1.
Kardiologiia ; 57(7): 52-60, 2017 07.
Artigo em Russo | MEDLINE | ID: mdl-29041881

RESUMO

AIM: To study relationship between age-associated changes of heart rate variability (HRV), telomere length (TL), and lowering of insulin sensitivity (IS). MATERIAL AND METHODS: We included in this study 229 individuals aged 23‒91 years without clinical manifestations of cardiovascular and other somatic diseases. In all participants, we analyzed HRV parameters obtained at 24-hour ECG monitoring (24-h ECG) and 5 minutes ECG recordings in the supine and standing positions. Leukocyte TL was estimated on genomic DNA using real time polymerase chain reaction. Insulin sensitivity was characterized by calculation of НОМА-IR and Gutt's insulin sensitivity index (ISI). RESULTS: Elderly people with short telomeres (.


Assuntos
Envelhecimento , Frequência Cardíaca , Resistência à Insulina , Homeostase do Telômero , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Envelhecimento/genética , Envelhecimento/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Telômero
2.
Rev Sci Instrum ; 90(5): 053303, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31153246

RESUMO

The ion-production efficiency of a newly developed singly charged ion source (SCIS) has been investigated to discuss the possibility of it being used in an isotope separation on-line system that provides 11C ions for heavy-ion cancer therapy with simultaneous verification of the irradiation field using positron emission tomography. The SCIS uses a low-energy hollow electron beam to produce singly charged carbon ions efficiently. To deliver sufficient 11C ions to the treatment room from a limited amount of 11C molecules, which are produced from a boron compound target and proton-beam irradiation via the 11B(p,n)11C reaction, the SCIS must have high ion-production efficiency. To realize this high efficiency, the SCIS was designed using a three-dimensional particle-in-cell code in previous work. With the fabricated SCIS, we performed experiments to measure the efficiency of producing CO2 + ions from nonradioactive 12CO2 molecules and C+ ions from nonradioactive 12CH4 molecules. We found that the SCIS achieved efficiencies of εC+ =4×10-3 (0.4%) for C+ production and εCO2 + =0.107 (10.7%) for CO2 + production.


Assuntos
Radioisótopos de Carbono/uso terapêutico , Radioterapia com Íons Pesados , Neoplasias/radioterapia , Radioquímica/métodos , Desenho de Equipamento , Radioquímica/instrumentação
3.
Rev Sci Instrum ; 89(11): 113302, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30501292

RESUMO

A singly charged ion source (SCIS) has been designed using a newly developed three-dimensional particle-in-cell (PIC) code. The SCIS is to be used in an isotope separation on-line (ISOL) system that provides 11C ions for heavy-ion cancer therapy with simultaneous verification of the dose distribution using positron emission tomography. The SCIS uses low-energy electron beams to produce singly charged carbon ions efficiently and maintain a high vacuum in the ISOL system. Because the SCIS has to realize a production efficiency of 1% if its carbon ions are to be used in the ISOL system, a suitable design for the SCIS was investigated by using the developed PIC code to study the beam trajectories of the electrons and extracted ions. The simulation results show that hollow electron beams are produced in the designed SCIS resulting in a high effective electron current. The results also predict that the designed SCIS would realize ion-production efficiencies (IPEs) of ε SCIS ≃ 6.7% for C O 2 + production from CO2 gas and ε SCIS ≃ 0.1% for C+ production from CH4 gas. Moreover, to examine the validity of the developed code and confirm that the SCIS was able to be designed appropriately, the space-charge-limited current of the electron gun and the total IPE obtained by adding the IPEs of each ion were compared between the experiment and the simulation.

4.
Rev Sci Instrum ; 87(2): 02A913, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26931974

RESUMO

An assembly for a commercial Ga(+) liquid metal ion source in combination with an ion transportation and focusing system, a pulse high-voltage quadrupole deflector, and a beam diagnostics system has been constructed in the framework of the iThemba LABS (Cape Town, South Africa)-JINR (Dubna, Russia) collaboration. First, results on Ga(+) ion beam commissioning will be presented. Outlook of further experiments for measurements of charge breeding efficiency in the electron string ion source with the use of external injection of Ga(+) and Au(+) ion beams will be reported as well.

5.
Rev Sci Instrum ; 86(12): 123303, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26724018

RESUMO

A (11)C molecular production/separation system (CMPS) has been developed as part of an isotope separation on line system for simultaneous positron emission tomography imaging and heavy-ion cancer therapy using radioactive (11)C ion beams. In the ISOL system, (11)CH4 molecules will be produced by proton irradiation and separated from residual air impurities and impurities produced during the irradiation. The CMPS includes two cryogenic traps to separate specific molecules selectively from impurities by using vapor pressure differences among the molecular species. To investigate the fundamental performance of the CMPS, we performed separation experiments with non-radioactive (12)CH4 gases, which can simulate the chemical characteristics of (11)CH4 gases. We investigated the separation of CH4 molecules from impurities, which will be present as residual gases and are expected to be difficult to separate because the vapor pressure of air molecules is close to that of CH4. We determined the collection/separation efficiencies of the CMPS for various amounts of air impurities and found desirable operating conditions for the CMPS to be used as a molecular separation device in our ISOL system.


Assuntos
Radioisótopos de Carbono/química , Radioisótopos de Carbono/isolamento & purificação , Ciclotrons/instrumentação , Marcação por Isótopo/instrumentação , Geradores de Radionuclídeos/instrumentação , Refrigeração/instrumentação , Íons/síntese química , Íons/isolamento & purificação , Marcação por Isótopo/métodos , Refrigeração/métodos
6.
Rev Sci Instrum ; 86(8): 083308, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26329182

RESUMO

The type of the Electron String Ion Sources (ESIS) is considered to be the appropriate one to produce pulsed C(4+) and C(6+) ion beams for cancer therapy accelerators. In fact, the new test ESIS Krion-6T already now provides more than 10(10) C(4+) ions per pulse and about 5 × 10(9) C(6+) ions per pulse. Such ion sources could be suitable to apply at synchrotrons. It has also been found that Krion-6T can provide more than 10(11) C(6+) ions per second at the 100 Hz repetition rate, and the repetition rate can be increased at the same or larger ion output per second. This makes ESIS applicable at cyclotrons as well. ESIS can be also a suitable type of ion source to produce the (11)C radioactive ion beams. A specialized cryogenic cell was experimentally tested at the Krion-2M ESIS for pulse injection of gaseous species into the electron string. It has been shown in experiments with stable methane that the total conversion efficiency of methane molecules to C(4+) ions reached 5%÷10%. For cancer therapy with simultaneous irradiation and precise dose control (positron emission tomography) by means of (11)C, transporting to the tumor with the primary accelerated (11)C(4+) beam, this efficiency is preliminarily considered to be large enough to produce the (11)C(4+) beam from radioactive methane and to inject this beam into synchrotrons.


Assuntos
Elétrons , Radioterapia com Íons Pesados/instrumentação , Neoplasias/radioterapia , Aceleradores de Partículas/instrumentação , Campos Magnéticos