Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
AJR Am J Roentgenol ; 216(5): 1216-1221, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33624522

RESUMO

OBJECTIVE. This study aimed to evaluate the long-term prognostic value of coronary CTA (CCTA) in heart transplant recipients. MATERIALS AND METHODS. The records of 114 patients who had undergone a heart transplant (mean age, 61.7 ± 11.1 [SD] years; 83.3% men) and who underwent CCTA for the surveillance of coronary allograft vasculopathy (CAV) from June 2007 to December 2017 were retrospectively evaluated for the occurrence of major adverse cardiovascular events (MACEs) (cardiac death, nonfatal myocardial infarction, unstable angina requiring hospitalization, coronary revascularization, cardiac arrhythmias, stroke, and retransplant). Patients were classified according to the presence of nonobstructive CAV (lumen reduction < 50%) or obstructive disease (lumen reduction ≥ 50%) and using a coronary segment involvement score (SIS). Differences in MACE rate between groups were compared. RESULTS. Obstructive CAV was observed in 12 heart transplant recipients (10.5%). During a mean follow-up of 67.5 ± 41.4 months the overall rates of MACE were 50% and 14.7% in patients with obstructive and nonobstructive CAV, respectively (p < .05), resulting in an odds ratio for MACE of 6 (95% CI, 1.7-21.2). Comparison of event-free survival showed a hazard ratio (HR) of 5 (95% CI, 1.95-13; p =. 004) for patients with obstructive disease. The presence of four or more stenotic coronary segments (SIS ≥ 4) was associated with a higher rate of events (HR, 3.46; 95% CI, 1.46-8.23). CONCLUSION. In patients who have undergone a heart transplant, CCTA offers a significant long-term prognostic impact on the prediction of MACEs.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Transplante de Coração , Complicações Pós-Operatórias/diagnóstico por imagem , Idoso , Feminino , Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos
2.
AJR Am J Roentgenol ; 215(4): 828-833, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32783558

RESUMO

OBJECTIVE. The purpose of this study was to evaluate the feasibility, image quality, and radiation dose of high-pitch coronary CT angiography (CCTA) in orthotopic heart transplant (OHT) recipients. SUBJECTS AND METHODS. Twenty-two consecutive OHT recipients (16 men, six women; median age, 66.5 years [interquartile range, 51.3-70.3 years]; median heart rate, 91 beats/min [interquartile range, 79.3-97.3 beats/min]) underwent CCTA with a third-generation dual-source CT scanner in high-pitch mode to rule out coronary allograft vasculopathy. Data acquisition was triggered at 30% of the R-R interval. Two independent observers blindly assessed image quality on a per-segment, per-vessel, and per-patient basis using a 4-point scale (4, excellent; 1, not evaluative). Scores 2-4 indicated diagnostic quality. Studies were compared with previously performed retrospective ECG-gated examinations, when available. Interobserver agreement on the image quality was assessed with kappa statistics. Radiation dose was recorded. RESULTS. A total of 322 coronary segments were evaluated. Diagnostic image quality was observed in 97.5% of the segments. Interobserver agreement for image quality assessment was very good on a per-patient (κ = 0.82), per-vessel (κ = 0.83), and per-segment basis (κ = 0.89). The median per-patient image quality score was 4.0 (3.0-4.0) for the entire coronary tree. A comparison of image quality scores between high-pitch and retrospective ECG-gated CCTA examinations showed no significant differences, but the estimated mean radiation dose was significantly lower for the high-pitch mode (median dose-length product, 31.6 mGy × cm [interquartile range, 23.1-38.8 mGy × cm] vs 736.5 mGy × cm [interquartile range, 655.5-845.7 mGy × cm], p < 0.001). CONCLUSION. Performing single-heartbeat high-pitch CCTA during the systolic phase of the cardiac cycle in OHT recipients results in diagnostic image quality in coronary angiograms at very low radiation dose.


Assuntos
Angiografia por Tomografia Computadorizada , Estenose Coronária/diagnóstico por imagem , Transplante de Coração/efeitos adversos , Processamento de Imagem Assistida por Computador , Idoso , Estudos de Coortes , Estenose Coronária/etiologia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Reprodutibilidade dos Testes , Sístole
3.
Acta Radiol ; 58(6): 645-651, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28273729

RESUMO

Background Digital breast tomosynthesis (DBT) and ultrasound (US) can detect additional cancers after negative mammography. However, not all cancers are visible by both techniques. Purpose To study the role of the amount of peritumoral fat in the detection of additional cancers with DBT or US. Material and Methods One reader retrospectively reviewed 142 breast cancers in 109 women who underwent mammography, DBT, US, and magnetic resonance imaging (MRI). Two readers in consensus evaluated the additional cancers detected by US, DBT, or MRI, and classified them into four groups according to the amount of peritumoral adipose tissue: group I, >75% of peritumoral fat; group II, 50-74%; group III, 25-49%, and group IV, 0-24%. The detection of additional cancers by US and DBT with respect to the other imaging techniques was evaluated. Results Seventy-eight cancers were detected by mammography and the remaining 64 cancers were detected by DBT, US, or MRI. US and DBT detected 46 (71.8%) and 25 (39.06%) additional tumors, respectively. Statistical significance was only found in group IV ( P < 0.01). Conclusion US detected more tumors than DBT in lesions surrounded by a small amount of fat. No significant differences were found between US and DBT in the detection of additional cancers in the other groups.


Assuntos
Tecido Adiposo/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Mamografia , Neoplasias Primárias Múltiplas/diagnóstico por imagem , Neoplasias Primárias Múltiplas/patologia , Ultrassonografia Mamária , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
4.
Acta Radiol ; 58(7): 809-815, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27794025

RESUMO

Background Diffuse myocardial fibrosis can be quantified by calculating extra-cellular volume (ECV) from native and post-contrast T1 values using dedicated single bolus contrast medium injection protocols. Purpose To evaluate differences in T1 maps and myocardial ECV measurements in routine stress/rest perfusion cardiovascular magnetic resonance (CMR) examinations after injection of single and double dose of contrast medium. Material and Methods Thirty-seven consecutive patients (30 men; mean age, 62 ± 13 years) underwent clinically indicated adenosine stress/rest perfusion CMR examination to rule out myocardial ischemia following a conventional split-dose contrast medium injection strategy. Native and post-contrast T1 mapping was performed 15 min after the first (0.1 mmol/kg) and second (0.1 mmol/kg) dose of contrast medium using a breath-held Modified Look-Locker Inversion recovery (MOLLI) sequence. Student's t-test for paired samples, Bland-Altman plots, and concordance-correlation coefficients (CCC) for agreement between T1 and ECV calculations after single and double dose of contrast medium were calculated. Intra- and inter-observer agreement for measurements was also analyzed. Results Myocardial T1 values after single and double dose of contrast medium significantly differed (mean difference of 114.1 ± 19.9 ms, P < 0.01). A single dose of contrast agent provided slightly higher ECV values (mean difference of 2.3 ± 1.1%). CCC for ECV calculations was 0.66. Intra- and inter-observer agreement for all measurements was excellent (CCC ≥ 0.83). Conclusion Quantification of myocardial ECV on conventional stress/rest perfusion CMR examination is feasible. T1 maps obtained 15 min after 0.1 mmol/kg of contrast medium provide slightly higher myocardial T1 measurements and ECV values compared with T1 maps obtained after a total dose of 0.2 mmol/kg.


Assuntos
Técnicas de Imagem Cardíaca , Meios de Contraste/administração & dosagem , Teste de Esforço , Espaço Extracelular/diagnóstico por imagem , Imageamento por Ressonância Magnética , Miocárdio/patologia , Adenosina , Circulação Coronária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Descanso , Vasodilatadores
5.
Acta Radiol ; 57(1): 13-8, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25523063

RESUMO

BACKGROUND: Digital mammography (DM) is widespread used for the detection of breast cancer, but its sensitivity drops in dense breasts. It is well known that additional breast ultrasound (US) and digital breast tomosynthesis (DBT) increase the sensitivity of DM. However, to our knowledge, there are no articles comparing the role of both additional techniques. PURPOSE: To assess the diagnostic performance of DM and the different combinations of DM + additional DBT and DM + additional US in an enriched sample of patients. MATERIAL AND METHODS: Retrospective study in an enriched sample of 1042 patients. Out of them, 84 patients had histologically proven malignant lesions and 258 patients had benign lesions. Finally 700 patients with normal explorations or benign lesions without biopsy confirmation (but stable for at least 12 months) were included. All of them underwent DM, US, and DBT examinations that were retrospectively reviewed by one expert radiologist, blinded to the final diagnoses. The DBT examinations were performed using one single view with wide angle (50°). The reader categorized the cases as benign (BI-RADS 1 or 2) or malignant (BI-RADS 3-5) for DM and the different combination of techniques. The sensitivity (SE) and specificity (SP) were calculated with the PEPI software and the ROC curves of the different techniques and combinations were calculated by using the SPSS 15.0 software. RESULTS: The SE and SP of DM were 69.05% and 88.20%, respectively. Additional DBT significantly increased the AUC of DM as well as additional US or the combination DM + DBT + US (P < 0.05). However there were no significant differences between the AUC of DM + US and DM + DBT (P = 0.7). CONCLUSION: Additional US, DBT, or both, in combination with DM, significantly increased the AUC of DM. However, there were no significant differences between DM + DBT and DM + US.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mamografia , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador , Ultrassonografia Mamária/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
6.
Int J Cardiovasc Imaging ; 39(9): 1765-1774, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37354385

RESUMO

Owing to its pharmacodynamics and posology, the use of regadenoson for stress cardiac magnetic resonance (CMR) has potential advantages over other vasodilators. We sought to evaluate the safety, hemodynamic response and diagnostic performance of regadenoson stress-CMR in routine clinical practice. All regadenoson stress-CMR examinations performed between May 2017 and July 2020 at our institution were retrospectively reviewed. A total of 698 studies were included for the final analysis. A conventional stress/rest protocol was performed using a 1.5T MRI scanner (Magnetom Aera, Siemens Healthineers, Erlangen, Germany). Adverse events, clinical symptoms, and hemodynamic response were assessed. Diagnostic accuracy of the test was evaluated in patients who underwent invasive coronary angiography. Nearly half of patients (48.5%) remained asymptomatic. Most common clinical symptoms included dyspnea (137, 19.6%), chest pain (116, 16.6%) and flushing (44, 6.3%). Two patients (0.28%) could not complete the examination due to severe hypotension or unbearable chest pain. Overall, an increase in heart rate (HR) response (36.2% [IQR: 22.5?50.9]) and a decrease in systolic and diastolic blood pressure (BP) (median systolic BP response of -5% [IQR: -11.5-0.6]; median diastolic BP response of -6.3 mmHg [IQR: -13.4-0]) was observed. Patients with symptoms induced by regadenoson showed higher HR response (40.3%, IQR: 26.4?56.1 vs. 32.4%, IQR: 19-45.6, p < 0.001), whereas a blunted HR response was observed in diabetic (29.6%, IQR: 18.4?42 p < 0.001), obese (31.7%, IQR: 20.7?46.2 p = 0.005) and patients aged 70 years or older (32.9%, IQR: 22.6?43.1 p < 0.001). Overall, regadenoson stress-CMR showed 95.65% (IQ 91.49?99.81) sensitivity, 54.84% (IQ 35.71?73.97) specificity, 86.99% (IQ 82.74?94.68) positive predictive value, and 77.27% (IQ 57.49?97.06) negative predictive value for detecting significant coronary stenosis as compared with invasive coronary angiography. Regadenoson is a well-tolerated vasodilator that can be safely employed for stress perfusion CMR, with high diagnostic performance.


Assuntos
Imageamento por Ressonância Magnética , Imagem de Perfusão do Miocárdio , Humanos , Estudos Retrospectivos , Estudos de Viabilidade , Valor Preditivo dos Testes , Imageamento por Ressonância Magnética/métodos , Vasodilatadores/efeitos adversos , Hemodinâmica , Perfusão , Espectroscopia de Ressonância Magnética , Dor no Peito , Imagem de Perfusão do Miocárdio/métodos
7.
J Thorac Imaging ; 35(1): 64-70, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31651691

RESUMO

PURPOSE: Routine manual tracing of cardiac contours is time-consuming and subject to variability. A fully automated software tool may improve reading efficiency. This study was performed to assess the accuracy, reliability, and time-efficiency of a fully automated left ventricular (LV) segmentation software tool to calculate LV volumes and function compared with conventional manual contouring. MATERIALS AND METHODS: Sixty-seven consecutive patients (53 male, mean age 62.5±10.9 y) underwent adenosine stress/rest perfusion cardiac magnetic resonance examination to rule out myocardial ischemia. Double-oblique short-axis 6-mm slice thickness steady-state free precession cine images were acquired to assess LV ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV), and stroke volume (SV) using manual contour tracing and a recently developed fully automated software tool. The length of time needed to obtain LV volumes with each segmentation method was also compared. RESULTS: Compared with manual contouring, the fully automated software tool minimally underestimated LV-EF (mean difference of 2.9%±3.9%) and SV (mean difference of 4.4±8.5 mL) and slightly overestimated ESV (mean difference of -6.4±10.8 mL) and LV mass (mean difference of -14±20.4 g). EDV quantification did not statistically differ. Reliability for EF (concordance correlation coefficient [CCC]=0.92, 95% confidence interval [CI], 0.88-0.95), EDV (CCC=0.98, 95% CI, 0.97-0.99), ESV (CCC=0.96, 95% CI, 0.94-0.97), SV (CCC=0.93, 95% CI, 0.89-0.95), and LV mass (CCC=0.84, 95% CI, 0.76-0.89) was very good. The evaluated software allowed to quantify LV parameters with a 79% reduction in the time required for manual contouring (414.7±91 s vs. 85±16.1 s, respectively, P<0.001). CONCLUSION: Quantification of LV volumes using the evaluated fully automated segmentation software is accurate and time-efficient.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Isquemia Miocárdica/diagnóstico por imagem , Eficiência , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/fisiopatologia , Reprodutibilidade dos Testes , Software
8.
Eur Radiol Exp ; 1(1): 7, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29708175

RESUMO

BACKGROUND: The study was aimed at: (1) describing the incidence of anatomic variations of the portal system in the rabbit using direct portography; and (2) estimating the liver volume and caudate lobe volume by using contrast-enhanced computed tomography (CECT) in the same animal model. METHODS: Forty-six New Zealand white rabbits were included. All of them underwent direct portography and unenhanced CECT. Conventional liver rabbit portal system anatomy (type 1) consisted of the bifurcation of the main portal vein (MPV) into the right portal vein (RPV) and left portal vein (LPV), which subsequently divided into medial left portal vein and lateral left portal vein. Trifurcation of the LPV was considered type 2. The LPV that divides into four smaller branches was classified as type 3. Other configurations of the portal system, including particular cases of MPV branching, were grouped as type 4. Liver lobes were manually segmented. RESULTS: The incidence of each type of portal system anatomy was: type 1, 67.4%; type 2, 15.2%; type 3, 13.0%); and type 4, 4.3%. The mean volume of the caudate lobe was 19.1 ml ± 5.7 ml and of the cranial lobes it was 66.7 ml ± 13.7 ml, and the total liver volume was 85.7 ml ± 16.7 ml. CONCLUSIONS: In New Zealand white rabbits, type 1 is the prevalent type of portal system, liver volume is about 86 ml, and the caudate and cranial lobes are separated. This information could be important when planning experimental rabbit liver procedures.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA