Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
Eur J Pediatr ; 183(9): 4057-4062, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38960907

RESUMO

Duchenne muscular dystrophy is life-limiting. Cardiomyopathy, which mostly ensues in the second decade of life, is the main cause of death. Treatment options are still limited. The TAMDMD (NCT03354039) trial assessed motor function, muscle strength and structure, laboratory biomarkers, and safety in 79 ambulant boys with genetically confirmed Duchenne muscular dystrophy, 6.5-12 years of age, receiving either daily tamoxifen 20 mg or placebo for 48 weeks. In this post-hoc analysis, available echocardiographic data of ambulant patients recruited at one study centre were retrieved and compared before and after treatment. Data from 14 patients, median 11 (interquartile range, IQR, 11-12) years of age was available. Baseline demographic characteristics were similar in participants assigned to placebo (n = 7) or tamoxifen (n = 7). Left ventricular end-diastolic diameter in the placebo group (median and IQR) was 39 (38-41) mm at baseline and 43 (38-44) mm at study end, while it was 44 (41-46) mm at baseline and 41 (37-46) mm after treatment in the tamoxifen group. Left ventricular fractional shortening in the placebo group was 35% (32-38%) before and 33% (32-36%) after treatment, while in the tamoxifen group it was 34% (33-34%) at baseline and 35% (33-35%) at study end. No safety signals were detected. CONCLUSION: This hypothesis-generating post-hoc analysis suggests that tamoxifen over 48 weeks is well tolerated and may help preserving cardiac structure and function in Duchenne muscular dystrophy. Further studies are justified. CLINICALTRIALS: gov Identifier: EudraCT 2017-004554-42, NCT03354039 What is known: • Duchenne muscular dystrophy (DMD) is life-limiting. Cardiomyopathy ensues in the second decade of life and is the main cause of death. Treatment options are still limited. • Tamoxifen reduced cardiac fibrosis in mice and improved cardiomyocyte function in human-induced pluripotent stem cell-derived cardiomyocytes. WHAT IS NEW: • In this post-hoc analysis of the TAMDMD trial among 14 boys, median 11 years of age, treated with either tamoxifen or placebo for 48 weeks, treatment was well-tolerated. • A visual trend of improved left-ventricular dimensions and better systolic function preservation generates the hypothesis of a potential beneficial effect of tamoxifen in DMD cardiomyopathy.


Assuntos
Distrofia Muscular de Duchenne , Tamoxifeno , Humanos , Distrofia Muscular de Duchenne/tratamento farmacológico , Distrofia Muscular de Duchenne/fisiopatologia , Tamoxifeno/uso terapêutico , Tamoxifeno/efeitos adversos , Masculino , Criança , Cardiomiopatias/tratamento farmacológico , Cardiomiopatias/etiologia , Ecocardiografia , Método Duplo-Cego , Resultado do Tratamento
2.
Pediatr Radiol ; 2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-39017676

RESUMO

BACKGROUND: Ventricular volumetry using a short-axis stack of two-dimensional (D) cine balanced steady-state free precession (bSSFP) sequences is crucial in any cardiac magnetic resonance imaging (MRI) examination. This task becomes particularly challenging in children due to multiple breath-holds. OBJECTIVE: To assess the diagnostic performance of accelerated 3-RR cine MRI sequences using deep learning reconstruction compared with standard 2-D cine bSSFP sequences. MATERIAL AND METHODS: Twenty-nine consecutive patients (mean age 11 ± 5, median 12, range 1-17 years) undergoing cardiac MRI were scanned with a conventional segmented 2-D cine and a deep learning accelerated cine (three heartbeats) acquisition on a 1.5-tesla scanner. Short-axis volumetrics were performed (semi-)automatically in both datasets retrospectively by two experienced readers who visually assessed image quality employing a 4-point grading scale. Scan times and image quality were compared using the Wilcoxon rank-sum test. Volumetrics were assessed with linear regression and Bland-Altman analyses, and measurement agreement with intraclass correlation coefficient (ICC). RESULTS: Mean acquisition time was significantly reduced with the 3-RR deep learning cine compared to the standard cine sequence (45.5 ± 13.8 s vs. 218.3 ± 44.8 s; P < 0.001). No significant differences in biventricular volumetrics were found. Left ventricular (LV) mass was increased in the deep learning cine compared with the standard cine sequence (71.4 ± 33.1 g vs. 69.9 ± 32.5 g; P < 0.05). All volumetric measurements had an excellent agreement with ICC > 0.9 except for ejection fraction (EF) (LVEF 0.81, RVEF 0.73). The image quality of deep learning cine images was decreased for end-diastolic and end-systolic contours, papillary muscles, and valve depiction (2.9 ± 0.5 vs. 3.5 ± 0.4; P < 0.05). CONCLUSION: Deep learning cine volumetrics did not differ significantly from standard cine results except for LV mass, which was slightly overestimated with deep learning cine. Deep learning cine sequences result in a significant reduction in scan time with only slightly lower image quality.

3.
Fetal Diagn Ther ; 50(1): 8-16, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36617416

RESUMO

INTRODUCTION: The aim of this study was to evaluate the feasibility of identifying the fetal cardiac and thoracic vascular structures with non-gated dynamic balanced steady-state free precession (SSFP) MRI sequences. METHODS: We retrospectively assessed the visibility of cardiovascular anatomy in 60 fetuses without suspicion of congenital heart defect. Non-gated dynamic balanced SSFP sequences were acquired in three anatomic planes of the fetal thorax. The images were analyzed following a segmental approach in consensus reading by an experienced pediatric cardiologist and radiologist. An imaging score was defined by giving one point to each visualized structure, yielding a maximum score of 21 points. Image quality was rated from 0 (poor) to 2 (excellent). The influence of gestational age (GA), field strength, placenta position, and maternal panniculus on image quality and imaging score were tested. RESULTS: 30 scans were performed at 1.5T, 30 at 3T. Heart position, atria, and ventricles could be seen in all 60 fetuses. Basic diagnosis (>12 points) was achieved in 54 cases. The mean imaging score was 16.8+/-3.8. Maternal panniculus (r = -0.3; p = 0.015) and GA (r = 0.6; p < 0.001) correlated with imaging score. Field strength influenced image quality, with 1.5T being better than 3T images (p = 0.012). Imaging score or quality was independent of placenta position. CONCLUSION: Fetal cardiac MRI with non-gated SSFP sequences enables recognition of basic cardiovascular anatomy.


Assuntos
Cardiopatias Congênitas , Imageamento por Ressonância Magnética , Gravidez , Criança , Feminino , Humanos , Estudos Retrospectivos , Estudos de Viabilidade , Imageamento por Ressonância Magnética/métodos , Feto , Cardiopatias Congênitas/diagnóstico por imagem
4.
Radiol Med ; 128(10): 1225-1235, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37620674

RESUMO

PURPOSE: Four-dimensional time-resolved phase-contrast cardiovascular magnetic resonance imaging (4D flow MRI) enables blood flow quantification in multiple vessels, which is crucial for patients with congenital heart disease (CHD). We investigated net flow volumes in the ascending aorta and pulmonary arteries by four different postprocessing software packages for 4D flow MRI in comparison with 2D cine phase-contrast measurements (2D PC). MATERIAL AND METHODS: 4D flow and 2D PC datasets of 47 patients with biventricular CHD (median age 16, range 0.6-52 years) were acquired at 1.5 T. Net flow volumes in the ascending aorta, the main, right, and left pulmonary arteries were measured using four different postprocessing software applications and compared to offset-corrected 2D PC data. Reliability of 4D flow postprocessing software was assessed by Bland-Altman analysis and intraclass correlation coefficient (ICC). Linear regression of internal flow controls was calculated. Interobserver reproducibility was evaluated in 25 patients. RESULTS: Correlation and agreement of flow volumes were very good for all software compared to 2D PC (ICC ≥ 0.94; bias ≤ 5%). Internal controls were excellent for 2D PC (r ≥ 0.95, p < 0.001) and 4D flow (r ≥ 0.94, p < 0.001) without significant difference of correlation coefficients between methods. Interobserver reliability was good for all vendors (ICC ≥ 0.94, agreement bias < 8%). CONCLUSION: Haemodynamic information from 4D flow in the large thoracic arteries assessed by four commercially available postprocessing applications matches routinely performed 2D PC values. Therefore, we consider 4D flow MRI-derived data ready for clinical use in patients with CHD.


Assuntos
Cardiopatias Congênitas , Imageamento por Ressonância Magnética , Humanos , Lactente , Pré-Escolar , Criança , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Velocidade do Fluxo Sanguíneo/fisiologia , Aorta/diagnóstico por imagem , Software , Imageamento Tridimensional/métodos
5.
J Pediatr Hematol Oncol ; 44(2): e374-e380, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33828032

RESUMO

OBJECTIVES: Pathologic ejection fraction (EF), shortening fraction (FS), and standard heart failure biomarkers (high sensitive troponin T and N-terminal brain natriuretic peptide) during follow-up after childhood cancer have been associated with irreversible cardiac damage. We aimed to evaluate strain imaging values by echocardiography and new biomarkers for heart failure with preserved ejection fraction (HFpEF) as potential more sensitive parameters for cardiac deterioration in childhood cancer survivors (CCS). MATERIALS AND METHODS: Prospective study with 50 CCS (median 16.2 y) at a median follow-up of 13 years. In addition to standard echo and laboratory parameters for heart failure, strain measurements and new biomarkers, including myocardial inflammation (interleukin 6), extracellular matrix (ECM) remodeling (C-telopeptide for type I collagen, intact N-terminal propeptide of type III procollagen), and other heart failure biomarkers (galectin 3, solutable ST2, growth differentiation factor 15), were obtained and compared with 50 healthy controls. RESULTS: No significant differences in EF, FS, high sensitive troponin T, N-terminal brain natriuretic peptide, interleukin 6, solutable ST2, and galectin 3 were found between study and control groups. In contrast, strain imaging showed significant differences between both groups (global longitudinal strainGLS -16.1% vs. -20.4%, P<0.0001; global circumferential strain -14.3 vs. -21.4%, P<0.0001), detecting 66% (global longitudinal strain) and 76% (global circumferential strain) of patients with pathologic values in contrast to 6% (EF) and 16% (FS) for standard parameters. Markers for disturbances of ECM remodeling (C-telopeptide for type I collagen, intact N-terminal propeptide of type III procollagen, each P<0.0001) and growth differentiation factor 15 (P<0.0001) were significantly different between the groups. CONCLUSION: Strain imaging and new cardiac biomarkers used in HFpEF focusing on ECM remodeling appear to be more sensitive in detecting early remodeling processes in CCS than standard echo and laboratory parameters.


Assuntos
Biomarcadores , Insuficiência Cardíaca , Neoplasias , Criança , Seguimentos , Insuficiência Cardíaca/diagnóstico por imagem , Humanos , Estudos Prospectivos , Volume Sistólico
6.
BMC Med Imaging ; 22(1): 169, 2022 09 27.
Artigo em Inglês | MEDLINE | ID: mdl-36167535

RESUMO

PURPOSE: To find the best level to measure aortic flow for quantification of aortic regurgitation (AR) in 4D flow CMR. METHODS: In 27 congenital heart disease patients with AR (67% male, 31 ± 16 years) two blinded observers measured antegrade, retrograde, net aortic flow volumes and regurgitant fractions at 6 levels in 4D flow: (1) below the aortic valve (AV), (2) at the AV, (3) at the aortic sinus, (4) at the sinotubular junction, (5) at the level of the pulmonary arteries (PA) and (6) below the brachiocephalic trunk. 2D phase contrast (2DPC) sequences were acquired at the level of PA. All patients received prior transthoracic echocardiography (TTE) with AR severity grading according to a recommended multiparametric approach. RESULTS: After assigning 2DPC measurements into AR grading, agreement between TTE AR grading and 2DPC was good (κ = 0.88). In 4D flow, antegrade flow was similar between the six levels (p = 0.87). Net flow was higher at level 1-2 than at levels 3-6 (p < 0.05). Retrograde flow and regurgitant fraction at level 1-2 were lower compared to levels 3-6 (p < 0.05). Reproducibility (inter-reader agreement: ICC 0.993, 95% CI 0.986-0.99; intra-reader agreement: ICC 0.982, 95%CI 0.943-0.994) as well as measurement agreement between 4D flow and 2DPC (ICC 0.994; 95%CI 0.989 - 0.998) was best at the level of PA. CONCLUSION: For estimating severity of AR in 4D flow, best reproducibility along with best agreement with 2DPC measurements can be expected at the level of PA. Measurements at AV or below AV might underestimate AR.


Assuntos
Insuficiência da Valva Aórtica , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico por imagem , Feminino , Humanos , Imagem Cinética por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Masculino , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
7.
Eur Radiol ; 31(10): 7231-7241, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33783570

RESUMO

OBJECTIVES: To use 4D-flow MRI to describe systemic and non-systemic ventricular flow organisation and energy loss in patients with repaired d-transposition of the great arteries (d-TGA) and normal subjects. METHODS: Pathline tracking of ventricular volumes was performed using 4D-flow MRI data from a 1.5-T GE Discovery MR450 scanner. D-TGA patients following arterial switch (n = 17, mean age 14 ± 5 years) and atrial switch (n = 15, 35 ± 6 years) procedures were examined and compared with subjects with normal cardiac anatomy and ventricular function (n = 12, 12 ± 3 years). Pathlines were classified by their passage through the ventricles as direct flow, retained inflow, delayed ejection flow, and residual volume and visually and quantitatively assessed. Additionally, viscous energy losses (ELv) were calculated. RESULTS: In normal subjects, the ventricular flow paths were well ordered following similar trajectories through the ventricles with very little mixing of flow components. The flow paths in all atrial and some arterial switch patients were more irregular with high mixing. Direct flow and delayed ejection flow were decreased in atrial switch patients' systemic ventricles with a corresponding increase in residual volume compared with normal subjects (p = 0.003 and p < 0.001 respectively) and arterial switch patients (p < 0.0001 and p < 0.001 respectively). In non-systemic ventricles, arterial switch patients had increased direct flow and decreased delayed ejection fractions compared to normal (p = 0.007 and p < 0.001 respectively) and atrial switch patients (p = 0.01 and p < 0.001 respectively). Regions of high levels of mixing of ventricular flow components showed elevated ELv. CONCLUSIONS: 4D-flow MRI pathline tracking reveals disordered ventricular flow patterns and associated ELv in d-TGA patients. KEY POINTS: • 4D-flow MRI can be used to assess intraventricular flow dynamics in d-TGA patients. • d-TGA arterial switch patients mostly show intraventricular flow dynamics representative of normal subjects, while atrial switch patients show increased flow disorder and different proportions of intraventricular flow volumes. • Flow disruption and disorder increase viscous energy losses.


Assuntos
Transposição dos Grandes Vasos , Adolescente , Adulto , Artérias , Criança , Átrios do Coração , Ventrículos do Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Transposição dos Grandes Vasos/diagnóstico por imagem , Transposição dos Grandes Vasos/cirurgia , Adulto Jovem
8.
Pediatr Radiol ; 51(8): 1503-1517, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33313980

RESUMO

Cardiovascular MRI has become an essential imaging modality in children with congenital heart disease (CHD) in the last 15-20 years. With use of appropriate sequences, it provides important information on cardiovascular anatomy, blood flow and function for initial diagnosis and post-surgical or -interventional monitoring in children. Although considered as more sophisticated and challenging than CT, in particular in neonates and infants, MRI is able to provide information on intra- and extracardiac haemodynamics, in contrast to CT. In recent years, four-dimensional (4-D) flow MRI has emerged as an additional MR technique for retrospective assessment and visualisation of blood flow within the heart and any vessel of interest within the acquired three-dimensional (3-D) volume. Its application in young children requires special adaptations for the smaller vessel size and faster heart rate compared to adolescents or adults. In this article, we provide an overview of 4-D flow MRI in various types of complex CHD in neonates and infants to demonstrate its potential indications and beneficial application for optimised individual cardiovascular assessment. We focus on its application in clinical routine cardiovascular workup and, in addition, show some examples with pathologies other than CHD to highlight that 4-D flow MRI yields new insights in disease understanding and therapy planning. We shortly review the essentials of 4-D flow data acquisition, pre- and post-processing techniques in neonates, infants and young children. Finally, we conclude with some details on accuracy, limitations and pitfalls of the technique.


Assuntos
Cardiopatias Congênitas , Imageamento por Ressonância Magnética , Adolescente , Adulto , Criança , Pré-Escolar , Coração , Cardiopatias Congênitas/diagnóstico por imagem , Hemodinâmica , Humanos , Lactente , Recém-Nascido , Estudos Retrospectivos
9.
Pediatr Cardiol ; 42(7): 1625-1634, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34313807

RESUMO

Cardiac MR (CMR) is a standard modality for assessing ventricular function of single ventricles. CMR feature-tracking (CMR-FT) is a novel application enabling strain measurement on cine MR images and is used in patients with congenital heart diseases. We sought to assess the feasibility of CMR-FT in Fontan patients and analyze the correlation between CMR-FT strain values and conventional CMR volumetric parameters, clinical findings, and biomarkers. Global circumferential (GCS) and longitudinal (GLS) strain were retrospectively measured by CMR-FT on Steady-State Free Precession cine images. Data regarding post-operative course at Fontan operation, and medication, exercise capacity, invasive hemodynamics, and blood biomarkers at a time interval ± 6 months from CMR were collected. Forty-seven patients underwent CMR 11 ± 6 years after the Fontan operation; age at CMR was 15 ± 7 years. End-diastolic volume (EDV) of the SV was 93 ± 37 ml/m2, end-systolic volume (ESV) was 46 ± 23 ml/m2, and ejection fraction (EF) was 51 ± 11%. Twenty (42%) patients had a single right ventricle (SRV). In single left ventricle (SLV), GCS was higher (p < 0.001), but GLS was lower (p = 0.04) than in SRV. GCS correlated positively with EDV (p = 0.005), ESV (p < 0.001), and EF (p ≤ 0.0001). GLS correlated positively with EF (p = 0.002), but not with ventricular volumes. Impaired GCS correlated with decreased ventricular function (p = 0.03) and atrioventricular valve regurgitation (p = 0.04) at echocardiography, direct atriopulmonary connection (p = 0.02), post-operative complications (p = 0.05), and presence of a rudimentary ventricle (p = 0.01). A reduced GCS was associated with increased NT-pro-BNP (p = 0.05). Myocardial deformation can be measured by CMR-FT in Fontan patients. SLVs have higher GCS, but lower GLS than SRVs. GCS correlates with ventricular volumes and EF, whereas GLS correlates with EF only. Myocardial deformation shows a relationship with several clinical parameters and NT-pro-BNP.


Assuntos
Imagem Cinética por Ressonância Magnética , Miocárdio , Biomarcadores , Ventrículos do Coração/diagnóstico por imagem , Humanos , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Função Ventricular Esquerda
10.
Pediatr Cardiol ; 42(6): 1275-1283, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33900430

RESUMO

Patients after surgical repair of Tetralogy of Fallot (rTOF) may suffer a decrease in left ventricular (LV) function. The aim of our study is to evaluate a novel method of assessing LV torsion in patients with rTOF, as an early indicator of systolic LV dysfunction. Motion tracking based on image registration regularized by the equilibrium gap principle, known as equilibrated warping, was employed to assess LV torsion. Seventy-six cases of rTOF and ten normal controls were included. The group of controls was assessed for reproducibility using both equilibrated warping and standard clinical tissue tracking software (CVI42, version 5.10.1, Calgary, Canada). Patients were dichotomized into two groups: normal vs. loss of torsion. Torsion by equilibrated warping was successfully obtained in 68 of 76 (89%) patients and 9 of 10 (90%) controls. For equilibrated warping, the intra- and interobserver coefficients of variation were 0.095 and 0.117, respectively, compared to 0.260 and 0.831 for tissue tracking by standard clinical software. The intra- and inter-observer intraclass correlation coefficients for equilibrated warping were 0.862 and 0.831, respectively, compared to 0.992 and 0.648 for tissue tracking. Loss of torsion was noted in 32 of the 68 (47%) patients with rTOF. There was no difference in LV or RV volumes or ejection fraction between these groups. The assessment of LV torsion by equilibrated warping is feasible and shows good reliability. Loss of torsion is common in patients with rTOF and its robust assessment might contribute into uncovering heart failure in an earlier stage.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adolescente , Adulto , Estudos de Casos e Controles , Criança , Pré-Escolar , Humanos , Lactente , Complicações Pós-Operatórias/fisiopatologia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Disfunção Ventricular Esquerda/fisiopatologia , Adulto Jovem
11.
Pediatr Cardiol ; 42(3): 578-589, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33394116

RESUMO

Ventricular contouring of cardiac magnetic resonance imaging is the gold standard for volumetric analysis for repaired tetralogy of Fallot (rTOF), but can be time-consuming and subject to variability. A convolutional neural network (CNN) ventricular contouring algorithm was developed to generate contours for mostly structural normal hearts. We aimed to improve this algorithm for use in rTOF and propose a more comprehensive method of evaluating algorithm performance. We evaluated the performance of a ventricular contouring CNN, that was trained on mostly structurally normal hearts, on rTOF patients. We then created an updated CNN by adding rTOF training cases and evaluated the new algorithm's performance generating contours for both the left and right ventricles (LV and RV) on new testing data. Algorithm performance was evaluated with spatial metrics (Dice Similarity Coefficient (DSC), Hausdorff distance, and average Hausdorff distance) and volumetric comparisons (e.g., differences in RV volumes). The original Mostly Structurally Normal (MSN) algorithm was better at contouring the LV than the RV in patients with rTOF. After retraining the algorithm, the new MSN + rTOF algorithm showed improvements for LV epicardial and RV endocardial contours on testing data to which it was naïve (N = 30; e.g., DSC 0.883 vs. 0.905 for LV epicardium at end diastole, p < 0.0001) and improvements in RV end-diastolic volumetrics (median %error 8.1 vs 11.4, p = 0.0022). Even with a small number of cases, CNN-based contouring for rTOF can be improved. This work should be extended to other forms of congenital heart disease with more extreme structural abnormalities. Aspects of this work have already been implemented in clinical practice, representing rapid clinical translation. The combined use of both spatial and volumetric comparisons yielded insights into algorithm errors.


Assuntos
Algoritmos , Ventrículos do Coração/diagnóstico por imagem , Redes Neurais de Computação , Tetralogia de Fallot/diagnóstico por imagem , Adulto , Estudos de Casos e Controles , Feminino , Ventrículos do Coração/anatomia & histologia , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino
12.
Magn Reson Med ; 83(6): 2264-2275, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31742787

RESUMO

PURPOSE: To analyze the dependence of flow volume measurements on 3D cine phase-contrast MRI (4D-flow MRI) background phase correction. METHODS: In 31 subjects scanned on a 1.5T MRI scanner, flow volume measurements at 4 vessels were made using phantom corrected 2D phase contrast and 4D flow with background phase correction performed by linear, second, third, and fourth-order polynomial fitting to static tissue. Variations in the amount and distribution of static tissue were made to investigate the influence on flow volume measurements. RESULTS: Bland Altman comparison of 2D phase-contrast and 4D-flow measurements showed low bias (2.3%-4.8%) and relatively large limits of agreement (13.5%-17.6%). Approximately half of this was attributable to sequence and physiological differences between the 2 scan sequences, demonstrated by smaller limits of agreement (5.3%-10.0%) when comparing 4D-flow measurements with differing background phase corrections. Using only 20% of available static tissue points for polynomial fitting resulted in only 1% difference in flow volume measurements. Using asymmetrically distributed static tissue or including nonstatic tissue for polynomial fitting yielded highly variable differences in flow volume measurements, which became more variable with increased polynomial order. Completely asymmetric static tissue selection resulted in high deviations in flow volume measurements (mean > 7%, max = 345%). CONCLUSION: Comparisons between 2D phase-contrast and 4D-flow volume measurements should consider influences from sequence and physiological differences. A subset of static tissue points may be used with low impact on flow measurements, but should avoid the inclusion of nonstatic tissue and avoid asymmetric distribution. Higher-order polynomial fits are more susceptible to inaccurate static tissue selection.


Assuntos
Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Algoritmos , Velocidade do Fluxo Sanguíneo , Humanos , Imageamento Tridimensional , Imagens de Fantasmas , Reprodutibilidade dos Testes
13.
J Magn Reson Imaging ; 51(3): 897-903, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31507010

RESUMO

BACKGROUND: T1 mapping is useful to quantify diffuse myocardial processes such as fibrosis, edema, storage disorders, or hemochromatosis. Normal pediatric myocardial T1 values are scarce using modified Look-Locker inversion recovery (MOLLI) sequences and unavailable using Smart1Map, a single-point saturation recovery sequence that measures true T1 . PURPOSE/HYPOTHESIS: To establish normal pediatric myocardial T1 values by Smart1Map and to compare them with T1 by MOLLI. STUDY TYPE: Prospective cohort study. SUBJECTS: Thirty-four children and adolescents aged 8-18 years (14 males) without cardiovascular or inflammatory diseases. FIELD STRENGTH/SEQUENCES: 1.5T, MOLLI, Smart1Map. ASSESSMENT: Mean T1 values of the left ventricular myocardium, the interventricular septum, and the blood pool were measured with MOLLI and Smart1Map in basal, mid-ventricular, and apical short axis slices. STATISTICAL TESTS: T1 values were compared between locations and methods by paired samples t-tests, Wilcoxon signed ranks test, repeated-measures analysis of variance (ANOVA), or Friedman's test. Pearson's correlation coefficient was calculated. For interobserver variability, intraclass correlation coefficients and coefficients of variation were calculated, and Bland-Altman analyses were performed. RESULTS: T1 values were longer by Smart1Map than by MOLLI in all measured locations (myocardium: 1191-1221 vs. 990-1042 msec; all P < 0.001). T1 in basal vs. mid-ventricular slices differed both by MOLLI and by Smart1Map for myocardium and for blood (all P < 0.001). Myocardial T1 did not correlate with age, heart rate, right or left ventricular ejection fraction (all P > 0.05) by either method. Septal vs. total myocardial T1 values in each slice did not differ by MOLLI (basal P = 0.371; mid-ventricular P = 0.08; apical P = 0.378) nor by Smart1Map (basal P = 0.056; mid-ventricular P = 0.918; apical P = 0. 392), after artifacts had been carefully excluded. DATA CONCLUSION: We established pediatric normal native T1 values using the Smart1Map sequence and compared the results with T1 mapping with MOLLI. Septal T1 values did not differ from total myocardial T1 values in each of the myocardial slices. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2020;51:897-903.


Assuntos
Imageamento por Ressonância Magnética , Função Ventricular Esquerda , Adolescente , Criança , Humanos , Masculino , Miocárdio , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Volume Sistólico
14.
J Cardiovasc Magn Reson ; 20(1): 76, 2018 11 26.
Artigo em Inglês | MEDLINE | ID: mdl-30474554

RESUMO

BACKGROUND: Volumetric black-blood cardiovascular magnetic resonance (CMR) has been hampered by long scan times and flow sensitivity. The purpose of this study was to assess the feasibility of black-blood, electrocardiogram (ECG)-triggered and respiratory-navigated 3D fast spin echo (3D FSE) for the visualization of the whole heart and great vessels. METHODS: The implemented 3D FSE technique used slice-selective excitation and non-selective refocusing pulses with variable flip angles to achieve constant echo signal for tissue with T1 (880 ms) and T2 (40 ms) similar to the vessel wall. Ten healthy subjects and 21 patients with congenital heart disease (CHD) underwent 3D FSE and conventional 3D balanced steady-state free precession (bSSFP). The sequences were compared in terms of ability to perform segmental assessment, local signal-to-noise ratio (SNRl) and local contrast-to-noise ratio (CNRl). RESULTS: In both healthy subjects and patients with CHD, 3D FSE showed superior pulmonary vein but inferior coronary artery origin visualisation compared to 3D bSFFP. However, in patients with CHD the combination of 3D bSSFP and 3D FSE whole-heart imaging improves the success rate of cardiac morphological diagnosis to 100% compared to either technique in isolation (3D FSE, 23.8% success rate, 3D bSSFP, 5% success rate). In the healthy subjects SNRl for 3D bSSFP was greater than for 3D FSE (30.1 ± 7.3 vs 20.9 ± 5.3; P = 0.002) whereas the CNRl was comparable (17.3 ± 5.6 vs 17.4 ± 4.9; P = 0.91) between the two scans. CONCLUSIONS: The feasibility of 3D FSE for whole-heart black-blood CMR imaging has been demonstrated. Due to their high success rate for segmental assessment, the combination of 3D bSSFP and 3D FSE may be an attractive alternative to gadolinium contrast enhanced morphological CMR in patients with CHD.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca , Cardiopatias Congênitas/diagnóstico por imagem , Coração/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Estudos de Casos e Controles , Criança , Circulação Coronária , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Eletrocardiografia , Estudos de Viabilidade , Feminino , Coração/fisiopatologia , Cardiopatias Congênitas/fisiopatologia , Frequência Cardíaca , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Circulação Pulmonar , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Adulto Jovem
15.
Xenotransplantation ; 24(6)2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28940406

RESUMO

BACKGROUND: The reconstruction of heart valves provides substantial benefits, particularly in the pediatric population. We present our experience using decellularized extracellular matrix (dECM, CorMatrix® ) for aortic valve procedures. METHODS: We retrospectively reviewed the case histories of 6 patients (aged from 2 months - 14 years) who underwent surgery for severe aortic valve stenosis (n = 4) or regurgitation (n = 2). Aortic valve repair was performed on all patients using dECM as a leaflet replacement or leaflet extension. Follow-ups were performed using echocardiography. Reoperation was necessary in 4 cases, and the dECM was explanted and examined histologically and immunohistochemically. RESULTS: The early post-operative period was uneventful, and the scaffold fulfilled the mechanical requirements. Significant valve insufficiency developed in 5 patients during the post-operative period (119-441 days postoperatively). In all specimens, only a migration of inflammatory cells was identified, which induced structural and functional changes caused by the chronic inflammatory response. CONCLUSIONS: Our results suggest a mixed immunological response of remodeling and inflammation following the implantation. The expected process of seeding/migration and remodeling of the bioscaffold into the typical 3-layered architecture were not observed in our explanted specimens.


Assuntos
Valva Aórtica/cirurgia , Procedimentos Cirúrgicos Cardíacos , Transplante Heterólogo , Resultado do Tratamento , Adolescente , Animais , Valva Aórtica/transplante , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Inflamação/etiologia , Masculino , Reoperação , Estudos Retrospectivos , Transplante Heterólogo/efeitos adversos
16.
Pediatr Radiol ; 47(2): 169-177, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27966039

RESUMO

BACKGROUND: Echocardiographic examinations have revealed functional cardiac abnormalities in children with chronic kidney disease. OBJECTIVE: To assess the feasibility of MRI tissue phase mapping in children and to assess regional left ventricular wall movements in children with chronic kidney disease. MATERIALS AND METHODS: Twenty pediatric patients with chronic kidney disease (before or after renal transplantation) and 12 healthy controls underwent tissue phase mapping (TPM) to quantify regional left ventricular function through myocardial long (Vz) and short-axis (Vr) velocities at all 3 levels of the left ventricle. RESULTS: Patients and controls (age: 8 years-20 years) were matched for age, height, weight, gender and heart rate. Patients had higher systolic blood pressure. No patient had left ventricular hypertrophy on MRI or diastolic dysfunction on echocardiography. Fifteen patients underwent tissue Doppler echocardiography, with normal z-scores for mitral early diastolic (VE), late diastolic (VA) and peak systolic (VS) velocities. Throughout all left ventricular levels, peak diastolic Vz and Vr (cm/s) were reduced in patients: Vzbase -10.6 ± 1.9 vs. -13.4 ± 2.0 (P < 0.0003), Vzmid -7.8 ± 1.6 vs. -11 ± 1.5 (P < 0.0001), Vzapex -3.8 ± 1.6 vs. -5.3 ± 1.6 (P = 0.01), Vrbase -4.2 ± 0.8 vs. -4.9 ± 0.7 (P = 0.01), Vrmid -4.7 ± 0.7 vs. -5.4 ± 0.7 (P = 0.01), Vrapex -4.7 ± 1.4 vs. -5.6 ± 1.1 (P = 0.05). CONCLUSION: Tissue phase mapping is feasible in children and adolescents. Children with chronic kidney disease show significantly reduced peak diastolic long- and short-axis left ventricular wall velocities, reflecting impaired early diastolic filling. Thus, tissue phase mapping detects chronic kidney disease-related functional myocardial changes before overt left ventricular hypertrophy or echocardiographic diastolic dysfunction occurs.


Assuntos
Insuficiência Renal Crônica/complicações , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia , Adolescente , Estudos de Casos e Controles , Criança , Ecocardiografia Doppler , Feminino , Humanos , Transplante de Rim , Masculino , Insuficiência Renal Crônica/cirurgia , Adulto Jovem
18.
Cochrane Database Syst Rev ; (3): CD009515, 2015 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-25806562

RESUMO

BACKGROUND: Children with congenital heart disease often undergo heart surgery at a young age. They are at risk for postoperative low cardiac output syndrome (LCOS) or death. Milrinone may be used to provide inotropic and vasodilatory support during the immediate postoperative period. OBJECTIVES: This review examines the effectiveness of prophylactic postoperative use of milrinone to prevent LCOS or death in children having undergone surgery for congenital heart disease. SEARCH METHODS: Electronic and manual literature searches were performed to identify randomised controlled trials. We searched CENTRAL, MEDLINE, EMBASE and Web of Science in February 2014 and conducted a top-up search in September 2014 as well as clinical trial registries and reference lists of published studies. We did not apply any language restrictions. SELECTION CRITERIA: Only randomised controlled trials were selected for analysis. We considered studies with newborn infants, infants, toddlers, and children up to 12 years of age. DATA COLLECTION AND ANALYSIS: Two review authors independently extracted data according to a pre-defined protocol. We obtained additional information from all study authors. MAIN RESULTS: Three of the five included studies compared milrinone versus levosimendan, one study compared milrinone with placebo, and one compared milrinone verus dobutamine, with 101, 242, and 50 participants, respectively. Three trials were at low risk of bias while two were at higher risk of bias. The number and definitions of outcomes were non-uniform as well. In one study comparing two doses of milrinone and placebo, there was some evidence in an overall comparison of milrinone versus placebo that milrinone lowered risk for LCOS (risk ratio (RR) 0.52, 95% confidence interval (CI) 0.28 to 0.96; 227 participants). The results from two small studies do not provide enough information to determine whether milrinone increases the risk of LCOS when compared to levosimendan (RR 1.22, 95% CI 0.32 to 4.65; 59 participants). Mortality rates in the studies were low, and there was insufficient evidence to draw conclusions on the effect of milrinone compared to placebo or levosimendan or dobutamine regarding mortality, the duration of intensive care stay, hospital stay, mechanical ventilation, or maximum inotrope score (where available). Numbers of patients requiring mechanical cardiac support were also low and did not allow a comparison between studies, and none of the participants of any study received a heart transplantation up to the end of the respective follow-up period. Time to death within three months was not reported in any of the included studies. A number of adverse events was examined, but differences between the treatment groups could not be proven for hypotension, intraventricular haemorrhage, hypokalaemia, bronchospasm, elevated serum levels of liver enzymes, or a reduced left ventricular ejection fraction < 50% or reduced left ventricular fraction of shortening < 28%. Our analysis did not prove an increased risk of arrhythmias in patients treated prophylactically with milrinone compared with placebo (RR 3.59, 95% CI 0.83 to 15.42; 238 participants), a decreased risk of pleural effusions (RR 1.78, 95% CI 0.92 to 3.42; 231 participants), or a difference in risk of thrombocytopenia on milrinone compared with placebo (RR 0.86, 95% CI 0.39 to 1.88; 238 participants). Comparisons of milrinone with levosimendan or with dobutamine, respectively, did not clarify the risk of arrhythmia and were not possible for pleural effusions or thrombocytopenia. AUTHORS' CONCLUSIONS: There is insufficient evidence of the effectiveness of prophylactic milrinone in preventing death or low cardiac output syndrome in children undergoing surgery for congenital heart disease, compared to placebo. So far, no differences have been shown between milrinone and other inodilators, such as levosimendan or dobutamine, in the immediate postoperative period, in reducing the risk of LCOS or death. The existing data on the prophylactic use of milrinone has to be viewed cautiously due to the small number of small trials and their risk of bias.


Assuntos
Baixo Débito Cardíaco/prevenção & controle , Cardiotônicos/uso terapêutico , Cardiopatias Congênitas/cirurgia , Milrinona/uso terapêutico , Complicações Pós-Operatórias/prevenção & controle , Baixo Débito Cardíaco/etiologia , Baixo Débito Cardíaco/mortalidade , Cardiotônicos/efeitos adversos , Dobutamina/uso terapêutico , Cardiopatias Congênitas/mortalidade , Humanos , Hidrazonas/uso terapêutico , Lactente , Recém-Nascido , Milrinona/efeitos adversos , Complicações Pós-Operatórias/mortalidade , Piridazinas/uso terapêutico , Ensaios Clínicos Controlados Aleatórios como Assunto , Simendana , Síndrome , Fatores de Tempo
19.
Catheter Cardiovasc Interv ; 84(5): 820-3, 2014 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-24905182

RESUMO

A very low birth weight neonate (1.2 kg) with total anomalous pulmonary venous connection and obstructed infracardiac pulmonary venous drainage was treated by stenting of the ductus venosus via a transjugular approach. With one reintervention to dilate an in-stent stenosis, the palliative stented situation stabilized the patient for as long as three months until definitive surgical correction at a weight of 2 kg. © 2014 Wiley Periodicals, Inc.


Assuntos
Recém-Nascido de muito Baixo Peso , Cuidados Paliativos/métodos , Veias Pulmonares/anormalidades , Síndrome de Cimitarra/terapia , Stents , Anormalidades Múltiplas/diagnóstico , Anormalidades Múltiplas/cirurgia , Cateterismo Cardíaco/métodos , Constrição Patológica/terapia , Diafragma/anormalidades , Tratamento de Emergência/métodos , Feminino , Seguimentos , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/cirurgia , Humanos , Recém-Nascido , Medição de Risco , Síndrome de Cimitarra/diagnóstico por imagem , Resultado do Tratamento , Ultrassonografia
20.
Eur J Pediatr ; 173(12): 1703-5, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24844353

RESUMO

UNLABELLED: Direct communication between the right pulmonary artery (RPA) and the left atrium (LA) is a very rare cardiac malformation. Clinical presentation of RPA-to-LA communication depends on the size of the communication, the amount of right-to-left shunt, the patient's age, and pulmonary vascular resistance. Patients with small communications usually present oligosymptomatic and are diagnosed at an older age. A delay of diagnosis bears the risk of severe complications and needs to be prevented by proper work-up of oligosymptomatic neonates. Treatment of RPA-to-LA communications used to be performed by surgical closure, and the interventional approach has only been established as a less invasive alternative in recent years. CONCLUSION: Although patients with small RPA-to-LA communications usually present oligosymptomatic, early diagnosis and treatment is essential to prevent life-threatening complications.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Diagnóstico Precoce , Átrios do Coração/anormalidades , Cardiopatias Congênitas/cirurgia , Doenças do Prematuro/cirurgia , Artéria Pulmonar/anormalidades , Fístula Vascular/cirurgia , Angiografia , Cateterismo Cardíaco , Ecocardiografia Doppler em Cores , Seguimentos , Átrios do Coração/cirurgia , Cardiopatias Congênitas/diagnóstico , Humanos , Recém-Nascido , Doenças do Prematuro/diagnóstico , Masculino , Artéria Pulmonar/cirurgia , Fístula Vascular/congênito , Fístula Vascular/diagnóstico , Procedimentos Cirúrgicos Vasculares/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA