Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Magn Reson Imaging ; 2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39212126

RESUMO

BACKGROUND: Skeletal muscle mitochondrial oxidative phosphorylation (mtOXPHOS) is important for ATP generation and its dysfunction leads to exercise intolerance. Phosphorus magnetic resonance spectroscopy (31P-MRS) is a useful, noninvasive technique for mtOXPHOS assessment but has limitations. Creatine-weighted chemical exchange saturation transfer (CrCEST) MRI is a potential alternative to assess muscle bioenergetics. PURPOSE: To evaluate the interscan repeatability, intra- and interobserver reproducibility of CrCEST during mild plantar flexion exercise. STUDY TYPE: Retrospective. SUBJECTS: Twenty healthy volunteers (age 37.6 ± 12.4 years, 11 females). FIELD STRENGTH/SEQUENCE: 3 T/CEST imaging using gradient echo readout. ASSESSMENT: τCrCEST (postexercise Cr recovery time) was assessed in two scans for each participant, following mild plantar flexion exercises targeting the medial gastrocnemius (MG), lateral gastrocnemius (LG), and soleus (Sol) muscles. Three observers measured τCrCEST for interobserver reproducibility. Three readings by one observer were used to measure intraobserver reproducibility. Two scans were used for within-participant interscan repeatability. STATISTICAL TESTS: Paired t tests, intraclass correlation coefficient (ICC), and Pearson correlation were conducted. Bland-Altman plots were used to analyze the interobserver variability. A P-value of 0.05 was considered statistically significant. RESULTS: There was excellent intra- (ICC ∈ 0.94 - 0.98 $$ \in \left[0.94-0.98\right] $$ ) and interobserver (ICC ∈ 0.9 - 0.98 $$ \in \left[0.9-0.98\right] $$ ) reproducibility, with moderate interscan repeatability for τCrCEST in LG and MG (ICC ∈ 0.54 - 0.74 $$ \in \left[0.54-0.74\right] $$ ) and poor-to-moderate interscan repeatability in Sol (ICC ∈ 0.24 - 0.53 $$ \in \left[0.24-0.53\right] $$ ). Excellent interobserver reproducibility was confirmed by Bland-Altman plots (fixed bias P-value ∈ 0.08 - 0.87 $$ \in \left[0.08-0.87\right] $$ ). DATA CONCLUSION: CrCEST MRI shows promise in assessing muscle bioenergetics by evaluating τCrCEST during mild plantar flexion exercise with reasonable reliability, particularly in LG and MG. LEVEL OF EVIDENCE: 4 TECHNICAL EFFICACY: Stage 1.

2.
J Sleep Res ; 33(1): e14029, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37734843

RESUMO

Clearance of brain toxins occurs during sleep, although the mechanism remains unknown. Previous studies implied that the intracranial aqueductal cerebrospinal fluid (CSF) oscillations are involved, but no mechanism was suggested. The rationale for focusing on the aqueductal CSF oscillations is unclear. This study focuses on the cranio-spinal CSF oscillation and the factors that modulate this flow. We propose a mechanism where increased cranio-spinal CSF movements enhance CSF-to-blood metabolic waste clearance through the spinal CSF re-absorption sites. A recent study demonstrating that disturbed sleep impairs CSF-to-blood but not brain-to-CSF clearance, supports the fundamentals of our proposed mechanism. Eight healthy subjects underwent phase-contrast magnetic resonance imaging to quantify the effect of respiration on the cranio-spinal CSF oscillations. Maximal CSF volume displaced from the cranium to the spinal canal during each respiration and cardiac cycle were derived as measures of cranio-spinal CSF mixing level. Transition from normal to slow and abdominal breathing resulted in a 56% increase in the maximal displaced CSF volume. Maximal change in the arterial-venous blood volume, which is the driving force of the CSF oscillations, was increased by 41% during slow abdominal breathing. Cranio-spinal CSF oscillations are driven by the momentary difference between arterial inflow and venous outflow. Breathing modulates the CSF oscillation through changes in the venous outflow. The amount of toxins being transferred to the spinal canal during each respiratory cycle is significantly increased during slow and deeper abdominal breathing, which explains enhanced CSF-to-blood toxins clearance during slow-wave sleep and poor clearance during disrupted sleep.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Humanos , Respiração
3.
J Magn Reson Imaging ; 54(1): 206-214, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33491833

RESUMO

Mechanical compliance of a compartment is defined by the change in its volume with respect to a change in the inside pressure. The compliance of the spinal canal regulates the intracranial pressure (ICP) under postural changes. Understanding how gravity affects ICP is beneficial for poorly understood cerebrospinal fluid (CSF)-related disorders. The aim of this study was to evaluate postural effects on cranial hemo- and hydrodynamics. This was a prospective study, which included 10 healthy volunteers (three males, seven females, mean ± standard deviation age: 29 ± 7 years). Cine gradient-echo phase-contrast sequence acquired at 0.5 T, "GE double-doughnut" scanner was used. Spinal contribution to overall craniospinal compliance (CSC), craniospinal CSF stroke volume (SV), magnetic resonance (MR)-derived ICP (MR-ICP), and total cerebral blood flow (TCBF) were measured in supine and upright postures using automated blood and CSF flows quantification. Statistical tests performed were two-sided Student's t-test, Cohen's d, and Pearson correlation coefficient. MR-ICP and the craniospinal CSF SV were significantly correlated with the spinal contribution to the overall CSC (r = 0.83, p < 0.05) and (r = 0.62, p < 0.05), respectively. Cranial contribution to CSC increased from 44.5% ± 16% in supine to 74.9% ± 8.4% in upright posture. The average MR-ICP dropped from 9.9 ± 3.4 mmHg in supine to -3.5 ± 1.5 mmHg. The CSF SV was over 2.5 times higher in the supine position (0.55 ± 0.14 ml) than in the upright position (0.21 ± 0.13 ml). In contrast, TCBF was slightly higher in the supine posture (822 ± 152 ml/min) than in the upright posture (761 ± 139 ml/min), although not statistically significant (p = 0.16). The spinal-canal compliance contribution to CSC is larger than the cranial contribution in the supine posture and smaller in the upright posture. Thereby, the spinal canal plays a role in modulating ICP upon postural changes. The lower pressure craniospinal CSF system was more affected by postural changes than the higher-pressure cerebral vascular system. Craniospinal hydrodynamics is affected by gravity and is likely to be altered by its absence in space. LEVEL OF EVIDENCE: 4 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Hidrodinâmica , Pressão Intracraniana , Adulto , Líquido Cefalorraquidiano , Feminino , Humanos , Masculino , Postura , Estudos Prospectivos , Canal Medular/diagnóstico por imagem , Adulto Jovem
4.
J Magn Reson Imaging ; 50(3): 975-981, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-30801895

RESUMO

BACKGROUND: Intracranial pressure (ICP) is an important physiological parameter in several neurological disorders. Considerable effort has been made to measure ICP noninvasively. MR-based ICP (MR-ICP) is a nonempirical method based on principles of cerebrospinal fluid (CSF) physiology, where ICP is obtained from measurements of blood and CSF flows to and from the cranium during the cardiac cycle. PURPOSE: To compare MR-ICP with invasive ICP measurements obtained using lumbar puncture (LP) or external ventricular drainage (EVD). STUDY TYPE: Prospective, cross-sectional, observational study. SUBJECTS: Ten cognitively healthy elderly subjects (age 69.6 ± 6.6 years; seven females) and six brain trauma patients (age 36.8 ± 19.7 years; two females). FIELD STRENGTH: Velocity encoding cine phase-contrast at 1.5 T and 3 T. ASSESSMENT: MR-ICP and craniospinal compliance distribution were estimated from arterial inflow and venous outflow to and from cranium, and craniospinal CSF flow at the upper cervical region, measured using cine phase contrast MRI. LP (done 177 ± 163 days after scan) and EVD measurements (at the time of scan) were performed in lateral recumbent and supine positions, respectively. STATISTICAL TESTS: Linear regression was used to assess the relationships of MR-ICP with invasive ICP, and the dependency of these measurements on age, weight, height, and BMI. A Shapiro-Wilks test and Bland-Altman plot were respectively used to evaluate the normality and agreement between these two pressure distributions. Student's t-test was used throughout the analysis to compare differences between the EVD and LP cohorts. RESULTS: In the combined cohort, MR-ICP and invasive ICP were positively correlated (r = 0.95, P < 0.001), with invasive ICP being higher than MR-ICP by 2.2 mmHg on average. In the healthy cohort, the cranial contribution to total craniospinal compliance was negatively correlated with MR-ICP (r = -0.90, P < 0.001). DATA CONCLUSION: MR-ICP provides a reliable estimate of ICP, with 14 out of 16 datapoints within the clinically acceptable error. Craniospinal compliance distribution plays a role in modulating ICP in supine position. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;50:975-981.


Assuntos
Lesões Encefálicas Traumáticas/diagnóstico por imagem , Lesões Encefálicas Traumáticas/fisiopatologia , Pressão Intracraniana/fisiologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Encéfalo/diagnóstico por imagem , Encéfalo/fisiopatologia , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Reprodutibilidade dos Testes , Adulto Jovem
5.
Fluids Barriers CNS ; 15(1): 29, 2018 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-30428887

RESUMO

BACKGROUND: The distribution of cranio-spinal compliance (CSC) in the brain and spinal cord is a fundamental question, as it would determine the overall role of the compartments in modulating ICP in healthy and diseased states. Invasive methods for measurement of CSC using infusion-based techniques provide overall CSC estimate, but not the individual sub-compartmental contribution. Additionally, the outcome of the infusion-based method depends on the infusion site and dynamics. This article presents a method to determine compliance distribution between the cranium and spinal canal non-invasively using data obtained from patients. We hypothesize that this CSC distribution is indicative of the ICP. METHODS: We propose a lumped-parameter model representing the hydro and hemodynamics of the cranio-spinal system. The input and output to the model are phase-contrast MRI derived volumetric transcranial blood flow measured in vivo, and CSF flow at the spinal cervical level, respectively. The novelty of the method lies in the model mathematics that predicts CSC distribution (that obeys the physical laws) from the system dc gain of the discrete-domain transfer function. 104 healthy individuals (48 males, 56 females, age 25.4 ± 14.9 years, range 3-60 years) without any history of neurological diseases, were used in the study. Non-invasive MR assisted estimate of ICP was calculated and compared with the cranial compliance to prove our hypothesis. RESULTS: A significant negative correlation was found between model-predicted cranial contribution to CSC and MR-ICP. The spinal canal provided majority of the compliance in all the age groups up to 40 years. However, no single sub-compartment provided majority of the compliance in 41-60 years age group. The cranial contribution to CSC and MR-ICP were significantly correlated with age, with gender not affecting the compliance distribution. Spinal contribution to CSC significantly positively correlated with CSF stroke volume. CONCLUSIONS: This paper describes MRI-based non-invasive way to determine the cranio-spinal compliance distribution in the brain and spinal canal sub-compartments. The proposed mathematics makes the model always stable and within the physiological range. The model-derived cranial compliance was strongly negatively correlated to non-invasive MR-ICP data from 104 patients, indicating that compliance distribution plays a major role in modulating ICP.


Assuntos
Complacência (Medida de Distensibilidade) , Modelos Neurológicos , Crânio/fisiologia , Canal Medular/fisiologia , Adolescente , Adulto , Encéfalo/irrigação sanguínea , Encéfalo/fisiologia , Criança , Pré-Escolar , Feminino , Hemodinâmica , Humanos , Hidrodinâmica , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Crânio/irrigação sanguínea , Canal Medular/irrigação sanguínea , Medula Espinal/irrigação sanguínea , Medula Espinal/fisiologia , Adulto Jovem
6.
J Ophthalmol ; 2015: 180972, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26688751

RESUMO

Glaucoma is the second leading cause of loss of vision in the world. Examining the head of optic nerve (cup-to-disc ratio) is very important for diagnosing glaucoma and for patient monitoring after diagnosis. Images of optic disc and optic cup are acquired by fundus camera as well as Optical Coherence Tomography. The optic disc and optic cup segmentation techniques are used to isolate the relevant parts of the retinal image and to calculate the cup-to-disc ratio. The main objective of this paper is to review segmentation methodologies and techniques for the disc and cup boundaries which are utilized to calculate the disc and cup geometrical parameters automatically and accurately to help the professionals in the glaucoma to have a wide view and more details about the optic nerve head structure using retinal fundus images. We provide a brief description of each technique, highlighting its classification and performance metrics. The current and future research directions are summarized and discussed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA