RESUMO
INTRODUCTION: High-pitch CT angiography (CTA) is a recent innovation that allows significant shortening of scan time with volume coverage of 43 mm per second. The aim of our study was to assess this technique in CTA of the head and neck. METHODS: CTA of supra-aortic arteries was performed in 50 patients using two acquisition protocols: conventional single-source 64-slice (pitch 1.2) and high-pitch dual-source 128-slice CT (pitch 3.2). Subjective and objective image quality of supra-aortic vessel ostia as well as intra- and extra-cranial segments was retrospectively assessed by blinded readers and radiation dose compared between the two protocols. RESULTS: Conventional and high-pitch CTA achieved comparable signal-to-noise ratios in arterial (54.3 ± 16.5 versus 57.3 ± 14.8; p = 0.50) and venous segments (15.8 ± 6.7 versus 18.9 ± 8.9; p = 0.21). High-pitch scanning was, however, associated with sharper delineation of vessel contours and image quality significantly improved at the level of supra-aortic vessel ostia (p < 0.0001) as well as along the brachiocephalic trunk (p < 0.0001), the subclavian arteries (p < 0.0001), proximal common carotid arteries (p = 0.01), and vertebral V1 segments (p < 0.0001). Using the high-pitch mode, the dose-length product was reduced by about 35% (218.2 ± 30 versus 141.8 ± 20 mGy × cm). CONCLUSIONS: Due to elimination of transmitted cardiac motion, high-pitch CTA of the neck improves image quality in the proximity of the aortic arch while significantly lowering radiation dose. The technique thus qualifies as a promising alternative to conventional spiral CTA and may be particularly useful for identification of ostial stenosis.
Assuntos
Angiografia/métodos , Aorta Torácica/diagnóstico por imagem , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Algoritmos , Carga Corporal (Radioterapia) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e EspecificidadeRESUMO
OBJECTIVE: To assess parenchymal bolus-triggering in terms of liver enhancement, lesion-to-liver conspicuity and inter-image variability across serial follow-up MDCTs. METHODS: We reviewed MDCTs of 50 patients with hepatic metastases who had a baseline CT and two follow-up examinations. In 25 consecutive patients CT data acquisition was initiated by liver parenchyma triggering at a 50-HU enhancement threshold. In a matched control group, imaging was performed with an empirical delay of 65 s. CT attenuation values were assessed in vessels, liver parenchyma and metastasis. Target lesions were classified according to five enhancement patterns. RESULTS: Compared with the control group, liver enhancement was significantly higher with parenchyma triggering (59.8 ± 7.6 HU vs. 48.8 ± 11.2 HU, P = 0.0002). The same was true for conspicuity (liver parenchyma - lesion attenuation) of hypo-enhancing lesions (72.2 ± 15.9 HU vs. 52.7 ± 19.4 HU, P = 0.0006). Liver triggering was associated with reduced variability for liver enhancement among different patients (P = 0.035) and across serial follow-up examinations in individual patients (P < 0.0001). The number of patients presenting with uniform lesion enhancement pattern across serial examinations was significantly higher in the triggered group (20 vs. 11; P = 0.018). CONCLUSION: Liver parenchyma triggering provides superior lesion conspicuity and improves standardisation of image quality across follow-up examinations with greater uniformity of enhancement patterns. KEY POINTS: Liver parenchyma tracking improves liver enhancement and lesion-to-liver conspicuity in abdominal CT. In serial CT studies this technique reduces variability of conspicuity and enhancement patterns. Higher liver-to-lesion conspicuity is a prerequisite for reliable detection of liver lesions. Stabilisation of enhancement permits more accurate follow-up of oncology patients.
Assuntos
Algoritmos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Fígado/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/normas , Estados UnidosRESUMO
The efficiency and radiation dose of a low-dose dual-energy (DE) CT protocol for the evaluation of urinary calculus disease were evaluated. A low-dose dual-source DE-CT renal calculi protocol (140 kV, 46 mAs; 80 kV, 210 mAs) was derived from the single-energy (SE) CT protocol used in our institution for the detection of renal calculi (120 kV, 75 mAs). An Alderson-Rando phantom was equipped with thermoluminescence dosimeters and examined by CT with both protocols. The effective doses were calculated. Fifty-one patients with suspected or known urinary calculus disease underwent DE-CT. DE analysis was performed if calculi were detected using a dedicated software tool. Results were compared to chemical analysis after invasive calculus extraction. An effective dose of 3.43 mSv (male) and 5.30 mSv (female) was measured in the phantom for the DE protocol (vs. 3.17/4.57 mSv for the SE protocol). Urinary calculi were found in 34 patients; in 28 patients, calculi were removed and analyzed (23 patients with calcified calculi, three with uric acid calculi, one with 2,8-dihyxdroxyadenine-calculi, one patient with a mixed struvite calculus). DE analysis was able to distinguish between calcified and non-calcified calculi in all cases. In conclusion, dual-energy urinary calculus analysis is effective also with a low-dose protocol. The protocol tested in this study reliably identified calcified urinary calculi in vivo.
Assuntos
Absorciometria de Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Cálculos Urinários/diagnóstico por imagem , Feminino , Humanos , Masculino , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e EspecificidadeRESUMO
Multislice computed tomography is an emerging diagnostic modality in cardiology practice. Within the last decade a rapid technical evolution from 4-slice scanners to 64-slice and meanwhile 320-slice scanners which faster gantry rotation time has taken place. These advances as well as improved post-processing tools account for a stabilization of image quality and allow assessing cardiac structures with high spatial and temporal resolution. Moreover, dedicated acquisition techniques have been employed to reduce radiation exposure to a minimum. Today cardiac computed tomography is not only able to depict the coronary arteries, but to get reliable information about cardiac function and cardiac structure. This review focuses on present clinical indications and future application of multi-slice computed tomography in clinical cardiology.
Assuntos
Angiografia Coronária/métodos , Cardiopatias/diagnóstico por imagem , Coração/diagnóstico por imagem , Tomografia Computadorizada Espiral/métodos , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Ponte de Artéria Coronária , Estenose Coronária/diagnóstico por imagem , Diagnóstico Diferencial , Eletrocardiografia , Previsões , Frequência Cardíaca , Doenças das Valvas Cardíacas/diagnóstico por imagem , Humanos , Tomografia Computadorizada Espiral/normas , Função Ventricular EsquerdaRESUMO
To assess HU-based color mapping for characterization of coronary plaque, using intravascular ultrasound virtual histology (IVUS-VH) as a standard of reference. Dual-source computed tomography and IVUS-VH were prospectively performed in 13 patients. In five lesions, HU thresholds of the color-coding software were calibrated to IVUS-VH. In a 15-lesion verification cohort, volumes of vessel, lumen and plaque or percentages of lipid, fibrous and calcified components were obtained through use of pre-set HU cut-offs as well as through purely visual adjustment of color maps. Calibrated HU ranges for fatty or fibrous plaque, lumen and calcification were -10-69, 70-158, 159-436 and 437+. Using these cut-offs, HU-based analysis achieved good agreement of plaque volume with IVUS (47.0 vs. 51.0 mm(3)). Visual segmentation led to significant overestimation of atheroma (61.6 vs. 51.0 mm(3); P = 0.04) Correlation coefficients for volumes of vessel, lumen and plaque were 0.92, 0.87 and 0.83 with HU-based analysis or 0.92, 0.85 and 0.71 with visual evaluation. With both methods, correlation of percentage plaque composition was poor or insignificant. HU-based plaque analysis showed good reproducibility with intra-class correlation coefficients being 0.90 for plaque volume and 0.81, 0.94 or 0.98 for percentages of fatty, fibrous or calcified components. With use of optimized HU thresholds, color mapping allows for accurate and reproducible quantification of coronary plaque.
Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Ecocardiografia Doppler em Cores/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Masculino , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e EspecificidadeRESUMO
OBJECTIVE: The aim of this study was to assess the impact of heart rate, heart rate variability and calcification on image quality and diagnostic accuracy in an unselected patient collective. SUBJECTS AND METHODS: One hundred and two consecutive patients with known or suspected coronary artery disease underwent both 64-MSCT and invasive coronary angiography. Image quality (IQ) was assessed by independent observers using a 4-point scale from excellent (1) to non-diagnostic (4). Accuracy of MSCT regarding detection or exclusion of significant stenosis (>50%) was evaluated on a per segment basis in a modified AHA 13-segment model. Effects of heart rate, heart rate variability, calcification and body mass index (BMI) on IQ and accuracy were evaluated by multivariate regression. IQ and accuracy were further analysed in subgroups of significant predictor variables and simple regression performed to calculate thresholds for adequate IQ. RESULTS: Mean heart rate was 68.2+/-13.3 bpm, mean heart rate variability 11.5+/-16.0 beats per CT-examination (bpct) and median Agatston score 226.5. Average IQ score was 2+/-0.6 whilst diagnostic quality was obtained in 89% of segments. Overall sensitivity, specificity, PPV or NPV was 91.2%, 99.2%, 95.3% or 98.3%. According to multivariate regression, overall IQ was significantly related to heart rate and calcification (P=0.0038; P<0.0001). The effect of heart rate variability was limited to IQ of RCA segments (P=0.018); BMI was not related to IQ (P=0.52). Calcification was the only predictor variable with significant effect on the number of non-diagnostic segments (P<0.0001). In a multivariate regression, calcification was also the single factor with impact on diagnostic accuracy (P=0.0049). CONCLUSION: Whilst heart rate, heart rate variability and calcification all show an inverse correlation to IQ, severe calcium burden remains the single factor with translation of such effect into decrease of diagnostic accuracy.
Assuntos
Calcinose/diagnóstico por imagem , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Tomografia Computadorizada Espiral , Índice de Massa Corporal , Distribuição de Qui-Quadrado , Meios de Contraste , Feminino , Frequência Cardíaca/fisiologia , Humanos , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Análise de Regressão , Estatísticas não ParamétricasRESUMO
OBJECTIVE: The aim of this study was to assess the accuracy of MSCT in characterizing myocardial infarction (MI) and, thereby, determine the extent of early perfusion defect (ED), microvascular obstruction (MO) and transmural depth of late enhancement (LE) in comparison to MRI and histology. MATERIALS AND METHODS: Seven pigs were studied with MSCT (Somatom Sensation 64) and MRI (Magnetom Sonata) a median 1 and 21 days following temporary occlusion of a diagonal branch and creation of small reperfused infarction. For depiction of ED, CT images were acquired in the early arterial phase and following 35 s; LE and MO were evaluated on images obtained at 3, 5, 10 and 15 min. Thereby, a bolus/low-flow contrast injection protocol was used. Triphenyltetrazolium-chloride (TTC) stain and histology were obtained. Volumes of enhancement patterns were assessed as percentage of the ventricle and compared by Bland-Altman analysis. Segmental co-localization and graded transmurality was evaluated with weighted-kappa-test. RESULTS: Close spatial agreement was observed for MRI-MO and MSCT-MO (bias=0.55; CI=-1.49 to 2.60 at 5 min MSCT), TTC and MSCT-LE (bias=-1.28; CI=-3.76 to 1.19) or MRI-LE and MSCT-LE (bias=-0.79; CI=-4.19 to 2.60). There was good segmental co-localization for MO (weighted kappa=0.93) and high agreement for transmural extent of TTC, MRI-LE and MSCT-LE (weighted kappa=0.84 TTC versus MSCT; 0.86 MRI versus MSCT). Arterial and 35s ED significantly underestimated infarct size and showed poor segmental or transmural agreement (weighted kappa=0.33; 0.44). CONCLUSIONS: MSCT late-scans not only reliably depict size of MO and LE in acute or subacute infarct phases but, moreover, allow for accurate determination of LE transmurality.
Assuntos
Imageamento por Ressonância Magnética , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/patologia , Tomografia Computadorizada por Raios X , Análise de Variância , Animais , Corantes , Meios de Contraste , Modelos Animais de Doenças , Gadolínio DTPA , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Aumento da Imagem , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Projetos de Pesquisa , Sensibilidade e Especificidade , Suínos , Sais de TetrazólioRESUMO
Aim of this study was to compare low tube voltage computed tomography (80 kV) of the liver using iterative image reconstruction (SAFIRE) with standard computed tomography (120 kV) using filtered back-projection (FBP) for the detection of hepatocellular carcinoma (HCC). 46 patients (43 men) with 93 HCC confirmed by 3 T MRI with Gd-EOB-DPTA, in inconclusive cases combined with contrast-enhanced ultrasound, underwent dual-energy CT. The raw data of the 80 kV tube was reconstructed using the iterative reconstruction algorithm SAFIRE with two strengths (I3 and I5). The virtual 120 kV image data set was reconstructed using FBP. The CT images were reviewed to determine the lesion-to-liver contrast (LLC), the lesion contrast-to-noise ratio (CNR) and the sensitivity. The LLC (57.1/54.3 [I3/I5] vs. 34.9 [FBP]; p ≤ 0.01), CNR (3.67/4.45 [I3/I5] vs. 2.48 [FBP]; p < 0.01) and sensitivity (91.4%/88.2% [I3/I5] vs. 72.0% [FBP]; p ≤ 0.01) were significantly higher in the low-voltage protocol using SAFIRE. Therefore, low tube voltage CT using SAFIRE results in an increased lesion-to-liver contrast as well as an improved lesion contrast-to-noise ratio compared to FBP at 120 kV which results in a higher sensitivity for the detection of HCC.
Assuntos
Carcinoma Hepatocelular/diagnóstico , Neoplasias Hepáticas/diagnóstico , Fígado/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Fígado/patologia , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Estudos Prospectivos , Doses de Radiação , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X , UltrassonografiaRESUMO
PURPOSE: We investigated the agreement of dual-energy computed tomography angiography (DE-CTA) and contrast-enhanced magnetic resonance angiography (CE-MRA)in the quantitative measurement of stenoses of the internal carotid artery in comparison with digital subtraction angiography (DSA). METHODS: A total of 21 patients with stenoses of the external carotid artery were investigated with a DE-CTA and CE-MRA before undergoing carotid angioplasty. The grade of the stenoses was assessed in axial multiplanar reformations (MPR) before and multi-intensity projections (MIP) after plaque subtraction (PS) and compared with results from CE-MRA and DSA according to the North American Symptomatic Carotid Endarterectomy Trial. RESULTS: Average grades of stenoses were 80.7 ± 16.1 % (DSA), 81.4 ± 15.3 % (MRA), 80.0 ± 16.7 % (DE-CTA-MPR), and 85.2 ± 14.7 % (DE-CTA-PS-MIP). Of 21 stenoses, 6 were filiform (stenosis grade, 99 %) in the DSA examination. Five of these cases were identified as pseudo-occlusions in MRA, while four were considered as occlusions in DE-CTA-PS-MIP. Another four cases were identified as pseudo-occlusion in DE-CTA-PS-MIP, which were identified as 90 % stenosis in the DSA examination. CONCLUSIONS: In comparison with the gold standard DSA, DE-CTA-MPR had a slightly better agreement in measuring the degree of stenosis of the internal carotid arteries than CE-MRA. In DE-CTA-PS-MIP images, a systematic overestimation has to be taken into account due to partial extinction of the lumen by the PS algorithm. Nevertheless, DE-CTA should be preferred in imaging patients with carotid artery stenosis in the presence of extensive calcifications.
Assuntos
Calcinose/diagnóstico , Estenose das Carótidas/diagnóstico , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Calcinose/complicações , Estenose das Carótidas/complicações , Meios de Contraste , Feminino , Humanos , Masculino , Meglumina/análogos & derivados , Pessoa de Meia-Idade , Compostos Organometálicos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Índice de Gravidade de DoençaRESUMO
OBJECTIVE: With further increase of CT numbers and their dominant contribution to medical exposure, there is a recent quest for more effective dose control. While reintroduction of iterative reconstruction (IR) has proved its potential in many applications, a novel focus is placed on more noise efficient detectors. Our purpose was to assess the potential of IR in combination with an integrated circuit detector (ICD) for aggressive dose reduction in head CT. METHODS: Non-contrast low-dose head CT [190 mAs; weighted volume CT dose index (CTDIvol), 33.2 mGy] was performed in 50 consecutive patients, using a new noise efficient detector and IR. Images were assessed in terms of quantitative and qualitative image quality and compared with standard dose acquisitions (320 mAs; CTDIvol, 59.7 mGy) using a conventional detector and filtered back projection. RESULTS: By combining ICD and IR in low-dose examinations, the signal to noise was improved by about 13% above the baseline level in the standard-dose control group. Both, contrast-to-noise ratio (2.02 ± 0.6 vs 1.88 ± 0.4; p = 0.18) and objective measurements of image sharpness (695 ± 84 vs 705 ± 151 change in Hounsfield units per pixel; p = 0.79) were fully preserved in the low-dose group. Likewise, there was no significant difference in the grading of several subjective image quality parameters when both noise-reducing strategies were used in low-dose examinations. CONCLUSION: Combination of noise efficient detector with IR allows for meaningful dose reduction in head CT without compromise of standard image quality. ADVANCES IN KNOWLEDGE: Our study demonstrates the feasibility of almost 50% dose reduction in head CT dose (1.1 mSv per scan) through combination of novel dose-reducing strategies.
Assuntos
Cabeça/diagnóstico por imagem , Doses de Radiação , Proteção Radiológica/instrumentação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Razão Sinal-RuídoRESUMO
PURPOSE: Iterative reconstruction has recently been revisited as a promising concept for substantial CT dose reduction. The purpose of this study was to assess the potential benefit of sinogram affirmed iterative reconstruction (SAFIRE) in head CT by comparing objective and subjective image quality at reduced tube current with standard dose filtered back projection (FBP). MATERIALS AND METHODS: Non-contrast reduced dose head CT (255 mAs, CTDIvol 47.8 mGy) was performed in thirty consecutive patients and reconstructed with SAFIRE and FBP. Images were assessed in terms of quantitative and qualitative image quality and compared with FBP of standard dose acquisitions (320 mAs, CTDI vol 59.7 mGy). RESULTS: In reduced dose CT examinations, use of SAFIRE versus FBP resulted in 47% increase in contrast-to-noise ratio (CNR) (2.49 vs. 1.69; p<0.0001). While reduction of tube current was associated with 13% decrease in CNR, quantitative degradation of image quality at lower dose was more than compensated through SAFIRE (2.49 vs. 1.96; p=0.0004). Objective measurements of image sharpness were comparable between FBP and SAFIRE reconstructions (575.9 ± 74.1 vs. 583.4 ± 74.7 change in HU/Pixel; p=0.28). Compared to standard dose FBP, subjective grading of noise as well as overall image quality scores were significantly improved when SAFIRE was used in reduced dose exams (1.3 vs. 1.6, p=0.006; 1.3 vs. 1.7, p=0.026). CONCLUSION: At 20% dose reduction, reconstruction of head CT by SAFIRE provides above standard objective and subjective image quality, suggesting potential for more vigorous dose savings in neuroradiology CT applications.
Assuntos
Algoritmos , Encefalopatias/diagnóstico , Traumatismos Craniocerebrais/diagnóstico por imagem , Doses de Radiação , Proteção Radiológica/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios XRESUMO
OBJECTIVE: To identify the high-resolution CT (HRCT) patterns of Herpes-Simplex-Virus 1 (HSV) pneumonia in immunocompromised patients and correlate findings to outcome and radiographic follow-up until death or complete resolution of findings. PATIENTS AND METHODS: HRCT data-sets and plain radiographic follow-ups were reviewed in 25 immunocompromised patients with confirmation of new onset HSV-1 pneumonia. Pattern and distribution of abnormalities was assessed by two chest radiologists and findings evaluated regarding outcome and dynamics. RESULTS: The most frequent CT abnormalities included ground-glass attenuation (n=18; 72%) in a bilateral, symmetric and random distribution, air-space consolidations (n=13; 52%) in a bilateral, asymmetric and peribronchial allocation and interlobular septal thickening (n=6; 24%). When classified by leading HRCT pattern, patients subdivided into distinct groups with either dominant ground-glass attenuation or air-space consolidation. Six patients died after a median 8 days of diagnosis; the median interval until complete radiographic remission of pathology was 20 days. Pre-dominance of air-space consolidations was associated with significant delay of improvement (p=0.023); however, patient outcome was comparable in both subgroups (p=0.9). CONCLUSION: Diagnosis of HSV pneumonia is challenging and requires familiarity with two distinct HRCT patterns: predominance of ground-glass opacities or air-space consolidations. Whilst the two forms are not linked to patient outcome they demonstrate a variable dynamic at follow-up.
Assuntos
Herpes Simples/diagnóstico por imagem , Herpes Simples/tratamento farmacológico , Herpesvirus Humano 1/imunologia , Hospedeiro Imunocomprometido/imunologia , Imunossupressores/uso terapêutico , Pneumonia Viral/tratamento farmacológico , Pneumonia Viral/imunologia , Adolescente , Adulto , Idoso , Feminino , Seguimentos , Herpes Simples/imunologia , Humanos , Masculino , Pneumonia Viral/diagnóstico por imagem , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatística como Assunto , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Adulto JovemRESUMO
BACKGROUND AND PURPOSE: IR has recently demonstrated its capacity to reduce noise and permit dose reduction in abdominal and thoracic CT applications. The purpose of our study was to assess the potential benefit of IR in head CT by comparing objective and subjective image quality with standard FBP at various dose levels. MATERIALS AND METHODS: Ninety consecutive patients were randomly assigned to undergo nonenhanced and contrast-enhanced head CT at a standard dose (320 mAs; CTDI, 60.1) or 15% (275 mAs; CTDI, 51.8) and 30% (225 mAs; CTDI, 42.3) dose reduction. All acquisitions were reconstructed with IR in image space, and FBP and images were assessed in terms of quantitative and qualitative IQ. RESULTS: Compared with FBP, IR resulted in lower image noise (P ≤ .02), higher CNR (P ≤ .03), and improved subjective image quality (P ≤ .002) at all dose levels. While degradation of objective and subjective IQ at 15% dose reduction was fully compensated by IR (CNR, 1.98 ± 0.4 at 320 mAs with FBP versus 2.05 ± 0.4 at 275 mAs with IR; IQ, 1.8 versus 1.7), IQ was considerably poorer at 70% standard dose despite using the iterative approach (CNR, 1.98 ± 0.3 at 320 mAs with FBP versus 1.85 ± 0.4 at 225 mAs with IR, P = .18; IQ, 1.8 versus 2.2, P = .03). Linear regression analysis of CNR against tube current suggests that standard CNR may be obtained until approximately 20.4% dose reduction when IR is used. CONCLUSIONS: Compared with conventional FBP, IR of head CT is associated with significant improvement of objective and subjective IQ and may allow dose reductions in the range of 20% without compromising standard image quality.
Assuntos
Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Processamento de Imagem Assistida por Computador/normas , Masculino , Pessoa de Meia-IdadeAssuntos
Neoplasias Gastrointestinais/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Mieloma Múltiplo/diagnóstico por imagem , Neoplasias Peritoneais/diagnóstico por imagem , Neoplasias Esplênicas/diagnóstico por imagem , Humanos , Metástase Linfática , Tomografia Computadorizada por Raios XAssuntos
Candidíase/diagnóstico , Aumento da Imagem , Processamento de Imagem Assistida por Computador , Hepatopatias/diagnóstico , Imageamento por Ressonância Magnética , Infecções Oportunistas/diagnóstico , Esplenopatias/diagnóstico , Tomografia Computadorizada por Raios X , Angiografia , Diagnóstico Diferencial , Humanos , Fígado/irrigação sanguínea , Abscesso Hepático/diagnóstico , Cirrose Hepática/diagnóstico , Fatores de RiscoAssuntos
Abscesso Abdominal/diagnóstico , Falha de Equipamento , Extravasamento de Materiais Terapêuticos e Diagnósticos/diagnóstico , Hérnia Abdominal/diagnóstico , Imageamento por Ressonância Magnética , Diálise Peritoneal Ambulatorial Contínua/efeitos adversos , Peritonite/diagnóstico , Tomografia Computadorizada por Raios X , Calcinose/diagnóstico , Doença Crônica , Diagnóstico Diferencial , Diálise Peritoneal Ambulatorial Contínua/instrumentação , Sensibilidade e EspecificidadeAssuntos
Aspergilose/diagnóstico por imagem , Pneumopatias Fúngicas/diagnóstico por imagem , Radiografia Torácica , Tomografia Computadorizada por Raios X , Adulto , Idoso , Aspergilose/epidemiologia , Aspergilose/etiologia , Sequestro Broncopulmonar/diagnóstico por imagem , Diagnóstico Diferencial , Feminino , Humanos , Hospedeiro Imunocomprometido , Pneumopatias Fúngicas/epidemiologia , Pneumopatias Fúngicas/etiologia , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Sensibilidade e Especificidade , Fatores de TempoRESUMO
PURPOSE: This study investigates the features of neutropenic enterocolitis (NE) in adults. MATERIALS AND METHODS: Chart and radiology report reviews were used to identify neutropenic patients with hematological diseases undergoing chemotherapy, who had CT scans for the clarification of abdominal symptoms between October 2003 and October 2009. Patients with any cause for enteritis other than NE were excluded. The scans were analyzed with respect to imaging features and location. Morphological findings were correlated with clinical data. RESULTS: Thirty-one patients with NE (median age 46 years; range 20 - 75) could be identified. Wall thickening and hyperemia could be found in all bowel segments from jejunum to rectum. The right hemicolon was the most frequent location in 19 patients (61%). Involvement was generalized in 6 patients (19%) and segmental in 25 cases (81%). The longer the duration of neutropenia, the more likely generalized involvement of the bowel was. In 8 patients who underwent CT follow-up, the appearance of bowel segments had completely (n = 5) or partially (n = 3) returned to normal at the latest 14 days after the initial diagnosis. Eight patients (26%) died 1 - 78 days after NE, 7 of who had previously recovered from NE. CONCLUSION: CT findings are useful for the diagnosis of NE and should be considered even in the presence of isolated small bowel involvement. The terms NE and typhlitis should thus no longer be used synonymously.
Assuntos
Antineoplásicos/toxicidade , Enterocolite Neutropênica/induzido quimicamente , Enterocolite Neutropênica/diagnóstico por imagem , Doenças Hematológicas/tratamento farmacológico , Processamento de Imagem Assistida por Computador , Tomografia Computadorizada por Raios X , Adulto , Idoso , Antineoplásicos/uso terapêutico , Feminino , Seguimentos , Humanos , Mucosa Intestinal/diagnóstico por imagem , Intestino Grosso/diagnóstico por imagem , Intestino Delgado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Remissão Espontânea , Sensibilidade e Especificidade , Adulto JovemRESUMO
OBJECTIVE: With the introduction of non-myeloablative hematopoietic cell transplantation, acute graft-versus-host-disease (GvHD) is frequently observed beyond the traditional 100 days cut-off. The aim of this study was to describe and compare CT features of gastrointestinal early and late-onset GvHD and to correlate findings with clinical and pathology grading. SUBJECTS AND METHODS: Abdominal CT scans were obtained in 20 patients with early and 15 with late-onset GvHD. Examinations were assessed for intestinal and extraintestinal abnormalities and findings compared between the two subgroups of GvHD. Distinct CT abnormalities as well as a CT-score integrating multiple pathologies were correlated with gut, clinical or pathology grading. RESULTS: Frequent intestinal abnormalities included wall thickening, abnormal enhancement, and excessive fluid-filling (94%, 89%, and 94%). 86% of patients showed concomitant small and large bowel involvement. A discontinuous distribution was observed in 54%. Bile tract abnormality was the most common extra-intestinal finding (74%). The distribution of pathologies was equal between subgroups of early or late-onset disease. Wall thickening and mucosal attenuation in non-enhanced scans were significantly related to clinical and pathology scores (P=0.018). Number of abnormal segments, small bowel dilatation, engorgement of the vasa recta, mesenteric fat stranding and ascites were linked to clinical grading (P=0.019). A CT-score integrating multiple abnormalities was correlated to gut, overall clinical and pathology grading (r=0.64, 0.57, 0.50). CONCLUSION: CT morphology of acute GvHD is independent of its time of onset and, thus, facilitates differential diagnosis of late-onset acute GvHD. Correlation of CT morphology with clinical and pathological grading is important in terms of prognosis and may help guiding the therapeutic approach.