1.
J Synchrotron Radiat ; 30(Pt 1): 192-199, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36601937

RESUMO

The investigation of lithium-ion battery failures is a major challenge for personnel and equipment due to the associated hazards (thermal reaction, toxic gases and explosions). To perform such experiments safely, a battery abuse-test chamber has been developed and installed at the microtomography beamline ID19 of the European Synchrotron Radiation Facility (ESRF). The chamber provides the capability to robustly perform in situ abuse tests through the heat-resistant and gas-tight design for flexible battery geometries and configurations, including single-cell and multi-cell assemblies. High-speed X-ray imaging can be complemented by supplementary equipment, including additional probes (voltage, pressure and temperature) and thermal imaging. Together with the test chamber, a synchronization graphical user interface was developed, which allows an initial interpretation by time-synchronous visualization of the acquired data. Enabled by this setup, new meaningful insights can be gained into the internal processes of a thermal runaway of current and future energy-storage devices such as lithium-ion cells.

2.
J Physiol ; 599(22): 5121-5132, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34647325

RESUMO

Ventilation is inhomogeneous in the lungs across species. It has been hypothesized that ventilation inhomogeneity is largely determined by the design of the airway branching network. Because exchange of gases at the alveolar barrier is more efficient when gas concentrations are evenly distributed at subacinar length scales, it is assumed that a 'functional unit' of ventilation exists within the lung periphery, where gas concentration becomes uniform. On the other hand, because the morphology of pulmonary airways and alveoli, and the distribution of inhaled fluorescent particles show self-similar fractal properties over a wide range of length scales, it has been predicted that fractal dimension of ventilation approaches unity within an internally homogeneous functional unit of ventilation. However, the existence of such a functional unit has never been demonstrated experimentally due to lack of in situ gas concentration measurements of sufficient spatial resolution in the periphery of a complex bifurcating network. Here, using energy-subtractive synchrotron radiation tomography, we measured the distribution of an inert gas (Xe) in the in vivo rabbit lung during Xe wash-in breathing manoeuvres. The effects of convective flow rate, diffusion and cardiac motion were also assessed. Fractal analysis of resulting gas concentration and tissue density maps revealed that fractal dimension was always smaller for Xe than for tissue density, and that only for the gas, a length scale existed where fractal dimension approached unity. The length scale where this occurred was seen to correspond to that of a rabbit acinus, the terminal structure comprising only alveolated airways. KEY POINTS: Gas ventilation is inhomogeneous in the lung of many species. However, it is not known down to what length scales this inhomogeneity persists. It is generally assumed that ventilation becomes homogeneous at subacinar length scales, beyond the spatial resolution of commonly available imaging techniques, hence this has not been demonstrated experimentally. Here we measured the distribution of inhaled Xe gas in the rabbit lung using synchrotron radiation energy-subtractive imaging and used fractal analysis to show that ventilation becomes internally uniform within regions about the size of rabbit lung acini.


Assuntos
Fractais , Pulmão , Animais , Difusão , Pulmão/diagnóstico por imagem , Alvéolos Pulmonares , Coelhos , Respiração
3.
Crit Care Med ; 47(9): e774-e781, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31162202

RESUMO

OBJECTIVES: Airway closure is involved in adverse effects of mechanical ventilation under both general anesthesia and in acute respiratory distress syndrome patients. However, direct evidence and characterization of individual airway closure is lacking. Here, we studied the same individual peripheral airways in intact lungs of anesthetized and mechanically ventilated rabbits, at baseline and following lung injury, using high-resolution synchrotron phase-contrast CT. DESIGN: Laboratory animal investigation. SETTING: European synchrotron radiation facility. SUBJECTS: Six New-Zealand White rabbits. INTERVENTIONS: The animals were anesthetized, paralyzed, and mechanically ventilated in pressure-controlled mode (tidal volume, 6 mL/kg; respiratory rate, 40; FIO2, 0.6; inspiratory:expiratory, 1:2; and positive end-expiratory pressure, 3 cm H2O) at baseline. Imaging was performed with a 47.5 × 47.5 × 47.5 µm voxel size, at positive end-expiratory pressure 12, 9, 6, 3, and 0 cm H2O. The imaging sequence was repeated after lung injury induced by whole-lung lavage and injurious ventilation in four rabbits. Cross-sections of the same individual airways were measured. MEASUREMENTS AND MAIN RESULTS: The airways were measured at baseline (n = 48; radius, 1.7 to 0.21 mm) and after injury (n = 32). Closure was observed at 0 cm H2O in three of 48 airways (6.3%; radius, 0.35 ± 0.08 mm at positive end-expiratory pressure 12) at baseline and five of 32 (15.6%; radius, 0.28 ± 0.09 mm) airways after injury. Cross-section was significantly reduced at 3 and 0 cm H2O, after injury, with a significant relation between the relative change in cross-section and airway radius at 12 cm H2O in injured, but not in normal lung (R = 0.60; p < 0.001). CONCLUSIONS: Airway collapsibility increases in the injured lung with a significant dependence on airway caliber. We identify "compliant collapse" as the main mechanism of airway closure in initially patent airways, which can occur at more than one site in individual airways.


Assuntos
Obstrução das Vias Respiratórias/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Respiração Artificial/efeitos adversos , Animais , Coelhos , Tomografia Computadorizada por Raios X
4.
Am J Respir Cell Mol Biol ; 57(4): 459-467, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28535074

RESUMO

Despite the importance of dynamic changes in the regional distributions of gas and blood during the breathing cycle for lung function in the mechanically ventilated patient, no quantitative data on such cyclic changes are currently available. We used a novel gated synchrotron computed tomography imaging to quantitatively image regional lung gas volume (Vg), tissue density, and blood volume (Vb) in six anesthetized, paralyzed, and mechanically ventilated rabbits with normal lungs. Images were repeatedly collected during ventilation and steady-state inhalation of 50% xenon, or iodine infusion. Data were acquired in a dependent and nondependent image level, at zero end-expiratory pressure (ZEEP) and 9 cm H2O (positive end-expiratory pressure), and a tidal volume (Vt) of 6 ml/kg (Vt1) or 9 ml/kg (Vt2) at an Inspiratory:Expiratory ratio of 0.5 or 1.7 by applying an end-inspiratory pause. A video showing dynamic decreases in Vb during inspiration is presented. Vb decreased with positive end-expiratory pressure (P = 0.006; P = 0.036 versus Vt1-ZEEP and Vt2-ZEEP, respectively), and showed larger oscillations at the dependent image level, whereas a 45% increase in Vt did not have a significant effect. End-inspiratory Vb minima were reduced by an end-inspiratory pause (P = 0.042, P = 0.006 at nondependent and dependent levels, respectively). Normalized regional Vg:Vb ratio increased upon inspiration. Our data demonstrate, for the first time, within-tidal cyclic variations in regional pulmonary Vb. The quantitative matching of regional Vg and Vb improved upon inspiration under ZEEP. Further study is underway to determine whether these phenomena affect intratidal gas exchange.


Assuntos
Volume Sanguíneo , Interpretação de Imagem Assistida por Computador , Inalação , Pulmão , Respiração Artificial , Síncrotrons , Ventiladores Mecânicos , Animais , Feminino , Pulmão/irrigação sanguínea , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Masculino , Coelhos
5.
J Synchrotron Radiat ; 24(Pt 6): 1226-1236, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-29091066

RESUMO

The detection system is a key part of any imaging station. Here the performance of the novel sCMOS-based detection system installed at the ID17 biomedical beamline of the European Synchrotron Radiation Facility and dedicated to high-resolution computed-tomography imaging is analysed. The system consists of an X-ray-visible-light converter, a visible-light optics and a PCO.Edge5.5 sCMOS detector. Measurements of the optical characteristics, the linearity of the system, the detection lag, the modulation transfer function, the normalized power spectrum, the detective quantum efficiency and the photon transfer curve are presented and discussed. The study was carried out at two different X-ray energies (35 and 50 keV) using both 2× and 1× optical magnification systems. The final pixel size resulted in 3.1 and 6.2 µm, respectively. The measured characteristic parameters of the PCO.Edge5.5 are in good agreement with the manufacturer specifications. Fast imaging can be achieved using this detection system, but at the price of unavoidable losses in terms of image quality. The way in which the X-ray beam inhomogeneity limited some of the performances of the system is also discussed.

6.
Crit Care Med ; 45(4): 687-694, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28107207

RESUMO

OBJECTIVES: Positive pressure ventilation exposes the lung to mechanical stresses that can exacerbate injury. The exact mechanism of this pathologic process remains elusive. The goal of this study was to describe recruitment/derecruitment at acinar length scales over short-time frames and test the hypothesis that mechanical interdependence between neighboring lung units determines the spatial and temporal distributions of recruitment/derecruitment, using a computational model. DESIGN: Experimental animal study. SETTING: International synchrotron radiation laboratory. SUBJECTS: Four anesthetized rabbits, ventilated in pressure controlled mode. INTERVENTIONS: The lung was consecutively imaged at ~ 1.5-minute intervals using phase-contrast synchrotron imaging, at positive end-expiratory pressures of 12, 9, 6, 3, and 0 cm H2O before and after lavage and mechanical ventilation induced injury. The extent and spatial distribution of recruitment/derecruitment was analyzed by subtracting subsequent images. In a realistic lung structure, we implemented a mechanistic model in which each unit has individual pressures and speeds of opening and closing. Derecruited and recruited lung fractions (Fderecruited, Frecruited) were computed based on the comparison of the aerated volumes at successive time points. MEASUREMENTS AND MAIN RESULTS: Alternative recruitment/derecruitment occurred in neighboring alveoli over short-time scales in all tested positive end-expiratory pressure levels and despite stable pressure controlled mode. The computational model reproduced this behavior only when parenchymal interdependence between neighboring acini was accounted for. Simulations closely mimicked the experimental magnitude of Fderecruited and Frecruited when mechanical interdependence was included, while its exclusion gave Frecruited values of zero at positive end-expiratory pressure greater than or equal to 3 cm H2O. CONCLUSIONS: These findings give further insight into the microscopic behavior of the injured lung and provide a means of testing protective-ventilation strategies to prevent recruitment/derecruitment and subsequent lung damage.


Assuntos
Lesão Pulmonar Aguda/etiologia , Lesão Pulmonar Aguda/fisiopatologia , Respiração com Pressão Positiva/efeitos adversos , Alvéolos Pulmonares/fisiopatologia , Lesão Pulmonar Aguda/diagnóstico por imagem , Animais , Simulação por Computador , Masculino , Pressão , Alvéolos Pulmonares/diagnóstico por imagem , Coelhos , Síncrotrons
7.
Eur J Anaesthesiol ; 33(10): 767-75, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27533710

RESUMO

BACKGROUND: It is not well understood how different ventilation modes affect the regional distribution of ventilation, particularly within the injured lung. OBJECTIVES: We compared respiratory mechanics, lung aeration and regional specific ventilation ((Equation is included in full-text article.)) distributions in healthy and surfactant-depleted rabbits ventilated with pressure-regulated volume control (PRVC) mode with a decelerating inspiratory flow or with volume control (VC) mode. DESIGN: Randomised experimental study. ANIMALS AND INTERVENTIONS: New Zealand white rabbits (n = 8) were anaesthetised, paralysed and mechanically ventilated either with VC or PRVC mode (tidal volume: 7 ml kg; rate: 40 min; positive end-expiratory pressure (PEEP): 3 cmH2O), at baseline and after lung injury induced by lung lavage. MAIN OUTCOME MEASURES: Airway resistance (Raw), respiratory tissue damping (G) and elastance (H) were measured by low-frequency forced oscillations. Synchrotron radiation computed tomography during stable xenon wash-in was used to measure regional lung aeration and specific ventilation and the relative fraction of nonaerated, trapped, normally, poorly and hyperinflated lung regions. RESULTS: Lung lavage significantly elevated peak inspiratory pressure (PIP) (P < 0.001). PIP was lower on PRVC compared with VC mode (-12.7 ±â€Š1.7%, P < 0.001). No significant differences in respiratory mechanics, regional ventilation distribution, strain or blood oxygenation could be detected between the two ventilation modes. CONCLUSION: A decelerating flow pattern (PRVC) resulted in equivalent regional ventilation distribution, respiratory mechanics and gas exchange, in both normal and mechanically heterogeneous lungs with, however, a significantly lower peak pressure. Our data suggest that the lower PIP on PRVC ventilation was because of the decelerating flow pattern rather than the ventilation distribution.


Assuntos
Lesão Pulmonar Aguda/fisiopatologia , Lesão Pulmonar Aguda/terapia , Pulmão/fisiologia , Respiração Artificial/métodos , Mecânica Respiratória/fisiologia , Volume de Ventilação Pulmonar/fisiologia , Animais , Masculino , Respiração com Pressão Positiva/métodos , Pressão , Coelhos , Distribuição Aleatória
8.
Ultrason Sonochem ; 92: 106286, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36599280

RESUMO

High-power ultrasonic horns operating at low frequency are known to generate a cone-shaped cavitation bubble cloud beneath them. The exact physical processes resulting in the conical structure are still unclear mainly due to challenges associated with their visualization. Herein, we address the onset of the cavitation cloud by exploiting high-speed X-ray phase contrast imaging. It reveals that the cone formation is not immediate but results from a three-step phenomenology: (i) inception and oscillation of single bubbles, (ii) individual cloud formation under splitting or lens effects, and (iii) cloud merging leading to the formation of a bubble layer and, eventually, to the cone structure due to the radial pressure gradient on the horn tip.


Assuntos
Síncrotrons , Ultrassom , Ultrassom/métodos , Raios X
9.
iScience ; 26(11): 108078, 2023 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-37876824

RESUMO

All-solid-state batteries have been developed to increase energy density by replacing the lithiated graphite negative electrode by a lithium metal foil and to increase safety by removing the organic compounds. However, the safety issues of these batteries have received little attention up to now. The behavior of a reassembled all-solid-state battery under thermal stress was recorded by X-ray radiography and a high-speed camera. The thermal runaway (TR) lasted about 5 ms, thus extremely fast reaction kinetics. In comparison, the TR of a lithium-ion battery is about 500 ms. Furthermore, a 188-mbar aerial overpressure was measured using a piezoelectric sensor. Although this cell is not an explosive, 2.7 g TNT equivalent was calculated for it. This atypical behavior could have an impact on the casing or the battery pack. Therefore, it must be studied in greater detail.

10.
PLoS One ; 17(8): e0273315, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36037163

RESUMO

X-ray directional dark-field imaging is a recent technique that can reveal a sample's small-scale structural properties which are otherwise invisible in a conventional imaging system. In particular, directional dark-field can detect and quantify the orientation of anisotropic structures. Here, we present an algorithm that allows for the extraction of a directional dark-field signal from X-ray speckle-based imaging data. The experimental setup is simple, as it requires only the addition of a diffuser to a full-field microscope setup. Sandpaper is an appropriate diffuser material in the hard x-ray regime. We propose an approach to extract the mean scattering width, directionality, and orientation from the recorded speckle images acquired with the technique. We demonstrate that our method can detect and quantify the orientation of fibres inside a carbon fibre reinforced polymer (CFRP) sample within one degree of accuracy and show how the accuracy depends on the number of included measurements. We show that the reconstruction parameters can be tuned to increase or decrease accuracy at the expense of spatial resolution.


Assuntos
Algoritmos , Radiografia , Raios X , Anisotropia , Radiografia/métodos
11.
Osteoarthr Cartil Open ; 3(2): 100168, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36474982

RESUMO

Objective: X-ray Phase Contrast Imaging (PCI) is an emerging modality that will be in the next few years available in a wider range of preclinical set-ups. In this study, we compare this imaging technique with conventional preclinical modalities in an osteoarthritis mouse model. Method: Phase contrast technique was performed on 6 post-mortem, monoiodoacetate-induced osteoarthritis knees and 6 control knees. The mice knees were then imaged using magnetic resonance imaging and conventional micro computed tomography. Examples of imaging surrogate markers are reported: local distances within the articular space, cartilage surface roughness, calcified cartilage thickness, number, volume and locations of osteophytes. Results: Thanks to PCI, we can show in 3D calcified cartilage without contrast agent by a non-invasive technique. The phase contrast images reveal more details than conventional imaging techniques, especially at smaller scales, with for instance a higher number of micro-calcifications detected (57, 314 and 329 for MRI, conventional micro-CT and phase contrast imaging respectively). Calcified cartilage thickness was measured with a significant difference (p â€‹< â€‹0.01) between the control (23.4 â€‹± â€‹17.2 â€‹µm) and the osteoarthritis induced animal (46.9 â€‹± â€‹19.0 â€‹µm). Conclusions: X-ray phase contrast imaging outperforms the conventional imaging modalities for assessing the different tissue types (soft and hard). This new imaging modality seems to bring new relevant surrogate markers for following-up small animal models even for low-grade osteoarthritis.

12.
Front Physiol ; 12: 683316, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34177626

RESUMO

BACKGROUND: Nasal high flow (NHF) is a non-invasive breathing therapy that is based on the delivery via a large-caliber nasal cannula of heated and humidified air at flow rates that exceed peak inspiratory flow. It is thought that positive airway pressure generated by NHF can help reduce gas trapping and improve regional lung ventilation. There are no data to confirm this hypothesis at flow rates applicable in stable chronic obstructive pulmonary disease (COPD) patients. METHODS: In this study, we used non-rigid registration of computed tomography (CT) images acquired at maximal expiration and inspiration to compute regional lung attenuation changes (ΔHU), and lung displacement (LD), indices of regional lung ventilation. Parametric response maps (Galban et al., 2012) were also computed in each experimental condition. Eight COPD patients were assessed at baseline (BL) and after 5 min of NHF and expiratory resistive loading (ERL). RESULTS: ΔHU was: BL (median, IQR): 85 (67.2, 102.8); NHF: 90.7 (57.4, 97.6); ERL: 74.6 (46.4, 89.6) HU (p = 0.531); and LD: 27.8 (22.3, 39.3); 17.6 (15.4, 27.9); and 20.4 (16.6, 23.6) mm (p = 0.120) in the 3 conditions, respectively. No significant difference in trapping was observed. Respiratory rate significantly decreased with both treatments [BL: 17.3 (16.4, 18.9); NHF: 13.7; ERL: 11.4 (9.6, 13.2) bpm; and p < 0.001]. CONCLUSION: Neither NHF at 25 L/min nor ERL significantly improved the regional lung ventilation of stable COPD patients with gas trapping, based on functional lung CT imaging. Further study including more subjects is needed to assess the potential effect of NHF on regional lung function at higher flow rates. CLINICAL TRIAL REGISTRATION: www.clinicaltrials.gov/under, identifier NCT03821311.

13.
Sci Rep ; 11(1): 4236, 2021 02 19.
Artigo em Inglês | MEDLINE | ID: mdl-33608569

RESUMO

Mechanical ventilation can damage the lungs, a condition called Ventilator-Induced Lung Injury (VILI). However, the mechanisms leading to VILI at the microscopic scale remain poorly understood. Here we investigated the within-tidal dynamics of cyclic recruitment/derecruitment (R/D) using synchrotron radiation phase-contrast imaging (PCI), and the relation between R/D and cell infiltration, in a model of Acute Respiratory Distress Syndrome in 6 anaesthetized and mechanically ventilated New-Zealand White rabbits. Dynamic PCI was performed at 22.6 µm voxel size, under protective mechanical ventilation [tidal volume: 6 ml/kg; positive end-expiratory pressure (PEEP): 5 cmH2O]. Videos and quantitative maps of within-tidal R/D showed that injury propagated outwards from non-aerated regions towards adjacent regions where cyclic R/D was present. R/D of peripheral airspaces was both pressure and time-dependent, occurring throughout the respiratory cycle with significant scatter of opening/closing pressures. There was a significant association between R/D and regional lung cellular infiltration (p = 0.04) suggesting that tidal R/D of the lung parenchyma may contribute to regional lung inflammation or capillary-alveolar barrier dysfunction and to the progression of lung injury. PEEP may not fully mitigate this phenomenon even at high levels. Ventilation strategies utilizing the time-dependence of R/D may be helpful in reducing R/D and associated injury.


Assuntos
Microscopia/métodos , Lesão Pulmonar Induzida por Ventilação Mecânica/diagnóstico por imagem , Lesão Pulmonar Induzida por Ventilação Mecânica/patologia , Raios X , Animais , Biomarcadores , Análise de Dados , Modelos Animais de Doenças , Progressão da Doença , Respiração com Pressão Positiva , Coelhos , Respiração Artificial/efeitos adversos , Síndrome do Desconforto Respiratório/etiologia , Síndrome do Desconforto Respiratório/patologia , Tomografia Computadorizada por Raios X , Lesão Pulmonar Induzida por Ventilação Mecânica/etiologia , Lesão Pulmonar Induzida por Ventilação Mecânica/fisiopatologia
14.
J Clin Med ; 8(8)2019 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-31357677

RESUMO

Modern ventilatory strategies are based on the assumption that lung terminal airspaces act as isotropic balloons that progressively accommodate gas. Phase contrast synchrotron radiation computed tomography (PCSRCT) has recently challenged this concept, showing that in healthy lungs, deflation mechanisms are based on the sequential de-recruitment of airspaces. Using PCSRCT scans in an animal model of acute respiratory distress syndrome (ARDS), this study examined whether the numerosity (ASnum) and dimension (ASdim) of lung airspaces change during a deflation maneuver at decreasing levels of positive end-expiratory pressure (PEEP) at 12, 9, 6, 3, and 0 cmH2O. Deflation was associated with significant reduction of ASdim both in the whole lung section (passing from from 13.1 ± 2.0 at PEEP 12 to 7.6 ± 4.2 voxels at PEEP 0) and in single concentric regions of interest (ROIs). However, the regression between applied PEEP and ASnum was significant in the whole slice (ranging from 188 ± 52 at PEEP 12 to 146.4 ± 96.7 at PEEP 0) but not in the single ROIs. This mechanism of deflation in which reduction of ASdim is predominant, differs from the one observed in healthy conditions, suggesting that the peculiar alveolar micromechanics of ARDS might play a role in the deflation process.

15.
Front Physiol ; 10: 719, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31231245

RESUMO

INTRODUCTION: The mechanisms of lung inflation and deflation are only partially known. Ventilatory strategies to support lung function rely upon the idea that lung alveoli are isotropic balloons that progressively inflate or deflate and that lung pressure/volume curves derive only by the interplay of critical opening pressures, critical closing pressures, lung history, and position of alveoli inside the lung. This notion has been recently challenged by subpleural microscopy, magnetic resonance, and computed tomography (CT). Phase-contrast synchrotron radiation CT (PC-SRCT) can yield in vivo images at resolutions higher than conventional CT. OBJECTIVES: We aimed to assess the numerosity (ASden) and the extension of the surface of airspaces (ASext) in healthy conditions at different volumes, during stepwise lung deflation, in concentric regions of the lung. METHODS: The study was conducted in seven anesthetized New Zealand rabbits. They underwent PC-SRCT scans (resolution of 47.7 µm) of the lung at five decreasing positive end expiratory pressure (PEEP) levels of 12, 9, 6, 3, and 0 cmH2O during end-expiratory holds. Three concentric regions of interest (ROIs) of the lung were studied: subpleural, mantellar, and core. The images were enhanced by phase contrast algorithms. ASden and ASext were computed by using the Image Processing Toolbox for MatLab. Statistical tests were used to assess any significant difference determined by PEEP or ROI on ASden and ASext. RESULTS: When reducing PEEP, in each ROI the ASden significantly decreased. Conversely, ASext variation was not significant except for the core ROI. In the latter, the angular coefficient of the regression line was significantly low. CONCLUSION: The main mechanism behind the decrease in lung volume at PEEP reduction is derecruitment. In our study involving lung regions laying on isogravitational planes and thus equally influenced by gravitational forces, airspace numerosity and extension of surface depend on the local mechanical properties of the lung.

16.
J Appl Physiol (1985) ; 119(3): 290-8, 2015 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-25997942

RESUMO

We assessed the changes in regional lung function following instillation of surfactant in a model of respiratory distress syndrome (RDS) induced by whole lung lavage and mechanical ventilation in eight anaesthetized, paralyzed, and mechanically ventilated New Zealand White rabbits. Regional specific ventilation (sV̇) was measured by K-edge subtraction synchrotron computed tomography during xenon washin. Lung regions were classified as poorly aerated (PA), normally aerated (NA), or hyperinflated (HI) based on regional density. A functional category was defined within each class based on sV̇ distribution (High, Normal, and Low). Airway resistance (Raw), respiratory tissue damping (G), and elastance (H) were measured by forced oscillation technique at low frequencies before and after whole lung saline lavage-induced (100 ml/kg) RDS, and 5 and 45 min after intratracheal instillation of beractant (75 mg/kg). Surfactant instillation improved Raw, G, and H (P < 0.05 each), and gas exchange and decreased atelectasis (P < 0.001). It also significantly improved lung aeration and ventilation in atelectatic lung regions. However, in regions that had remained normally aerated after lavage, it decreased regional aeration and increased sV̇ (P < 0.001) and sV̇ heterogeneity. Although surfactant treatment improved both central airway and tissue mechanics and improved regional lung function of initially poorly aerated and atelectatic lung, it deteriorated regional lung function when local aeration was normal prior to administration. Local mechanical and functional heterogeneity can potentially contribute to the worsening of RDS and gas exchange. These data underscore the need for reassessing the benefits of routine prophylactic vs. continuous positive airway pressure and early "rescue" surfactant therapy in very immature infants.


Assuntos
Produtos Biológicos/administração & dosagem , Modelos Animais de Doenças , Pulmão/fisiopatologia , Troca Gasosa Pulmonar/efeitos dos fármacos , Síndrome do Desconforto Respiratório/fisiopatologia , Mecânica Respiratória/efeitos dos fármacos , Resistência das Vias Respiratórias/efeitos dos fármacos , Animais , Instilação de Medicamentos , Pulmão/efeitos dos fármacos , Masculino , Surfactantes Pulmonares , Coelhos , Síndrome do Desconforto Respiratório/tratamento farmacológico , Irrigação Terapêutica , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS