Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
Gastroenterol Hepatol ; : 502214, 2024 Jun 04.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38844201

RESUMO

Helicobacter pylori (Hp) is the main trigger of chronic gastric atrophy and the main leading cause of gastric cancer. Hp infects the normal gastric mucosa and can lead to chronic inflammation, glandular atrophy, intestinal metaplasia, dysplasia and finally adenocarcinoma. Chronic inflammation and gastric atrophy associated with Hp infection appear initially in the distal part of the stomach (the antrum) before progressing to the proximal part (the corpus-fundus). In recent years, endoscopic developments have allowed for the characterization of various gastric conditions including the normal mucosa (pyloric/fundic gland pattern and regular arrangement of collecting venules), Hp-related gastritis (Kyoto classification), glandular atrophy (Kimura-Takemoto classification), intestinal metaplasia (Endoscopic Grading of Gastric Intestinal Metaplasia), and dysplasia/adenocarcinoma (Vessel plus Surface classification). Despite being independent classifications, all these scales can be integrated into a single model: the endoscopic model for gastric carcinogenesis. This model would assist endoscopists in comprehending the process of gastric carcinogenesis and conducting a systematic examination during gastroscopy. Having this model in mind would enable endoscopists to promptly recognize the implications of Hp infection and the potential patient's risk of developing gastric cancer.

2.
Gastroenterol Hepatol ; 47(3): 246-252, 2024 Mar.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-37236304

RESUMO

BACKGROUND AND OBJECTIVES: There are few scales with prospective validation for the assessment of the upper gastrointestinal mucosal cleanliness during an esophagogastroduodenoscopy (EGD). The aim of this study was to develop a valid and reproducible cleanliness scale for use during an EGD. METHODS: We developed a cleanliness scale (Barcelona scale) with a score (0-2 points) of five segments of the upper gastrointestinal tract with thorough cleaning techniques (esophagus, fundus, body, antrum, and duodenum). First, 125 photos (25 of each area) were assessed, and a score was assigned to each image by consensus among 7 experts endoscopists. Subsequently, 100 of the 125 images were selected and the inter- and intra-observer variability of 15 previously trained endoscopists was evaluated using the same images at two different times. RESULTS: In total, 1500 assessments were performed. In 1336/1500 observations (89%) there was agreement with the consensus score, with a mean kappa value of 0.83 (0.45-0.96). In the second evaluation, in 1330/1500 observations (89%) there was agreement with the consensus score, with a mean kappa value of 0.82 (0.45-0.93). The intra-observer variability was 0.89 (0.76-0.99). CONCLUSIONS: The Barcelona cleanliness scale is a valid measure and reproducible with minimal training. Its application in clinical practice is a significant step to standardize the quality of the EGD.


Assuntos
Duodeno , Mucosa , Humanos , Consenso , Endoscopia do Sistema Digestório
3.
Dig Dis Sci ; 68(4): 1447-1454, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36104534

RESUMO

BACKGROUND: Motorized Spiral Enteroscopy (MSE) reduces procedure time and increases insertion depth into the small bowel; however, there is scarce evidence on factors affecting MSE efficacy. AIMS: To evaluate diagnostic yield and adverse events of MSE including patients with prior major abdominal surgery. METHODS: A prospective observational study was conducted on patients undergoing MSE from June 2019 to December 2021. Demographic characteristics, procedure time, depth of maximum insertion (DMI), technical success, diagnostic yield, and adverse events were collected. RESULTS: Seventy-four anterograde (54.4%) and 62 retrograde (45.6%) enteroscopies were performed in 117 patients (64 males, median age 67 years). Fifty patients (42.7%) had prior major abdominal surgery. Technical success was 91.9% for anterograde and 90.3% for retrograde route. Diagnostic yield was 71.6% and 61.3%, respectively. The median DMI was 415 cm (264-585) for anterograde and 120 cm (37-225) for retrograde enteroscopy. In patients with prior major abdominal surgery, MSE showed significantly longer small bowel insertion time (38 vs 29 min, p = 0.004), with similar diagnostic yield (61 vs 71.4%, p = 0.201) and DMI (315 vs 204 cm, p = 0.226). The overall adverse event rate was 10.3% (SAE 1.5%), with no differences related to prior abdominal surgery (p = 0.598). Patients with prior surgeries directly involving the gastrointestinal tract showed lower DMI (189 vs 374 cm, p = 0.019) with equal exploration time (37.5 vs 38 min, p = 0.642) compared to those with other abdominal surgeries. CONCLUSIONS: MSE is effective and safe in patients with major abdominal surgery, although longer procedure times were observed. A lower depth of insertion was detected in patients with gastrointestinal surgery.


Assuntos
Enteropatias , Laparoscopia , Masculino , Humanos , Idoso , Enteropatias/diagnóstico , Endoscopia Gastrointestinal/efeitos adversos , Endoscopia Gastrointestinal/métodos , Estudos Prospectivos , Intestino Delgado/cirurgia , Enteroscopia de Duplo Balão/métodos
4.
Gastroenterol Hepatol ; 46(6): 483-488, 2023.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-36195279

RESUMO

Helicobacter pylori (H. pylori) infection is highly prevalent in our environment and is associated with highly relevant gastric disease, both benign and malignant. The gold standard for diagnosis is histological confirmation by biopsy. However, there is increasing evidence that optical endoscopic diagnosis could have a fundamental role in avoiding unnecessary biopsies in certain cases. Specifically, the regular distribution of the collecting venules (RAC pattern) seems to have a high negative predictive value (NPV) to rule out infection. This review describes the most outstanding endoscopic findings with the best diagnostic potential for H. pylori infection after an exhaustive search comparing the most relevant studies that have been carried out in Europe and the East.


Assuntos
Gastrite , Infecções por Helicobacter , Helicobacter pylori , Humanos , Gastroscopia , Mucosa Gástrica , Gastrite/diagnóstico , Infecções por Helicobacter/diagnóstico , Biópsia
5.
Gastroenterol Hepatol ; 46(5): 360-368, 2023 May.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-36179948

RESUMO

BACKGROUND: Barrett's esophagus (BE) is an entity with a known histological progression to malignancy. The insulin-like growth factor (IGF) system is involved in the carcinogenesis through obesity-related mechanisms that include IGF and it has been associated with several types of cancer. OBJECTIVES: To evaluate the serological levels of IGF-1 and IGFBP-3 in patients with BE and esophageal adenocarcinoma. PATIENTS AND METHODS: Prospective study of patients with BE and esophageal adenocarcinoma who underwent upper endoscopy between September 2012 and December 2015. A baseline determination of IGF-1 and IGFBP-3 was performed. We included a control group of patients without BE. RESULTS: One hundred sixteen patients were included: 36 controls, 62 with BE (42 without dysplasia and 20 with dysplasia) and 18 with adenocarcinoma. IGF-1 and IGF-1/IGFBP-3 molar ratio showed a progression to high levels in BE and adenocarcinoma than in controls (IGF-1: 135.55±66.07ng/ml, 148.33±81.5ng/ml, 108.19±46.69ng/ml, respectively; P=.049) (molar ratio: 0.23±0.91, 0.29±0.11, 0.19±0.06, respectively; P=.001), without differences between the histological types of BE. Fifty-four out of the 65 patients with BE were followed up (median of 58.50 months, range 12-113) and 11 of them (20.4%) presented progression to low-grade dysplasia (n=8) or high-grade dysplasia/adenocarcinoma (n=3), without differences in the IGF system compared with patients without progression. CONCLUSIONS: Patients with BE and esophageal adenocarcinoma have changes in the IGF system although the serological levels of IGF-1 and IGFBP-3 do not correlate with histological progression of BE.


Assuntos
Adenocarcinoma , Esôfago de Barrett , Neoplasias Esofágicas , Humanos , Esôfago de Barrett/metabolismo , Esôfago de Barrett/patologia , Estudos Longitudinais , Proteína 3 de Ligação a Fator de Crescimento Semelhante à Insulina , Fator de Crescimento Insulin-Like I/metabolismo , Estudos Prospectivos , Progressão da Doença , Neoplasias Esofágicas/patologia , Adenocarcinoma/patologia
6.
Dig Dis ; 40(3): 376-384, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34348294

RESUMO

BACKGROUND: Regular arrangement of collecting venules (RAC) in gastric mucosa accurately identifies patients without Helicobacter pylori (H pylori) infection. The aim of our study was to evaluate the reproducibility of RAC using white light endoscopy without magnification, in a European country, and to assess the impact of proton pump inhibitors (PPIs). METHODS: A multicenter prospective study with image capture of the distal lesser gastric curvature and gastric biopsies was performed. The presence of starfish-like minute points regularly distributed throughout lesser curvature was considered as RAC positive (RAC+). A set of 20 images was used for the training phase and inter and intra-observer agreements were calculated. RESULTS: 174 patients were included and 85 (48.9%) were taking PPIs. Kappa values for interobserver and intra-observer agreements were substantial (0.786) and excellent (0.906), respectively. H. pylori infection was diagnosed in 29 patients (16.7%): 10/85 with PPIs and 19/89 without PPIs (11.8% vs. 21.3%; p = 0.09). All RAC + patients were free of H. pylori infection, with a sensitivity and negative predictive value of 100%, regardless of PPI intake. CONCLUSION: The endoscopic diagnosis of H. pylori by RAC is an easy-to-learn and highly reproducible technique, even with PPI intake. Our results warrant RAC as a real-time diagnostic method for H. pylori-negative infection in Western practice.


Assuntos
Infecções por Helicobacter , Helicobacter pylori , Mucosa Gástrica/patologia , Gastroscopia/métodos , Infecções por Helicobacter/diagnóstico , Humanos , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes , Vênulas/patologia
7.
Dig Dis ; 39(3): 179-189, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33002891

RESUMO

BACKGROUND: Guidelines give robust recommendations on which biopsies should be taken when there is endoscopic suggestion of gastric inflammation. Adherence to these guidelines often seems arbitrary. This study aimed to give an overview on current practice in tertiary referral centres across Europe. METHODS: Data were collected at 10 tertiary referral centres. Demographic data, the indication for each procedure, endoscopic findings, and the number and sampling site of biopsies were recorded. Findings were compared between centres, and factors influencing the decision to take biopsies were explored. RESULTS: Biopsies were taken in 56.6% of 9,425 procedures, with significant variation between centres (p < 0.001). Gastric biopsies were taken in 43.8% of all procedures. Sampling location varied with the procedure indication (p < 0.001) without consistent pattern across the centres. Fewer biopsies were taken in centres which routinely applied the updated Sydney classification for gastritis assessment (46.0%), compared to centres where this was done only upon request (75.3%, p < 0.001). This was the same for centres stratifying patients according to the OLGA system (51.8 vs. 73.0%, p < 0.001). More biopsies were taken in centres following the MAPS guidelines on stomach surveillance (68.1 vs. 37.1%, p < 0.001). Biopsy sampling was more likely in younger patients in 8 centres (p < 0.05), but this was not true for the whole cohort (p = 0.537). The percentage of procedures with biopsies correlated directly with additional costs charged in case of biopsies (r = 0.709, p = 0.022). CONCLUSION: Adherence to guideline recommendations for biopsy sampling at gastroscopy was inconsistent across the participating centres. Our data suggest that centre-specific policies are applied instead.


Assuntos
Endoscopia Gastrointestinal , Encaminhamento e Consulta , Centros de Atenção Terciária , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
8.
BMC Med ; 18(1): 255, 2020 09 18.
Artigo em Inglês | MEDLINE | ID: mdl-32943059

RESUMO

BACKGROUND: Colon capsule endoscopy (CCE) and CT colonography (CTC) are minimally invasive techniques for colorectal cancer (CRC) screening. Our objective is to compare CCE and CTC for the identification of patients with colorectal neoplasia among participants in a CRC screening programme with positive faecal immunochemical test (FIT). Primary outcome was to compare the performance of CCE and CTC in detecting patients with neoplastic lesions. METHODS: The VICOCA study is a prospective, single-centre, randomised trial conducted from March 2014 to May 2016; 662 individuals were invited and 349 were randomised to CCE or CTC before colonoscopy. Endoscopists were blinded to the results of CCE and CTC. RESULTS: Three hundred forty-nine individuals were included: 173 in the CCE group and 176 in the CTC group. Two hundred ninety individuals agreed to participate: 147 in the CCE group and 143 in the CTC group. In the intention-to-screen analysis, sensitivity, specificity and positive and negative predictive values for the identification of individuals with colorectal neoplasia were 98.1%, 76.6%, 93.7% and 92.0% in the CCE group and 64.9%, 95.7%, 96.8% and 57.7% in the CTC group. In terms of detecting significant neoplastic lesions, the sensitivity of CCE and CTC was 96.1% and 79.3%, respectively. Detection rate for advanced colorectal neoplasm was higher in the CCE group than in the CTC group (100% and 93.1%, respectively; RR = 1.07; p = 0.08). Both CCE and CTC identified all patients with cancer. CCE detected more patients with any lesion than CTC (98.6% and 81.0%, respectively; RR = 1.22; p = 0.002). CONCLUSION: Although both techniques seem to be similar in detecting patients with advanced colorectal neoplasms, CCE is more sensitive for the detection of any neoplastic lesion. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT02081742 . Registered: September 16, 2013.


Assuntos
Endoscopia por Cápsula/métodos , Colonografia Tomográfica Computadorizada/métodos , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/diagnóstico , Detecção Precoce de Câncer/métodos , Programas de Rastreamento/métodos , Neoplasias Colorretais/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
9.
Surg Endosc ; 34(4): 1887-1889, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32048018

RESUMO

BACKGROUND: Content-based image retrieval (CBIR) is an application of machine learning used to retrieve images by similarity on the basis of features. Our objective was to develop a CBIR system that could identify images containing the same polyp ('polyp fingerprint'). METHODS: A machine learning technique called Bag of Words was used to describe each endoscopic image containing a polyp in a unique way. The system was tested with 243 white light images belonging to 99 different polyps (for each polyp there were at least two images representing it in two different temporal moments). Images were acquired in routine colonoscopies at Hospital Clínic using high-definition Olympus endoscopes. The method provided for each image the closest match within the dataset. RESULTS: The system matched another image of the same polyp in 221/243 cases (91%). No differences were observed in the number of correct matches according to Paris classification (protruded: 90.7% vs. non-protruded: 91.3%) and size (< 10 mm: 91.6% vs. > 10 mm: 90%). CONCLUSIONS: A CBIR system can match accurately two images containing the same polyp, which could be a helpful aid for polyp image recognition.


Assuntos
Pólipos do Colo/diagnóstico por imagem , Colonoscopia/métodos , Interpretação de Imagem Assistida por Computador/métodos , Armazenamento e Recuperação da Informação/métodos , Aprendizado de Máquina , Humanos
10.
Gastroenterol Hepatol ; 43(4): 222-232, 2020 Apr.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32143918

RESUMO

Computer-aided diagnosis (CAD) is a tool with great potential to help endoscopists in the tasks of detecting and histologically classifying colorectal polyps. In recent years, different technologies have been described and their potential utility has been increasingly evidenced, which has generated great expectations among scientific societies. However, most of these works are retrospective and use images of different quality and characteristics which are analysed off line. This review aims to familiarise gastroenterologists with computational methods and the particularities of endoscopic imaging, which have an impact on image processing analysis. Finally, the publicly available image databases, needed to compare and confirm the results obtained with different methods, are presented.


Assuntos
Pólipos do Colo/diagnóstico por imagem , Colonoscopia/métodos , Diagnóstico por Computador/métodos , Pólipos do Colo/patologia , Bases de Dados Factuais , Humanos , Aprendizado de Máquina , Reprodutibilidade dos Testes
11.
Gastroenterol Hepatol ; 43(1): 46-56, 2020 Jan.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-31813615

RESUMO

Colorectal cancer is a major health problem. An improvement to its survival has been demonstrated by performing colonoscopy screenings and removing its precursor lesions: polyps. However, colonoscopy is not infallible and multiple strategies have been proposed aimed at improving the quality thereof. This report describes the endoscopic systems available to improve the detection and characterization of polyps, the different classifications for histological prediction and the current indications of advanced endoscopic diagnostic techniques.


Assuntos
Pólipos do Colo/diagnóstico por imagem , Colonoscópios/normas , Colonoscopia/métodos , Pólipos Intestinais/diagnóstico por imagem , Lesões Pré-Cancerosas/diagnóstico por imagem , Doenças Retais/diagnóstico por imagem , Colonoscopia/instrumentação , Neoplasias Colorretais/diagnóstico por imagem , Desenho de Equipamento , Humanos , Pólipos Intestinais/classificação
12.
Gastroenterol Hepatol ; 43(10): 589-597, 2020 Dec.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32674879

RESUMO

INTRODUCTION: In a previous study we demonstrated that a simple training programme improved quality indicators of Oesophagogastroduodenoscopy (OGD) achieving the recommended benchmarks. However, the long-term effect of this intervention is unknown. The aim of this study was to assess the quality of OGDs performed 3 years after of having completed a training programme. MATERIAL AND METHODS: A comparative study of 2 cohorts was designed as follows: Group A included OGDs performed in 2016 promptly after a training programme and Group B with OGDs performed from January to March 2019, this group was also divided into 2 subgroups: subgroup B1 of Endoscopists who had participated in the previous training programme and subgroup B2 of Endoscopists who had not. The intra-procedure quality indicators proposed by ASGE-ACG were used. RESULTS: A total of 1236 OGDs were analysed, 600 from Group A and 636 from Group B (439 subgroup B1 and 197 subgroup B2). The number of complete examinations was lower in Group B (566 [94.3%] vs. 551 [86.6%]; p<0.001). A significant decrease was observed in nearly all quality indicators and they did not reach the recommended benchmarks: retroflexion in the stomach (96% vs. 81%; p<0.001); Seattle biopsy protocol (86% vs. 50%; p=0.03), description of the upper GI bleeding lesion (100% vs. 62%; p<0.01), sufficient intestinal biopsy specimens (at least 4) in suspected coeliac disease (92.5% vs. 18%; p<0.001), photo documentation of the lesion (94% vs. 90%; p<0.05). Regarding the overall assessment of the procedure (including correct performance and adequate photo documentation), a significant decrease was also observed (90.5% vs. 62%; p<0.001). There were no differences between subgroups B1 and B2. CONCLUSIONS: The improvement observed in 2016 after a training programme did not prevail after 3 years. In order to keep the quality of OGDs above the recommended benchmarks, it is necessary to implement continuous training programmes.


Assuntos
Benchmarking , Duodenoscopia/normas , Esofagoscopia/normas , Gastroscopia/normas , Indicadores de Qualidade em Assistência à Saúde/normas , Biópsia/normas , Doença Celíaca/patologia , Estudos de Coortes , Duodenoscopia/educação , Duodenoscopia/estatística & dados numéricos , Esofagoscopia/educação , Esofagoscopia/estatística & dados numéricos , Hemorragia Gastrointestinal/diagnóstico por imagem , Gastroscopia/educação , Gastroscopia/estatística & dados numéricos , Humanos , Intestinos/patologia , Fotografação , Desenvolvimento de Programas , Padrões de Referência , Sociedades Médicas , Fatores de Tempo
13.
Gastrointest Endosc ; 90(3): 461-466, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31108089

RESUMO

BACKGROUND AND AIMS: Helicobacter pylori is the major cause of gastritis and gastritis-associated diseases. Detection of a regular arrangement of collecting venules (RAC) in the lesser gastric curvature correlates with negative H pylori status with a sensitivity and negative predictive value (NPV) higher than 90% in Asian countries. The aim of the study was to evaluate the value of RAC as a diagnostic method of H pylori infection in a European population. METHODS: A prospective study with high-definition endoscopes without magnification was performed by 3 endoscopists. The presence of starfish-like minute points regularly distributed throughout the lesser curvature of the gastric body was considered RAC positive (RAC+). Gastric biopsies were performed during the procedure for H pylori diagnosis. RESULTS: One hundred forty patients were included from February 2017 to May 2018. The prevalence of H pylori infection was 31% and 47 of 140 patients (34%) were RAC+; 13 of 23 patients in whom H pylori was eradicated were RAC+. The mean age of RAC+ patients was lower (44.4 vs 52.4 years, P = .004) and they had less- significant endoscopic findings (9; 19.1% vs 38; 80.9%; P = .017). Gender, use of nonsteroidal anti-inflammatory drugs, antithrombotic or anticoagulants treatments, and a history of H pylori eradication did not show differences in the RAC pattern. The absence of RAC was associated with H pylori infection in 47.3% (44/93) of cases. In contrast, all RAC+ patients were free of H pylori infection, with sensitivity and NPV of 100% for the exclusion of H pylori infection. CONCLUSION: The presence of RAC+ in the lesser curvature evaluated with high-definition endoscopy can accurately identify patients without H pylori.


Assuntos
Gastroscopia , Infecções por Helicobacter/diagnóstico , Estômago/patologia , Vênulas/patologia , População Branca , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Infecções por Helicobacter/patologia , Helicobacter pylori , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade , Estômago/irrigação sanguínea , Adulto Jovem
14.
Endoscopy ; 51(3): 261-265, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30360010

RESUMO

BACKGROUND: This study aimed to evaluate a new computational histology prediction system based on colorectal polyp textural surface patterns using high definition white light images. METHODS: Textural elements (textons) were characterized according to their contrast with respect to the surface, shape, and number of bifurcations, assuming that dysplastic polyps are associated with highly contrasted, large tubular patterns with some degree of bifurcation. Computer-aided diagnosis (CAD) was compared with pathological diagnosis and the diagnosis made by endoscopists using Kudo and Narrow-Band Imaging International Colorectal Endoscopic classifications. RESULTS: Images of 225 polyps were evaluated (142 dysplastic and 83 nondysplastic). The CAD system correctly classified 205 polyps (91.1 %): 131/142 dysplastic (92.3 %) and 74/83 (89.2 %) nondysplastic. For the subgroup of 100 diminutive polyps (≤ 5 mm), CAD correctly classified 87 polyps (87.0 %): 43/50 (86.0 %) dysplastic and 44/50 (88.0 %) nondysplastic. There were no statistically significant differences in polyp histology prediction between the CAD system and endoscopist assessment. CONCLUSION: A computer vision system based on the characterization of the polyp surface in white light accurately predicted colorectal polyp histology.


Assuntos
Pólipos do Colo/patologia , Colonoscopia/métodos , Diagnóstico por Computador , Imagem de Banda Estreita/métodos , Humanos , Valor Preditivo dos Testes
16.
Pancreatology ; 17(5): 858-864, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28844696

RESUMO

BACKGROUND/OBJECTIVE: To assess the relationship between the presence of ascites detected by endoscopic ultrasonography (EUS) and peritoneal carcinomatosis (PC) in patients with pancreatic adenocarcinoma. METHODS: Consecutive patients who underwent a EUS for preoperative staging of a pancreatic adenocarcinoma between 1998 and 2014 were retrospectively reviewed. The diagnosis of PC was confirmed by histopathology or peritoneal fluid cytology. The main outcome of the study was the relationship of ascites at EUS and PC in patients with pancreatic cancer. Secondarily, to evaluate the relationship between this finding and survival as well as the development of PC during follow-up. RESULTS: A total of 136 patients were included: 30 patients with local unresectable tumor or metastatic disease and 106 potentially-resectable candidates based on CT staging. EUS showed ascites in 27 (20%) patients, of whom 8 (29.6%) had PC. The sensitivity, specificity, PPV, NPV and accuracy of ascites by EUS in the detection of PC in this group of patients were 67%, 85%, 30%, 96% and 83%, respectively. Ascites detected by EUS was the only independent predictive factor of PC with an OR of 11 (CI 95%: 3-40). The detection of ascites by EUS was associated with a shorter survival (median survival time 7,3 months; range 0-60 vs 14.2 months; range 0-140) (p = 0.018) and earlier development of PC during follow-up (median 3.2 months, range 1.4-18.1 vs 12.7 months, range 5.4-54.8; p = 0.003). CONCLUSION: The finding of ascites at EUS in patients with pancreatic adenocarcinoma is highly associated with PC and a poor outcome.


Assuntos
Endossonografia , Laparotomia , Neoplasias Pancreáticas/patologia , Neoplasias Pancreáticas/cirurgia , Neoplasias Peritoneais/diagnóstico , Neoplasias Peritoneais/secundário , Adulto , Idoso , Idoso de 80 Anos ou mais , Ascite/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Cuidados Pré-Operatórios , Reprodutibilidade dos Testes , Estudos Retrospectivos
18.
Gastroenterol Hepatol ; 40(8): 507-514, 2017 Oct.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-28222897

RESUMO

INTRODUCTION: Gastric polyps are usually asymptomatic lesions incidentally discovered during endoscopy. OBJECTIVE: To study the frequency of different types of gastric polyps in our population and their possible association with other factors. PATIENTS AND METHODS: Retrospective study of gastroscopies performed in a tertiary hospital over a ten-year period. Demographics, medical history, indication for gastroscopy and morphological and histological characteristics of polyps were collected. RESULTS: Gastric polyps were found in 827 out of 41253 (2%) reviewed gastroscopies, corresponding to 709 patients. Mean age was 65.6 years, and 62% were female. 53.9% of patients had multiple polyps. The most common location was the fundus and 83.3% were smaller than 1cm. Histopathology was obtained in 607 patients: hyperplastic polyps were the most common (42.8%), followed by fundic gland polyps (37.7%). Factors independently associated with hyperplastic polyps were age and single polyp, size ≥6mm and location other than fundus. In contrast, fundic gland polyps were associated with reflux and multiple polyps, size <6mm and located in fundus. Adenomas were independently associated with single polyp. CONCLUSIONS: Fundic gland and hyperplastic polyps are the most common in our population and have characteristic features that can guide histological diagnosis. With single polyps it is advisable to take biopsies to rule out adenoma.


Assuntos
Pólipos/epidemiologia , Gastropatias/epidemiologia , Pólipos Adenomatosos/diagnóstico , Pólipos Adenomatosos/epidemiologia , Pólipos Adenomatosos/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Comorbidade , Feminino , Fundo Gástrico/patologia , Refluxo Gastroesofágico/epidemiologia , Gastroscopia , Humanos , Hiperplasia , Pólipos Intestinais/epidemiologia , Masculino , Pessoa de Meia-Idade , Pólipos/diagnóstico , Pólipos/patologia , Estudos Retrospectivos , Espanha/epidemiologia , Gastropatias/diagnóstico , Gastropatias/patologia , Neoplasias Gástricas/diagnóstico , Neoplasias Gástricas/epidemiologia , Neoplasias Gástricas/patologia , Adulto Jovem
19.
Gastroenterol Hepatol ; 40(9): 587-594, 2017 Nov.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-28648767

RESUMO

INTRODUCTION: There is an opportunity for improvement in the recording and measuring of quality indicators. However, no previous experiences exist in our field in terms of their compliance in esophagogastroduodenoscopy (EGD). OBJECTIVE: To analyse compliance with EGD quality criteria and evaluate improvement after conducting a training programme. PATIENTS AND METHODS: Comparative study of 2 cohorts: one retrospective (control group) and one prospective (intervention group), before and after a training programme consisting of an information session and the report writing improvement programme. The quality indicators proposed by the American Society for Gastrointestinal Endoscopy and the American College of Gastroenterology were used. RESULTS: A total of 1,200 EGDs were included in a sequential manner (600 in each group). Following the training programme, a significant improvement was observed in the following indicators: documented indication (93 vs. 99.8%; P<0.01), documented full examinations (94.7 vs. 97.3%; P<0.01), correct performance (63.7 vs. 87.9%; P<0.01), appropriate biopsies according to protocols (57.9 vs. 83.8%; P<0.01), photo-documentation of described lesions (84.1 vs. 94.9%; P<0.01), photo-documentation per segment (52.9 vs. 70.5%; P<0.01) and correct overall assessment (56,9 vs. 90.5%; P<0.01). Biopsies for coeliac disease, documented indication, full examination and correct performance, if it went ahead, exceeded the recommended standard. CONCLUSION: A very simple training programme improves EGD quality indicators, with the majority reaching the standards recommended by the American Society for Gastrointestinal Endoscopy and the American College of Gastroenterology.


Assuntos
Endoscopia do Sistema Digestório/normas , Indicadores de Qualidade em Assistência à Saúde , Humanos , Avaliação de Programas e Projetos de Saúde , Estudos Prospectivos , Melhoria de Qualidade , Estudos Retrospectivos , Centros de Atenção Terciária , Resultado do Tratamento , Estados Unidos
20.
Gastrointest Endosc ; 83(4): 780-4, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26301408

RESUMO

BACKGROUND AND AIMS: Pancreatic cysts and solid lesions are routinely examined by EUS-guided FNA (EUS-FNA). The aim of this study was to compare the incidence of adverse events (AEs) of this procedure by using the lexicon recommended by the American Society for Gastrointestinal Endoscopy (ASGE). METHODS: This was a prospective and comparative study of patients who underwent EUS-FNA in which a 22-gauge needle was used. In the pancreatic cystic lesions group (group I), complete fluid evacuation in a single needle pass was attempted, and ciprofloxacin was given during the procedure and for 3 days after. In the pancreatic solid lesions group (group II), the number of passes was determined by the on-site evaluation of the sample. AEs were defined and graded according to the lexicon recommended by the ASGE. Patients were followed for 48 hours, 1 week, and 1 month after the procedure. RESULTS: A total of 146 patients were included, 73 in group I and 73 in group II. Potential factors influencing the incidence of AEs (ie, access route for FNA) were similar in both groups. AEs occurred in 5 of 146 patients (3.4%; 95% confidence interval [CI], 1.3%-8%): 4 in group I (5.5%; 95% CI, 1.7%-13.7%) and 1 in group II (1.4%; 95% CI, -0.5% to 8.1%) (P = .03). Severity was mild in 1 of 5 patients (20%) and moderate in 3 of 5 patients (60%). One patient with a solid mass in the head of the pancreas had a duodenal perforation after EUS and died after surgery. All other AEs occurred in the first 48 hours and resolved with medical therapy. There were 3 incidents of transient hypoxia and self-limited abdominal pain in 1 and 2 patients, respectively. No patients were lost to follow-up. CONCLUSION: EUS-FNA of pancreatic cysts has an AEs rate similar to that of solid pancreatic masses, which is small enough to consider this procedure a safe and effective method for managing patients with both types of lesions. AEs occurred early after EUS-FNA, and patients should be closely followed during the first 2 days after the procedure.


Assuntos
Duodenopatias/etiologia , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/efeitos adversos , Endoscopia Gastrointestinal , Perfuração Intestinal/etiologia , Cisto Pancreático/patologia , Neoplasias Pancreáticas/patologia , Sociedades Médicas , Terminologia como Assunto , Dor Abdominal/etiologia , Idoso , Feminino , Humanos , Hipóxia/etiologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA