Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 69
Filtrar
1.
Eur Radiol ; 33(8): 5740-5751, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36892641

RESUMO

OBJECTIVES: To compare the incidence of persistent air leak (PAL) following cryoablation vs MWA of lung tumors when the ablation zone includes the pleura. METHODS: This bi-institutional retrospective cohort study evaluated consecutive peripheral lung tumors treated with cryoablation or MWA from 2006 to 2021. PAL was defined as an air leak for more than 24 h after chest tube placement or an enlarging postprocedural pneumothorax requiring chest tube placement. The pleural area included by the ablation zone was quantified on CT using semi-automated segmentation. PAL incidence was compared between ablation modalities and a parsimonious multivariable model was developed to assess the odds of PAL using generalized estimating equations and purposeful selection of predefined covariates. Time-to-local tumor progression (LTP) was compared between ablation modalities using Fine-Gray models, with death as a competing risk. RESULTS: In total, 260 tumors (mean diameter, 13.1 mm ± 7.4; mean distance to pleura, 3.6 mm ± 5.2) in 116 patients (mean age, 61.1 years ± 15.3; 60 women) and 173 sessions (112 cryoablations, 61 MWA) were included. PAL occurred after 25/173 (15%) sessions. The incidence was significantly lower following cryoablation compared to MWA (10 [9%] vs 15 [25%]; p = .006). The odds of PAL adjusted for the number of treated tumors per session were 67% lower following cryoablation (odds ratio = 0.33 [95% CI, 0.14-0.82]; p = .02) vs MWA. There was no significant difference in time-to-LTP between ablation modalities (p = .36). CONCLUSIONS: Cryoablation of peripheral lung tumors bears a lower risk of PAL compared to MWA when the ablation zone includes the pleura, without adversely affecting time-to-LTP. KEY POINTS: • The incidence of persistent air leaks after percutaneous ablation of peripheral lung tumors was lower following cryoablation compared to microwave ablation (9% vs 25%; p = .006). • The mean chest tube dwell time was 54% shorter following cryoablation compared to MWA (p = .04). • Local tumor progression did not differ between lung tumors treated with percutaneous cryoablation compared to microwave ablation (p = .36).


Assuntos
Ablação por Cateter , Criocirurgia , Neoplasias Pulmonares , Ablação por Radiofrequência , Humanos , Feminino , Pessoa de Meia-Idade , Micro-Ondas/uso terapêutico , Estudos Retrospectivos , Neoplasias Pulmonares/cirurgia , Neoplasias Pulmonares/patologia , Resultado do Tratamento
2.
J Endovasc Ther ; : 15266028231158971, 2023 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-36891635

RESUMO

PURPOSE: The purpose of the study was to evaluate the midterm and long-term outcomes of patients who underwent thoracic endovascular aortic repair (TEVAR) procedure to treat an uncomplicated acute and subacute type B aortic dissection (uATBAD) with high risk for subsequent aortic complications compared with the group of patients who received a conservative treatment protocol during the same period. MATERIALS AND METHODS: Between 2008 and 2019, 35 patients who had TEVAR due to uATBAD and those with conservative procedure (n=18) were included in a retrospective analysis and follow-up study. The primary endpoints were false lumen thrombosis/perfusion, true lumen diameter, and aortic dilatation. The aortic-related mortality, reintervention, and long-term survival were the secondary endpoints. RESULTS: In the study period, 53 patients (22 females) with a mean age of 61.1±13 years were included. No 30-day and in-hospital mortality was recorded. Permanent neurological deficits occurred in 2 patients (5.7%). In the TEVAR group (n=35) and in a median follow-up period of 34 months, a significant reduction of maximum aortic and false lumen diameter as well as a significant increase of true lumen diameter were detected (p<0.001 each). Complete false lumen thrombosis increased from 6% preoperatively to 60% at follow-up. The median difference in aortic, false lumen, and true lumen diameter was -5 mm (interquartile range [IQR]=-28 to 8 mm), -11 mm (IQR=-53 to 10 mm), and 7 mm (IQR=-13 to 17 mm), respectively. In 3 patients (8.6%), a reintervention was needed. Two patients (1 aortic-related) died during follow-up. The estimated survival according to Kaplan-Meyer analysis was 94.1% after 3 years and 87.5% after 5 years. Similar to the TEVAR group, no 30-day or in-hospital mortality was recorded in the conservative group. During follow-up, 2 patients died and 5 patients underwent conversion-TEVAR (28%). In a median follow-up period of 26 months (range=150), a significant increase of maximum aortic diameter (p=0.006) and a tendency to augmentation of the false lumen (p=0.06) were noted. No significant reduction of the true lumen was seen. CONCLUSIONS: Thoracic endovascular aortic repair in patients at high risk of subsequent aortic complications in uncomplicated acute and subacute type B aortic dissection is safe and is associated with favorable midterm outcomes regarding aortic remodeling. CLINICAL IMPACT: In a retrospective, single center analysis of prospectively collected data with follow-up, we compared 35 patients with high-risk features who recieved TEVAR in acute and sub-acute uncomplicated type B aortic dissection to a control-group (n=18). The TEVAR group showed a significant positive remoduling (reduction of max. aortic and false lumen diameter and increase of true lumen diameter (p<0.001 each)) during follow-up with an estimated survival of 94.1% after 3 years and 87.5% after 5 years.

3.
Magn Reson Med ; 85(1): 197-208, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32783240

RESUMO

PURPOSE: Intracranial and intraspinal compliance are parameters of interest in the diagnosis and prediction of treatment outcome in patients with normal pressure hydrocephalus and other forms of communicating hydrocephalus. A noninvasive method to estimate the spinal cerebrospinal fluid (CSF) pulse wave velocity (PWV) as a measure of compliance was developed using a multiband cine phase-contrast MRI sequence and a foot-to-foot algorithm. METHODS: We used computational simulations to estimate the accuracy of the MRI acquisition and transit-time algorithm. In vitro measurements were performed to investigate the reproducibility and accuracy of the measurements under controlled conditions. In vivo measurements in 20 healthy subjects and 2 patients with normal pressure hydrocephalus were acquired to show the technical feasibility in a clinical setting. RESULTS: Simulations showed a mean deviation of the calculated CSF PWV of 3.41% ± 2.68%. In vitro results were in line with theory, showing a square-root relation between PWV and transmural pressure and a good reproducibility with SDs of repeated measurements below 5%. Mean CSF PWV over all healthy subjects was 5.83 ± 3.36 m/s. The CSF PWV measurements in the patients with normal pressure hydrocephalus were distinctly higher before CSF shunt surgery (33.80 ± 6.75 m/s and 31.31 ± 7.82 m/s), with a decrease 5 days after CSF shunt surgery (15.69 ± 3.37 m/s). CONCLUSION: This study evaluates the feasibility of CSF PWV measurements using a multiband cine phase-contrast MRI sequence. In vitro and in vivo measurements showed that this method is a potential tool for the noninvasive estimation of intraspinal compliance.


Assuntos
Hidrocefalia de Pressão Normal , Análise de Onda de Pulso , Algoritmos , Líquido Cefalorraquidiano/diagnóstico por imagem , Humanos , Hidrocefalia de Pressão Normal/diagnóstico por imagem , Imageamento por Ressonância Magnética , Imagem Cinética por Ressonância Magnética , Reprodutibilidade dos Testes
4.
Ann Surg Oncol ; 28(11): 5829-5839, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33620616

RESUMO

OBECTIVE: The aim of this study was to report outcomes following percutaneous microwave and cryoablation of lung metastases from adenoid cystic carcinoma (ACC) of the head and neck. MATERIAL AND METHODS: This bi-institutional retrospective cohort study included 10 patients (6 females, median age 59 years [range 28-81]) who underwent 32 percutaneous ablation sessions (21 cryoablation, 11 microwave) of 60 lung metastases (median 3.5 tumors per patient [range 1-16]) from 2007 to 2019. Median tumor diameter was 16 mm [range 7-40], significantly larger for cryoablation (22 mm, p = 0.002). A median of two tumors were treated per session [range 1-7]. Technical success, local control, complications, and overall survival were assessed. RESULTS: Primary technical success was achieved for 55/60 tumors (91.7%). Median follow-up was 40.6 months (clinical) and 32.5 months (imaging, per tumor). Local control at 1, 2, and 3 years was 94.7%, 80.8%, and 76.4%, respectively, and did not differ between ablation modalities. Five of fifteen recurrent tumors underwent repeat ablation, and secondary technical success was achieved in four (80%). Assisted local tumor control at 1, 2, and 3 years was 96.2%, 89.8%, and 84.9%, respectively. Complications occurred following 24/32 sessions (75.0%) and 57.2% Common Terminology Criteria for Adverse Events (CTCAE) lower than grade 3. Of 13 pneumothoraces, 7 required chest tube placements. Hemoptysis occurred after 7/21 cryoablation sessions, and bronchopleural fistula developed more frequently with microwave (p = 0.037). Median length of hospital stay was 1 day [range 0-10], and median overall survival was 81.5 months (IQR 40.4-93.1). CONCLUSION: Percutaneous computed tomography-guided microwave and cryoablation can treat lung metastases from ACC of the head and neck. Complications are common but manageable, with full recovery expected.


Assuntos
Carcinoma Adenoide Cístico , Criocirurgia , Neoplasias Renais , Neoplasias Pulmonares , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Adenoide Cístico/cirurgia , Feminino , Humanos , Neoplasias Renais/cirurgia , Neoplasias Pulmonares/cirurgia , Micro-Ondas/uso terapêutico , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
5.
Acta Radiol ; 60(2): 160-167, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29807442

RESUMO

BACKGROUND: Advanced knowledge-based iterative model reconstructions (IMR) became recently available for routine computed tomography (CT). Using more realistic physical models it promises improved image quality and potential radiation dose reductions, both possibly beneficial for non-invasive assessment of coronary stents. PURPOSE: To evaluate the influence of different IMR settings at different radiation doses on stent lumen visualization in comparison to filtered back projection (FBP) and first-generation (hybrid) iterative reconstruction (HIR). MATERIAL AND METHODS: Ten coronary stents in a coronary phantom were examined at four different dose settings (120 kV/125 mAs, 120 kV/75 mAs, 100 kV/125 mAs, 100 kV/75 mAs). Images were reconstructed with stent-specific FBP and HIR kernels and with IMR using CardiacRoutine (CR) and CardiacSharp (CS) settings at three different iteration levels. Image quality was evaluated using established parameters: image noise; in-stent attenuation difference; and visible lumen diameter. RESULTS: Image noise was significantly lower in IMR than in corresponding HIR and FBP images. At lower radiation doses, image noise increased significantly except with IMR CR3 and IMR CS3. Visible lumen diameters were significantly larger with IMR CS than with FBP, HIR, and IMR CR. IMR CR showed the smallest attenuation difference, while attenuation was artificially decreased extensively with IMR CS. FBP and HIR showed moderately increased in-stent attenuations. No relevant influence of used radiation doses on visible lumen diameters or attenuation differences was found. CONCLUSION: IMR CR reduces image noise significantly while offering comparable stent-specific image quality in comparison to FBP and HIR and therefore potentially facilitates stent lumen delineation. Utilization of IMR CS for stent evaluation seems unfavorable due to artificial image alterations.


Assuntos
Vasos Coronários/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Stents , Tomografia Computadorizada por Raios X/métodos , Humanos , Técnicas In Vitro , Imagens de Fantasmas , Doses de Radiação
6.
MAGMA ; 31(1): 165-172, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28921052

RESUMO

OBJECTIVES: The objective of the current work was to evaluate flow and turbulent kinetic energy in different transcatheter aortic valve implants using highly undersampled time-resolved multi-point 3-directional phase-contrast measurements (4D Flow MRI) in an in vitro setup. MATERIALS AND METHODS: A pulsatile flow setup was used with a compliant tubing mimicking a stiff left ventricular outflow tract and ascending aorta. Five different implants were measured using a highly undersampled multi-point 4D Flow MRI sequence. Velocities and turbulent kinetic energy values were analysed and compared. RESULTS: Strong variations of turbulent kinetic energy distributions between the valves were observed. Maximum turbulent kinetic energy values ranged from 100 to over 500 J/m3 while through-plane velocities were similar between all valves. CONCLUSION: Highly accelerated 4D Flow MRI for the measurement of velocities and turbulent kinetic energy values allowed for the assessment of hemodynamic parameters in five different implant models. The presented setup, measurement protocol and analysis methods provides an efficient approach to compare different valve implants and could aid future novel valve designs.


Assuntos
Valva Aórtica , Técnicas de Imagem Cardíaca/métodos , Próteses Valvulares Cardíacas , Imageamento por Ressonância Magnética/métodos , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Velocidade do Fluxo Sanguíneo , Hemorreologia , Humanos , Imageamento Tridimensional/métodos , Técnicas In Vitro , Imagem Cinética por Ressonância Magnética/métodos , Desenho de Prótese
7.
Acta Radiol ; 59(9): 1060-1065, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29181989

RESUMO

Background Non-invasive evaluation of coronary stent patency by coronary computed tomography angiography (cCTA) remains challenging. Multiple studies showed that CT technology but also individual stent design strongly influence the assessability of coronary stents by cCTA. Purpose To expand the available data on cCTA characteristics of coronary stents by 24 novel types to help interpreting examinations of patients after stent placement and selecting which stents are suitable for assessment by cCTA. Material and Methods Twenty-four novel coronary stents (17 cobalt-chromium, six stainless-steel, one platinum-chromium) were examined in a coronary phantom. Standard cCTA parameters with stent-specific algorithms were used. Image quality was quantified for each stent using established parameters (in-stent attenuation alteration and visible lumen diameter). Results Most stents (n = 14) showed lumen visibilities of 45-55%. No severe restriction of lumen visibility (>60%) was found. The majority of stents (n = 13) caused only small intraluminal attenuation deviations and no severe alterations (>20%) were found. When grouped by manufacturing material, no significant differences were found between cobalt-chromium and stainless-steel with identical mean visible diameters (1.52 ± 0.17 mm vs. 1.52 ± 0.13 mm) and comparable attenuation alterations (35.04 ± 16.56 HU vs. 21.25 ± 14.60 HU). The only platinum-chromium stent showed a smaller visible diameter (1.23 mm) and higher attenuation alteration (41.70 HU), but was also deemed to be assessable by cCTA. Conclusion All 24 novel evaluated stents are eligible for non-invasive evaluation by cCTA without significant differences between cobalt-chromium and stainless-steel stents. This updated catalogue of CT appearances of current coronary stents may serve as reference when taking care of patients with stents in need of coronary imaging.


Assuntos
Angiografia por Tomografia Computadorizada , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Desenho de Prótese , Stents , Humanos , Técnicas In Vitro , Grau de Desobstrução Vascular
9.
Eur Radiol ; 27(12): 5169-5178, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28656464

RESUMO

OBJECTIVES: To re-evaluate a recently suggested approach of quantifying myocardial oedema and increased tissue inhomogeneity in myocarditis by T2-mapping. METHODS: Cardiac magnetic resonance data of 99 patients with myocarditis were retrospectively analysed. Thirthy healthy volunteers served as controls. T2-mapping data were acquired at 1.5 T using a gradient-spin-echo T2-mapping sequence. T2-maps were segmented according to the 16-segments AHA-model. Segmental T2-values, segmental pixel-standard deviation (SD) and the derived parameters maxT2, maxSD and madSD were analysed and compared to the established Lake Louise criteria (LLC). RESULTS: A re-estimation of logistic regression models revealed that all models containing an SD-parameter were superior to any model containing global myocardial T2. Using a combined cut-off of 1.8 ms for madSD + 68 ms for maxT2 resulted in a diagnostic sensitivity of 75% and specificity of 80% and showed a similar diagnostic performance compared to LLC in receiver-operating-curve analyses. Combining madSD, maxT2 and late gadolinium enhancement (LGE) in a model resulted in a superior diagnostic performance compared to LLC (sensitivity 93%, specificity 83%). CONCLUSIONS: The results show that the novel T2-mapping-derived parameters exhibit an additional diagnostic value over LGE with the inherent potential to overcome the current limitations of T2-mapping. KEY POINTS: • A novel quantitative approach to myocardial oedema imaging in myocarditis was re-evaluated. • The T2-mapping-derived parameters maxT2 and madSD were compared to traditional Lake-Louise criteria. • Using maxT2 and madSD with dedicated cut-offs performs similarly to Lake-Louise criteria. • Adding maxT2 and madSD to LGE results in further increased diagnostic performance. • This novel approach has the potential to overcome the limitations of T2-mapping.


Assuntos
Edema Cardíaco/diagnóstico por imagem , Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Miocardite/diagnóstico por imagem , Adulto , Idoso , Estudos de Casos e Controles , Feminino , Gadolínio , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Miocardite/patologia , Estudos Retrospectivos , Sensibilidade e Especificidade
10.
J Cardiovasc Magn Reson ; 19(1): 71, 2017 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-28931401

RESUMO

BACKGROUND: The aim of this study was to evaluate the diagnostic potential of a novel cardiovascular magnetic resonance (CMR) based multiparametric imaging approach in suspected myocarditis and to compare it to traditional Lake Louise criteria (LLC). METHODS: CMR data from 67 patients with suspected acute myocarditis were retrospectively analyzed. Seventeen age- and gender-matched healthy subjects served as control. T2-mapping data were acquired using a Gradient-Spin-Echo T2-mapping sequence in short-axis orientation. T2-maps were segmented according to the 16-segments AHA-model and segmental T2 values and pixel-standard deviation (SD) were recorded. Afterwards, the parameters maxT2 (the highest segmental T2 value) and madSD (the mean absolute deviation (MAD) of the pixel-SDs) were calculated for each subject. Cine sequences in three long axes and a stack of short-axis views covering the left and right ventricle were analyzed using a dedicated feature tracking algorithm. RESULTS: A multiparametric imaging model containing madSD and LV global circumferential strain (GCSLV) resulted in the highest diagnostic performance in receiver operating curve analyses (area under the curve [AUC] 0.84) when compared to any model containing a single imaging parameter or to LLC (AUC 0.79). Adding late gadolinium enhancement (LGE) to the model resulted in a further increased diagnostic performance (AUC 0.93) and yielded the highest diagnostic sensitivity of 97% and specificity of 77%. CONCLUSIONS: A multiparametric CMR imaging model including the novel T2-mapping derived parameter madSD, the feature tracking derived strain parameter GCSLV and LGE yields superior diagnostic sensitivity in suspected acute myocarditis when compared to any imaging parameter alone and to LLC.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Miocardite/diagnóstico por imagem , Adulto , Algoritmos , Área Sob a Curva , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica , Miocardite/fisiopatologia , Valor Preditivo dos Testes , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos , Função Ventricular Esquerda , Função Ventricular Direita , Adulto Jovem
11.
Mol Med ; 22: 412-423, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27341515

RESUMO

The pathophysiology of sepsis involves activation of acid sphingomyelinase (SMPD1) with subsequent generation of the bioactive mediator ceramide. We herein evaluated the hypothesis that the enzyme exerts biological effects in endothelial stress response. Plasma-secreted sphingomyelinase activity, ceramide generation and lipid raft formation were measured in human microcirculatory endothelial cells (HMEC-1) stimulated with serum obtained from sepsis patients. Clustering of receptors relevant for signal transduction was studied by immuno staining. The role of SMPD1 for macrodomain formation was tested by pharmacological inhibition. To confirm the involvement of the stress enzyme, direct inhibitors (amino bisphosphonates) and specific downregulation of the gene was tested with respect to ADAMTS13 expression and cytotoxicity. Plasma activity and amount of SMPD1 were increased in septic patients dependent on clinical severity. Increased breakdown of sphingomyelin to ceramide in HMECs was observed following stimulation with serum from sepsis patients in vitro. Hydrolysis of sphingomyelin, clustering of receptor complexes, such as the CD95L/Fas-receptor, as well as formation of ceramide enriched macrodomains was abrogated using functional inhibitors (desipramine and NB6). Strikingly, the stimulation of HMECs with serum obtained from sepsis patients or mixture of proinflammatory cytokines resulted in cytotoxicity and ADAMTS13 downregulation which was abrogated using desipramine, amino bisphosphonates and genetic inhibitors. SMPD1 is involved in the dysregulation of ceramide metabolism in endothelial cells leading to macrodomain formation, cytotoxicity and downregulation of ADAMTS13 expression. Functional inhibitors, such as desipramine, are capable to improve endothelial stress response during sepsis and might be considered as a pharmacological treatment strategy to favor the outcome.

12.
J Magn Reson Imaging ; 44(5): 1168-1178, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27043352

RESUMO

PURPOSE: To elucidate the impact of technical and intraindividual reproducibility on the overall variability of myocardial T2 relaxation times. MATERIALS AND METHODS: Thirty healthy volunteers were examined three times (day 1 morning/evening, evening after 2-3 weeks) at 1.5T. During each examination three different T2 -mapping sequences were acquired twice at three slices in short axis view: multi-echo-spin-echo (MESE), T2 -prepared balanced steady-state free precession (SSFP) (T2 prep), and gradient-spin-echo with and without fat saturation (GraSE/GraSEFS ). Repeated measurements were performed for T2 prep and GraSE. Segmented T2 -maps were generated for each slice according to the American Heart Association (AHA) 16-segment model. RESULTS: The coefficients of variation and intraclass correlation coefficients for intraobserver variability were: 1.3% and 0.89 for T2 prep, 1.5% and 0.93 for GraSE, 3.1% and 0.83 for MESE; and for interobserver variability: 3.3% and 0.66 for T2 prep, 2.0% and 0.83 for GraSE, 3.6% and 0.77 for MESE. No systematic difference of T2 times was observed due to diurnal effects and on long-term analysis using one-way analysis of variance (ANOVA) with Tukey-type multiple comparisons (morning vs. evening scan for T2 prep: 52.5 ± 2.4 vs. 51.7 ± 2.7 msec, P = 0.119; for GraSE: 58.6 ± 4.0 vs. 58.5 ± 3.8 msec, P = 0.984; for GraSEFS 57.1 ± 3.2 vs. 57.2 ± 3.9 msec, P = 0.998, and for MESE: 53.8 ± 2.7 vs. 53.3 ± 3.3 msec, P = 0.541; scans between weeks for T2 prep: 51.7 ± 2.7 vs. 51.4 ± 2.4 msec, P = 0.873; for GraSE: 58.5 ± 3.8 vs. 58.1 ± 3.4 msec, P = 0.736; for GraSEFS : 57.2 ± 3.9 vs. 57.0 ± 4.6 msec, P = 0.964, and for MESE: 53.3 ± 3.3 vs. 53.4 ± 2.4 msec, P = 0.970). ANOVA components, however, demonstrated a greater variance of T2 times over multiple timepoints than for repeated measurements within the same scan (variance components of the model fit for intraday variance vs. repeated measurements: T2 prep 2.22 vs. 1.36, GraSE 3.76 vs. 2.09, GraSEFS 3.96 vs. 1.58, MESE 1.86; and for interweeks variance vs. repeated measurements: T2 prep 2.21 vs. 0.80, GraSE 3.20 vs. 2.10, GraSEFS 8.82 vs. 1.18, and MESE 4.49). CONCLUSION: Technical reproducibility and intra- and interobserver agreement of myocardial T2 relaxation times are excellent and intraindividual variation over time is small. Therefore, we consider subject-related factors to explain most of the interindividual variability of myocardial T2 times reported in previous studies. The acknowledgment of this subject-related, biological variability may be important for the future diagnostic value of T2 -mapping. J. Magn. Reson. Imaging 2016;44:1168-1178.


Assuntos
Algoritmos , Técnicas de Imagem Cardíaca/métodos , Ventrículos do Coração/anatomia & histologia , Ventrículos do Coração/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Processamento de Sinais Assistido por Computador , Adulto , Idoso , Simulação por Computador , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Modelos Estatísticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
13.
J Cardiovasc Magn Reson ; 17: 67, 2015 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-26231927

RESUMO

BACKGROUND: The aim of this study was the evaluation of a fast Gradient Spin Echo Technique (GraSE) for cardiac T2-mapping, combining a robust estimation of T2 relaxation times with short acquisition times. The sequence was compared against two previously introduced T2-mapping techniques in a phantom and in vivo. METHODS: Phantom experiments were performed at 1.5 T using a commercially available cylindrical gel phantom. Three different T2-mapping techniques were compared: a Multi Echo Spin Echo (MESE; serving as a reference), a T2-prepared balanced Steady State Free Precession (T2prep) and a Gradient Spin Echo sequence. For the subsequent in vivo study, 12 healthy volunteers were examined on a clinical 1.5 T scanner. The three T2-mapping sequences were performed at three short-axis slices. Global myocardial T2 relaxation times were calculated and statistical analysis was performed. For assessment of pixel-by-pixel homogeneity, the number of segments showing an inhomogeneous T2 value distribution, as defined by a pixel SD exceeding 20 % of the corresponding observed T2 time, was counted. RESULTS: Phantom experiments showed a greater difference of measured T2 values between T2prep and MESE than between GraSE and MESE, especially for species with low T1 values. Both, GraSE and T2prep resulted in an overestimation of T2 times compared to MESE. In vivo, significant differences between mean T2 times were observed. In general, T2prep resulted in lowest (52.4 ± 2.8 ms) and GraSE in highest T2 estimates (59.3 ± 4.0 ms). Analysis of pixel-by-pixel homogeneity revealed the least number of segments with inhomogeneous T2 distribution for GraSE-derived T2 maps. CONCLUSIONS: The GraSE sequence is a fast and robust sequence, combining advantages of both MESE and T2prep techniques, which promises to enable improved clinical applicability of T2-mapping in the future. Our study revealed significant differences of derived mean T2 values when applying different sequence designs. Therefore, a systematic comparison of different cardiac T2-mapping sequences and the establishment of dedicated reference values should be the goal of future studies.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Contração Miocárdica , Função Ventricular Esquerda , Adulto , Feminino , Voluntários Saudáveis , Humanos , Imagem Cinética por Ressonância Magnética/instrumentação , Masculino , Imagens de Fantasmas , Valor Preditivo dos Testes , Volume Sistólico , Fatores de Tempo , Adulto Jovem
14.
J Cardiovasc Magn Reson ; 17: 115, 2015 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-26700020

RESUMO

BACKGROUND: The purpose of the present study was to investigate the diagnostic value of T2-mapping in acute myocarditis (ACM) and to define cut-off values for edema detection. METHODS: Cardiovascular magnetic resonance (CMR) data of 31 patients with ACM were retrospectively analyzed. 30 healthy volunteers (HV) served as a control. Additionally to the routine CMR protocol, T2-mapping data were acquired at 1.5 T using a breathhold Gradient-Spin-Echo T2-mapping sequence in six short axis slices. T2-maps were segmented according to the 16-segments AHA-model and segmental T2 values as well as the segmental pixel-standard deviation (SD) were analyzed. RESULTS: Mean differences of global myocardial T2 or pixel-SD between HV and ACM patients were only small, lying in the normal range of HV. In contrast, variation of segmental T2 values and pixel-SD was much larger in ACM patients compared to HV. In random forests and multiple logistic regression analyses, the combination of the highest segmental T2 value within each patient (maxT2) and the mean absolute deviation (MAD) of log-transformed pixel-SD (madSD) over all 16 segments within each patient proved to be the best discriminators between HV and ACM patients with an AUC of 0.85 in ROC-analysis. In classification trees, a combined cut-off of 0.22 for madSD and of 68 ms for maxT2 resulted in 83% specificity and 81% sensitivity for detection of ACM. CONCLUSIONS: The proposed cut-off values for maxT2 and madSD in the setting of ACM allow edema detection with high sensitivity and specificity and therefore have the potential to overcome the hurdles of T2-mapping for its integration into clinical routine.


Assuntos
Edema Cardíaco/patologia , Imagem Cinética por Ressonância Magnética/métodos , Miocardite/patologia , Miocárdio/patologia , Doença Aguda , Adulto , Idoso , Suspensão da Respiração , Feminino , Fibrose , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos , Adulto Jovem
15.
J Biomech Eng ; 137(5): 051002, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25647090

RESUMO

The purpose of the present study was to compare subject-specific magnetic resonance imaging (MRI)-based computational fluid dynamics (CFD) simulations with time-resolved three-directional (3D) velocity-encoded phase-contrast MRI (4D PCMRI) measurements of the cerebrospinal fluid (CSF) velocity field in the cervical spinal subarachnoid space (SSS). Three-dimensional models of the cervical SSS were constructed based on MRI image segmentation and anatomical measurements for a healthy subject and patient with Chiari I malformation. CFD was used to simulate the CSF motion and compared to the 4D PCMRI measurements. Four-dimensional PCMRI measurements had much greater CSF velocities compared to CFD simulations (1.4 to 5.6× greater). Four-dimensional PCMRI and CFD both showed anterior and anterolateral dominance of CSF velocities, although this flow feature was more pronounced in 4D PCMRI measurements compared to CFD. CSF flow jets were present near the nerve rootlets and denticulate ligaments (NRDL) in the CFD simulation. Flow jets were visible in the 4D PCMRI measurements, although they were not clearly attributable to nerve rootlets. Inclusion of spinal cord NRDL in the cervical SSS does not fully explain the differences between velocities obtained from 4D PCMRI measurements and CFD simulations.


Assuntos
Líquido Cefalorraquidiano/fisiologia , Simulação por Computador , Hidrodinâmica , Imageamento por Ressonância Magnética , Modelagem Computacional Específica para o Paciente , Malformação de Arnold-Chiari/fisiopatologia , Humanos , Imageamento Tridimensional , Ligamentos/fisiologia , Ligamentos/fisiopatologia , Masculino , Modelos Biológicos , Raízes Nervosas Espinhais/fisiologia , Raízes Nervosas Espinhais/fisiopatologia , Adulto Jovem
16.
J Cardiovasc Magn Reson ; 16: 75, 2014 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-25315082

RESUMO

BACKGROUND: Fibrofatty degeneration of myocardium in ARVC is associated with wall motion abnormalities. The aim of this study was to examine whether Cardiovascular Magnetic Resonance (CMR) based strain analysis using feature tracking (FT) can serve as a quantifiable measure to confirm global and regional ventricular dysfunction in ARVC patients and support the early detection of ARVC. METHODS: We enrolled 20 patients with ARVC, 30 with borderline ARVC and 22 subjects with a positive family history but no clinical signs of a manifest ARVC. 10 healthy volunteers (HV) served as controls. 15 ARVC patients received genotyping for Plakophilin-2 mutation (PKP-2), of which 7 were found to be positive. Cine MR datasets of all subjects were assessed for myocardial strain using FT (TomTec Diogenes Software). Global strain and strain rate in radial, circumferential and longitudinal mode were assessed for the right and left ventricle. In addition strain analysis at a segmental level was performed for the right ventricular free wall. RESULTS: RV global longitudinal strain rates in ARVC (-0.68 ± 0.36 sec⁻¹) and borderline ARVC (-0.85 ± 0.36 sec⁻¹) were significantly reduced in comparison with HV (-1.38 ± 0.52 sec⁻¹, p ≤ 0.05). Furthermore, in ARVC patients RV global circumferential strain and strain rates at the basal level were significantly reduced compared with HV (strain: -5.1 ± 2.7 vs. -9.2 ± 3.6%; strain rate: -0.31 ± 0.13 sec(-1) vs. -0.61 ± 0.21 sec⁻¹). Even for patients with ARVC or borderline ARVC and normal RV ejection fraction (n=30) global longitudinal strain rate proved to be significantly reduced compared with HV (-0.9 ± 0.3 vs. -1.4 ± 0.5 sec(-1); p < 0.005). In ARVC patients with PKP-2 mutation there was a clear trend towards a more pronounced impairment in RV global longitudinal strain rate. On ROC analysis RV global longitudinal strain rate and circumferential strain rate at the basal level proved to be the best discriminators between ARVC patients and HV (AUC: 0.9 and 0.92, respectively). CONCLUSION: CMR based strain analysis using FT is an objective and useful measure for quantification of wall motion abnormalities in ARVC. It allows differentiation between manifest or borderline ARVC and HV, even if ejection fraction is still normal.


Assuntos
Displasia Arritmogênica Ventricular Direita/diagnóstico , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Contração Miocárdica , Volume Sistólico , Função Ventricular Esquerda , Função Ventricular Direita , Adolescente , Adulto , Idoso , Área Sob a Curva , Displasia Arritmogênica Ventricular Direita/genética , Displasia Arritmogênica Ventricular Direita/fisiopatologia , Fenômenos Biomecânicos , Diagnóstico Precoce , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Estudos Retrospectivos , Estresse Mecânico , Adulto Jovem
17.
J Heart Lung Transplant ; 43(1): 54-65, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37619642

RESUMO

BACKGROUND: While computed tomography pulmonary angiography (CTPA) is an integral part of the work-up in patients with suspected pulmonary hypertension (PH), there is no established CTPA-derived prognostic marker. We aimed to assess whether quantitative readouts of lung vessel morphology correlate with established prognostic indicators in PH. METHODS: We applied a fully-automatic in-house developed algorithm for segmentation of arteries and veins to determine lung vessel morphology in patients with precapillary PH who underwent right heart catheterization and CTPA between May 2016 and May 2019. Primary endpoint of this retrospective study was the calculation of receiver operating characteristics for identifying low and high mortality risk according to the 3-strata risk assessment model presented in the current guidelines. RESULTS: We analyzed 73 patients, median age 65 years (interquartile range (IQR): 54-76), female/male ratio 35/38, median mean pulmonary arterial pressure 37 mm Hg (IQR: 30-46), and found significant correlations with important prognostic factors in pulmonary arterial hypertension. N-terminal pro-brain natriuretic peptide, cardiac index, mixed venous oxygen saturation, and 6-minute walking distance were correlated with the ratio of the number of arteries over veins with vessel diameters of 6-10 mm (Spearman correlation coefficients ρ = 0.64, p < 0.001; ρ = -0.60, p < 0.001; ρ = -0.47, p = 0.005; ρ = -0.45, p = 0.001, respectively). This ratio predicted a low- and high-risk score with an area under the curve of 0.73 (95% confidence interval (CI): 0.56-0.90) and 0.86 (95% CI: 0.74-0.97), respectively. CONCLUSIONS: The ratio of the number of arteries over veins with diameters between 6 and 10 mm is significantly correlated with prognostic markers in pulmonary hypertension and predicts low and high mortality risk.


Assuntos
Hipertensão Pulmonar , Humanos , Masculino , Feminino , Idoso , Hipertensão Pulmonar/diagnóstico por imagem , Prognóstico , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Artéria Pulmonar/diagnóstico por imagem , Pulmão
18.
Int J Cardiol ; 390: 131203, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37480997

RESUMO

OBJECTIVE: To compare the measurement of aortic diameters using a novel flow-independent MR-Angiography (3D modified Relaxation-Enhanced Angiography without Contrast and Triggering (modified REACT)) and transthoracic echocardiography (TTE) in Marfan syndrome (MFS) patients. MATERIAL AND METHODS: This retrospective, single-center analysis included 46 examinations of 32 MFS patients (mean age 37.5 ± 11.3 years, 17 women, no prior aortic surgery) who received TTE and 3D modified REACT (ECG- and respiratory-triggering, Compressed SENSE factor 9 for acceleration of image acquisition) of the thoracic aorta. Aortic diameters (sinus of Valsalva (SV), sinotubular junction (STJ), and ascending aorta (AoA)) were independently measured by two cardiologists in TTE (leading-edge) and two radiologists in modified REACT (inner-edge, using multiplanar reconstruction). Intraclass correlation coefficient, Bland-Altman analyses, and Pearson's correlation (r) were used to assess agreement between observers and methods. RESULTS: Interobserver correlation at the SV, STJ, and AoA were excellent for both, TTE (ICC = 0.95-0.98) and modified REACT (ICC = 0.99-1.00). There was no significant difference between TTE and modified REACT for diameters measured at the SV (39.24 ± 3.24 mm vs. 39.63 ± 3.76 mm; p = 0.26; r = 0.78) and the STJ (35.16 ± 4.47 mm vs. 35.37 ± 4.74 mm; p = 0.552; r = 0.87). AoA diameters determined by TTE were larger than in modified REACT (34.29 ± 5.31 mm vs. 30.65 ± 5.64 mm; p < 0.01; r = 0.74). The mean scan time of modified REACT was 05:06 min ± 02:47 min, depending on the patient's breathing frequency and heart rate. CONCLUSIONS: Both TTE and modified REACT showed a strong correlation for all aortic levels; however, at the AoA, diameters were larger using TTE, mostly due to the limited field of view of the latter with measurements being closer to the aortic valve. Given the excellent interobserver correlation and the strong agreement with TTE, modified REACT represents an attractive method to depict the thoracic aorta in MFS patients.


Assuntos
Aorta Torácica , Síndrome de Marfan , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Aorta Torácica/diagnóstico por imagem , Síndrome de Marfan/diagnóstico por imagem , Estudos Retrospectivos , Ecocardiografia/métodos , Angiografia por Ressonância Magnética/métodos , Reprodutibilidade dos Testes
19.
Chest ; 163(4): 923-932, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36621756

RESUMO

BACKGROUND: Chronic thromboembolic pulmonary hypertension (CTEPH) is considered a complication of pulmonary embolism (PE). However, signs of CTEPH may exist in patients with a first symptomatic PE. RESEARCH QUESTION: Which radiologic findings on CT pulmonary angiography (CTPA) at the time of acute PE could indicate the presence of preexisting CTEPH? STUDY DESIGN AND METHODS: This study included unselected patients with acute PE who were prospectively followed up for 2 years with a structured visit schedule. Two expert radiologists independently assessed patients' baseline CTPAs for preexisting CTEPH; in case of disagreement, a decision was reached by a 2:1 majority with a third expert radiologist. In addition, the radiologists checked for predefined individual parameters suggesting chronic PE and pulmonary hypertension. RESULTS: Signs of chronic PE or CTEPH at baseline were identified in 46 of 303 included patients (15%). Intravascular webs, arterial narrowing or retraction, dilated bronchial arteries, and right ventricular hypertrophy were the main drivers of the assessment. Five (1.7%) patients were diagnosed with CTEPH during follow-up. All four patients diagnosed with CTEPH early (83-108 days following acute PE) were found in enriched subgroups based on the experts' overall assessment or fulfilling a minimum number of the predefined radiologic criteria at baseline. The specificity of preexisting CTEPH diagnosis and the level of radiologists' agreement improved as the number of required criteria increased. INTERPRETATION: Searching for predefined radiologic parameters suggesting preexisting CTEPH at the time of acute PE diagnosis may allow for targeted follow-up strategies and risk-adapted CTEPH screening, thus facilitating earlier CTEPH diagnosis.


Assuntos
Hipertensão Pulmonar , Embolia Pulmonar , Humanos , Hipertensão Pulmonar/complicações , Hipertensão Pulmonar/diagnóstico , Embolia Pulmonar/diagnóstico , Embolia Pulmonar/diagnóstico por imagem , Pulmão , Angiografia/efeitos adversos , Angiografia por Tomografia Computadorizada , Doença Crônica
20.
Eur Radiol ; 22(9): 1860-70, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22569996

RESUMO

OBJECTIVE: To analyse cerebrospinal fluid (CSF) hydrodynamics in patients with Chiari type I malformation (CM) with and without syringomyelia using 4D magnetic resonance (MR) phase contrast (PC) flow imaging. METHODS: 4D-PC CSF flow data were acquired in 20 patients with CM (12 patients with presyrinx/syrinx). Characteristic 4D-CSF flow patterns were identified. Quantitative CSF flow parameters were assessed at the craniocervical junction and the cervical spinal canal and compared with healthy volunteers and between patients with and without syringomyelia. RESULTS: Compared with healthy volunteers, 17 CM patients showed flow abnormalities at the craniocervical junction in the form of heterogeneous flow (n = 3), anterolateral flow jets (n = 14) and flow vortex formation (n = 5), most prevalent in patients with syringomyelia. Peak flow velocities at the craniocervical junction were significantly increased in patients (-15.5 ± 11.3 vs. -4.7 ± 0.7 cm/s in healthy volunteers, P < 0.001). At the level of C1, maximum systolic flow was found to be significantly later in the cardiac cycle in patients (30.8 ± 10.3 vs. 22.7 ± 4.1%, P < 0.05). CONCLUSIONS: 4D-PC flow imaging allowed comprehensive analysis of CSF flow in patients with Chiari I malformation. Alterations of CSF hydrodynamics were most pronounced in patients with syringomyelia.


Assuntos
Malformação de Arnold-Chiari/patologia , Malformação de Arnold-Chiari/fisiopatologia , Líquido Cefalorraquidiano/citologia , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Reologia/métodos , Siringomielia/patologia , Siringomielia/fisiopatologia , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA