Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Nucl Med Technol ; 35(2): 80-3, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17496007

RESUMO

UNLABELLED: Obesity has reached epidemic proportions in the United States; hence, it is frequently encountered in patients undergoing (18)F-FDG PET studies. The purpose of the current study was to present a technologist's perspective on the prevalence of obesity and the challenges and solutions in imaging obese patients in our PET facility. METHODS: From October 2002 to October 2003, whole-body (18)F-FDG PET was performed on 1,164 patients with a known or suspected malignancy. Images were acquired 45-60 min after (18)F-FDG injection (7.4 MBq [0.2 mCi]/kg, with a maximum of 925 MBq [25 mCi]) on a PET scanner using a 4-min emission and 3-min transmission time per bed position. A database was maintained of patient height and weight, and body mass index (BMI) was calculated. Patient obesity was classified as overweight (BMI > or = 25 kg/m(2)), obese (BMI > or = 30 kg/m(2)), or malignantly obese (BMI > or = 40 kg/m(2)). In addition, PET technologists recorded any problems and attempted solutions related to the patient weight. RESULTS: BMI calculations showed that 528 patients (45.4%) were overweight or obese (322 men and 206 women; mean age, 55 y). Of those, 201 (38%) were overweight, 270 (51%) were obese, and 57 (11%) were malignantly obese. Problems encountered in these patients included difficult intravenous access (15%), difficult patient positioning (10%), patient motion (7%), an incomplete study (emission only) (1%), and potentially higher radiation exposure to the technologist because of extra time spent near the patient. Attempted solutions included adjusting the schedule to allow more time per patient, adjusting the dose based on body weight, using varied positioning techniques, dividing the study to allow a respite between different image combinations, and dividing time spent with obese patients among the technologists involved. CONCLUSION: Excessive body weight and related problems have commonly been encountered in our PET facility. (18)F-FDG PET studies of obese patients represent an ongoing challenge, which requires patient-tailored solutions to avoid compromising image quality and risking higher radiation exposure to the technologists.


Assuntos
Artefatos , Índice de Massa Corporal , Fluordesoxiglucose F18 , Obesidade/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/estatística & dados numéricos , Medição de Risco/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Missouri/epidemiologia , Prevalência , Compostos Radiofarmacêuticos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA