Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Cancer Radiother ; 26(1-2): 50-58, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34953689

RESUMO

We present the update of the recommendations of the French society of oncological radiotherapy on respiratory motion management for external radiotherapy treatment. Since twenty years and the report 62 of ICRU, motion management during the course of radiotherapy treatment has become an increasingly significant concern, particularly with the development of hypofractionated treatments under stereotactic conditions, using reduced safety margins. This article related orders of motion amplitudes for different organs as well as the definition of the margins in radiotherapy. An updated review of the various movement management strategies is presented as well as main technological solutions enabling them to be implemented: when acquiring anatomical data, during planning and when carrying out treatment. Finally, the management of these moving targets, such as it can be carried out in radiotherapy departments, will be detailed for a few concrete examples of localizations (abdominal, thoracic and hepatic).


Assuntos
Neoplasias Abdominais/radioterapia , Suspensão da Respiração , Movimentos dos Órgãos , Respiração , Espirometria/métodos , Neoplasias Torácicas/radioterapia , Neoplasias Abdominais/diagnóstico por imagem , Expiração , França , Humanos , Inalação , Imageamento por Ressonância Magnética , Movimentos dos Órgãos/fisiologia , Aceleradores de Partículas , Radioterapia (Especialidade) , Planejamento da Radioterapia Assistida por Computador , Sociedades Médicas , Neoplasias Torácicas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
2.
Br J Radiol ; 93(1110): 20190692, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32293191

RESUMO

OBJECTIVE: The internal target volume (ITV) strategy generates larger planning target volumes (PTVs) in locally advanced non-small cell lung cancer (LA-NSCLC) than the Mid-position (Mid-p) strategy. We investigated the benefit of the Mid-p strategy regarding PTV reduction and dose to the organs at risk (OARs). METHODS: 44 patients with LA-NSCLC were included in a randomized clinical study to compare ITV and Mid-p strategies. GTV were delineated by a physician on maximum intensity projection images and on Mid-p images from four-dimensional CTs. CTVs were obtained by adding 6 mm uniform margin for microscopic extension. CTV to PTV margins were calculated using the van Herk's recipe for setup and delineation errors. For the Mid-p strategy, the mean target motion amplitude was added as a random error. For both strategies, three-dimensional conformal plans delivering 60-66 Gy to PTV were performed. PTVs, dose-volume parameters for OARs (lung, esophagus, heart, spinal cord) were reported and compared. RESULTS: With the Mid-p strategy, the median of volume reduction was 23.5 cm3 (p = 0.012) and 8.8 cm3 (p = 0.0083) for PTVT and PTVN respectively; the median mean lung dose reduction was 0.51 Gy (p = 0.0057). For 37.1% of the patients, delineation errors led to smaller PTV with the ITV strategy than with the Mid-p strategy. CONCLUSION: PTV and mean lung dose were significantly reduced using the Mid-p strategy. Delineation uncertainty can unfavorably impact the advantage. ADVANCES IN KNOWLEDGE: To the best of our knowledge, this is the first dosimetric comparison study between ITV and Mid-p strategies for LA-NSCLC.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/radioterapia , Neoplasias Pulmonares/radioterapia , Movimentos dos Órgãos , Respiração , Idoso , Plexo Braquial/diagnóstico por imagem , Plexo Braquial/efeitos da radiação , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/patologia , Esôfago/diagnóstico por imagem , Esôfago/efeitos da radiação , Tomografia Computadorizada Quadridimensional , Coração/diagnóstico por imagem , Coração/efeitos da radiação , Humanos , Pulmão/diagnóstico por imagem , Pulmão/efeitos da radiação , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Órgãos em Risco/diagnóstico por imagem , Órgãos em Risco/efeitos da radiação , Estudos Prospectivos , Lesões por Radiação/prevenção & controle , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia Conformacional/métodos , Medula Espinal/diagnóstico por imagem , Medula Espinal/efeitos da radiação , Carga Tumoral
3.
Cancer Radiother ; 19(5): 303-7, 2015 Aug.
Artigo em Francês | MEDLINE | ID: mdl-26206733

RESUMO

PURPOSE: This work evaluated the interobserver variability in cone beam computed tomography (CBCT) registration for prostate cancers treated with intensity-modulated radiotherapy. MATERIAL AND METHODS: Twelve technologists realized 286 CBCT/CT registrations (bone registration followed by prostate to prostate registration). The registration results were compared to those obtained by two radiation oncologists (reference). Each technologist reported the shifts calculated by the software in all three axes. A statistical analysis allowed us to calculate the minimum threshold under which 95% of the observers found similar values. A variance analysis followed by the post hoc test were used to find differences in interobserver registration variability and determine whether any individual users performed registrations which differed significantly from those of the other users. RESULTS: The registration differences compared to the reference in the three directions in terms of 95th percentile are: 2.1mm left-right, 3.5mm target-gun, 7.3mm anterior-posterior. In the posterior direction, 4% of the observers have found differences superior to 8mm, margin used in routine without the use of a daily CBCT. The variance test revealed a P-value <0.05 only for target-gun and for all observers there was no significant difference compared to the reference. CONCLUSION: This study confirmed the interest of a 3D tissue registration for prostate treatments. The registration study showed a good interobserver reproducibility. This showed the importance of a daily CBCT/CT registration in prostate treatment with the possibility of a planning target volume margin reduction in the three directions. An evaluation of a partial delegation of registration to technologists should be done by the radiation oncologists.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Radioterapia Guiada por Imagem/métodos , Radioterapia de Intensidade Modulada , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/radioterapia , Fracionamento da Dose de Radiação , Humanos , Imageamento Tridimensional , Masculino , Variações Dependentes do Observador , Radioterapia de Intensidade Modulada/métodos
4.
Cancer Radiother ; 18(5-6): 406-13, 2014 Oct.
Artigo em Francês | MEDLINE | ID: mdl-25219608

RESUMO

Intensity modulated radiotherapy is increasingly used in non-small-cell lung cancers despite a low level of evidence. A literature review was conducted. Several critical physical and dosimetric uncertainties are however unsolved. Methods to circumvent these limitations are being developed. In several retrospective studies, survival rates were at least similar with intensity-modulated radiotherapy as those reported with three-dimensional irradiation. To date, intensity modulated radiotherapy might be authorized in complex anatomical situations such as tumours close to the spinal cord (such as Pancoast Tobias, paraspinal and paracardiac tumours) or with limited motion amplitudes. Dosimetric benefits should also account for 4D dose distribution issues. The reduction of intermediate and high doses in the organs at risk with intensity modulated radiotherapy is advantageous. However, the effect of low doses in large volumes (lung, bone, unspecified tissues along beam paths) and the effect of increasing integral dose are still poorly known. In conclusion, dose-volume correlations need to be better documented and prospective randomized trials should be encouraged.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/radioterapia , Neoplasias Pulmonares/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Artefatos , Carcinoma Pulmonar de Células não Pequenas/terapia , Quimiorradioterapia , Estudos Epidemiológicos , Esofagite/etiologia , Esofagite/prevenção & controle , Tomografia Computadorizada Quadridimensional , Humanos , Neoplasias Pulmonares/terapia , Movimento (Física) , Órgãos em Risco , Lesões por Radiação/etiologia , Lesões por Radiação/prevenção & controle , Pneumonite por Radiação/etiologia , Pneumonite por Radiação/prevenção & controle , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/efeitos adversos , Mecânica Respiratória , Resultado do Tratamento
5.
Cancer Radiother ; 15(2): 115-22, 2011 Apr.
Artigo em Francês | MEDLINE | ID: mdl-21112229

RESUMO

AIM OF THE STUDY: In the case of lung tumor treatment, to adjust 3D helical computed tomography (CT) acquisition parameters using a dynamic phantom and compare to the theory the volumes of a moving object. MATERIALS AND METHODS: Three helical CT acquisitions were compared using a Big Bore CT scan : an "initial" 3D CT scan (constructor parameters), an "optimized" 3D CT scan which parameters are chosen to obtain an axial slow scan like acquisition and a 4D CT scan. We used a phantom composed by a ball filled with water set on a dynamic platform moving in the antero-posterior or cranio-caudal direction with a 14 mm amplitude and a 4s period. For each acquisition and modality (static and dynamic), we quantified the ball volume by automatic contouring and we estimated relative errors. RESULTS: For an antero-posterior displacement, the volume of the moving ball is under estimated by 14.1 % with the "initial" scan, by 0.2 % with the "optimized" scan and over estimated by 0.8 % with the averaged 4D scan. For a cranio-caudal displacement, it is under estimated by about 22 % with the "initial" scan and by about 1 % with the "optimized" scan and the averaged 4D scan. CONCLUSION: Volume measurements performed with the dynamic phantom allowed us to validate the "optimized" 3D CT scan parameters because it accurately reflects the volume of a moving object. Radiotherapy departments without 4D CT should adapt scan parameters for internal target volume definition.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Movimento , Imagens de Fantasmas , Tomografia Computadorizada Quadridimensional/métodos , Humanos , Imageamento Tridimensional/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada Espiral/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA