Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
1.
Int J Obes (Lond) ; 47(4): 306-312, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36750691

RESUMO

BACKGROUND/OBJECTIVES: To evaluate anthropometric measures for the prediction of whole-abdominal adipose tissue volumes VXAT (subcutaneous VSAT, visceral VVAT and total VTAT) in patients with obesity. SUBJECTS/METHODS: A total of 181 patients (108 women) with overweight or obesity were analyzed retrospectively. MRI data (1.5 T) were available from independent clinical trials at a single institution (Integrated Research and Treatment Center of Obesity, University of Leipzig). A custom-made software was used for automated tissue segmentation. Anthropometric parameters (AP) were circumferences of the waist (WC) and hip (HC), waist-to-hip ratio (WHR), waist-to-height ratio (WHtR) and the (hypothetical) hip-to-height ratio (HHtR). Agreement was evaluated by standard deviations sd% of percent differences between estimated volumes (using results of linear AP-VXAT regression) and measured ones as well as Pearson's correlation coefficient r. RESULTS: For SAT volume estimation, the smallest sd% for all patients was seen for HC (25.1%) closely followed by HHtR (25.2%). Sex-specific results for females (17.5% for BMI and 17.2% for HC) and males (20.7% for WC) agreed better. VAT volumes could not be estimated reliably by any of the anthropometric measures considered here. TAT volumes in a mixed population could be best estimated by BMI closely followed by WC (roughly 17.5%). A sex-specific consideration reduced the deviations to around 16% for females (BMI and WC) and below 14% for males (WC). CONCLUSIONS: We suggest the use of sex-specific parameters-BMI or HC for females and WC for males-for the estimation of abdominal SAT and TAT volumes in patients with overweight or obesity.


Assuntos
Obesidade , Sobrepeso , Masculino , Humanos , Adulto , Feminino , Estudos Retrospectivos , Índice de Massa Corporal , Obesidade/epidemiologia , Gordura Abdominal/diagnóstico por imagem , Relação Cintura-Quadril , Razão Cintura-Estatura , Circunferência da Cintura , Obesidade Abdominal , Fatores de Risco
2.
Eur Radiol ; 33(12): 8957-8964, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37436508

RESUMO

OBJECTIVES: To present software for automated adipose tissue quantification of abdominal magnetic resonance imaging (MRI) data using fully convolutional networks (FCN) and to evaluate its overall performance-accuracy, reliability, processing effort, and time-in comparison with an interactive reference method. MATERIALS AND METHODS: Single-center data of patients with obesity were analyzed retrospectively with institutional review board approval. Ground truth for subcutaneous (SAT) and visceral adipose tissue (VAT) segmentation was provided by semiautomated region-of-interest (ROI) histogram thresholding of 331 full abdominal image series. Automated analyses were implemented using UNet-based FCN architectures and data augmentation techniques. Cross-validation was performed on hold-out data using standard similarity and error measures. RESULTS: The FCN models reached Dice coefficients of up to 0.954 for SAT and 0.889 for VAT segmentation during cross-validation. Volumetric SAT (VAT) assessment resulted in a Pearson correlation coefficient of 0.999 (0.997), relative bias of 0.7% (0.8%), and standard deviation of 1.2% (3.1%). Intraclass correlation (coefficient of variation) within the same cohort was 0.999 (1.4%) for SAT and 0.996 (3.1%) for VAT. CONCLUSION: The presented methods for automated adipose-tissue quantification showed substantial improvements over common semiautomated approaches (no reader dependence, less effort) and thus provide a promising option for adipose tissue quantification. CLINICAL RELEVANCE STATEMENT: Deep learning techniques will likely enable image-based body composition analyses on a routine basis. The presented fully convolutional network models are well suited for full abdominopelvic adipose tissue quantification in patients with obesity. KEY POINTS: • This work compared the performance of different deep-learning approaches for adipose tissue quantification in patients with obesity. • Supervised deep learning-based methods using fully convolutional networks  were suited best. • Measures of accuracy were equal to or better than the operator-driven approach.


Assuntos
Gordura Abdominal , Gordura Intra-Abdominal , Humanos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Gordura Abdominal/diagnóstico por imagem , Gordura Abdominal/patologia , Gordura Intra-Abdominal/diagnóstico por imagem , Obesidade/diagnóstico por imagem , Obesidade/patologia , Imageamento por Ressonância Magnética/métodos , Gordura Subcutânea
3.
Eur Radiol ; 33(3): 2128-2135, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36307555

RESUMO

OBJECTIVES: The breathing phase for the determination of thoracic indices in patients with pectus excavatum is not standardized. The aim of this study was to identify the best period for reliable assessments of morphologic indices by dynamic observations of the chest wall using real-time MRI. METHODS: In this prospective study, patients with pectus excavatum underwent morphologic evaluation by real-time MRI at 3 T between January 2020 and June 2021. The Haller index (HI), correction index (CI), modified asymmetry index (AI), and modified eccentricity index (EI) were determined during free, quiet, and forced breathing respectively. Breathing-related differences in the thoracic indices were analyzed with the Wilcoxon signed-rank test. Motion of the anterior chest wall was analyzed as well. RESULTS: A total of 56 patients (11 females and 45 males, median age 15.4 years, interquartile range 14.3-16.9) were included. In quiet expiration, the median HI in the cohort equaled 5.7 (4.5-7.2). The median absolute differences (Δ) in the thoracic indices between peak inspiration and peak expiration were ΔHI = 1.1 (0.7-1.6, p < .001), ΔCI = 4.8% (1.3-7.5%, p < .001), ΔAI = 3.0% (1.0-5.0%, p < .001), and ΔEI = 8.0% (3.0-14.0%, p < .05). The indices varied significantly during different inspiratory phases, but not during expiration (p > .05 each). Furthermore, the dynamic evaluation revealed three distinctive movement patterns of the funnel chest. CONCLUSIONS: Real-time MRI reveals patterns of chest wall motion and indicate that thoracic indices of pectus excavatum should be assessed in the end-expiratory phase of quiet expiration. KEY POINTS: • The thoracic indices in patients with pectus excavatum depend on the breathing phase. • Quiet expiration represents the best breathing phase for determining thoracic indices. • Real-time MRI can identify different chest wall motion patterns in pectus excavatum.


Assuntos
Tórax em Funil , Masculino , Feminino , Humanos , Adolescente , Tórax em Funil/diagnóstico por imagem , Estudos Prospectivos , Tórax , Imageamento por Ressonância Magnética , Movimento (Física)
4.
Eur Radiol ; 30(2): 934-942, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31471752

RESUMO

OBJECTIVES: To evaluate the accuracy and clinical integrability of a comprehensive simulation tool to plan and predict radiofrequency ablation (RFA) zones in liver tumors. METHODS: Forty-five patients with 51 malignant hepatic lesions of different origins were included in a prospective multicenter trial. Prior to CT-guided RFA, all patients underwent multiphase CT which included acquisitions for the assessment of liver perfusion. These data were used to generate a 3D model of the liver. The intra-procedural position of the RFA probe was determined by CT and semi-automatically registered to the 3D model. Size and shape of the simulated ablation zones were compared with those of the thermal ablation zones segmented in contrast-enhanced CT images 1 month after RFA; procedure time was compared with a historical control group. RESULTS: Simulated and segmented ablation zone volumes showed a significant correlation (ρ = 0.59, p < 0.0001) and no significant bias (Wilcoxon's Z = 0.68, p = 0.25). Representative measures of ablation zone comparison were as follows: average surface deviation (absolute average error, AAE) with 3.4 ± 1.7 mm, Dice similarity coefficient 0.62 ± 0.14, sensitivity 0.70 ± 0.21, and positive predictive value 0.66 ± 0. There was a moderate positive correlation between AAE and duration of the ablation (∆t; r = 0.37, p = 0.008). After adjustments for inter-individual differences in ∆t, liver perfusion, and prior transarterial chemoembolization procedures, ∆t was an independent predictor of AAE (ß = 0.03 mm/min, p = 0.01). Compared with a historical control group, the simulation added 3.5 ± 1.9 min to the procedure. CONCLUSION: The validated simulation tool showed acceptable speed and accuracy in predicting the size and shape of hepatic RFA ablation zones. Further randomized controlled trials are needed to evaluate to what extent this tool might improve patient outcomes. KEY POINTS: • More reliable, patient-specific intra-procedural estimation of the induced RFA ablation zones in the liver may lead to better planning of the safety margins around tumors. • Dedicated real-time simulation software to predict RFA-induced ablation zones in patients with liver malignancies has shown acceptable agreement with the follow-up results in a first prospective multicenter trial suggesting a randomized controlled clinical trial to evaluate potential outcome benefit for patients.


Assuntos
Carcinoma Hepatocelular/cirurgia , Ablação por Cateter/métodos , Neoplasias Hepáticas/cirurgia , Adolescente , Adulto , Idoso , Carcinoma Hepatocelular/patologia , Quimioembolização Terapêutica/métodos , Simulação por Computador , Feminino , Humanos , Fígado/patologia , Fígado/cirurgia , Neoplasias Hepáticas/patologia , Masculino , Margens de Excisão , Pessoa de Meia-Idade , Planejamento de Assistência ao Paciente , Estudos Prospectivos , Tomografia Computadorizada por Raios X , Adulto Jovem
5.
MAGMA ; 32(5): 599-605, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31073867

RESUMO

PURPOSE: To evaluate the technical and clinical utility of a fully MRI-compatible, pneumatically driven remote-controlled manipulator (RCM) for targeted biopsies of the prostate at 1.5 T. MATERIALS AND METHODS: The data of the first 22 patients that were biopsied under robotic assistance were analyzed. Interventional planning relied on T2-weighted (T2w) turbo spin-echo (TSE) images (axial and sagittal) with a high-b-value diffusion-weighted acquisition added in selected cases. Alignment of the needle guide was controlled with a short balanced SSFP sequence in two oblique planes along the MR-visible sheath. Signals were acquired with a combination of elements from a 30-channel body and a 32-channel spine coil. Biopsy samples were taken with a fully automatic 18-G biopsy gun with a length of 150 or 175 mm. RESULTS: Mean age was 66.6 years and average PSA level was 11.5 ng/ml. Fourteen out of 22 patients (63%) had received prior biopsies under transrectal ultrasound guidance. Diagnostic MRI reports (before biopsy) involved 17 cases with a single suspicious finding (four PI-RADS 3, one PI-RADS 3-4, eight PI-RADS 4 and nine PI-RADS 5 cases). The median effective procedure time was 33.9 (range 25.0-55.9) min for 16 cases with one CSR and 63.4 (52.7-81.8) min for 5 cases with two CSRs. The biopsy with three CSRs took 74.0 min. Histopathologic examination revealed prostate cancer in 14 of 22 cases. CONCLUSION: MR-targeted, transrectal biopsy of the prostate could be reliably performed with a robotic manipulator at a field strength of 1.5 T. Balanced SSFP imaging is considered a viable option for fast procedural control. Follow-up work needs to evaluate to what extent in-bore adjustments and workflow enhancements will contribute to shorter procedure times or higher patient comfort.


Assuntos
Biópsia/métodos , Imagem por Ressonância Magnética Intervencionista , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Procedimentos Cirúrgicos Robóticos/métodos , Idoso , Imagem de Difusão por Ressonância Magnética , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Reconhecimento Automatizado de Padrão , Próstata/patologia , Neoplasias da Próstata/patologia , Estudos Retrospectivos , Robótica
6.
BMC Med Imaging ; 19(1): 80, 2019 10 22.
Artigo em Inglês | MEDLINE | ID: mdl-31640589

RESUMO

BACKGROUND: The purpose of this study was to determine to what extent the whole volumes of abdominal subcutaneous (ASAT) and visceral adipose tissue (VAT) of patients with obesity can be predicted by using data of one body half only. Such a workaround has already been reported for dual-energy x-ray absorption (DEXA) scans and becomes feasible whenever the field of view of an imaging technique is not large enough. METHODS: Full-body abdominal MRI data of 26 patients from an obesity treatment center (13 females and 13 males, BMI range 30.8-41.2 kg/m2, 32.6-61.5 years old) were used as reference (REF). MRI was performed with IRB approval on a clinical 1.5 T MRI (Achieva dStream, Philips Healthcare, Best, Netherlands). Segmentation of adipose tissue was performed with a custom-made Matlab software tool. Statistical measures of agreement were the coefficient of determination R2 of a linear fit. RESULTS: Mean ASATREF was 12,976 (7812-24,161) cm3 and mean VATREF was 4068 (1137-7518) cm3. Mean half-body volumes relative to the whole-body values were 50.8% (48.2-53.7%) for ASATL and 49.2% (46.3-51.8%) for ASATR. Corresponding volume fractions were 56.4% (51.4-65.9%) for VATL and 43.6% (34.1-48.6%) for VATR. Correlations of ASATREF with ASATL as well as with ASATR were both excellent (R2 > 0.99, p < 0.01). Corresponding correlations of VATREF were marginally lower (R2 = 0.98 for VATL, p < 0.01, and R2 = 0.97 for VATR, p < 0.01). CONCLUSIONS: In conclusion, abdominal fat volumes can be reliably assessed by half-body MRI data, in particular the subcutaneous fat compartment.


Assuntos
Gordura Abdominal/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Obesidade Abdominal/diagnóstico por imagem , Adulto , Idoso , Algoritmos , Antropometria , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade
7.
BMC Med Imaging ; 19(1): 32, 2019 04 27.
Artigo em Inglês | MEDLINE | ID: mdl-31029093

RESUMO

BACKGROUND: The goal of our study was to evaluate the current approach in prediction of postoperative major complications after pancreaticoduodenectomy (PD), especially symptomatic pancreatic fistula (POPF), using parameters derived from computed tomography (CT). METHODS: Patients after PD were prospectively collected in a database of the local department of surgery and all patients with CT scans available were assessed in this study. CT parameters were measured at the level of the intervertebral disc L3/L4 and consisted of the areas of the visceral adipose tissue (AVAT), the diameters of the pancreatic parenchyma (DPP) and the pancreatic duct (DPD), the areas of ventral abdominal wall muscle (AMVEN), psoas muscle (AMPSO), paraspinal muscle (AMSPI), total muscle (AMTOT), as well as the mean muscle attenuation (MA) and skeletal muscle index (SMI). Mann-Whitney-U Test for two independent samples and binary logistic regression were used for statistical analysis. RESULTS: One hundred thirty-nine patients (55 females, 84 males) were included. DPD was 2.9 mm (Range 0.7-10.7) on median and more narrow in patients with complications equal to or greater stadium IIIb (p < 0.04) and severe POPF (p < 0.01). DPP median value was 17 (6.9-37.9) mm and there was no significant difference regarding major complications or POPF. AVAT showed a median value of 127.5 (14.5-473.0) cm2 and was significantly larger in patients with POPF (p < 0.01), but not in cases of major complications (p < 0.06). AMPSO, AMSPI, AMVEN and AMTOT showed no significant differences between major complications and POPF. MA was both lower in groups with major complications (p < 0.01) and POPF (p < 0.01). SMI failed to differentiate between patients with or without major complications or POPF. CONCLUSION: Besides the known factors visceral obesity and narrowness of the pancreatic duct, the mean muscle attenuation can easily be examined on routine preoperative CT scans and seems to be promising parameter to predict postoperative complications and POPF.


Assuntos
Fístula Pancreática/diagnóstico por imagem , Pancreaticoduodenectomia/efeitos adversos , Complicações Pós-Operatórias/diagnóstico por imagem , Sarcopenia/diagnóstico por imagem , Idoso , Feminino , Humanos , Disco Intervertebral/diagnóstico por imagem , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Fístula Pancreática/mortalidade , Complicações Pós-Operatórias/mortalidade , Estudos Prospectivos , Sarcopenia/etiologia , Sarcopenia/mortalidade , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
8.
J Transl Med ; 15(1): 106, 2017 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-28521774

RESUMO

BACKGROUND: The assessment of fibrosis and inflammatory activity is essential to identify patients with non-alcoholic fatty liver disease (NAFLD) at risk for progressive disease. Serum markers and ultrasound-based methods can replace liver biopsy for fibrosis staging, whereas non-invasive characterization of inflammatory activity remains a clinical challenge. Cell-free DNA (cfDNA) is a novel non-invasive biomarker for assessing cellular inflammation and cell death, which has not been evaluated in NAFLD. METHODS: Patients and healthy controls from two previous studies were included. NAFLD disease activity and severity were non-invasively characterized by liver stiffness measurement (transient elastography, TE) including steatosis assessment with controlled attenuation parameter (CAP), single-proton magnetic resonance spectroscopy (1H-MRS) for determination of hepatic fat fraction, aminotransferases and serum ferritin. cfDNA levels (90 and 222 bp fragments) were analyzed using quantitative real-time PCR. RESULTS: Fifty-eight NAFLD patients (age 62 ± 11 years, BMI 28.2 ± 3.5 kg/m2) and 13 healthy controls (age 38 ± 12 years, BMI 22.4 ± 2.1 kg/m2) were included. 90 bp cfDNA levels were significantly higher in NAFLD patients compared to healthy controls: 3.7 (1.3-23.1) vs. 2.9 (1.4-4.1) ng/mL (p = 0.014). In the NAFLD cohort, circulating cfDNA correlated significantly with disease activity and severity, especially in patients with elevated liver stiffness (n = 13, 22%) compared to cases with TE values ≤7 kPa: cf90 bp 6.05 (2.41-23.13) vs. 3.16 (1.29-7.31) ng/mL (p < 0.001), and cf222 bp 14.41 (9.27-22.90) vs. 11.32 (6.05-18.28) ng/mL (p = 0.0041). CONCLUSIONS: Cell-free DNA plasma concentration correlates with established non-invasive markers of NAFLD activity and severity. Therefore, cfDNA should be further evaluated as biomarker for identifying patients at risk for progressive NAFLD.


Assuntos
Ácidos Nucleicos Livres/sangue , Hepatopatia Gordurosa não Alcoólica/sangue , Hepatopatia Gordurosa não Alcoólica/patologia , Índice de Gravidade de Doença , Adulto , Antropometria , Fenômenos Biomecânicos , Estudos de Coortes , Feminino , Humanos , Fígado/patologia , Fígado/fisiopatologia , Masculino , Síndrome Metabólica/sangue , Síndrome Metabólica/complicações , Síndrome Metabólica/fisiopatologia , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica/complicações
9.
Eur Radiol ; 26(8): 2462-70, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26563349

RESUMO

OBJECTIVES: To evaluate clinical effectiveness and diagnostic efficiency of a navigation device for MR-guided biopsies of focal liver lesions in a closed-bore scanner. METHODS: In 52 patients, 55 biopsies were performed. An add-on MR navigation system with optical instrument tracking was used for image guidance and biopsy device insertion outside the bore. Fast control imaging allowed visualization of the true needle position at any time. The biopsy workflow and procedure duration were recorded. Histological analysis and clinical course/outcome were used to calculate sensitivity, specificity and diagnostic accuracy. RESULTS: Fifty-four of 55 liver biopsies were performed successfully with the system. No major and four minor complications occurred. Mean tumour size was 23 ± 14 mm and the skin-to-target length ranged from 22 to 177 mm. In 39 cases, access path was double oblique. Sensitivity, specificity and diagnostic accuracy were 88 %, 100 % and 92 %, respectively. The mean procedure time was 51 ± 12 min, whereas the puncture itself lasted 16 ± 6 min. On average, four control scans were taken. CONCLUSIONS: Using this navigation device, biopsies of poorly visible and difficult accessible liver lesions could be performed safely and reliably in a closed-bore MRI scanner. The system can be easily implemented in clinical routine workflow. KEY POINTS: • Targeted liver biopsies could be reliably performed in a closed-bore MRI. • The navigation system allows for image guidance outside of the scanner bore. • Assisted MRI-guided biopsies are helpful for focal lesions with a difficult access. • Successful integration of the method in clinical workflow was shown. • Subsequent system installation in an existing MRI environment is feasible.


Assuntos
Biópsia por Agulha/métodos , Biópsia Guiada por Imagem/métodos , Neoplasias Hepáticas/diagnóstico , Fígado/patologia , Imagem por Ressonância Magnética Intervencionista/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
10.
NMR Biomed ; 28(5): 583-90, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25808071

RESUMO

The quantification of visceral adipose tissue (VAT) is increasingly being considered for risk assessment and treatment monitoring in obese patients, but is generally time-consuming. The goals of this work were to semi-automatically segment and quantify VAT areas of MRI slices at previously proposed anatomical landmarks and to evaluate their predictive power for whole-abdominal VAT volumes on a relatively large number of patients. One-hundred and ninety-seven overweight to severely obese patients (65 males; body mass index, 33.3 ± 3.5 kg/m(2); 132 females; body mass index, 34.3 ± 3.2 kg/m(2)) underwent MRI examination. Total VAT volumes (VVAT-T ) of the abdominopelvic cavity were quantified by retrospective analysis of two-point Dixon MRI data (active-contour segmentation, visual correction and histogram analysis). VVAT-T was then compared with VAT areas determined on one or five slices defined at seven anatomical landmarks (lumbar intervertebral spaces, umbilicus and femoral heads) and corresponding conversion factors were determined. Statistical measures were the coefficients of variation and standard deviations σ1 and σ5 of the difference between predicted and measured VAT volumes (Bland-Altman analysis). VVAT-T was 6.0 ± 2.0 L (2.5-11.2 L) for males and 3.2 ± 1.4 L (0.9-7.7 L) for females. The analysis of five slices yielded a better agreement than the analysis of single slices, required only a little extra time (4 min versus 2 min) and was substantially faster than whole-abdominal assessment (24 min). Best agreements were found at intervertebral spaces L3-L4 for females (σ5/1 = 523/608 mL) and L2-L3 for males (σ5/1 = 613/706 mL). Five-slice VAT volume estimates at the level of lumbar disc L3-L4 for females and L2-L3 for males can be obtained within 4 min and were a reliable predictor for abdominopelvic VAT volume in overweight to severely adipose patients. One-slice estimates took only 2 min and were slightly less accurate. These findings may contribute to the implementation of analytical methods for fast and reliable (routine) estimation of VAT volumes in obese patients.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Gordura Intra-Abdominal/patologia , Obesidade Mórbida/patologia , Sobrepeso/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Pontos de Referência Anatômicos/patologia , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
Acta Radiol ; 56(1): 121-8, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24504488

RESUMO

BACKGROUND: Clinical management of prostate cancer increasingly aims to distinguish aggressive types that require immediate and radical treatment from indolent tumors that are candidates for watchful waiting. This requires reliable and reproducible parameters to effectively control potential cancer progression. Magnetic resonance imaging (MRI) may provide a non-invasive means for this purpose. PURPOSE: To assess the value of diffusion-weighted imaging and proton MR spectroscopy for the prediction of prostate cancer (PCa) aggressiveness. MATERIAL AND METHODS: In 39 of 64 consecutive patients who underwent endorectal 3-T MRI prior to radical prostatectomy, prostate specimens were analyzed as whole-mount step sections. Apparent diffusion coefficient (ADC), normalized ADC (nADC: tumor/healthy tissue), choline/citrate (CC), and (choline + creatine)/citrate (CCC) ratios were correlated with Gleason scores (GS) from histopathological results. The power to discriminate low (GS ≤ 6) from higher-risk (GS ≥ 7) tumors was assessed with receiver operating characteristics (area under the curve [AUC]). Resulting threshold values were used by a blinded reader to distinguish between aggressive and indolent tumors. RESULTS: Ninety lesions (1 × GS = 5, 41 × GS = 6, 36 × GS = 7, 12 × GS = 8) were considered. nADC (AUC = 0.90) showed a higher discriminatory power than ADC (AUC = 0.79). AUC for CC and CCC were 0.73 and 0.82, respectively. Using either nADC < 0.46 or CCC > 1.3, as well as both criteria for aggressive PCa, the reader correctly identified aggressive and indolent tumors in 31 (79%), 28 (72%), and 33 of 39 patients (85%), respectively. Predictions of tumor aggressiveness from TRUS-guided biopsies were correct in 27 of 36 patients (75%). CONCLUSION: The combination of a highly sensitive normalized ADC with a highly specific CCC was found to be well suited to prospectively estimate PCa aggressiveness with a similar diagnostic accuracy as biopsy results.


Assuntos
Biomarcadores Tumorais/análise , Colina/análise , Imagem de Difusão por Ressonância Magnética/métodos , Imageamento Tridimensional/métodos , Neoplasias da Próstata/química , Neoplasias da Próstata/diagnóstico , Espectroscopia de Prótons por Ressonância Magnética/métodos , Idoso , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Imagem Molecular/métodos , Invasividade Neoplásica , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
NMR Biomed ; 27(9): 1123-8, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25066754

RESUMO

Subcutaneous (SAT) and visceral adipose tissue (VAT) differ in composition, endocrine function and localization in the body. VAT is considered to play a role in the pathogenesis of insulin resistance, type 2 diabetes, fatty liver disease, and other obesity-related disorders. It has been shown that the amount, distribution, and (cellular) composition of adipose tissue (AT) correlate well with metabolic conditions. In this study, T1 relaxation times of AT were measured in severely obese subjects and compared with those of healthy lean controls. Here, we tested the hypothesis that T1 relaxation times of AT differ between lean and obese individuals, but also between VAT and SAT as well as superficial (sSAT) and deep SAT (dSAT) in the same individual. Twenty severely obese subjects (BMI 41.4 ± 4.8 kg/m(2) ) and ten healthy lean controls matched for age (BMI 21.5 ± 1.9 kg/m(2) ) underwent MRI at 1.5 T using a single-shot fast spin-echo sequence (short-tau inversion recovery) at six different inversion times (TI range 100-1000 ms). T1 relaxation times were computed for all subjects by fitting the TI -dependent MR signal intensities of user-defined regions of interest in both SAT and VAT to a model function. T1 times in sSAT and dSAT were only measured in obese patients. For both obese patients and controls, the T1 times of SAT (275 ± 14 and 301 ± 12 ms) were significantly (p < 0.01) shorter than the respective values in VAT (294 ± 20 and 360 ± 35 ms). Obese subjects also showed significant (p < 0.01) T1 differences between sSAT (268 ± 11 ms) and dSAT (281 ± 19 ms). More important, T1 differences in both SAT and VAT were highly significant (p < 0.001) between obese patients and healthy subjects. The results of our pilot study suggest that T1 relaxation times differ between severely obese patients and lean controls, and may potentially provide an additional means for the non-invasive assessment of AT conditions and dysfunction.


Assuntos
Tecido Adiposo/patologia , Adiposidade , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Obesidade Mórbida/patologia , Adulto , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
Rofo ; 2024 Apr 03.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-38569516

RESUMO

BACKGROUND: This review discusses the quantitative assessment of tissue composition in the human body (body composition, BC) using radiological methods. Such analyses are gaining importance, in particular, for oncological and metabolic problems. The aim is to present the different methods and definitions in this field to a radiological readership in order to facilitate application and dissemination of BC methods. The main focus is on radiological cross-sectional imaging. METHODS: The review is based on a recent literature search in the US National Library of Medicine catalog (pubmed.gov) using appropriate search terms (body composition, obesity, sarcopenia, osteopenia in conjunction with imaging and radiology, respectively), as well as our own work and experience, particularly with MRI- and CT-based analyses of abdominal fat compartments and muscle groups. RESULTS AND CONCLUSION: Key post-processing methods such as segmentation of tomographic datasets are now well established and used in numerous clinical disciplines, including bariatric surgery. Validated reference values are required for a reliable assessment of radiological measures, such as fatty liver or muscle. Artificial intelligence approaches (deep learning) already enable the automated segmentation of different tissues and compartments so that the extensive datasets can be processed in a time-efficient manner - in the case of so-called opportunistic screening, even retrospectively from diagnostic examinations. The availability of analysis tools and suitable datasets for AI training is considered a limitation. KEY POINTS: · Radiological imaging methods are increasingly used to determine body composition (BC).. · BC parameters are usually quantitative and well reproducible.. · CT image data from routine clinical examinations can be used retrospectively for BC analysis.. · Prospectively, MRI examinations can be used to determine organ-specific BC parameters.. · Automated and in-depth analysis methods (deep learning or radiomics) appear to become important in the future.. CITATION FORMAT: · Linder N, Denecke T, Busse H. Body composition analysis by radiological imaging - methods, applications, and prospects. Fortschr Röntgenstr 2024; DOI: 10.1055/a-2263-1501.

14.
Magn Reson Med ; 70(1): 225-31, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23716388

RESUMO

PURPOSE: To demonstrate the feasibility of a novel experimental method to quantitatively analyze fiber-network deformation in compressed cartilage by angle-sensitive magnetic resonance imaging (MRI) of cartilage. METHODS: Three knee cartilage samples of an adult sheep were imaged in a high-resolution MRI scanner at 7 T. Main fiber orientation and its "offset" from the direction perpendicular to the bone-cartilage boundary were derived from MR images taken at different orientations with respect to B0. Bending of the collagen fibers was determined from weight-bearing MRI with the load (up to 1.0 MPa) applied over the whole sample surface. A "fascicle" model of the cartilage ultrastructure was assumed to analyze characteristic intensity variations in T2-weighted images under load. RESULTS: T2-weighted MR images showed a strong variation of the signal intensities with sample orientation. In the T2-weighted weight-bearing series, regions of high signal intensity underwent shifts from the lateral to the central parts in all three cartilage samples. The bending of the collagen fibers was determined to be 27.2°, 35.4°, and 40.0° per MPa, respectively. CONCLUSION: Assuming a "fascicle" model, the presented MRI method provides quantitative measures of structural adjustments in compressed cartilage. Our preliminary analysis suggests that cartilage fiber deformation includes both bending and crimping.


Assuntos
Cartilagem Articular/citologia , Cartilagem Articular/fisiologia , Colágenos Fibrilares/fisiologia , Colágenos Fibrilares/ultraestrutura , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Animais , Força Compressiva/fisiologia , Técnicas In Vitro , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Ovinos , Estresse Mecânico
16.
NMR Biomed ; 26(11): 1412-9, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23801556

RESUMO

Signal intensities of T2-weighted magnetic resonance images depend on the local fiber arrangement in hyaline cartilage. The aims of this study were to determine whether angle-sensitive MRI at 7 T can be used to quantify the cartilage ultrastructure of the knee in vivo and to assess potential differences with age. Ten younger (21-30) and ten older (55-76 years old) healthy volunteers were imaged with a T2-weighted spin-echo sequence in a 7 T whole-body MRI. A "fascicle" model was assumed to describe the depth-dependent fiber arrangement of cartilage. The R/T boundary positions between radial and transitional zones were assessed from intensity profiles in small regions of interest in the femur and tibia, and normalized to cartilage thickness using logistic curve fits. The quality of our highly resolved (0.3 × 0.3 × 1.0 mm(3)) MR cartilage images were high enough for quantitative analysis (goodness of fit R(2) = 0.91 ± 0.09). Between younger and older subjects, normalized positions of the R/T boundary, with value 0 at the bone-cartilage interface and 1 at the cartilage surface, were significantly (p < 0.05) different in femoral (0.51 ± 0.12 versus 0.41 ± 0.10), but not in tibial cartilage (0.65 ± 0.11 versus 0.57 ± 0.09, p = 0.119). Within both age groups, differences between femoral and tibial R/T boundaries were significant. Using a fascicle model and angle-sensitive MRI, the depth-dependent anisotropic fiber arrangement of knee cartilage could be assessed in vivo from a single 7 T MR image. The derived quantitative parameter, thickness of the radial zone, may serve as an indicator of the structural integrity of cartilage. This method may potentially be suitable to detect and monitor early osteoarthritis because the progressive disintegration of the anisotropic network is also indicative of arthritic changes in cartilage.


Assuntos
Cartilagem Articular/ultraestrutura , Joelho/anatomia & histologia , Imageamento por Ressonância Magnética , Adulto , Idoso , Feminino , Fêmur/anatomia & histologia , Humanos , Masculino , Pessoa de Meia-Idade , Tíbia/anatomia & histologia , Adulto Jovem
17.
J Magn Reson Imaging ; 37(6): 1480-5, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23055397

RESUMO

PURPOSE: To present a novel method for MR elastography (MRE) of the prostate at 3 Tesla using a modified endorectal imaging coil. MATERIALS AND METHODS: A commercial endorectal coil was modified to dynamically generate mechanical stress (contraction and dilation) in a prostate phantom with embedded phantom "lesions" (6 mm diameter) and in a porcine model. Resulting tissue displacements were measured with a motion-sensitive EPI sequence at actuation frequencies of 50-200 Hz. Maps of shear modulus G were calculated from the measured phase-difference shear-wave patterns. RESULTS: In the G maps of the phantom, "lesions" were easily discernible against the background. The average G values of regions of interest placed in the "lesion" (8.2 ± 1.9 kPa) were much higher than those in the background (3.6 ± 1.4 kPa) but systematically lower than values reported by the vendor (13.0 ± 1.0 and 6.7 ± 0.7 kPa, respectively). In the porcine model, shear waves could be generated and measured shear moduli were substantially different for muscle (7.1 ± 2.0 kPa), prostate (3.0 ± 1.4 kPa), and bulbourethral gland (5.6 ± 1.9 kPa). CONCLUSION: An endorectal MRE concept is technically feasible. The presented technique will allow for simultaneous MRE and MRI acquisitions using a commercial base device with minor, MR-conditional modifications. The diagnostic value needs to be determined in further trials.


Assuntos
Técnicas de Imagem por Elasticidade/instrumentação , Aumento da Imagem/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Magnetismo/instrumentação , Próstata/patologia , Próstata/fisiologia , Transdutores , Módulo de Elasticidade/fisiologia , Humanos , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Masculino , Imagens de Fantasmas , Reto/patologia , Reto/fisiologia , Estresse Mecânico
18.
J Magn Reson Imaging ; 37(5): 1144-50, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23124651

RESUMO

PURPOSE: To present software for supervised automatic quantification of visceral and subcutaneous adipose tissue (VAT, SAT) and evaluates its performance in terms of reliability, interobserver variation, and processing time, since fully automatic segmentation of fat-fraction magnetic resonance imaging (MRI) is fast but susceptible to anatomical variations and artifacts, particularly for advanced stages of obesity. MATERIALS AND METHODS: Twenty morbidly obese patients (average BMI 44 kg/m(2) ) underwent 1.5-T MRI using a double-echo gradient-echo sequence. Fully automatic analysis (FAA) required no user interaction, while supervised automatic analysis (SAA) involved review and manual correction of the FAA results by two observers. Standard of reference was provided by manual segmentation analysis (MSA). RESULTS: Average processing times per patient were 6, 6+4, and 21 minutes for FAA, SAA, and MSA (P < 0.001), respectively. For VAT/SAT assessment, Pearson correlation coefficients, mean (bias), and standard deviations of the differences were R = 0.950, +0.003, and 0.043 between FAA and MSA and R = 0.981, +0.009, and 0.027 between SAA and MSA. Interobserver variation and intraclass correlation were 3.1% and 0.996 for SAA, and 6.6% and 0.986 for MSA, respectively. CONCLUSION: The presented supervised automatic approach provides a reliable option for MRI-based fat quantification in morbidly obese patients and was much faster than manual analysis.


Assuntos
Gordura Abdominal/patologia , Adiposidade , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Obesidade Mórbida/patologia , Reconhecimento Automatizado de Padrão/métodos , Software , Adolescente , Adulto , Algoritmos , Feminino , Humanos , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
19.
Insights Imaging ; 14(1): 9, 2023 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-36645551

RESUMO

OBJECTIVES: The aim was to assess the type, frequency and impact of MRI-related complications in patients with cochlear implants (CI) and MRI indications in different body regions. METHODS: For that purpose, the institutional radiology database of a single tertiary hospital was searched for patients with a CI who underwent MRI between 2001 and 2018. The number of MRI examinations and complications were retrieved from the patient record. Examinations were categorized into five distinct body regions or combinations thereof. Records of CI artifacts in the head also included basic information on diagnostic image quality. RESULTS: Out of 1017 MRI database entries (examinations) of patients with a CI, 91 records were after implantation (71 patients) and 66 were attempted (no contraindications, 49 patients). In four cases (4/66, 6.1%), the magnet was dislocated and had to be replaced surgically. Three out of four severe complications occurred for examination regions outside the head. Thirteen MRI examinations were aborted due to pain (19.7%) and one because of artifacts-resulting in 48 scans (72.7%) completed successfully (36 patients). All cranial scans featured device artifacts in all sequences, but the majority of them did not affect proper imaging diagnostics in the respective region. CONCLUSION: This retrospective, single-center analysis of patients with MRI-conditional cochlear implants shows that MRI-related complications were common, at least in models with a fixed magnet, despite appropriate precautions and compliance with the manufacturers' guidelines. MRI examinations of CI patients should therefore be indicated strictly until the exact causes have been clarified.

20.
Eur Radiol ; 22(8): 1820-8, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22527373

RESUMO

OBJECTIVES: To evaluate the influence of the choice of b values on the diagnostic value of the apparent diffusion coefficient (ADC) for detection and grading of prostate cancer (PCa). METHODS: Forty-one patients with biopsy-proven PCa underwent endorectal 3-T MRI before prostatectomy. Different combinations of b values (0-800 s/mm(2)) were used to calculate four representative ADC maps. Mean ADCs of tumours and non-malignant tissue were determined. Tumour appearance on different ADC maps was rated by three radiologists as good, fair or poor by assigning a visual score (VS) of 2, 1 or 0, respectively. Differences in the ADC values with the choice of b values were analysed using one-way ANOVA. RESULTS: Choice of b values had a highly (P < 0.001) significant influence on the absolute ADC in each tissue. Maps using b = [50, 800] and [0, 800] were rated best (VS= 1.6 ± 0.3) and second best (1.1 ± 0.3, P < 0.001), respectively. For low-grade carcinomas (Gleason score ≤ 6, 13/41 patients), only the former choice received scores better than fair (VS = 1.4 ± 0.3). Mean tumour ADCs showed significant negative correlation (Spearman's ρ -0.38 to -0.46, P < 0.05) with Gleason score. CONCLUSIONS: Absolute ADC values strongly depend on the choice of b values and therefore should be used with caution for diagnostic purposes. A minimum b value greater than zero is recommended for ADC calculation to improve the visual assessment of PCa in ADC maps. KEY POINTS: • Absolute ADC values are highly dependent on the choice of b values. • Absolute ADC thresholds should be used carefully to predict tumour aggressiveness. • Subjective ratings of ADC maps involving b = 0 s/mm ( 2 ) are poor to fair. • Minimum b value greater than 0 s/mm ( 2 ) is recommended for ADC calculation.


Assuntos
Imageamento por Ressonância Magnética/métodos , Oncologia/métodos , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/patologia , Idoso , Diagnóstico por Imagem/métodos , Diagnóstico por Imagem/normas , Difusão , Imagem Ecoplanar/métodos , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/normas , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Variações Dependentes do Observador , Antígeno Prostático Específico/biossíntese , Prostatectomia/métodos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA