Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 22(15)2022 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-35957259

RESUMO

In this paper, we present the development of a multicarrier modulation system of low complexity for broadband underwater acoustic communications (UAC), whose frequency band is located in the ultrasonic range, specifically between 32 kHz and 128 kHz. Underwater acoustic channels are recognized among the most hostile communication channels due to their strong time and frequency selectivity and, hence, the design of high-performance systems is a challenge that is difficult to resolve at the present time with state-of-art technology. The aim of the proposed system is to reach a reasonable bit rate, between 40 and 50 Kbps, over these channels that allows, for instance, the transmission of video signals of limited quality. We describe an orthogonal frequency division multiplexing (OFDM) modem prototype with a parameter setting and design specifically adapted to the channel nature. For this purpose, actual measurements carried out at the Mediterranean sea, on shallow waters, have been used to evaluate the system performance and to optimize the design. A discussion on several modulations and OFDM configurations is presented that leads to the selection of differential and non-differential quadri-phase shift keying (QPSK) as good candidates depending on synchronization capabilities.

2.
Sensors (Basel) ; 22(17)2022 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-36080970

RESUMO

The purpose of this work is to present a flexible system that supports the study of wideband underwater acoustic communications (UAC). It has been developed both to measure channels and to test transmission techniques under realistic conditions in the ultrasonic band. This platform consists of a hardware (HW) part that includes multiple hydrophones, projectors, analog front-ends, acquisition boards, and computers, and a software (SW) part for the generation, reception, and management of acoustic sounding signals and noise. UAC channels are among the most hostile ones and exhibit an important attenuation and distortion, essentially due to both multipath propagation, which results in a very long channel impulse response, and time-varying behavior, which produces a notable Doppler spread. To cope with this challenging medium, sophisticated transmission techniques must be employed. In this sense, adequate signal processing algorithms have been designed aiming not only at the analysis and characterization of underwater communication channels but also at the evaluation of diverse modulation, detection, and coding schemes, from Orthogonal Frequency Division Multiplexing (OFDM) to single-carrier digital modulations with a single-input multiple-output (SIMO) configuration that takes advantage of diversity techniques. Wideband sounding signals, to be injected into the sea from the transmitter side, are created with patterns that allow multiple tests on a batch. With offline processing of the captured data at the receiver side, different trials can be carried out in a very flexible manner. The different aspects of the platform are described in detail: the HW equipment used, the SW interface to control acquisition boards, and the signal processing algorithms to estimate the UAC channel response. The platform allows the analysis and design of new proposals for underwater communications systems that improve the performance of the current ones.


Assuntos
Modelos Teóricos , Ultrassom , Comunicação , Computadores , Software
3.
Sensors (Basel) ; 21(6)2021 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-33807104

RESUMO

Over the last few years, the use of smartwatches in automatic Fall Detection Systems (FDSs) has aroused great interest in the research of new wearable telemonitoring systems for the elderly. In contrast with other approaches to the problem of fall detection, smartwatch-based FDSs can benefit from the widespread acceptance, ergonomics, low cost, networking interfaces, and sensors that these devices provide. However, the scientific literature has shown that, due to the freedom of movement of the arms, the wrist is usually not the most appropriate position to unambiguously characterize the dynamics of the human body during falls, as many conventional activities of daily living that involve a vigorous motion of the hands may be easily misinterpreted as falls. As also stated by the literature, sensor-fusion and multi-point measurements are required to define a robust and reliable method for a wearable FDS. Thus, to avoid false alarms, it may be necessary to combine the analysis of the signals captured by the smartwatch with those collected by some other low-power sensor placed at a point closer to the body's center of gravity (e.g., on the waist). Under this architecture of Body Area Network (BAN), these external sensing nodes must be wirelessly connected to the smartwatch to transmit their measurements. Nonetheless, the deployment of this networking solution, in which the smartwatch is in charge of processing the sensed data and generating the alarm in case of detecting a fall, may severely impact on the performance of the wearable. Unlike many other works (which often neglect the operational aspects of real fall detectors), this paper analyzes the actual feasibility of putting into effect a BAN intended for fall detection on present commercial smartwatches. In particular, the study is focused on evaluating the reduction of the battery life may cause in the watch that works as the core of the BAN. To this end, we thoroughly assess the energy drain in a prototype of an FDS consisting of a smartwatch and several external Bluetooth-enabled sensing units. In order to identify those scenarios in which the use of the smartwatch could be viable from a practical point of view, the testbed is studied with diverse commercial devices and under different configurations of those elements that may significantly hamper the battery lifetime.


Assuntos
Acidentes por Quedas , Dispositivos Eletrônicos Vestíveis , Acidentes por Quedas/prevenção & controle , Atividades Cotidianas , Idoso , Estudos de Viabilidade , Humanos , Movimento (Física)
4.
Sensors (Basel) ; 21(15)2021 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-34372260

RESUMO

We report the results of a study on the learnability of the locations of haptic icons on smartphones. The aim was to study the influence of the use of complex and different vibration patterns associated with haptic icons compared to the use of simple and equal vibrations on commercial location-assistance applications. We studied the performance of users with different visual capacities (visually impaired vs. sighted) in terms of the time taken to learn the icons' locations and the icon recognition rate. We also took into consideration the users' satisfaction with the application developed to perform the study. The experiments concluded that the use of complex and different instead of simple and equal vibration patterns obtains better recognition rates. This improvement is even more noticeable for visually impaired users, who obtain results comparable to those achieved by sighted users.


Assuntos
Aprendizagem , Smartphone , Humanos , Satisfação Pessoal , Vibração
5.
Sensors (Basel) ; 20(3)2020 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-31979189

RESUMO

Fall Detection Systems (FDSs) based on wearable technologies have gained much research attention in recent years. Due to the networking and computing capabilities of smartphones, these widespread personal devices have been proposed to deploy cost-effective wearable systems intended for automatic fall detection. In spite of the fact that smartphones are natively provided with inertial sensors (accelerometers and gyroscopes), the effectiveness of a smartphone-based FDS can be improved if it also exploits the measurements collected by small low-power wireless sensors, which can be firmly attached to the user's body without causing discomfort. For these architectures with multiple sensing points, the smartphone transported by the user can act as the core of the FDS architecture by processing and analyzing the data measured by the external sensors and transmitting the corresponding alarm whenever a fall is detected. In this context, the wireless communications with the sensors and with the remote monitoring point may impact on the general performance of the smartphone and, in particular, on the battery lifetime. In contrast with most works in the literature (which disregard the real feasibility of implementing an FDS on a smartphone), this paper explores the actual potential of current commercial smartphones to put into operation an FDS that incorporates several external sensors. This study analyzes diverse operational aspects that may influence the consumption (as the use of a GPS sensor, the coexistence with other apps, the retransmission of the measurements to an external server, etc.) and identifies practical scenarios in which the deployment of a smartphone-based FDS is viable.


Assuntos
Acidentes por Quedas , Monitorização Ambulatorial/instrumentação , Monitorização Ambulatorial/métodos , Smartphone , Humanos , Dispositivos Eletrônicos Vestíveis
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA