RESUMO
OBJECTIVES: The main objective was to generate a GLobal OMERACT Ultrasound DActylitis Score (GLOUDAS) in psoriatic arthritis and to test its reliability. To this end, we assessed the validity, feasibility and applicability of ultrasound assessment of finger entheses to incorporate them into the scoring system. METHODS: The study consisted of a stepwise process. First, in cadaveric specimens, we identified enthesis sites of the fingers by ultrasound and gross anatomy, and then verified presence of entheseal tissue in histological samples. We then selected the entheses to be incorporated into a dactylitis scoring system through a Delphi consensus process among international experts. Next, we established and defined the ultrasound components of dactylitis and their scoring systems using Delphi methodology. Finally, we tested the interobserver and intraobserver reliability of the consensus- based scoring systemin patients with psoriatic dactylitis. RESULTS: 32 entheses were identified in cadaveric fingers. The presence of entheseal tissues was confirmed in all cadaveric samples. Of these, following the consensus process, 12 entheses were selected for inclusion in GLOUDAS. Ultrasound components of GLOUDAS agreed on through the Delphi process were synovitis, tenosynovitis, enthesitis, subcutaneous tissue inflammation and periextensor tendon inflammation. The scoring system for each component was also agreed on. Interobserver reliability was fair to good (κ 0.39-0.71) and intraobserver reliability good to excellent (κ 0.80-0.88) for dactylitis components. Interobserver and intraobserver agreement for the total B-mode and Doppler mode scores (sum of the scores of the individual abnormalities) were excellent (interobserver intraclass correlation coefficient (ICC) 0.98 for B-mode and 0.99 for Doppler mode; intraobserver ICC 0.98 for both modes). CONCLUSIONS: We have produced a consensus-driven ultrasound dactylitis scoring system that has shown acceptable interobserver reliability and excellent intraobserver reliability. Through anatomical knowledge, small entheses of the fingers were identified and histologically validated.
Assuntos
Artrite Psoriásica , Articulações dos Dedos , Índice de Gravidade de Doença , Ultrassonografia , Humanos , Artrite Psoriásica/diagnóstico por imagem , Reprodutibilidade dos Testes , Articulações dos Dedos/diagnóstico por imagem , Articulações dos Dedos/patologia , Ultrassonografia/métodos , Masculino , Feminino , Técnica Delphi , Sinovite/diagnóstico por imagem , Sinovite/patologia , Pessoa de Meia-Idade , Variações Dependentes do Observador , Entesopatia/diagnóstico por imagem , Tenossinovite/diagnóstico por imagem , Cadáver , Estudos de Viabilidade , Adulto , Idoso , Dedos/diagnóstico por imagem , Dedos/patologiaRESUMO
OBJECTIVE: To assess the construct validity of the novel Outcome Measures in Rheumatology (OMERACT) ultrasound (US) semiquantitative scoring system for morphological lesions in major salivary glands by comparing it with magnetic resonance imaging (MRI) and unstimulated whole salivary flow rates (U-WSFRs) in patients with primary Sjögren syndrome (pSS). METHODS: Nine sonographers applied the OMERACT 0-3 grayscale scoring system for parotid (PGs) and submandibular glands (SMGs) in 11 patients with pSS who also had MRIs performed. These were evaluated by 2 radiologists using a semiquantitative 0-3 scoring system for morphological lesions. The agreement between US and MRI and the association between U-WSFRs and imaging structural lesions was determined. A score ≥ 2 for both US and MRI was defined as gland pathology. RESULTS: The prevalence of US morphological lesions in 11 patients with a score ≥ 2 was 58% for PGs and 76% for SMGs, and 46% and 41% for PGs and SMGs, respectively, for MRI. The agreement between OMERACT US scores and MRI scores was 73-91% (median 82%) in the right PG and 73-91% (median 91%) in the left PG, 55-91% (median 55%) in the right SMG and 55-82% (median 55%) in the left SMG. When relations between the presence of hyposalivation and an US score ≥ 2 were examined, agreement was 91-100% (median 83%) in both PGs and 55-91% (median 67%) in both SMGs. CONCLUSION: There is moderate to strong agreement between the OMERACT US and MRI scores for major salivary glands in patients with pSS. Similar agreement ratios were observed between the higher OMERACT US scores and presence of hyposalivation.
Assuntos
Síndrome de Sjogren , Xerostomia , Humanos , Síndrome de Sjogren/diagnóstico por imagem , Glândulas Salivares/diagnóstico por imagem , Ultrassonografia , Xerostomia/diagnóstico por imagem , Imageamento por Ressonância MagnéticaRESUMO
OBJECTIVES: To develop an Outcome Measures in Rheumatology (OMERACT) ultrasonography score for monitoring disease activity in giant cell arteritis (GCA) and evaluate its metric properties. METHODS: The OMERACT Instrument Selection Algorithm was followed. Forty-nine members of the OMERACT ultrasonography large vessel vasculitis working group were invited to seven Delphi rounds. An online reliability exercise was conducted using images of bilateral common temporal arteries, parietal and frontal branches as well as axillary arteries from 16 patients with GCA and 7 controls. Sensitivity to change and convergent construct validity were tested using data from a prospective cohort of patients with new GCA in which ultrasound-based intima-media thickness (IMT) measurements were conducted at weeks 1, 3, 6, 12 and 24. RESULTS: Agreement was obtained (92.7%) for the OMERACT GCA Ultrasonography Score (OGUS), calculated as follows: sum of IMT measured in every segment divided by the rounded cut-off values of IMTs in each segment. The resulting value is then divided by the number of segments available. Thirty-five members conducted the reliability exercise, the interrater intraclass correlation coefficient (ICC) for the OGUS was 0.72-0.84 and the median intrareader ICC was 0.91. The prospective cohort consisted of 52 patients. Sensitivity to change between baseline and each follow-up visit up to week 24 yielded standardised mean differences from -1.19 to -2.16, corresponding to large and very large magnitudes of change, respectively. OGUS correlated moderately with erythrocyte sedimentation rate, C reactive protein and Birmingham Vasculitis Activity Score (corrcoeff 0.37-0.48). CONCLUSION: We developed a provisional OGUS for potential use in clinical trials.
Assuntos
Arterite de Células Gigantes , Humanos , Arterite de Células Gigantes/diagnóstico por imagem , Espessura Intima-Media Carotídea , Reprodutibilidade dos Testes , Estudos Prospectivos , Artérias Temporais/diagnóstico por imagem , Ultrassonografia/métodosRESUMO
OBJECTIVE: The aim of this exercise from the OMERACT Ultrasound subgroup on Sjögren's syndrome was to develop and assess the reliability of a consensus-based semiquantitative colour Doppler US scoring system for pathologic salivary gland vascularization in patients with primary Sjögren's syndrome (pSS). METHODS: Using the Delphi method, a colour Doppler semiquantitative scoring system for vascularization of bilateral parotid and submandibular glands was developed and tested in static images and on patients (9 pSS patients and 9 sonographers). Intra-reader and inter-reader reliability of grading the salivary glands were computed by weighted Cohen and Light's kappa analysis, respectively. RESULTS: The consensus-based semiquantitative score was: grade 0, no visible vascular signals; grade 1, focal, dispersed vascular signals; grade 2, diffuse vascular signals detected in <50% of the gland; grade 3, diffuse vascular signals in >50% of the gland. In static images, the intra- and inter-reader reliability showed excellent kappa values (95% CI) of 0.90 (0.87, 0.93) and 0.80 (0.74, 0.84), respectively, for all four salivary glands together. In patients, the intra- and inter-reader reliability for all four salivary glands together was kappa = 0.84 (0.73, 0.92) and 0.70 (0.64, 0.76), respectively. CONCLUSION: The consensus-based colour Doppler US scoring for the evaluation of salivary gland vascularization in pSS showed a good inter-reader reliability and excellent intra-reader reliability in static images and in patients. The clinical application of the developed scoring system should be tested in clinical settings.
Assuntos
Síndrome de Sjogren , Humanos , Inflamação/patologia , Reprodutibilidade dos Testes , Glândulas Salivares/diagnóstico por imagem , Glândulas Salivares/patologia , Síndrome de Sjogren/diagnóstico por imagem , Síndrome de Sjogren/patologia , Glândula Submandibular/diagnóstico por imagem , Ultrassonografia/métodosRESUMO
OBJECTIVE: To produce European League Against Rheumatism (EULAR) recommendations for the reporting of ultrasound studies in rheumatic and musculoskeletal diseases (RMDs). METHODS: Based on the literature reviews and expert opinion (through Delphi surveys), a taskforce of 23 members (12 experts in ultrasound in RMDs, 9 in methodology and biostatistics together with a patient research partner and a health professional in rheumatology) developed a checklist of items to be reported in every RMD study using ultrasound. This checklist was further refined by involving a panel of 79 external experts (musculoskeletal imaging experts, methodologists, journal editors), who evaluated its comprehensibility, feasibility and comprehensiveness. Agreement on each proposed item was assessed with an 11-point Likert scale, grading from 0 (total disagreement) to 10 (full agreement). RESULTS: Two face-to-face meetings, as well as two Delphi rounds of voting, resulted in a final checklist of 23 items, including a glossary of terminology. Twenty-one of these were considered 'mandatory' items to be reported in every study (such as blinding, development of scoring systems, definition of target pathologies) and 2 'optional' to be reported only if applicable, such as possible confounding factors (ie, ambient conditions) or experience of the sonographers. CONCLUSION: An EULAR taskforce developed a checklist to ensure transparent and comprehensive reporting of aspects concerning research and procedures that need to be presented in studies using ultrasound in RMDs. This checklist, if widely adopted by authors and editors, will greatly improve the interpretability of study development and results, including the assessment of validity, generalisability and applicability.
Assuntos
Doenças Musculoesqueléticas/diagnóstico por imagem , Projetos de Pesquisa/normas , Doenças Reumáticas/diagnóstico por imagem , Reumatologia/normas , Ultrassonografia/métodos , HumanosRESUMO
BACKGROUND: To assess the reliability of the consensually agreed US definitions of major salivary gland lesions and the US scoring system for salivary gland assessment in patients with SS. METHODS: Nine experienced sonographers scanned and read the US images of both parotid glands (PGs) and submandibular glands (SMGs) in eight patients with primary and secondary SS in two rounds. A consensually agreed four-grade semi-quantitative scoring was applied in B-mode for morphological lesions: grade 0, normal; grade 1, mild inhomogeneity without anechoic or hypoechoic areas; grade 2, moderate inhomogeneity with focal anechoic or hypoechoic areas; grade 3, severe inhomogeneity with diffuse an- or hypoechoic areas occupying the entire gland or fibrous gland. The presence or absence of typical SS lesions, i.e. the Sjögren's signature, was scored binary. Intra- and interreader reliabilities were computed using weighted and unweighted Cohen's and Light's κ coefficients. RESULTS: The mean prevalence of grades 0-3 in PG were 43, 17, 23 and 31% and 28, 14, 33 and 32% for the SMGs, respectively. The weighted κ for intrareader reliability ranged from 0.44 to 1 for grading and 0.64 to 1 for the Sjögren's signature of PG and 0.59 to 1 and -0.09 to 0.6 for SMGs, respectively. The interreader reliability κ for grading in PG was 0.62 (95% CI 0.47, 0.74) and for Sjögren's signature it was 0.36 (95% CI 0, 0.43); in SMG it was 0.62 (95% CI 0.47, 0.72) and 0.03 (95% CI 0, 0.07) respectively. CONCLUSIONS: The consensually agreed novel US scoring system for major salivary gland lesions showed substantial intra- and interreader reliability in patients with SS. The reliability of the Sjögren's signature was moderate.
Assuntos
Glândula Parótida/diagnóstico por imagem , Síndrome de Sjogren/diagnóstico por imagem , Glândula Submandibular/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Reprodutibilidade dos Testes , UltrassonografiaRESUMO
OBJECTIVES: Suboptimal medication adherence is a serious problem in the treatment of chronic inflammatory diseases. To measure medication adherence, electronic monitoring is regarded as superior to pill count. GLORIA is an ongoing two-year trial on the addition of low-dose (5 mg/d) prednisolone or placebo to standard care in older people (65+ years) with RA. During the entire trial, adherence is measured with electronic caps, and with pill counts. The objective is to describe medication adherence patterns, and to compare the adherence results of the two methods. METHODS: The recorded adherence patterns of patients (blinded for treatment group) were classified according to descriptive categories. The cutoff for good adherence was set at 80% of prescribed pills taken. RESULTS: Trial inclusion closed in 2018 at 451 patients, but trial follow-up is ongoing; the current dataset contains adherence data of 371 patients. Mean number of recorded 90-day periods per patient was 4 (range 1-8). Based on pill count over all periods, 90% of the patients had good adherence; based on cap data, only 20%. Cap data classified 30% of patients as non-user (<20% of days an opening) and 40% as irregular user (different adherence patterns, in or between periods). CONCLUSION: In our trial of older people with RA, the majority appeared to be adherent to medication according to pill count. Results from caps conflicted with those of pill counts, with patterns suggesting patients did not use the bottle for daily dispensing, despite specific advice to do so. TRIAL REGISTRATION: NCT02585258. ClinicalTrials.gov (https://www.clinicaltrials.gov/).
Assuntos
Artrite Reumatoide/tratamento farmacológico , Embalagem de Medicamentos/estatística & dados numéricos , Glucocorticoides/uso terapêutico , Adesão à Medicação/estatística & dados numéricos , Prednisolona/uso terapêutico , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , MasculinoRESUMO
OBJECTIVES: U-Act-Early was a 2-year, randomized placebo controlled, double-blind trial, in which DMARD-naïve early RA patients were treated to the target of sustained remission (SR). Two strategies initiating tocilizumab (TCZ), with and without methotrexate (MTX), were more effective than a strategy initiating MTX. The aim of the current study was to determine longer-term effectiveness in daily clinical practice. METHODS: At the end of U-Act-Early, patients were included in a 3-year post-trial follow-up (PTFU), in which treatment was according to standard care and data were collected every 3 months during the first year and every 6 months thereafter. Primary end point was disease activity score assessing 28 joints (DAS28) over time. Mixed effects models were used to compare effectiveness between initial strategy groups, correcting for relevant confounders. Between the groups as randomized, proportions of patients were tested for DMARD use, SR and radiographic progression of joint damage. RESULTS: Of patients starting U-Act-Early, 226/317 (71%) participated in the PTFU. Over the total 5 years, mean DAS28 was similar between groups (P > 0.20). During U-Act-Early, biologic DMARD use decreased in both TCZ initiation groups and increased in the MTX initiation group, but during follow-up this trend did not continue. SR was achieved at least once in 99% of patients. Of the 226 patients, only 30% had any radiographic progression over 5 years, without significant differences between the groups. CONCLUSION: Although in the short-term the strategies initiating TCZ yielded the most clinical benefit, in the longer-term differences in important clinical outcomes between the strategies disappeared, probably due to continuation of the treat-to-target principle.
Assuntos
Anticorpos Monoclonais Humanizados/administração & dosagem , Antirreumáticos/administração & dosagem , Artrite Reumatoide/tratamento farmacológico , Metotrexato/administração & dosagem , Fatores de Tempo , Adulto , Idoso , Artrite Reumatoide/patologia , Progressão da Doença , Método Duplo-Cego , Quimioterapia Combinada , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Índice de Gravidade de Doença , Resultado do TratamentoRESUMO
OBJECTIVES: To assess the prevalence of clinical, US and radiographic hip involvement in AS patients with active disease and to explore the associations between these assessments. Furthermore, to evaluate the effect of 6 months of TNF-α blocking therapy on tender and inflammatory power Doppler US lesions of hip joints. METHODS: Consecutive AS patients starting TNF-α blocking therapy were evaluated for hip joint involvement. At baseline, patient-reported history of hip involvement was assessed and radiographic evaluation (BASRI-hip) was performed. Clinical examination (tender hip joints) and US examination took place before and after 6 months of treatment. RESULTS: Of the 111 included patients, 20% reported a history of hip involvement. At baseline, tender hip joints were present in 23% of patients. US examination showed inflammatory lesions in 17% of patients, of which 74% had positive power Doppler. Structural lesions were present in 20% of patients, of which 55% had osteophytes. Structural radiographic damage was seen in 10% of patients. Highest concordance was found between history of hip involvement and radiographic hip involvement (phi coefficient 0.333). After 6 months of TNF-α blocking therapy, significant decrease was found in tender hip joints (from 29 to 11), total number of inflammatory US lesions (from 29 to 9) and positive power Doppler (from 22 to 6). CONCLUSION: The prevalence rate of hip involvement in AS patients varies from 10 to 23%, depending on the type of hip assessment. TNF-α blocking therapy significantly improved tender hip joints, and inflammatory US lesions including positive power Doppler.
Assuntos
Articulação do Quadril/diagnóstico por imagem , Inflamação/diagnóstico por imagem , Espondilite Anquilosante/diagnóstico por imagem , Espondilite Anquilosante/tratamento farmacológico , Inibidores do Fator de Necrose Tumoral/uso terapêutico , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Índice de Gravidade de Doença , Ultrassonografia DopplerRESUMO
OBJECTIVES: To develop and test the reliability of a new semiquantitative scoring system for the assessment of cartilage changes by ultrasound in a web-based exercise as well as a patient exercise of patients with RA. METHODS: A taskforce of the Outcome Measures in Rheumatology Ultrasound Working Group performed a systematic literature review on the US assessment of cartilage in RA, followed by a Delphi survey on cartilage changes and a new semiquantitative US scoring system, and finally a web-based exercise as well as a patient exercise. For the web-based exercise, taskforce members scored a dataset of anonymized static images of MCP joints in RA patients and healthy controls, which also contained duplicate images. Subsequently, 12 taskforce members used the same US to score cartilage in MCP and proximal interphalangeal joints of six patients with RA in in a patient reliability exercise. Percentage agreement and prevalence of lesions were calculated, as intrareader reliability was assessed by weighted kappa and interreader reliability by Light's kappa. RESULTS: The three-grade semiquantitative scoring system demonstrated excellent intrareader reliability (kappa: 0.87 and 0.83) in the web-based exercise and the patient exercise, respectively. Interreader reliability was good in the web-based exercise (kappa: 0.64) and moderate (kappa: 0.48) in the patient exercise. CONCLUSION: Our study demonstrates that ultrasound is a reliable tool for evaluating cartilage changes in the MCP joints of patients with RA and supports further development of a new reliable semiquantitative ultrasound scoring system for evaluating cartilage involvement in RA.
Assuntos
Artrite Reumatoide/diagnóstico por imagem , Cartilagem/diagnóstico por imagem , Reumatologia/métodos , Índice de Gravidade de Doença , Ultrassonografia/estatística & dados numéricos , Adulto , Comitês Consultivos , Técnica Delphi , Feminino , Humanos , Masculino , Articulação Metacarpofalângica/diagnóstico por imagem , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Ultrassonografia/métodosRESUMO
OBJECTIVES: To evaluate associations between salivary gland ultrasonography (SGUS) and clinical characteristics, disease activity and outcome in patients with primary Sjögren's syndrome (pSS). METHODS: The parotid and submandibular salivary glands were examined by ultrasonography using two different scoring systems proposed by Hocevar et al. and Milic et al. on 85 pSS patients. Patients with inhomogeneity/hypoechoic areas with scores ≥2 in parotid and submandibular glands were classified as severe parotid or severe submandibular involvements, respectively. Disease activity and patient-reported severity were evaluated using the European League Against Rheumatism Sjögren's Disease Activity Index (ESSDAI) and the European League Against Rheumatism Sjögren's Patient Reported Index (ESSPRI). Salivary gland functional capacity was investigated by unstimulated whole saliva flow rate (U-WSFR). RESULTS: Of the activity scores, ESSPRI dryness component was higher in pSS patients who had scores above the cut-off values for Hocevar (6.1±2.3 vs. 4.9±2.6, p=0.026). The patients with any type of systemic involvement more frequently showed higher SGUS scores, according to both Hocevar (72.4 vs. 44.6%, p=0.013) and Milic (75.9 vs. 51.8%, p=0.026). These patients also showed a higher percentage of severe parotid/submandibular changes on US imaging (65.5 vs. 33.9%, p=0.005 and 75.9 vs. 51.8%, p=0.026 respectively). Higher SGUS scores according to cut-off values of both scoring systems and severe parotid/submandibular involvements were associated with both anti-Ro or double anti-Ro/La autoantibodies and inversely associated with U-WSFR. CONCLUSIONS: SGUS may be a useful imaging modality for the selection of patients with more severe disease status or who may require a tight follow-up schedule.
Assuntos
Glândula Parótida/diagnóstico por imagem , Glândulas Salivares/diagnóstico por imagem , Síndrome de Sjogren , Glândula Submandibular/diagnóstico por imagem , Ultrassonografia/métodos , Humanos , Índice de Gravidade de Doença , Síndrome de Sjogren/diagnóstico por imagemRESUMO
OBJECTIVES: To assess the reliability of the OMERACT ultrasound (US) definitions for the identification of calcium pyrophosphate deposition disease (CPPD) at the metacarpal-phalangeal, triangular fibrocartilage of the wrist (TFC), acromioclavicular (AC) and hip joints. METHODS: A web-based exercise and subsequent patient-based exercise were carried out. A panel of 30 OMERACT members, participated at the web-based exercise by evaluating twice a set of US images for the presence/absence of CPPD. Afterwards, 19 members of the panel met in Siena, Italy, for the patient-based exercise. During the exercise, all sonographers examined twice eight patients for the presence/absence of CPPD at the same joints. Intraoberserver and interobserver kappa values were calculated for both exercises. RESULTS: The web-based exercise yielded high kappa values both in intraobserver and interobserver evaluation for all sites, while in the patient-based exercise, inter-reader agreement was acceptable for the TFC and the AC. TFC reached high interobserver and intraobserver k values in both exercises, ranging from 0.75 to 0.87 (good to excellent agreement). AC reached moderate kappa values, from 0.51 to 0.85 (moderate to excellent agreement) and can readily be used for US CPPD identification. CONCLUSIONS: Based on the results of our exercise, the OMERACT US definitions for the identification of CPPD demonstrated to be reliable when applied to the TFC and AC. Other sites reached good kappa values in the web-based exercise but failed to achieve good reproducibility at the patient-based exercise, meaning the scanning method must be further refined.
Assuntos
Condrocalcinose/diagnóstico por imagem , Ultrassonografia/normas , Articulação Acromioclavicular/diagnóstico por imagem , Idoso , Feminino , Articulação do Quadril/diagnóstico por imagem , Humanos , Cooperação Internacional , Internet , Masculino , Articulação Metacarpofalângica/diagnóstico por imagem , Pessoa de Meia-Idade , Variações Dependentes do Observador , Sistemas de Informação em Radiologia , Reprodutibilidade dos Testes , Ultrassonografia/métodos , Articulação do Punho/diagnóstico por imagemRESUMO
BACKGROUND: For patients with newly diagnosed rheumatoid arthritis, treatment aim is early, rapid, and sustained remission. We compared the efficacy and safety of strategies initiating the interleukin-6 receptor-blocking monoclonal antibody tocilizumab with or without methotrexate (a conventional synthetic disease-modifying antirheumatic drug [DMARD]), versus initiation of methotrexate monotherapy in line with international guidelines. METHODS: We did a 2-year, multicentre, randomised, double-blind, double-dummy, strategy study at 21 rheumatology outpatient departments in the Netherlands. We included patients who had been diagnosed with rheumatoid arthritis within 1 year before inclusion, were DMARD-naive, aged 18 years or older, met current rheumatoid arthritis classification criteria, and had a disease activity score assessing 28 joints (DAS28) of at least 2·6. We randomly assigned patients (1:1:1) to start tocilizumab plus methotrexate (the tocilizumab plus methotrexate arm), or tocilizumab plus placebo-methotrexate (the tocilizumab arm), or methotrexate plus placebo-tocilizumab (the methotrexate arm). Tocilizumab was given at 8 mg/kg intravenously every 4 weeks with a maximum of 800 mg per dose. Methotrexate was started at 10 mg per week orally and increased stepwise every 4 weeks by 5 mg to a maximum of 30 mg per week, until remission or dose-limiting toxicity. We did the randomisation using an interactive web response system. Masking was achieved with placebos that were similar in appearance to the active drug; the study physicians, pharmacists, monitors, and patients remained masked during the study, and all assessments were done by masked assessors. Patients not achieving remission on their initial regimen switched from placebo to active treatments; patients in the tocilizumab plus methotrexate arm switched to standard of care therapy (typically methotrexate combined with a tumour necrosis factor inhibitor). When sustained remission was achieved, methotrexate (and placebo-methotrexate) was tapered and stopped, then tocilizumab (and placebo-tocilizumab) was also tapered and stopped. The primary endpoint was the proportion of patients achieving sustained remission (defined as DAS28 <2·6 with a swollen joint count ≤four, persisting for at least 24 weeks) on the initial regimen and during the entire study duration, compared between groups with a two-sided Cochran-Mantel-Haenszel test. Analysis was based on an intention-to-treat method. This trial was registered at ClinicalTrials.gov, number NCT01034137. FINDINGS: Between Jan 13, 2010, and July 30, 2012, we recruited and assigned 317 eligible patients to treatment (106 to the tocilizumab plus methotrexate arm, 103 to the tocilizumab arm, and 108 to the methotrexate arm). The study was completed by a similar proportion of patients in the three groups (range 72-78%). The most frequent reasons for dropout were adverse events or intercurrent illness: 27 (34%) of dropouts, and insufficient response: 26 (33%) of dropouts. 91 (86%) of 106 patients in the tocilizumab plus methotrexate arm achieved sustained remission on the initial regimen, compared with 86 (84%) of 103 in the tocilizumab arm, and 48 (44%) of 108 in the methotrexate arm (relative risk [RR] 2·00, 95% CI 1·59-2·51 for tocilizumab plus methotrexate vs methotrexate, and 1·86, 1·48-2·32 for tocilizumab vs methotrexate, p<0·0001 for both comparisons). For the entire study, 91 (86%) of 106 patients in the tocilizumab plus methotrexate arm, 91 (88%) of 103 in the tocilizumab arm, and 83 (77%) of 108 in the methotrexate arm achieved sustained remission (RR 1·13, 95% CI 1·00-1·29, p=0·06 for tocilizumab plus methotrexate vs methotrexate, 1·14, 1·01-1·29, p=0·0356 for tocilizumab vs methotrexate, and p=0·59 for tocilizumab plus methotrexate vs tocilizumab). Nasopharyngitis was the most common adverse event in all three treatment groups, occurring in 38 (36%) of 106 patients in the tocilizumab plus methotrexate arm, 40 (39%) of 103 in the tocilizumab arm, and 37 (34%) of 108 in the methotrexate arm. The occurrence of serious adverse events did not differ between the treatment groups (17 [16%] of 106 patients in the tocilizumab plus methotrexate arm vs 19 [18%] of 103 in the tocilizumab arm and 13 [12%] of 108 in the methotrexate arm), and no deaths occurred during the study. INTERPRETATION: For patients with newly diagnosed rheumatoid arthritis, strategies aimed at sustained remission by immediate initiation of tocilizumab with or without methotrexate are more effective, and with a similar safety profile, compared with initiation of methotrexate in line with current standards. FUNDING: Roche Nederland BV.
Assuntos
Anticorpos Monoclonais Humanizados/uso terapêutico , Antirreumáticos/uso terapêutico , Artrite Reumatoide/tratamento farmacológico , Metotrexato/uso terapêutico , Adulto , Anticorpos Monoclonais Humanizados/efeitos adversos , Antirreumáticos/efeitos adversos , Método Duplo-Cego , Quimioterapia Combinada , Feminino , Humanos , Masculino , Metotrexato/efeitos adversos , Pessoa de Meia-Idade , Indução de Remissão , Índice de Gravidade de Doença , Resultado do TratamentoRESUMO
BACKGROUND: In 2001, the European League Against Rheumatism developed and disseminated the first guidelines for musculoskeletal (MS) ultrasound (US) in rheumatology. Fifteen years later, the dramatic expansion of new data on MSUS in the literature coupled with technological developments in US imaging has necessitated an update of these guidelines. OBJECTIVES: To update the existing MSUS guidelines in rheumatology as well as to extend their scope to other anatomic structures relevant for rheumatology. METHODS: The project consisted of the following steps: (1) a systematic literature review of MSUS evaluable structures; (2) a Delphi survey among rheumatologist and radiologist experts in MSUS to select MS and non-MS anatomic structures evaluable by US that are relevant to rheumatology, to select abnormalities evaluable by US and to prioritise these pathologies for rheumatology and (3) a nominal group technique to achieve consensus on the US scanning procedures and to produce an electronic illustrated manual (ie, App of these procedures). RESULTS: Structures from nine MS and non-MS areas (ie, shoulder, elbow, wrist and hand, hip, knee, ankle and foot, peripheral nerves, salivary glands and vessels) were selected for MSUS in rheumatic and musculoskeletal diseases (RMD) and their detailed scanning procedures (ie, patient position, probe placement, scanning method and bony/other landmarks) were used to produce the App. In addition, US evaluable abnormalities present in RMD for each anatomic structure and their relevance for rheumatology were agreed on by the MSUS experts. CONCLUSIONS: This task force has produced a consensus-based comprehensive and practical framework on standardised procedures for MSUS imaging in rheumatology.
Assuntos
Doenças Musculoesqueléticas/diagnóstico por imagem , Doenças Reumáticas/diagnóstico por imagem , Reumatologia/normas , Ultrassonografia/métodos , Ultrassonografia/normas , Consenso , Técnica Delphi , Europa (Continente) , HumanosRESUMO
To establish whether a cadaver model can serve as an effective surrogate for the detection of tendon damage characteristic of rheumatoid arthritis (RA). In addition, we evaluated intraobserver and interobserver agreement in the grading of RA-like tendon tears shown by US, as well as the concordance between the US findings and the surgically induced lesions in the cadaver model. RA-like tendon damage was surgically induced in the tibialis anterior tendon (TAT) and tibialis posterior tendon (TPT) of ten ankle/foot fresh-frozen cadaveric specimens. Of the 20 tendons examined, six were randomly assigned a surgically induced partial tear; six a complete tear; and eight left undamaged. Three rheumatologists, experts in musculoskeletal US, assessed from 1 to 5 the quality of US imaging of the cadaveric models on a Likert scale. Tendons were then categorized as having either no damage, (0); partial tear, (1); or complete tear (2). All 20 tendons were blindly and independently evaluated twice, over two rounds, by each of the three observers. Overall, technical performance was satisfactory for all items in the two rounds (all values over 2.9 in a Likert scale 1-5). Intraobserver and interobserver agreement for US grading of tendon damage was good (mean κ values 0.62 and 0.71, respectively), with greater reliability found in the TAT than the TPT. Concordance between US findings and experimental tendon lesions was acceptable (70-100 %), again greater for the TAT than for the TPT. A cadaver model with surgically created tendon damage can be useful in evaluating US metric properties of RA tendon lesions.
Assuntos
Traumatismos do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/diagnóstico por imagem , Artrite Reumatoide/diagnóstico por imagem , Traumatismos dos Tendões/diagnóstico por imagem , Tendões/diagnóstico por imagem , Ultrassonografia , Idoso , Idoso de 80 Anos ou mais , Cadáver , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Distribuição Aleatória , Reprodutibilidade dos Testes , Índice de Gravidade de DoençaRESUMO
OBJECTIVE: To produce consensus-based definitions of the US elementary lesions in gout and to test their reliability in a web-based exercise. METHODS: The process consisted of two steps. In the first step a written Delphi questionnaire was developed from a systematic literature review and expert international consensus. This collated information resulted in four statements defining US elementary lesions: double contour (DC), tophus, aggregates and erosion. The Delphi questionnaire was sent to 35 rheumatology experts in US, asking them to rate their level of agreement or disagreement with each statement. The second step tested the reliability by a web-exercise. US images of both normal and gouty elementary lesions were collected by the participants. A facilitator then constructed an electronic database of 110 images. The database was sent to the participants, who evaluated the presence/absence of US elementary lesions. A group of 20 images was displayed twice to evaluate intra-reader reliability. RESULTS: A total of 32 participants responded to the questionnaires. Good agreement (>80%) was obtained for US definitions on DC, tophus, aggregates and erosion in the Delphi exercise after three rounds. The reliability on images showed inter-reader κ values for DC, tophus, aggregates, erosion findings of 0.98, 0.71, 0.54 and 0.85, respectively. The mean intra-reader κ values were also acceptable: 0.93, 0.78, 0.65 and 0.78, respectively. CONCLUSION: This, the first consensus-based US definition of elementary lesions in gout, demonstrated good reliability overall. It constitutes an essential step in developing a core outcome measurement that permits a higher degree of homogeneity and comparability between multicentre studies.
Assuntos
Técnica Delphi , Gota/diagnóstico por imagem , Gota/diagnóstico , Internet , Inquéritos e Questionários , Diagnóstico por Imagem/métodos , Humanos , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Terminologia como Assunto , UltrassonografiaRESUMO
OBJECTIVE: To develop the first ultrasound scoring system of tendon damage in rheumatoid arthritis (RA) and assess its intraobserver and interobserver reliability. METHODS: We conducted a Delphi study on ultrasound-defined tendon damage and ultrasound scoring system of tendon damage in RA among 35 international rheumatologists with experience in musculoskeletal ultrasound. Twelve patients with RA were included and assessed twice by 12 rheumatologists-sonographers. Ultrasound examination for tendon damage in B mode of five wrist extensor compartments (extensor carpi radialis brevis and longus; extensor pollicis longus; extensor digitorum communis; extensor digiti minimi; extensor carpi ulnaris) and one ankle tendon (tibialis posterior) was performed blindly, independently and bilaterally in each patient. Intraobserver and interobserver reliability were calculated by κ coefficients. RESULTS: A three-grade semiquantitative scoring system was agreed for scoring tendon damage in B mode. The mean intraobserver reliability for tendon damage scoring was excellent (κ value 0.91). The mean interobserver reliability assessment showed good κ values (κ value 0.75). The most reliable were the extensor digiti minimi, the extensor carpi ulnaris, and the tibialis posterior tendons. An ultrasound reference image atlas of tenosynovitis and tendon damage was also developed. CONCLUSIONS: Ultrasound is a reproducible tool for evaluating tendon damage in RA. This study strongly supports a new reliable ultrasound scoring system for tendon damage.
Assuntos
Artrite Reumatoide/complicações , Tenossinovite/diagnóstico por imagem , Tenossinovite/etiologia , Adulto , Idoso , Artrite Reumatoide/diagnóstico por imagem , Técnica Delphi , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Ruptura/diagnóstico por imagem , Ruptura/etiologia , Índice de Gravidade de Doença , Traumatismos dos Tendões/diagnóstico por imagem , Traumatismos dos Tendões/etiologia , Tendões/diagnóstico por imagem , UltrassonografiaRESUMO
OBJECTIVES: Over the last years ultrasound has shown to be an important tool for evaluating lung involvement, including interstitial lung disease (ILD) a potentially severe systemic involvement in many rheumatic and musculoskeletal diseases (RMD). Despite the potential sensitivity of the technique the actual use is hampered by the lack of consensual definitions of elementary lesions to be assessed and of the scanning protocol to apply. Within the Outcome Measures in Rheumatology (OMERACT) Ultrasound Working Group we aimed at developing consensus-based definitions for ultrasound detected ILD findings in RMDs and assessing their reliability in dynamic images. METHODS: Based on the results from a systematic literature review, several findings were identified for defining the presence of ILD by ultrasound (i.e., Am-lines, B-lines, pleural cysts and pleural line irregularity). Therefore, a Delphi survey was conducted among 23 experts in sonography to agree on which findings should be included and on their definitions. Subsequently, a web-reliability exercise was performed to test the reliability of the agreed definitions on video-clips, by using kappa statistics. RESULTS: After three rounds of Delphi an agreement >75 % was obtained to include and define B-lines and pleural line irregularity as elementary lesions to assess. The reliability in the web-based exercise, consisting of 80 video-clips (30 for pleural line irregularity, 50 for B-lines), showed moderate inter-reader reliability for both B-lines (kappa = 0.51) and pleural line irregularity (kappa = 0.58), while intra-reader reliability was good for both B-lines (kappa = 0.72) and pleural line irregularity (kappa = 0.75). CONCLUSION: Consensus-based ultrasound definitions for B-lines and pleural line irregularity were obtained, with moderate to good reliability to detect these lesions using video-clips. The next step will be testing the reliability in patients with ILD linked to RMDs and to propose a consensual and standardized protocol to scan such patients.
Assuntos
Técnica Delphi , Doenças Pulmonares Intersticiais , Ultrassonografia , Humanos , Doenças Pulmonares Intersticiais/diagnóstico por imagem , Ultrassonografia/normas , Reprodutibilidade dos Testes , Pulmão/diagnóstico por imagem , ConsensoRESUMO
OBJECTIVE: To produce consensus-based scoring systems for ultrasound (US) tenosynovitis and to assess the intraobserver and interobserver reliability of these scoring systems in rheumatoid arthritis (RA). METHODS: We undertook a Delphi process on US-defined tenosynovitis and US scoring system of tenosynovitis in RA among 35 rheumatologists, experts in musculoskeletal US (MSUS), from 16 countries. Then, we assessed the intraobserver and interobserver reliability of US in scoring tenosynovitis on B-mode and with a power Doppler (PD) technique. Ten patients with RA with symptoms in the hands or feet were recruited. Ten rheumatologists expert in MSUS blindly, independently and consecutively scored for tenosynovitis in B-mode and PD mode three wrist extensor compartments, two finger flexor tendons and two ankle tendons of each patient in two rounds in a blinded fashion. Intraobserver reliability was assessed by Cohen's κ. Interobserver reliability was assessed by Light's κ. Weighted κ coefficients with absolute weighting were computed for B-mode and PD signal. RESULTS: Four-grade semiquantitative scoring systems were agreed upon for scoring tenosynovitis in B-mode and for scoring pathological peritendinous Doppler signal within the synovial sheath. The intraobserver reliability for tenosynovitis scoring on B-mode and PD mode was good (κ value 0.72 for B-mode; κ value 0.78 for PD mode). Interobserver reliability assessment showed good κ values for PD tenosynovitis scoring (first round, 0.64; second round, 0.65) and moderate κ values for B-mode tenosynovitis scoring (first round, 0.47; second round, 0.45). CONCLUSIONS: US appears to be a reproducible tool for evaluating and monitoring tenosynovitis in RA.