Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Blood Purif ; 52(2): 132-139, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35896087

RESUMO

BACKGROUND: Low-flow extracorporeal carbon dioxide removal (LF-ECCO2R) has the potential to play an important role in the management of adults with acute respiratory failure. However, it has never been tested in China. The study aimed at exploring the safety and efficacy on LF-ECCO2R for acute respiratory failure in a Chinese tertiary intensive care unit (ICU). MATERIALS AND METHODS: We performed a retrospective case note review of patients admitted to our tertiary regional ICU and commenced on LF-ECCO2R from June 2020 to September 2021. The LF-ECCO2R device we used was ProLUNG® system (Estor S.p.A., Milan, Italy). The device employed a nonporous poly-4-methyl-1-pentene membrane lung with a surface area of 1.81 m2 and run at an extracorporeal blood flow between 100 and 450 mL/min. Demographic and physiologic data (including ventilation parameters and arterial blood gases) as well as the outcome of LF-ECCO2R treatment were recorded. RESULTS: A total of 12 cases were included. A statistically significant reduction in respiratory rate, driving pressure, PaCO2, and blood lactate was observed. In addition, there was a statistically significant improvement in pH and PaO2/FiO2. Six out of 12 patients (50%) were discharged alive from ICU. Three complications related to LF-ECCO2R were reported, none resulting in serious adverse outcomes. CONCLUSION: Our clinical series indicated that LF-ECCO2R seemed to be safely applied in patients with acute respiratory failure. The efficacy of CO2 removal as well as the improved respiratory parameters was also observed. However, large-scale randomized clinical trials are needed to confirm the effects.


Assuntos
Síndrome do Desconforto Respiratório , Insuficiência Respiratória , Adulto , Humanos , Dióxido de Carbono , Projetos Piloto , Estudos Retrospectivos , Circulação Extracorpórea/métodos , Respiração Artificial/efeitos adversos , Síndrome do Desconforto Respiratório/etiologia , China , Insuficiência Respiratória/etiologia , Insuficiência Respiratória/terapia
2.
BMC Pulm Med ; 22(1): 459, 2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36456940

RESUMO

BACKGROUND: Diaphragmatic ultrasound has been increasingly used to evaluate diaphragm function. However, current diaphragmatic ultrasound parameters provide indirect estimates of diaphragmatic contractile function, and the predictive value is controversial. Two-dimensional (2D) speckle tracking is an effective technology for measuring tissue deformation and can be used to measure diaphragm longitudinal strain (DLS) to assess diaphragm function. The purpose of this study was to determine the feasibility and reproducibility of DLS quantification by 2D speckle tracking and to determine whether maximal DLS could be used to predict weaning outcomes. METHODS: This study was performed in the intensive care unit of two teaching hospitals, and was divided into two studies. Study A was a prospective study to evaluate the feasibility, reliability, and repeatability of speckle tracking in assessing DLS in healthy subjects and mechanically ventilated patients. Study B was a multicentre retrospective study to assess the use of maximal DLS measured by speckle tracking in predicting weaning outcomes. RESULTS: Twenty-five healthy subjects and twenty mechanically ventilated patients were enrolled in Study A. Diaphragmatic speckle tracking was easily accessible. The intra- and interoperator reliability were good to excellent under conditions of eupnoea, deep breathing, and mechanical ventilation. The intraclass correlation coefficient (ICC) ranged from 0.78 to 0.95. Ninety-six patients (fifty-nine patients were successfully weaned) were included in Study B. DLS exhibited a fair linear relationship with both the diaphragmatic thickening fraction (DTF) (R2 = 0.73, p < 0.0001) and diaphragmatic excursion (DE) (R2 = 0.61, p < 0.0001). For the prediction of successful weaning, the areas under the ROC curves of DLS, diaphragmatic thickening fraction DTF, RSBI, and DE were 0.794, 0.794, 0.723, and 0.728, respectively. The best cut-off value for predicting the weaning success of DLS was less than -21%, which had the highest sensitivity of 89.19% and specificity of 64.41%. CONCLUSIONS: Diaphragmatic strain quantification using speckle tracking is easy to obtain in healthy subjects and mechanically ventilated patients and has a high predictive value for mechanical weaning. However, this method offers no advantage over RSBI. Future research should assess its value as a predictor of weaning. TRIAL REGISTRATION: This study was registered in the Chinese Clinical Trial Register (ChiCTR), ChiCTR2100049816. Registered 10 August 2021. http://www.chictr.org.cn/showproj.aspx?proj=131790.


Assuntos
Diafragma , Humanos , Projetos Piloto , Diafragma/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Prospectivos , Estudos Retrospectivos
3.
Crit Care ; 25(1): 8, 2021 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-33402210

RESUMO

BACKGROUND: Burnout has gained increasing attention worldwide; however, there is a lack of relevant research in China. This study investigated the prevalence and factors associated with burnout in physicians of the intensive care unit (ICU) in mainland China. METHODS: This cross-sectional multicenter study included critical care physicians from all provinces in mainland China (except Tibet). A self-administered survey questionnaire was conducted. It included three parts: demographic information, lifestyle and work information, and the Maslach Burnout Inventory. The levels of burnout were calculated. The factors independently associated with burnout were analyzed by logistic regression. RESULTS: Finally, 1813 intensivists participated in the survey. The participation rate was 90.7%. The prevalence of burnout and severe burnout was 82.1% (1489/1813) and 38.8% (704/1813), respectively. According to the logistic regression analysis, "difficulty in making treatment decisions" was independently associated with burnout [OR = 1.365, CI (1.060, 1.757)]. "Higher number of children" [OR = 0.714, CI (0.519, 0.981)] and higher "income satisfaction" [OR = 0.771, CI (0.619, 0.959)] were independent protective factors against severe burnout. CONCLUSIONS: The burnout rate in ICU physicians in China is high. Difficult treatment decisions, the number of children, and income satisfaction are independently associated with burnout rates among ICU physicians in China. TRIAL REGISTRATION: Burnout syndrome of the Chinese personnel working in intensive care units: a survey in China, ChiCTR-EOC-17013044, registered October 19, 2017. http://www.chictr.org.cn/showproj.aspx?proj=22329 .


Assuntos
Esgotamento Profissional/diagnóstico , Cuidados Críticos/normas , Carga de Trabalho/normas , Adulto , Esgotamento Profissional/epidemiologia , Esgotamento Profissional/psicologia , China/epidemiologia , Cuidados Críticos/métodos , Cuidados Críticos/psicologia , Estudos Transversais , Feminino , Humanos , Satisfação no Emprego , Masculino , Prevalência , Carga de Trabalho/estatística & dados numéricos , Local de Trabalho/psicologia , Local de Trabalho/normas
4.
Crit Care Med ; 48(9): 1289-1295, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32427613

RESUMO

OBJECTIVES: Severe acute respiratory distress syndrome is complicated with coronavirus disease 2019 and extracorporeal membrane oxygenation support may be necessary in severe cases. This study is to summarize the clinical features, extracorporeal membrane oxygenation characteristics, and outcomes of patients with severe acute respiratory syndrome coronavirus 2 pneumonia received extracorporeal membrane oxygenation. DESIGN: Descriptive study from two hospitals. SETTING: The ICUs from university hospitals. PATIENTS: Patients with severe acute respiratory syndrome coronavirus 2 pneumonia received mechanical ventilation, including those underwent extracorporeal membrane oxygenation from Zhongnan Hospital of Wuhan University and Wuhan Pulmonary Hospital from January 8, 2020, to March 31, 2020. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Clinical records, laboratory results, ventilator parameters, and extracorporeal membrane oxygenation-related data were abstracted from the medical records. One-hundred twenty-nine critically ill patients with severe acute respiratory syndrome coronavirus 2 pneumonia were admitted to ICU of the two referral hospitals. Fifty-nine patients received mechanical ventilation and 21 of them received extracorporeal membrane oxygenation support (fourteen from Zhongnan hospital and seven from Wuhan pulmonary hospital). Compared to mechanical ventilation patients without extracorporeal membrane oxygenation support, there was a tendency of decline in mortality but with no significant difference (no-extracorporeal membrane oxygenation group 24/38 [63.2%] vs extracorporeal membrane oxygenation group 12/21 [57.1%]; p = 0.782). For those patients with extracorporeal membrane oxygenation, 12 patients died and nine survived by April 7, 2020. Among extracorporeal membrane oxygenation patients, the PaCO2 prior to extracorporeal membrane oxygenation was lower (54.40 mm Hg [29.20-57.50 mm Hg] vs 63.20 mm Hg [55.40-72.12 mm Hg]; p = 0.006), and pH prior to extracorporeal membrane oxygenation was higher (7.38 [7.28-7.48] vs 7.23 [7.16-7.33]; p = 0.023) in survivors than nonsurvivors. CONCLUSIONS: Extracorporeal membrane oxygenation might be an effective salvage treatment for patients with severe acute respiratory syndrome coronavirus 2 pneumonia associated with severe acute respiratory distress syndrome. Severe CO2 retention and acidosis prior to extracorporeal membrane oxygenation indicated a poor prognosis.


Assuntos
Betacoronavirus , Infecções por Coronavirus/terapia , Oxigenação por Membrana Extracorpórea , Pneumonia Viral/terapia , Síndrome do Desconforto Respiratório/terapia , Idoso , COVID-19 , Teste para COVID-19 , Técnicas de Laboratório Clínico , Infecções por Coronavirus/complicações , Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/mortalidade , Oxigenação por Membrana Extracorpórea/efeitos adversos , Oxigenação por Membrana Extracorpórea/mortalidade , Feminino , Hospitais Universitários , Humanos , Unidades de Terapia Intensiva , Masculino , Pessoa de Meia-Idade , Pandemias , Pneumonia Viral/complicações , Pneumonia Viral/mortalidade , Prognóstico , Respiração Artificial , Síndrome do Desconforto Respiratório/etiologia , Testes de Função Respiratória , SARS-CoV-2
5.
Colloids Surf B Biointerfaces ; 222: 113114, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36577345

RESUMO

The monodisperse double emulsions obtained by microfluidic method can serve as ideal templates for preparing core-shell alginate microcapsules, which have attracted much attention in biological applications, such as drug delivery systems and cell encapsulation, tissue engineering. However, the formation behavior and dynamic analysis of double emulsion with an alginate shell is still unclear due to the complex rheological behavior of alginate solutions. Herein, we employ a dual-coaxial microfluidic device to generate the high-quality double emulsion droplets with alginate shell, focusing on the effects of the fluid properties of alginate solution in the middle phase (viscosity, µm) and the fluid flow rate on the droplet formation mechanism. As the viscosity of the middle fluid (µm) increased, the size of compound droplets (D2) increased and the size of inner droplets (D1) decreased, and the break-up regimes occurred a dripping-to-jetting transition when µm = 160 mPa s. The number of encapsulated inner droplets can be predicted and precisely controlled by regulating the generation frequency of inner (f1) and outer droplets (f2). The breakup dynamics of the alginate thread are also analyzed by using the volume-of-fluid/continuum-surface-force (VOF/CSF) method. The results show that the pressure and velocity in the neck of pinch-off is lower in the jetting than that in the dripping regime. This study will provide useful guidance for the rational design and controllable preparation of core-shell alginate microcapsules.


Assuntos
Alginatos , Microfluídica , Microfluídica/métodos , Emulsões , Cápsulas , Reologia
6.
Shock ; 59(1): 66-73, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-36378229

RESUMO

ABSTRACT: Background: The purpose of this study was to determine the feasibility, reliability, and reproducibility of parasternal intercostal muscle longitudinal strain (LSim) quantification by speckle tracking and the value of maximal LSim to predict weaning outcomes. Methods: This study was divided into three phases. Phases 1 and 2 comprehended prospective observational programs to evaluate the feasibility, reliability, and repeatability of speckle tracking to assess LSim in healthy subjects and mechanically ventilated patients. Phase 3 was a multicenter retrospective study to evaluate the value of maximal LSim, intercostal muscle thickening fraction (TFim), diaphragmatic thickening fraction, diaphragmatic excursion, and rapid shallow breathing index to predict weaning outcomes. Results: A total of 25 healthy subjects and 20 mechanically ventilated patients were enrolled in phases 1 and 2, respectively. Maximal LSim was easily accessible, and the intraoperator reliability and interoperator reliability were excellent in eupnea, deep breathing, and mechanical ventilation. The intraclass correlation coefficient ranged from 0.85 to 0.96. Moreover, 83 patients were included in phase 3. The areas under the receiver operating characteristic curve of maximal LSim, TFim, diaphragmatic thickening fraction, diaphragmatic excursion, and rapid shallow breathing index were 0.91, 0.79, 0.71, 0.70, and 0.78 for the prediction of successful weaning, respectively. The best cutoff values of LSim and TFim were >-6% (sensitivity, 100%; specificity, 64.71%) and <7.6% (sensitivity, 100%; specificity, 50.98%), respectively. Conclusions: The quantification of LSim by speckle tracking was easily achievable in healthy subjects and mechanically ventilated patients and presented a higher predictive value for weaning success compared with conventional weaning parameters. Trial registration no. ChiCTR2100049817.


Assuntos
Músculos Intercostais , Desmame do Respirador , Humanos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Ultrassonografia , Estudos Prospectivos , Respiração Artificial , Diafragma/diagnóstico por imagem , Diafragma/fisiologia
7.
Zhongguo Wei Zhong Bing Ji Jiu Yi Xue ; 24(9): 526-9, 2012 Sep.
Artigo em Chinês | MEDLINE | ID: mdl-22938659

RESUMO

OBJECTIVE: To investigate the effect of postoperative restrictive fluid management by ensuring adequate tissue perfusion on the recovery of gastrointestinal function after elective colonic resection. METHODS: Thirty patients suffered with elective colonic resection, after 6 hours of anesthesia recovery, were randomly divided into restrictive fluid management group (restrictive group, n=15) and traditional fluid management group (control group, n=15). From the surgery day to the 4th postoperative day, patients in restrictive group and control group received the total fluids of 25-35 ml×kg(-1)×d(-1) or 40-50 ml×kg(-1)×d(-1) respectively. Fluid balance, tissue perfusion, gastrointestinal function recovery time and the imbalance of fluid and electrolyte were recorded. RESULTS: The total fluid input and net fluid balance in restrictive group were significantly fewer than those in control group (total fluid input: 1782.56±258.38 ml/d vs. 2707.50±294.64 ml/d, net fluid balance: 316.67±202.86 ml/d vs. 623.33±244.38 ml/d, both P<0.05), and central venous pressure (CVP) was significantly lower than that in control group (4.03±1.81 mm Hg vs. 6.47±3.09 mm Hg, P<0.05). There were no differences in heart rate (HR) and mean arterial pressure (MAP) between two groups (HR: 85.03±13.49 bpm vs. 81.44±12.49 bpm, MAP: 80.65±11.39 mm Hg vs. 82.38±8.28 mm Hg, both P>0.05). The lactate clearance rate of the first postoperative 24 hours in restrictive group was higher than that in control group [35 (17, 53)% vs. 17 (-6, 33)%, P<0.05]. The times of bowel sounds recovery, the first flatus and stool passed in restrictive group were shorter than those in control group (bowel sounds: 37.43±24.97 hours vs. 46.36±19.34 hours, flatus: 53.63±12.78 hours vs. 75.43±20.07 hours, stool: 78.73±46.48 hours vs. 93.40±41.08 hours, all P<0.05). Vomiting was reduced in the restrictive group compared with control group (2 vs. 7, P<0.05). There were no differences in the occurrences of electrolyte imbalance (5 vs. 3), fluid insufficient (2 vs. 0) and fluid overload (0 vs. 1) between the two groups. CONCLUSION: The postoperative restrictive fluid management by ensuring tissue perfusion can shorten the gastrointestinal function recovery time after elective colonic resection, and may not increase the incidence of water and electrolyte disorders.


Assuntos
Colectomia/reabilitação , Hidratação , Adulto , Idoso , Feminino , Trato Gastrointestinal , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Estudos Prospectivos , Recuperação de Função Fisiológica , Equilíbrio Hidroeletrolítico
8.
J Intensive Med ; 2(2): 92-102, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36785779

RESUMO

Background: The coronavirus disease 2019 (COVID-19) is an ongoing pandemic. Invasive mechanical ventilation (IMV) is essential for the management of COVID-19 with acute respiratory distress syndrome (ARDS). We aimed to assess the impact of compliance with a respiratory decision support system on the outcomes of patients with COVID-19-associated ARDS who required IMV. Methods: In this retrospective, single-center, case series study, patients with COVID-19-associated ARDS who required IMV at Zhongnan Hospital of Wuhan University, China, from January 8th, 2020, to March 24th, 2020, with the final follow-up date of April 20th, 2020, were included. Demographic, clinical, laboratory, imaging, and management information were collected and analyzed. Compliance with the respiratory support decision system was documented, and its relationship with 28-day mortality was evaluated. Results: The study included 46 COVID-19-associated ARDS patients who required IMV. The median age of the 46 patients was 68.5 years, and 31 were men. The partial pressure of arterial oxygen (PaO2)/fraction of inspired oxygen (FiO2) ratio at intensive care unit (ICU) admission was 104 mmHg. The median total length of IMV was 12.0 (interquartile range [IQR]: 6.0-27.3) days, and the median respiratory support decision score was 11.0 (IQR: 7.8-16.0). To 28 days after ICU admission, 18 (39.1%) patients died. Survivors had a significantly higher respiratory support decision score than non-survivors (15.0 [10.3-17.0] vs. 8.5 (6.0-10.3), P = 0.001). Using receiver operating characteristic (ROC) curve to assess the discrimination of respiratory support decision score to 28-day mortality, the area under the curve (AUC) was 0.796 (95% confidence interval [CI]: 0.657-0.934, P = 0.001) and the cut-off was 11.5 (sensitivity = 0.679, specificity = 0.889). Patients with a higher score (>11.5) were more likely to survive at 28 days after ICU admission (log-rank test, P < 0.001). Conclusions: For severe COVID-19-associated ARDS with IMV, following the respiratory support decision and assessing completion would improve the progress of ventilation. With a decision score of >11.5, the mortality at 28 days after ICU admission showed an obvious decrease.

9.
J Crit Care ; 65: 192-199, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34225083

RESUMO

PURPOSE: We evaluated Galectin-3 (Gal-3) as a potential early biomarker of acute kidney disease (AKI), and the effect of Gal-3 inhibition by modified citrus pectin (P-MCP) on renal ischemia/reperfusion (I/R) induced AKI. METHODS: Among fifty-two post-cardiac surgery patients, serum and urine Gal-3 levels were examined on intensive care unit (ICU) admission. In a rat renal I/R injury model, Gal-3 levels, renal function, and histopathology were evaluated in rats pretreated with P-MCP for one week (n = 16) compared to controls (n = 16). RESULTS: Among post-cardiac surgery patients, median serum and urine Gal-3 levels on ICU admission were higher in patients who developed AKI than those who did not (AKI vs non-AKI serum: 18.37 vs. 8.08 ng/ml, p < 0.001; AKI vs non-AKI urine:13.27 vs. 6.27 ng/ml, p < 0.001). Serum and urine Gal-3 levels were reliable biomarkers for detecting AKI (AUC: 0.88 and 0.87). In the rat renal I/R injury model, I/R caused an increase of Gal-3 at 0.5 h after reperfusion (p < 0.05). Gal-3 inhibition by P-MCP significantly decreased Gal-3 release and expression (p < 0.05), reduced interleukin (IL-6) release (p < 0.05), decreased renal dysfunction, and reduced renal tubular injury. CONCLUSIONS: Gal-3 is a potential early biomarker in the diagnosis of AKI. Inhibition of Gal-3 may provide therapeutic utility in the treatment of I/R-induced AKI.


Assuntos
Injúria Renal Aguda , Galectina 3 , Injúria Renal Aguda/diagnóstico , Animais , Biomarcadores , Proteínas Sanguíneas , Galectinas , Humanos , Isquemia , Ratos , Reperfusão
10.
Shock ; 56(2): 200-205, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33234837

RESUMO

PURPOSE: We used lung ultrasonography to identify features of COVID-19 pneumonia and to evaluate the prognostic value. PATIENTS AND METHODS: We performed lung ultrasonography on 48 COVID-19 patients in an intensive care unit (ICU) (Wuhan, China) using a 12-zone method. The associations between lung ultrasonography score, PaO2/FiO2, APACHE II, SOFA, and PaCO2 with 28-day mortality were analyzed and the receiver operator characteristic curve was plotted. RESULTS: 25.9% areas in all scanning zones presented with B7 lines and 23.5% with B3 lines (B-pattern) on lung ultrasonography; 13% areas with confluent B lines (B-pattern), 24.9% in areas with consolidations, and 9.9% in areas with A lines. Pleural effusion was observed in 2.8% of areas. Lung ultrasonography score was negatively correlated with PaO2/FiO2 (n = 48, r = -0.498, P < 0.05) and positively correlated with APACHE II (n = 48, r = 0.435, P < 0.05). Lung ultrasonography score was independently associated with 28-day mortality. The areas under receiver operator characteristic curves of lung ultrasonography score were 0.735 (95% CI: 0.586-0.844). The sensitivity, specificity, and cutoff values were 0.833, 0.722, and 22.5, respectively. CONCLUSIONS: Lung ultrasonography could be used to assess the severity of COVID-19 pneumonia, and it could also reveal the pathological signs of the disease. The lung ultrasonography score on ICU admission was independently related to the ICU 28-day mortality.


Assuntos
COVID-19/diagnóstico , Pulmão/diagnóstico por imagem , Ultrassonografia/métodos , Idoso , COVID-19/epidemiologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Pandemias , Prognóstico , Estudos Prospectivos , Curva ROC , SARS-CoV-2
11.
Radiol Cardiothorac Imaging ; 2(2): e200126, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33778568

RESUMO

PURPOSE: To compare radiologic characteristics of coronavirus disease 2019 (COVID-19) pneumonia at thin-section CT on admission between patients with mild and severe disease. MATERIALS AND METHODS: Seventy patients with COVID-19 pneumonia who were admitted to Zhongnan Hospital of Wuhan University between January 20, 2020 and January 27, 2020 were enrolled. On the basis of the World Health Organization guidelines, 50 patients were categorized with the mild form and 20 with the severe form based on clinical conditions. Imaging features, clinical, and laboratory data were reviewed and compared. RESULTS: Patients with the severe form (median age, 65 years; interquartile range [IQR]: 54.75-75.00 years) were older than those with the mild form of disease (median age, 42.5 years; IQR: 32.75-58.50 years) (P < .001). Patients with the severe form of disease had more lung segments involved (median number of segments: 17.5 vs 7.5, P ≤ .001) and also larger opacities (median number of segments with opacities measuring 3 cm to less than 50% of the lung segment: 5.5 vs 2.0, P = .006; ≥ 50% of lung segment: 7.5 vs 0.0, P < .001). They also had more interlobular septal thickening (75% vs 28%, P < .001), higher prevalence of air bronchograms (70% vs 32%, P = .004), and pleural effusions (40% vs 14%, P = .017). CONCLUSION: Ground-glass opacities with or without consolidation in a peripheral and basilar predominant distribution were the most common findings in COVID-19 pneumonia. Patients with the severe form of the disease had more extensive opacification of the lung parenchyma than did patients with mild disease. Interlobular septal thickening, air bronchograms, and pleural effusions were also more prevalent in severe COVID-19.© RSNA, 2020.

12.
Orthop Surg ; 5(2): 112-7, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23658046

RESUMO

OBJECTIVE: To retrospectively compare the functional performances of rotating platform and fixed-bearing total knee arthroplasties with or without patellar resurfacing. METHODS: One hundred and ninety-seven patients (205 knees) of mean age 66.4 years were randomly assigned to receive different prostheses. One hundred ninety-five patients, including 97 fixed-bearing prostheses with 37 patellae resurfaced and 106 rotating platform prostheses with 76 patellae resurfaced, were followed up for a mean duration of 32 months. RESULTS: Outcomes in the rotating platform with patellar resurfacing and fixed-bearing with patellar resurfacing groups did not differ significantly according to Hospital for Special Surgery (HSS) scores and flexion and extension angles. For total knee arthroplasties without patellar resurfacing, there were no significant differences in HSS score and flexion angle between the rotating platform and fixed-bearing subgroups. Although the extension angle of rotating platform prostheses was slightly better than that of the fixed-bearing in the patellar non-resurfacing group, this difference was not clinically significant. CONCLUSIONS: Rotating platform and fixed-bearing prostheses have similar overall postoperative outcomes with regard to postoperative HSS scores and extension and flexion angles. Rotating platform prostheses are not superior to fixed bearing prostheses.


Assuntos
Artroplastia do Joelho/métodos , Prótese do Joelho , Patela/cirurgia , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/instrumentação , Feminino , Seguimentos , Humanos , Articulação do Joelho/fisiopatologia , Pessoa de Meia-Idade , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/cirurgia , Desenho de Prótese , Radiografia , Amplitude de Movimento Articular , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA