Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Spine (Phila Pa 1976) ; 22(2): 171-82, 1997 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-9122797

RESUMO

STUDY DESIGN: The authors measured and compared the stiffness of cadaveric lumbar spines stabilized with several anterior interbody fusion devices. The information obtained provides a foundation for determining how methods of anterior lumbar fixation can maximize rigidity and promote development of bony fusion. OBJECTIVES: To compare the utility of three anterior spinal instrumentation systems for stabilizing the lumbar spine. SUMMARY OF BACKGROUND DATA: Anterior spinal instrumentation is used to prevent progressive spinal deformity and maintain correction after spinal fusion surgery. Newer instrumentation systems developed for anterior interbody fusions can be inserted by minimally invasive procedures. The stability of these systems has not been tested adequately in human cadaveric specimens. METHODS: Fusion constructs were evaluated in 12 human cadaveric specimens sequentially loaded in axial compression and torsion, flexion and extension, and lateral bending. The fusion constructs used were 1) two anterior bilateral threaded interbody fusion devices, 2) lateral hollow interbody screws (Texas Scottish Rite Hospital-B screws), and 3) femoral allograft and conventional anterior Texas Scottish Rite Hospital instrumentation. RESULTS: The construct with Texas Scottish Rite Hospital-B screws connected by a rod produced stiffness comparable with that produced by conventional Texas Scottish Rite Hospital instrumentation with femoral ring allografts. The threaded interbody fusion device stiffness tested in axial rotation was comparable with that achieved with Texas Scottish Rite Hospital instrumentation. CONCLUSIONS: Our data demonstrate the effectiveness of threaded interbody fusion device and the Texas Scottish Rite Hospital-B screw in immobilizing the L3-L4 and L4-L5 disc spaces. Rigidity of fixation in the lumbar spine may aid in the maintenance of lordosis.


Assuntos
Parafusos Ósseos , Transplante Ósseo/métodos , Fixadores Internos , Vértebras Lombares/cirurgia , Fusão Vertebral/instrumentação , Absorciometria de Fóton , Adulto , Idoso , Fenômenos Biomecânicos , Feminino , Fêmur , Humanos , Masculino , Pessoa de Meia-Idade , Maleabilidade , Rotação , Fusão Vertebral/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA