data sorting by the user or by profile fitting the intensity distribution on the detector based on the experiment. This is integrated into an easy-to-use graphical user interface, specifically designed to support the detectors, file formats and software available at most X-ray free electron laser facilities. The highly modular design makes the tool easily expandable to comply with other X-ray sources and detectors, and the supervised learning approach enables even the novice user to sort data containing unwanted artefacts or perform routine data-analysis tasks such as hit finding during an experiment, without needing to write code.

11.
J Mol Biol ; 436(5): 168439, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38185322

RESUMO

The understanding of signal transduction mechanisms in photoreceptor proteins is essential for elucidating how living organisms respond to light as environmental stimuli. In this study, we investigated the ATP binding, photoactivation and signal transduction process in the photoactivatable adenylate cyclase from Oscillatoria acuminata (OaPAC) upon blue light excitation. Structural models with ATP bound in the active site of native OaPAC at cryogenic as well as room temperature are presented. ATP is found in one conformation at cryogenic- and in two conformations at ambient-temperature, and is bound in an energetically unfavorable conformation for the conversion to cAMP. However, FTIR spectroscopic experiments confirm that this conformation is the native binding mode in dark state OaPAC and that transition to a productive conformation for ATP turnover only occurs after light activation. A combination of time-resolved crystallography experiments at synchrotron and X-ray Free Electron Lasers sheds light on the early events around the Flavin Adenine Dinucleotide (FAD) chromophore in the light-sensitive BLUF domain of OaPAC. Early changes involve the highly conserved amino acids Tyr6, Gln48 and Met92. Crucially, the Gln48 side chain performs a 180° rotation during activation, leading to the stabilization of the FAD chromophore. Cryo-trapping experiments allowed us to investigate a late light-activated state of the reaction and revealed significant conformational changes in the BLUF domain around the FAD chromophore. In particular, a Trpin/Metout transition upon illumination is observed for the first time in the BLUF domain and its role in signal transmission via α-helix 3 and 4 in the linker region between sensor and effector domain is discussed.


Assuntos
Adenilil Ciclases , Proteínas de Bactérias , Oscillatoria , Fotorreceptores Microbianos , Trifosfato de Adenosina/química , Adenilil Ciclases/química , Adenilil Ciclases/efeitos da radiação , Proteínas de Bactérias/química , Proteínas de Bactérias/efeitos da radiação , Flavina-Adenina Dinucleotídeo/química , Transdução de Sinais , Espectroscopia de Infravermelho com Transformada de Fourier , Oscillatoria/enzimologia , Domínio Catalítico , Triptofano/química , Metionina/química , Fotorreceptores Microbianos/química , Fotorreceptores Microbianos/efeitos da radiação , Ativação Enzimática
12.
Artigo em Inglês | MEDLINE | ID: mdl-23989164

RESUMO

High-resolution ribosome structures determined by X-ray crystallography have provided important insights into the mechanism of translation. Such studies have thus far relied on large ribosome crystals kept at cryogenic temperatures to reduce radiation damage. Here, the application of serial femtosecond X-ray crystallography (SFX) using an X-ray free-electron laser (XFEL) to obtain diffraction data from ribosome microcrystals in liquid suspension at ambient temperature is described. 30S ribosomal subunit microcrystals diffracted to beyond 6 Šresolution, demonstrating the feasibility of using SFX for ribosome structural studies. The ability to collect diffraction data at near-physiological temperatures promises to provide fundamental insights into the structural dynamics of the ribosome and its functional complexes.


Assuntos
Elétrons , Subunidades Ribossômicas Menores de Bactérias/ultraestrutura , Thermus thermophilus/química , Cristalização , Cristalografia por Raios X , Lasers , Subunidades Ribossômicas Menores de Bactérias/química , Temperatura , Difração de Raios X
13.
Structure ; 31(11): 1306-1319, 2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37898125

RESUMO

Serial femtosecond crystallography (SFX) revolutionized macromolecular crystallography over the past decade by enabling the collection of X-ray diffraction data from nano- or micrometer sized crystals while outrunning structure-altering radiation damage effects at room temperature. The serial manner of data collection from millions of individual crystals coupled with the femtosecond duration of the ultrabright X-ray pulses enables time-resolved studies of macromolecules under near-physiological conditions to unprecedented temporal resolution. In 2020 the rapid spread of the coronavirus SARS-CoV-2 resulted in a global pandemic of coronavirus disease-2019. This led to a shift in how serial femtosecond experiments were performed, along with rapid funding and free electron laser beamtime availability dedicated to SARS-CoV-2-related studies. This review outlines the current state of SFX research, the milestones that were achieved, the impact of the global pandemic on this field as well as an outlook into exciting future directions.


Assuntos
COVID-19 , Pandemias , Humanos , Cristalografia/métodos , Cristalografia por Raios X , COVID-19/epidemiologia , SARS-CoV-2 , Difração de Raios X , Substâncias Macromoleculares/química
14.
Acta Crystallogr D Struct Biol ; 79(Pt 10): 944-952, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37747292

RESUMO

Over the past two decades, serial X-ray crystallography has enabled the structure determination of a wide range of proteins. With the advent of X-ray free-electron lasers (XFELs), ever-smaller crystals have yielded high-resolution diffraction and structure determination. A crucial need to continue advancement is the efficient delivery of fragile and micrometre-sized crystals to the X-ray beam intersection. This paper presents an improved design of an all-polymer microfluidic `chip' for room-temperature fixed-target serial crystallography that can be tailored to broadly meet the needs of users at either synchrotron or XFEL light sources. The chips are designed to be customized around different types of crystals and offer users a friendly, quick, convenient, ultra-low-cost and robust sample-delivery platform. Compared with the previous iteration of the chip [Gilbile et al. (2021), Lab Chip, 21, 4831-4845], the new design eliminates cleanroom fabrication. It has a larger imaging area to volume, while maintaining crystal hydration stability for both in situ crystallization or direct crystal slurry loading. Crystals of two model proteins, lysozyme and thaumatin, were used to validate the effectiveness of the design at both synchrotron (lysozyme and thaumatin) and XFEL (lysozyme only) facilities, yielding complete data sets with resolutions of 1.42, 1.48 and 1.70 Å, respectively. Overall, the improved chip design, ease of fabrication and high modifiability create a powerful, all-around sample-delivery tool that structural biologists can quickly adopt, especially in cases of limited sample volume and small, fragile crystals.


Assuntos
Cicloparafinas , Muramidase , Cristalografia , Muramidase/química , Microfluídica/métodos , Temperatura , Desenho de Equipamento , Cristalografia por Raios X , Proteínas , Polímeros
15.
Structure ; 31(2): 138-151.e5, 2023 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-36630960

RESUMO

NendoU from SARS-CoV-2 is responsible for the virus's ability to evade the innate immune system by cleaving the polyuridine leader sequence of antisense viral RNA. Here we report the room-temperature structure of NendoU, solved by serial femtosecond crystallography at an X-ray free-electron laser to 2.6 Å resolution. The room-temperature structure provides insight into the flexibility, dynamics, and other intrinsic properties of NendoU, with indications that the enzyme functions as an allosteric switch. Functional studies examining cleavage specificity in solution and in crystals support the uridine-purine cleavage preference, and we demonstrate that enzyme activity is fully maintained in crystal form. Optimizing the purification of NendoU and identifying suitable crystallization conditions set the benchmark for future time-resolved serial femtosecond crystallography studies. This could advance the design of antivirals with higher efficacy in treating coronaviral infections, since drugs that block allosteric conformational changes are less prone to drug resistance.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , Cristalografia por Raios X , Temperatura , Elétrons , Lasers
16.
Lab Chip ; 23(13): 3016-3033, 2023 06 28.
Artigo em Inglês | MEDLINE | ID: mdl-37294576

RESUMO

Droplet injection strategies are a promising tool to reduce the large amount of sample consumed in serial femtosecond crystallography (SFX) measurements at X-ray free electron lasers (XFELs) with continuous injection approaches. Here, we demonstrate a new modular microfluidic droplet injector (MDI) design that was successfully applied to deliver microcrystals of the human NAD(P)H:quinone oxidoreductase 1 (NQO1) and phycocyanin. We investigated droplet generation conditions through electrical stimulation for both protein samples and implemented hardware and software components for optimized crystal injection at the Macromolecular Femtosecond Crystallography (MFX) instrument at the Stanford Linac Coherent Light Source (LCLS). Under optimized droplet injection conditions, we demonstrate that up to 4-fold sample consumption savings can be achieved with the droplet injector. In addition, we collected a full data set with droplet injection for NQO1 protein crystals with a resolution up to 2.7 Å, leading to the first room-temperature structure of NQO1 at an XFEL. NQO1 is a flavoenzyme associated with cancer, Alzheimer's and Parkinson's disease, making it an attractive target for drug discovery. Our results reveal for the first time that residues Tyr128 and Phe232, which play key roles in the function of the protein, show an unexpected conformational heterogeneity at room temperature within the crystals. These results suggest that different substates exist in the conformational ensemble of NQO1 with functional and mechanistic implications for the enzyme's negative cooperativity through a conformational selection mechanism. Our study thus demonstrates that microfluidic droplet injection constitutes a robust sample-conserving injection method for SFX studies on protein crystals that are difficult to obtain in amounts necessary for continuous injection, including the large sample quantities required for time-resolved mix-and-inject studies.


Assuntos
Lasers , Proteínas , Humanos , Cristalografia por Raios X , Proteínas/química , Injeções , NAD(P)H Desidrogenase (Quinona)
17.
STAR Protoc ; 3(1): 101158, 2022 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-35194584

RESUMO

The SARS-CoV-2 main protease of (Mpro) is an important target for SARS-CoV-2 related drug repurposing and development studies. Here, we describe the steps for structural characterization of SARS-CoV-2 Mpro, starting from plasmid preparation and protein purification. We detail the steps for crystallization using the sitting drop, microbatch (under oil) approach. Finally, we cover data collection and structure determination using serial femtosecond crystallography. For complete details on the use and execution of this protocol, please refer to Durdagi et al. (2021).


Assuntos
Proteases 3C de Coronavírus/química , Modelos Moleculares , SARS-CoV-2/enzimologia , Proteases 3C de Coronavírus/genética , Cristalização , Cristalografia por Raios X , Humanos
18.
Commun Biol ; 5(1): 73, 2022 01 20.
Artigo em Inglês | MEDLINE | ID: mdl-35058563

RESUMO

Multimeric protein assemblies are abundant in nature. Streptavidin is an attractive protein that provides a paradigm system to investigate the intra- and intermolecular interactions of multimeric protein complexes. Also, it offers a versatile tool for biotechnological applications. Here, we present two apo-streptavidin structures, the first one is an ambient temperature Serial Femtosecond X-ray crystal (Apo-SFX) structure at 1.7 Å resolution and the second one is a cryogenic crystal structure (Apo-Cryo) at 1.1 Å resolution. These structures are mostly in agreement with previous structural data. Combined with computational analysis, these structures provide invaluable information about structural dynamics of apo streptavidin. Collectively, these data further reveal a novel cooperative allostery of streptavidin which binds to substrate via water molecules that provide a polar interaction network and mimics the substrate biotin which displays one of the strongest affinities found in nature.


Assuntos
Estreptavidina/ultraestrutura , Temperatura
19.
Biophys Rep (N Y) ; 2(4): 100081, 2022 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-36425668

RESUMO

With advances in X-ray free-electron lasers (XFELs), serial femtosecond crystallography (SFX) has enabled the static and dynamic structure determination for challenging proteins such as membrane protein complexes. In SFX with XFELs, the crystals are typically destroyed after interacting with a single XFEL pulse. Therefore, thousands of new crystals must be sequentially introduced into the X-ray beam to collect full data sets. Because of the serial nature of any SFX experiment, up to 99% of the sample delivered to the X-ray beam during its "off-time" between X-ray pulses is wasted due to the intrinsic pulsed nature of all current XFELs. To solve this major problem of large and often limiting sample consumption, we report on improvements of a revolutionary sample-saving method that is compatible with all current XFELs. We previously reported 3D-printed injection devices coupled with gas dynamic virtual nozzles (GDVNs) capable of generating samples containing droplets segmented by an immiscible oil phase for jetting crystal-laden droplets into the path of an XFEL. Here, we have further improved the device design by including metal electrodes inducing electrowetting effects for improved control over droplet generation frequency to stimulate the droplet release to matching the XFEL repetition rate by employing an electrical feedback mechanism. We report the improvements in this electrically triggered segmented flow approach for sample conservation in comparison with a continuous GDVN injection using the microcrystals of lysozyme and 3-deoxy-D-manno-octulosonate 8-phosphate synthase and report the segmented flow approach for sample injection applied at the Macromolecular Femtosecond Crystallography instrument at the Linear Coherent Light Source for the first time.

20.
Structure ; 29(12): 1382-1396.e6, 2021 12 02.
Artigo em Inglês | MEDLINE | ID: mdl-34403647

RESUMO

The COVID-19 pandemic has resulted in 198 million reported infections and more than 4 million deaths as of July 2021 (covid19.who.int). Research to identify effective therapies for COVID-19 includes: (1) designing a vaccine as future protection; (2) de novo drug discovery; and (3) identifying existing drugs to repurpose them as effective and immediate treatments. To assist in drug repurposing and design, we determine two apo structures of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) main protease at ambient temperature by serial femtosecond X-ray crystallography. We employ detailed molecular simulations of selected known main protease inhibitors with the structures and compare binding modes and energies. The combined structural and molecular modeling studies not only reveal the dynamics of small molecules targeting the main protease but also provide invaluable opportunities for drug repurposing and structure-based drug design strategies against SARS-CoV-2.


Assuntos
Tratamento Farmacológico da COVID-19 , Proteases 3C de Coronavírus/química , Desenho de Fármacos , Reposicionamento de Medicamentos , SARS-CoV-2 , Domínio Catalítico , Simulação por Computador , Cristalografia por Raios X , Dimerização , Conformação Molecular , Simulação de Acoplamento Molecular , Análise de Componente Principal , Conformação Proteica , Proteínas Recombinantes/química , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA