1.
Entropy (Basel) ; 24(6)2022 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-35741558

RESUMO

This paper introduces a closed-form expression for the Kullback-Leibler divergence (KLD) between two central multivariate Cauchy distributions (MCDs) which have been recently used in different signal and image processing applications where non-Gaussian models are needed. In this overview, the MCDs are surveyed and some new results and properties are derived and discussed for the KLD. In addition, the KLD for MCDs is showed to be written as a function of Lauricella D-hypergeometric series FD(p). Finally, a comparison is made between the Monte Carlo sampling method to approximate the KLD and the numerical value of the closed-form expression of the latter. The approximation of the KLD by Monte Carlo sampling method are shown to converge to its theoretical value when the number of samples goes to the infinity.

2.
Ultrasonics ; 54(5): 1289-99, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24529339

RESUMO

This study proposes a new method for automatic, iterative image registration in the context of dynamic contrast-enhanced ultrasound (DCE-US) imaging. By constructing a cost function of image registration using a combination of the tissue and contrast-microbubble responses, this new method, referred to as dual-mode registration, performs alignment based on both tissue and vascular structures. Data from five focal liver lesions (FLLs) were used for the evaluation. Automatic registration based on the dual-mode registration technique and tissue-mode registration obtained using the linear response image sequence alone were compared to manual alignment of the sequence by an expert. Comparison of the maximum distance between the transformations applied by the automatic registration techniques and those from expert manual registration reference showed that the dual-mode registration provided better precision than the tissue-mode registration for all cases. The reduction of maximum distance ranged from 0.25 to 9.3mm. Dual-mode registration is also significantly better than tissue-mode registration for the five sequences with p-values lower than 0.03. The improved sequence alignment is also demonstrated visually by comparison of images from the sequences and the video playbacks of the motion-corrected sequences. This new registration technique better maintains a selected region of interest (ROI) within a fixed position of the image plane throughout the DCE-US sequence. This should reduce motion-related variability of the echo-power estimations and, thus, contribute to more robust perfusion quantification with DCE-US.


Assuntos
Neoplasias Colorretais/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Meios de Contraste , Humanos , Interpretação de Imagem Assistida por Computador , Modelos Teóricos , Fosfolipídeos , Software , Hexafluoreto de Enxofre , Transdutores , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA