Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
J Med Genet ; 61(4): 305-312, 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38154813

RESUMO

BACKGROUND: National and international amalgamation of genomic data offers opportunity for research and audit, including analyses enabling improved classification of variants of uncertain significance. Review of individual-level data from National Health Service (NHS) testing of cancer susceptibility genes (2002-2023) submitted to the National Disease Registration Service revealed heterogeneity across participating laboratories regarding (1) the structure, quality and completeness of submitted data, and (2) the ease with which that data could be assembled locally for submission. METHODS: In May 2023, we undertook a closed online survey of 51 clinical scientists who provided consensus responses representing all 17 of 17 NHS molecular genetic laboratories in England and Wales which undertake NHS diagnostic analyses of cancer susceptibility genes. The survey included 18 questions relating to 'next-generation sequencing workflow' (11), 'variant classification' (3) and 'phenotypical context' (4). RESULTS: Widely differing processes were reported for transfer of variant data into their local LIMS (Laboratory Information Management System), for the formatting in which the variants are stored in the LIMS and which classes of variants are retained in the local LIMS. Differing local provisions and workflow for variant classifications were also reported, including the resources provided and the mechanisms by which classifications are stored. CONCLUSION: The survey responses illustrate heterogeneous laboratory workflow for preparation of genomic variant data from local LIMS for centralised submission. Workflow is often labour-intensive and inefficient, involving multiple manual steps which introduce opportunities for error. These survey findings and adoption of the concomitant recommendations may support improvement in laboratory dataflows, better facilitating submission of data for central amalgamation.


Assuntos
Laboratórios , Neoplasias , Humanos , Fluxo de Trabalho , Medicina Estatal , Genômica , Reino Unido
2.
Perfusion ; : 2676591231168291, 2023 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-36990441

RESUMO

BACKGROUND: There are limited practical advanced life support algorithms to aid teams in the management of cardiac arrest in patients on extracorporeal membrane oxygenation (ECMO). METHODS: In our specialist tertiary referral centre we developed, by iteration, a novel resuscitation algorithm for ECMO emergencies which we validated through simulation and assessment of our multi-disciplinary team. A Mechanical Life Support course was established to provide theoretical and practical education combined with simulation to consolidate knowledge and confidence in algorithm use. We assessed these measures using confidence scoring, a key performance indicator (the time taken to resolve gas line disconnection) and a multiple choice question (MCQ) examination. RESULTS: Following this intervention the median confidence scores increased from 2 (Interquartile range IQR 2, 3) to 4 (IQR 4, 4) out of maximum 5 (n = 53, p < 0.0001). Theoretical knowledge assessed by median MCQ score increased from 8 (6, 9) to 9 (7, 10) out of maximum 11 (n = 53, p0.0001). The use of the ECMO algorithm reduced the time taken by teams in a simulated emergency to identify a gas line disconnection and resolve the problem from median 128 s (65, 180) to 44 s (31, 59) (n = 36, p 0.001) and by a mean of 81.5 s (CI 34, 116, p = 0.001). CONCLUSIONS: We present an evidence based practical ECMO resuscitation algorithm that provides guidance to clinical teams responding to cardiac arrest in ECMO patients covering both patient and ECMO troubleshooting.

3.
Perfusion ; 38(8): 1670-1681, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-36148887

RESUMO

INTRODUCTION: Thrombosis and bleeding are major complications in patients supported with left ventricular assist devices (LVADs). We aimed to assess the incidence of bleeding and thrombosis in patients supported with a HeartWare left ventricular assist device (HVAD), their predictive factors and their impact on mortality. METHODS: A single centre retrospective observational study of patients supported with HVAD over 5 years from January 2015 to October 2020. RESULTS: A total 139 patients (median age 52.5, 72.1% male) were included for analysis. The probability of 1-year survival was 73.1%. Advanced age (>60 years) and EuroSCORE II score (>20%) were independently associated with reduced survival. Major bleeding and thrombosis occurred in 46.8% and 35.3% respectively. Secondary mechanical circulatory support (MCS) increased likelihood of experiencing major bleeding (HR: 2.76, 95%1.65-4.62, p < 0.0001) whilst patients receiving aspirin were protected from bleeding and thrombosis (HR: 0.34 95% CI 0.19-0.58, p < 0.001). Pre-operative anaemia (HR: 3.02, 95% CI: 1.6-5.7, p = 0.014) and use of a secondary MCS device (HR: 2.78, 95% CI: 1.2-6.3, p = 0.001) were associated with an increased risk of thrombosis. Patients with any major bleeding (with or without thrombosis) had a 7.68-fold (95% CI 3.5-16.8) increased risk of death compared to those without. In contrast, 'thrombosis only' patients had 4.23-fold (95% CI 1.8-10.2) increased risk of death compared to those without thrombosis. The risk of mortality was increased in patients with any thrombosis and the risk of death was highest in patients with major bleeding and thrombosis (HR: 16.49 [95% CI 7.7-35.3]). CONCLUSIONS: Major bleeding and thrombosis significantly increase the 1-year mortality. Optimal perioperative haemostasis and anticoagulation remains crucial in patients supported with HVAD.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Trombose , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Choque Cardiogênico/cirurgia , Choque Cardiogênico/complicações , Coração Auxiliar/efeitos adversos , Hemorragia/complicações , Trombose/etiologia , Estudos Retrospectivos , Resultado do Tratamento
4.
Clin Endocrinol (Oxf) ; 96(4): 499-512, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34558728

RESUMO

OBJECTIVE: Phaeochromocytomas and paragangliomas (PPGL) are rare, but strongly heritable tumours. Variants in succinate dehydrogenase (SDH) subunits are identified in approximately 25% of cases. However, clinical and genetic information of patients with SDHC variants are underreported. DESIGN: This retrospective case series collated data from 18 UK Genetics and Endocrinology departments. PATIENTS: Both asymptomatic and disease-affected patients with confirmed SDHC germline variants are included. MEASUREMENTS: Clinical data including tumour type and location, surveillance outcomes and interventions, SDHC genetic variant assessment, interpretation, and tumour risk calculation. RESULTS: We report 91 SDHC cases, 46 probands and 45 non-probands. Fifty-one cases were disease-affected. Median age at genetic diagnosis was 43 years (range: 11-79). Twenty-four SDHC germline variants were identified including six novel variants. Head and neck paraganglioma (HNPGL, n = 30, 65.2%), extra-adrenal paraganglioma (EAPGL, n = 13, 28.2%) and phaeochromocytomas (PCC) (n = 3, 6.5%) were present. One case had multiple PPGLs. Malignant disease was reported in 19.6% (9/46). Eight cases had non-PPGL SDHC-associated tumours, six gastrointestinal stromal tumours (GIST) and two renal cell cancers (RCC). Cumulative tumour risk (95% CI) at age 60 years was 0.94 (CI: 0.79-0.99) in probands, and 0.16 (CI: 0-0.31) in non-probands, respectively. CONCLUSIONS: This study describes the largest cohort of 91 SDHC patients worldwide. We confirm disease-affected SDHC variant cases develop isolated HNPGL disease in nearly 2/3 of patients, EAPGL and PCC in 1/3, with an increased risk of GIST and RCC. One fifth developed malignant disease, requiring comprehensive lifelong tumour screening and surveillance.


Assuntos
Neoplasias das Glândulas Suprarrenais , Carcinoma de Células Renais , Tumores do Estroma Gastrointestinal , Neoplasias Renais , Paraganglioma , Feocromocitoma , Neoplasias das Glândulas Suprarrenais/genética , Feminino , Mutação em Linhagem Germinativa/genética , Humanos , Masculino , Proteínas de Membrana/genética , Pessoa de Meia-Idade , Paraganglioma/genética , Paraganglioma/patologia , Feocromocitoma/genética , Feocromocitoma/patologia , Estudos Retrospectivos , Succinato Desidrogenase/genética , Succinato Desidrogenase/metabolismo , Reino Unido
5.
Clin Endocrinol (Oxf) ; 95(2): 295-302, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33340421

RESUMO

OBJECTIVE: Diagnostic germline RET analysis is offered to all patients with a diagnosis of medullary thyroid carcinoma (MTC), or other conditions associated with multiple endocrine neoplasia type 2 (MEN2) in the United Kingdom. Here, we report the experience of a single centre's germline RET analysis over a 21-year period. DESIGN: Retrospective case-note review. PATIENTS: All index patients referred to the Exeter Genomics Laboratory for diagnostic germline RET analysis between 1997 and 2018, and unaffected family members, undergoing predictive testing. MEASUREMENTS: The rate and nature of pathogenic variant detection were recorded, as well as the indication for testing. RESULTS: 1,058 index patients and 551 unaffected family members were tested. The overall rate of pathogenic variant detection was 10.2% amongst index patients and 29% amongst unaffected family members. The commonest indication was isolated MTC, and amongst the 690 patients with isolated MTC, 68 (9.9%) were found to harbour a RET pathogenic variant. Of those with presumed sporadic MTC, 8.5% were found to harbour germline RET pathogenic variants, compared with 36.4% of those with a family history of MEN2-associated conditions. Pathogenic variants were identified in 3.6% and 0% of patients with isolated phaeochromocytoma and primary hyperparathyroidism, respectively. CONCLUSIONS: Although the detection rate of RET germline pathogenic variants in patients with presumed sporadic MTC was significant, the overall detection rate in those with MTC was lower than expected in this series. Advances in RET analysis in response to reports of new variants over the last two decades are likely to have improved the pick-up rate in recent years.


Assuntos
Neoplasias das Glândulas Suprarrenais , Neoplasia Endócrina Múltipla Tipo 2a , Neoplasias da Glândula Tireoide , Testes Genéticos , Mutação em Linhagem Germinativa , Humanos , Neoplasia Endócrina Múltipla Tipo 2a/diagnóstico , Neoplasia Endócrina Múltipla Tipo 2a/genética , Proto-Oncogene Mas , Proteínas Proto-Oncogênicas c-ret/genética , Estudos Retrospectivos , Neoplasias da Glândula Tireoide/diagnóstico , Neoplasias da Glândula Tireoide/genética , Reino Unido
6.
Emerg Med J ; 34(12): 842-850, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29127102

RESUMO

Advances in left ventricular assist device (LVAD) therapy have resulted in increasing numbers of adult LVAD recipients in the community. However, device failure, stroke, bleeding, LVAD thrombosis and systemic infection can be life-threatening emergencies. Currently, four LVAD systems are implanted in six UK transplant centres, each of which provides device-specific information to local emergency services. This has resulted in inconsistent availability and content of information with the risks of delayed or inappropriate decision-making. In order to improve patient safety, a consortium of UK healthcare professionals with expertise in LVADs developed universally applicable prehospital emergency algorithms. Guidance was framed as closely as possible on the standard ABCDE approach to the assessment of critically ill patients.


Assuntos
Algoritmos , Ambulâncias , Serviços Médicos de Emergência/normas , Tratamento de Emergência/normas , Insuficiência Cardíaca/terapia , Coração Auxiliar , Emergências , Falha de Equipamento , Humanos , Reino Unido
7.
Artif Organs ; 40(6): 549-60, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26611518

RESUMO

The aim of this study was to elucidate the dynamic characteristics of the Thoratec HeartMate II (HMII) and the HeartWare HVAD (HVAD) left ventricular assist devices (LVADs) under clinically representative in vitro operating conditions. The performance of the two LVADs were compared in a normothermic, human blood-filled mock circulation model under conditions of steady (nonpulsatile) flow and under simulated physiologic conditions. These experiments were repeated using 5% dextrose in order to determine its suitability as a blood analog. Under steady flow conditions, for the HMII, approximately linear inverse LVAD differential pressure (H) versus flow (Q) relationships were observed with good correspondence between the results of blood and 5% dextrose under all conditions except at a pump speed of 9000 rpm. For the HVAD, the corresponding relationships were inverse curvilinear and with good correspondence between the blood-derived and 5% dextrose-derived relationships in the flow rate range of 2-6 L/min and at pump speeds up to 3000 rpm. Under pulsatile operating conditions, for each LVAD operating at a particular pump speed, an counterclockwise loop was inscribed in the HQ domain during a simulated cardiac cycle (HQ loop); this showed that there was a variable phase relationship between LVAD differential pressure and LVAD flow. For both the HMII and HVAD, increasing pump speed was associated with a right-hand and upward shift of the HQ loop and simulation of impairment of left ventricular function was associated with a decrease in loop area. During clinical use, not only does the pressure differential across the LVAD and its flow rate vary continuously, but their phase relationship is variable. This behavior is inadequately described by the widely accepted representation of a plot of pressure differential versus flow derived under steady conditions. We conclude that the dynamic HQ loop is a more meaningful representation of clinical operating conditions than the widely accepted steady flow HQ curve.


Assuntos
Coração Auxiliar , Fluxo Pulsátil , Simulação por Computador , Hemodinâmica , Humanos , Hidrodinâmica , Modelos Cardiovasculares , Pressão , Função Ventricular Esquerda
8.
J Surg Res ; 195(1): 311-4, 2015 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-25617972

RESUMO

BACKGROUND: Donation after cardiocirculatory death (DCD) has lead to an increase in organ availability. However, because of medical, logistic, and ethical issues, the use of hearts from DCD donors for transplantation is not generally considered to be feasible. In this study, we investigated the feasibility of ex vivo resuscitation and assessment of the porcine heart after circulatory death using the organ care system (OCS). METHODS: Cardiocirculatory death was induced in five pigs by cessation of mechanical ventilation. No heparin was administered. The agonal time (AT) was calculated as the time between a reduction of blood pressure <50 mm Hg or a fall in saturation beneath 70% and the cessation of electrical activity. After a further 15 min of warm ischemia, hearts were procured and implanted into the OCS, mimicking the actual clinical scenario for other organs. Thus, procured grafts were assessed ex vivo over a period of 4 h. RESULTS: Four hearts were successfully resuscitated on the system (AT 8, 15, 20, and 34 min) Three grafts had excellent visual contractility and lactate trends and were considered to be transplantable. One graft (AT 34 min) had an increased lactate and abnormal contractility being unsuitable for transplantation. One heart with 48-min AT could not be resuscitated. CONCLUSIONS: Our data show that hearts from nonheparinized DCD porcine donors can be successfully resuscitated using the OCS in a scenario, which closely simulates clinical conditions.


Assuntos
Morte , Preservação de Órgãos , Perfusão/métodos , Animais , Ácido Láctico/análise , Masculino , Modelos Animais , Suínos , Obtenção de Tecidos e Órgãos
9.
Artif Organs ; 39(2): 118-25, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24841499

RESUMO

The Synergy Micro-pump is the smallest implantable left ventricular assist device (LVAD) and provides partial flow support up to 4.25 L/min. It was shown that early intervention with this device can provide substantial benefits to patients with severe heart failure not yet sick enough for a full-support LVAD. However, as it can be inserted via small incisions with no need for sternotomy or cardiopulmonary bypass, it might be beneficial for selected high-risk patients. The aim of this study was to evaluate the efficacy of the Synergy Micro-pump in patients in INTERMACS class 1-2. From February 2012 to August 2013, 13 patients with severe heart failure were supported with the Synergy Pocket Micro-pump. Patients were divided into two groups according to INTERMACS class: the high-risk group (INTERMACS class 1-2) and the low-risk group (INTERMACS class 3-4). There were seven patients in INTERMACS class 1-2 and six in INTERMACS class 3-4. Patient demographics, perioperative characteristics, and postoperative outcomes were compared. There were no statistically significant differences in patient demographics, and mean support time was 108 ± 114 days in the high-risk group and 238 ± 198 days in the low-risk group. Also, there were no significant differences in perioperative characteristics or in the rate of postoperative adverse events. The overall survival was comparable between the two groups (one late death in each group, log-rank P = 0.608). Two patients from the high-risk group were upgraded to a full-support LVAD (P = 0.462) after 65 ± 84.9 days of mean support. One patient from the high-risk group and two patients from the low-risk group were successfully transplanted (P = 0.559). The use of the Synergy Micro-pump in INTERMACS 1-2 patients is feasible and is associated with similar postoperative outcome as in patients in INTERMACS 3-4. Carefully selected patients with severe heart failure could benefit due to the small size of the pump; however, further studies and medium-term follow-up are required.


Assuntos
Insuficiência Cardíaca/cirurgia , Transplante de Coração , Coração Auxiliar , Adulto , Ponte Cardiopulmonar , Feminino , Seguimentos , Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Análise de Sobrevida
10.
J Artif Organs ; 17(4): 364-5, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24973025

RESUMO

Arthrogryposis multiplex congenita (AMC) is characterized by contractions of multiple joints present at birth. AMC is rarely associated with cardiomyopathy. We present a case of a young man with dilated cardiomyopathy associated with AMC admitted with rapidly deteriorating severe heart failure who was offered left ventricular assist device as a bridge to transplant.


Assuntos
Artrogripose/complicações , Cardiomiopatias/cirurgia , Coração Auxiliar , Adulto , Cardiomiopatias/complicações , Humanos , Masculino , Resultado do Tratamento
11.
J Am Heart Assoc ; 13(9): e032617, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38686903

RESUMO

BACKGROUND: We evaluated the potential benefits of renin-angiotensin-aldosterone system inhibitors (RAASi) in patients with left ventricular assist device support. METHODS AND RESULTS: A total of 165 consecutive patients undergoing left ventricular assist device implant and alive at 6-month on support were studied. RAASi status after 6-month visit along with clinical reasons for nonprescription/uptitration were retrospectively assessed. The primary outcome was a composite of heart failure hospitalization or cardiovascular death between 6 and 24 months after left ventricular assist device implant. Remodeling and hemodynamic outcomes were explored by studying the association of RAASi new prescription/uptitration versus unmodified therapy at 6-month visit with the change in echocardiographic parameters and hemodynamics between 6 and 18 months. After the 6-month visit, 76% of patients were on RAASi. Patients' characteristics among those receiving and not receiving RAASi were mostly similar. Of 85 (52%) patients without RAASi new prescription/uptitration at 6-month visit, 62% had no apparent clinical reason. RAASi were independently associated with the primary outcome (adjusted hazard ratio, 0.31 [95% CI, 0.16-0.69]). The baseline rates of optimal echocardiographic profile (neutral interventricular septum, mitral regurgitation less than mild, and aortic valve opening) and hemodynamic profile (cardiac index ≥2.2 L/min per m2, wedge pressure <18 mm Hg, and right atrial pressure <12 mm Hg) were similar between groups. At 18 months, patients receiving RAASi new prescription/uptitration at 6 months had higher rates of optimal hemodynamic profile (57.5% versus 37.0%; P=0.032) and trends for higher rates of optimal echocardiographic profile (39.6% versus 22.9%; P=0.055) compared with patients with 6-month unmodified therapy. Optimal 18-month hemodynamic and echocardiographic profiles were associated with the primary outcome (log-rank=0.022 and log-rank=0.035, respectively). CONCLUSIONS: RAASi are associated with improved outcomes and improved hemodynamics among mechanically unloaded patients.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Hemodinâmica , Sistema Renina-Angiotensina , Remodelação Ventricular , Humanos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/tratamento farmacológico , Insuficiência Cardíaca/mortalidade , Masculino , Feminino , Pessoa de Meia-Idade , Remodelação Ventricular/efeitos dos fármacos , Estudos Retrospectivos , Hemodinâmica/efeitos dos fármacos , Sistema Renina-Angiotensina/efeitos dos fármacos , Resultado do Tratamento , Idoso , Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Função Ventricular Esquerda/efeitos dos fármacos , Antagonistas de Receptores de Angiotensina/uso terapêutico , Fatores de Tempo , Ecocardiografia
12.
Intensive Care Med ; 50(4): 493-501, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38526578

RESUMO

An implantable left ventricular assist device (LVAD) is indicated as a bridge to transplantation or recovery in the United Kingdom (UK). The mechanism of action of the LVAD results in a unique state of haemodynamic stability with diminished arterial pulsatility. The clinical assessment of an LVAD recipient can be challenging because non-invasive blood pressure, pulse and oxygen saturation measurements may be hard to obtain. As a result of this unusual situation and complex interplay between the device and the native circulation, resuscitation of LVAD recipients requires bespoke guidelines. Through collaboration with key UK stakeholders, we assessed the current evidence base and developed guidelines for the recognition of clinical deterioration, inadequate circulation and time-critical interventions. Such guidelines, intended for use in transplant centres, are designed to be deployed by those providing immediate care of LVAD patients under conditions of precipitous clinical deterioration. In summary, the Joint British Societies and Transplant Centres LVAD Working Group present the UK guideline on management of emergencies in implantable LVAD recipients for use in advanced heart failure centres. These recommendations have been made with a UK resuscitation focus but are widely applicable to professionals regularly managing patients with implantable LVADs.


Assuntos
Deterioração Clínica , Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Humanos , Emergências , Insuficiência Cardíaca/terapia
13.
J Thorac Cardiovasc Surg ; 166(4): 1119-1129.e1, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-35379474

RESUMO

OBJECTIVE: Due to severely limited donor heart availability, durable mechanical circulatory support remains the only treatment option for many patients with end-stage heart failure. However, treatment complexity persists due to its univentricular support modality and continuous contact with blood. We investigated the function and safety of reBEAT (AdjuCor GmbH), a novel, minimal invasive mechanical circulatory support device that completely avoids blood contact and provides pulsatile, biventricular support. METHODS: For each animal tested, an accurately sized cardiac implant was manufactured from computed tomography scan analyses. The implant consists of a cardiac sleeve with three inflatable cushions, 6 epicardial electrodes and driveline connecting to an electro-pneumatic, extracorporeal portable driver. Continuous epicardial electrocardiogram signal analysis allows for systolic and diastolic synchronization of biventricular mechanical support. In 7 pigs (weight, 50-80 kg), data were analyzed acutely (under beta-blockade, n = 5) and in a 30-day long-term survival model (n = 2). Acquisition of intracardiac pressures and aortic and pulmonary flow data were used to determine left ventricle and right ventricle stroke work and stroke volume, respectively. RESULTS: Each implant was successfully positioned around the ventricles. Automatic algorithm electrocardiogram signal annotations resulted in precise, real-time mechanical support synchronization with each cardiac cycle. Consequently, progressive improvements in cardiac hemodynamic parameters in acute animals were achieved. Long-term survival demonstrated safe device integration, and clear and stable electrocardiogram signal detection over time. CONCLUSIONS: The present study demonstrates biventricular cardiac support with reBEAT. Various demonstrated features are essential for realistic translation into the clinical setting, including safe implantation, anatomical fit, safe device-tissue integration, and real-time electrocardiogram synchronized mechanical support, result in effective device function and long-term safety.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Animais , Suínos , Humanos , Doadores de Tecidos , Hemodinâmica
14.
Circulation ; 123(4): 381-90, 2011 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-21242487

RESUMO

BACKGROUND: We have previously shown that a specific combination of drug therapy and left ventricular assist device unloading results in significant myocardial recovery, sufficient to allow pump removal, in two thirds of patients with dilated cardiomyopathy receiving a Heartmate I pulsatile device. However, this protocol has not been used with nonpulsatile devices. METHODS AND RESULTS: We report the results of a prospective study of 20 patients who received a combination of angiotensin-converting enzymes, ß-blockers, angiotensin II inhibitors, and aldosterone antagonists followed by the ß2-agonist clenbuterol and were regularly tested (echocardiograms, exercise tests, catheterizations) with the pump at low speed. Before left ventricular assist device insertion, patient age was 35.2 ± 12.6 years (16 male patients), patients were on 2.0 ± 0.9 inotropes, 7 (35) had an intra-aortic balloon pump, 2 were hemofiltered, 2 were ventilated, 3 had a prior Levitronix device, and 1 had extracorporeal membrane oxygenation. Cardiac index was 1.39 ± 0.43 L · min⁻¹ · m⁻², pulmonary capillary wedge pressure was 31.5 ± 5.7 mm Hg, and heart failure history was 3.4 ± 3.5 years. One patient was lost to follow-up and died after 240 days of support. Of the remaining 19 patients, 12 (63.2) were explanted after 286 ± 97 days. Eight had symptomatic heart failure for ≤6 months and 4 for >6 months (48 to 132 months). Before explantation, at low flow for 15 minutes, ejection fraction was 70 ± 7, left ventricular end-diastolic diameter was 48.6 ± 5.7 mm, left ventricular end-systolic diameter was 32.3 ± 5.7 mm, mV(O2) was 21.6 ± 4 mL · kg⁻¹ · min⁻¹, pulmonary capillary wedge pressure was 5.9 ± 4.6 mm Hg, and cardiac index was 3.6 ± 0.6 L · min⁻¹ · m⁻². Estimated survival without heart failure recurrence was 83.3 at 1 and 3 years. After a 430.7 ± 337.1-day follow-up, surviving explants had an ejection fraction of 58.1 ± 13.8, left ventricular end-diastolic diameter of 59.0 ± 9.3 mm, left ventricular end-systolic diameter of 42.0 ± 10.7 mm, and mV(O2) of 22.6 ± 5.3 mL · kg⁻¹ · min⁻¹. CONCLUSIONS: Reversal of end-stage heart failure secondary to nonischemic cardiomyopathy can be achieved in a substantial proportion of patients with nonpulsatile flow through the use of a combination of mechanical and pharmacological therapy.


Assuntos
Cardiomiopatia Dilatada/terapia , Insuficiência Cardíaca/terapia , Coração Auxiliar , Disfunção Ventricular Esquerda/terapia , Adulto , Cardiomiopatia Dilatada/tratamento farmacológico , Fármacos Cardiovasculares/uso terapêutico , Clembuterol/uso terapêutico , Feminino , Insuficiência Cardíaca/tratamento farmacológico , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Índice de Gravidade de Doença , Volume Sistólico/efeitos dos fármacos , Resultado do Tratamento , Disfunção Ventricular Esquerda/tratamento farmacológico , Adulto Jovem
15.
Interact Cardiovasc Thorac Surg ; 34(2): 322-325, 2022 01 18.
Artigo em Inglês | MEDLINE | ID: mdl-34849924

RESUMO

Although the activated partial thromboplastin time (aPTT) has historically been the method of choice for anticoagulation monitoring in patients undergoing mechanical circulatory support with intravenous unfractionated heparin, it is being progressively superseded by the anti-factor Xa (anti-Xa) method. A retrospective single-arm, single-centre analysis of 20 patients who underwent total artificial heart implantation entailed simultaneous determinations of aPTT and anti-Xa. Agreement between these parameters was assessed using the Bland-Altman method. Despite a positive correlation between aPTT and anti-Xa, normal target ranges were poorly aligned: from 5th to 30th postoperative day, for anti-Xa values of 0.2 and 0.4 U/ml corresponding aPTT values were 52.1 and 65.2 s, 7.9 and 14.8 lower than predicted values, respectively. This was not associated with thromboembolic sequalae. It was not possible to demonstrate a significant relationship between the predictor variables (postoperative day; white blood cell count; C-reactive protein concentration; alanine transaminase and alkaline phosphatase level; bilirubin; haemoglobin; albumin and total protein concentration) and the agreement between aPTT and anti-Xa levels. In summary, when anti-Xa levels were used to guide anticoagulation therapy, corresponding aPTT levels were low with respect to target range. Methodology applied in this study is generalizable to other forms of mechanical circulatory support.


Assuntos
Coração Artificial , Heparina , Anticoagulantes/efeitos adversos , Monitoramento de Medicamentos/métodos , Inibidores do Fator Xa/efeitos adversos , Heparina/efeitos adversos , Humanos , Tempo de Tromboplastina Parcial , Estudos Retrospectivos
16.
Resusc Plus ; 10: 100254, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35669526

RESUMO

Background: Published guidance concerning emergency management of left ventricular assist device (LVAD) recipients is both limited and lacking in consensus which increases the risk of delayed and/or inappropriate actions. Methods: In our specialist tertiary referral centre we developed, by iteration, a novel in-hospital resuscitation algorithm for LVAD emergencies which we validated through simulation and assessment of our multi-disciplinary team. A Mechanical Life Support course was established to provide theoretical and practical education combined with simulation to consolidate knowledge and confidence in algorithm use. We assessed these measures using confidence scoring, a key performance indicator (the time taken to restart LVAD function) and a multiple-choice question (MCQ) examination. Results: The mean baseline staff confidence score in management of LVAD emergencies was 2.4 ± 1.2 out of a maximum of 5 (n = 29). After training with simulation, mean confidence score increased to 3.5 ± 0.8 (n = 13).Clinical personnel who were provided with the novel resuscitation algorithm were able to reduce time taken to restart LVAD function from a mean value of 49 ± 8.2 seconds (pre-training) to 20.4 ± 5 seconds (post-training) (n = 42, p < 0.0001).The Mechanical Life Support course increased mean confidence from 2.5 ± 1.2 to 4 ± 0.6 (n = 44, p < 0.0001) and mean MCQ score from 18.7 ± 3.4 to 22.8 ± 2.6, out of a maximum of 28 (n = 44, p < 0.0001). Conclusion: We present a simplified LVAD Advanced Life Support algorithm to aid the crucial first minutes of resuscitation where basic interventions are likely to be critical in assuring good patient outcomes.

17.
J Mol Cell Cardiol ; 51(3): 390-8, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21740909

RESUMO

Electrophysiological and pharmacological data from the human heart are limited due to the absence of simple but representative experimental model systems of human myocardium. The aim of this study was to establish and characterise adult human myocardial slices from small patients' heart biopsies as a simple, reproducible and relevant preparation suitable for the study of human cardiac tissue at the multicellular level. Vibratome-cut myocardial slices were prepared from left ventricular biopsies obtained from end-stage heart failure patients undergoing heart transplant or ventricular assist device implantation, and from hearts of normal dogs. Multiple slices were prepared from each biopsy. Regular contractility was observed at a range of stimulation frequencies (0.1-2 Hz), and stable electrical activity, monitored using multi-electrode arrays (MEA), was maintained for at least 8 h from slice preparation. ATP/ADP and phosphocreatine/creatine ratios were comparable to intact organ values, and morphology and gap junction distribution were representative of native myocardium. MEA recordings showed that field potential duration (FPD) and conduction velocity (CV) in human and dog slices were similar to the values previously reported for papillary muscles, ventricular wedges and whole hearts. Longitudinal CV was significantly faster than transversal CV, with an anisotropic ratio of 3:1 for human and 2.3:1 for dog slices. Importantly, slices responded to the application of E-4031, chromanol and 4-aminopyridine, three potassium channel blockers known to affect action potential duration, with an increase in FPD. We conclude that viable myocardial slices with preserved structural, biochemical and electrophysiological properties can be prepared from adult human and canine heart biopsies and offer a novel preparation suitable for the study of heart failure and drug screening.


Assuntos
Coração/efeitos dos fármacos , Coração/fisiologia , Adulto , Animais , Cães , Fenômenos Eletrofisiológicos/efeitos dos fármacos , Fenômenos Eletrofisiológicos/fisiologia , Sistema de Condução Cardíaco/efeitos dos fármacos , Sistema de Condução Cardíaco/fisiologia , Humanos , Técnicas In Vitro , Pessoa de Meia-Idade , Miocárdio/metabolismo , Miocárdio/patologia , Bloqueadores dos Canais de Potássio/farmacologia , Sobrevivência de Tecidos/fisiologia
18.
Ann Thorac Surg ; 111(2): 511-518, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32698021

RESUMO

BACKGROUND: We investigated changes in estimated glomerular filtration rate (eGFR) after left ventricular assist device (LVAD) implant and the impact on long-term outcomes. METHODS: A retrospective analysis was conducted for 255 patients with LVADs, divided into 2 groups based on preimplant eGFR (<60 or >60 mL/min/1.73 m2) and into 6 grades (grade 1, >90 mL/min/1.73 m2 normal; grade 2, 60-89 mild dysfunction; grade 3, 45-59 moderate; grade 4, 30-44 moderate to severe; grade 5, 15-29 severe; or grade 6, <15 kidney failure). Changes in eGFR and the impact on long-term outcome and survival were analyzed. RESULTS: One-month postimplant eGFR of the total cohort increased from a baseline of 75.19 ± 34.35 to 118.97 ± 67.62 mL/min/1.73 m2(P < .001). eGRF 4 years postimplant was higher than baseline but not significantly (P = .48). Patients with a preimplant eGFR > 60 followed the same pattern as the entire cohort. The preimplant eGFR < 60 group had a significant increase at 1 month (P < .001), eGFR remained significantly higher than baseline 4 years postimplant (P = .032), and there was a sustained transition to improved distribution of renal function grade after LVAD implant. Post-LVAD implant survival at 1, 3, and 5 years for baseline eGFR > 60 was 76%, 54%, and 48% and for eGFR < 60 was 71%, 60%, and 48%, respectively (P = .92). CONCLUSIONS: Patients with a low preimplant eGFR derive benefit from LVAD therapy, with eGFR remaining elevated above preimplant levels. Preimplant renal dysfunction did not impact negatively on long-term morbidity and mortality.


Assuntos
Taxa de Filtração Glomerular , Insuficiência Cardíaca/terapia , Coração Auxiliar , Adulto , Idoso , Feminino , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
19.
N Engl J Med ; 355(18): 1873-84, 2006 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-17079761

RESUMO

BACKGROUND: In patients with severe heart failure, prolonged unloading of the myocardium with the use of a left ventricular assist device has been reported to lead to myocardial recovery in small numbers of patients for varying periods of time. Increasing the frequency and durability of myocardial recovery could reduce or postpone the need for subsequent heart transplantation. METHODS: We enrolled 15 patients with severe heart failure due to nonischemic cardiomyopathy and with no histologic evidence of active myocarditis. All had markedly reduced cardiac output and were receiving inotropes. The patients underwent implantation of left ventricular assist devices and were treated with lisinopril, carvedilol, spironolactone, and losartan to enhance reverse remodeling. Once regression of left ventricular enlargement had been achieved, the beta2-adrenergic-receptor agonist clenbuterol was administered to prevent myocardial atrophy. RESULTS: Eleven of the 15 patients had sufficient myocardial recovery to undergo explantation of the left ventricular assist device a mean (+/-SD) of 320+/-186 days after implantation of the device. One patient died of intractable arrhythmias 24 hours after explantation; another died of carcinoma of the lung 27 months after explantation. The cumulative rate of freedom from recurrent heart failure among the surviving patients was 100% and 88.9% 1 and 4 years after explantation, respectively. The quality of life as assessed by the Minnesota Living with Heart Failure Questionnaire score at 3 years was nearly normal. Fifty-nine months after explantation, the mean left ventricular ejection fraction was 64+/-12%, the mean left ventricular end-diastolic diameter was 59.4+/-12.1 mm, the mean left ventricular end-systolic diameter was 42.5+/-13.2 mm, and the mean maximal oxygen uptake with exercise was 26.3+/-6.0 ml per kilogram of body weight per minute. CONCLUSIONS: In this single-center study, we found that sustained reversal of severe heart failure secondary to nonischemic cardiomyopathy could be achieved in selected patients with the use of a left ventricular assist device and a specific pharmacologic regimen.


Assuntos
Agonistas Adrenérgicos beta/uso terapêutico , Cardiomiopatia Dilatada/tratamento farmacológico , Cardiomiopatia Dilatada/cirurgia , Fármacos Cardiovasculares/uso terapêutico , Coração Auxiliar , Adolescente , Agonistas de Receptores Adrenérgicos beta 2 , Adulto , Pressão Sanguínea , Débito Cardíaco , Cardiomiopatia Dilatada/mortalidade , Cardiomiopatia Dilatada/fisiopatologia , Clembuterol/uso terapêutico , Terapia Combinada , Feminino , Transplante de Coração , Coração Auxiliar/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Oxigênio/sangue , Estudos Prospectivos , Falha de Prótese , Taxa de Sobrevida
20.
Cardiovasc Revasc Med ; 20(11S): 63-66, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31326257

RESUMO

In patients with cardiogenic shock, the global use of percutaneous mechanical circulatory support using the Impella CP device has increased with early data suggesting potential benefits over conservative management. In the current case report we describe a simple technique facilitating percutaneous Impella CP or RP exchange with preservation of transfemoral access, which does not require the use of a 0.035' wire. This technique allows for percutaneous sealing of the 14F arteriotomy using new closure devices avoiding the traditional cut-down.


Assuntos
Infarto Miocárdico de Parede Anterior/complicações , Cateterismo Periférico , Remoção de Dispositivo , Artéria Femoral , Coração Auxiliar , Implantação de Prótese/instrumentação , Infarto do Miocárdio com Supradesnível do Segmento ST/complicações , Choque Cardiogênico/terapia , Função Ventricular Esquerda , Infarto Miocárdico de Parede Anterior/diagnóstico , Infarto Miocárdico de Parede Anterior/fisiopatologia , Técnicas Hemostáticas/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Punções , Recuperação de Função Fisiológica , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/etiologia , Choque Cardiogênico/fisiopatologia , Resultado do Tratamento , Dispositivos de Oclusão Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA