RESUMO
A 53-year-old patient with a history of heart transplant is referred for atrial tachycardia ablation. Two dissociated concomitant rhythms are observed: a focal atrial tachycardia in the donor atrium and atrial fibrillation in the remaining recipient atrium.
RESUMO
AIMS: Neither the long-term development of ablation lesions nor the capability of late gadolinium enhancement (LGE)-MRI to detect ablation-induced fibrosis at late stages of scar formation have been defined. We sought to assess the development of atrial ablation lesions over time using LGE-MRI and invasive electroanatomical mapping (EAM). METHODS AND RESULTS: Ablation lesions and total atrial fibrosis were assessed in serial LGE-MRI scans 3 months and >12 months post pulmonary vein (PV) isolation. High-density EAM performed in subsequent repeat ablation procedures served as a reference. Serial LGE-MRI of 22 patients were analyzed retrospectively. The PV encircling ablation lines displayed an average LGE, indicative of ablation-induced fibrosis, of 91.7% ± 7.0% of the circumference at 3 months, but only 62.8% ± 25.0% at a median of 28 months post ablation (p < 0.0001). EAM performed in 18 patients undergoing a subsequent repeat procedure revealed that the consistent decrease in LGE over time was owed to a reduced detectability of ablation-induced fibrosis by LGE-MRI at time-points > 12 months post ablation. Accordingly, the agreement with EAM regarding detection of ablation-induced fibrosis and functional gaps was good for the LGE-MRI at 3 months (κ .74; p < .0001), but only weak for the LGE-MRI at 28 months post-ablation (κ .29; p < .0001). CONCLUSION: While non-invasive lesion assessment with LGE-MRI 3 months post ablation provides accurate guidance for future redo-procedures, detectability of atrial ablation lesions appears to decrease over time. Thus, it should be considered to perform LGE-MRI 3 months post-ablation rather than at later time-points > 12 months post ablation, like for example, prior to a planned redo-ablation procedure.
Assuntos
Fibrilação Atrial/cirurgia , Cicatriz/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Técnicas de Imagem de Sincronização Cardíaca , Cicatriz/etiologia , Meios de Contraste , Técnicas Eletrofisiológicas Cardíacas , Feminino , Fibrose/diagnóstico por imagem , Fibrose/etiologia , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos , Complicações Pós-Operatórias/etiologia , Veias Pulmonares/cirurgia , Recidiva , Sistema de Registros , Estudos Retrospectivos , EspanhaRESUMO
AIMS: Left atrial (LA) fibrosis is present in patients with atrial fibrillation (AF) and can be visualized by magnetic resonance imaging with late gadolinium enhancement (LGE-MRI). Previous studies have shown that LA fibrosis is not randomly distributed, being more frequent in the area adjacent to the descending aorta (DAo). The objective of this study is to analyse the relationship between fibrosis in the atrial area adjacent to the DAo and the distance to it, as well as the prognostic implications of this fibrosis. METHODS AND RESULTS: Magnetic resonance imaging with late gadolinium enhancement was obtained in 108 patients before AF ablation to analyse the extent of LA fibrosis and the distance DAo-to-LA. A high-density electroanatomic map was performed in a subgroup of 16 patients to exclude the possibility of an MRI artifact. Recurrences after ablation were analysed at 1 year of follow-up. The extent of atrial fibrosis in the area adjacent to the DAo was inversely correlated with the distance DAo-to-LA (r = -0.34, P < 0.001). This area had the greatest intensity of LGE [image intensity ratio (IIR) 1.14 ± 0.15 vs. 0.99 ± 0.16; P < 0.001] and also the lowest voltage (1.07 ± 0.86 vs. 1.54 ± 1.07 mV; P < 0.001) and conduction velocity (0.65 ± 0.06 vs. 0.96 ± 0.57 mm/ms; P < 0.001). The extent of this regional fibrosis predicted recurrence after AF ablation [hazard ratio (HR) 1.02, 95% CI 1.01-1.03; P = 0.01], however total fibrosis did not (HR = 1.01, 95% CI 0.97-1.06, P = 0.54). CONCLUSIONS: Atrial fibrosis was predominantly located in the area adjacent to the DAo, and increased with the proximity between the two structures. Furthermore, this regional fibrosis better predicted recurrence after AF ablation than total atrial fibrosis.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/patologia , Meios de Contraste , Fibrose , Gadolínio , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/patologia , Átrios do Coração/cirurgia , Humanos , Imageamento por Ressonância Magnética , PrognósticoRESUMO
AIMS: Myocardial fibrosis is a hallmark of atrial fibrillation (AF) and its characterization could be used to guide ablation procedures. Late gadolinium enhanced-magnetic resonance imaging (LGE-MRI) detects areas of atrial fibrosis. However, its accuracy remains controversial. We aimed to analyse the accuracy of LGE-MRI to identify left atrial (LA) arrhythmogenic substrate by analysing voltage and conduction velocity at the areas of LGE. METHODS AND RESULTS: Late gadolinium enhanced-magnetic resonance imaging was performed before ablation in 16 patients. Atrial wall intensity was normalized to blood pool and classified as healthy, interstitial fibrosis, and dense scar tissue depending of the resulting image intensity ratio. Bipolar voltage and local conduction velocity were measured in LA with high-density electroanatomic maps recorded in sinus rhythm and subsequently projected into the LGE-MRI. A semi-automatic, point-by-point correlation was made between LGE-MRI and electroanatomical mapping. Mean bipolar voltage and local velocity progressively decreased from healthy to interstitial fibrosis to scar. There was a significant negative correlation between LGE with voltage (r = -0.39, P < 0.001) and conduction velocity (r = -0.25, P < 0.001). In patients showing dilated atria (LA diameter ≥45 mm) the conduction velocity predictive capacity of LGE-MRI was weaker (r = -0.40 ± 0.09 vs. -0.20 ± 0.13, P = 0.02). CONCLUSIONS: Areas with higher LGE show lower voltage and slower conduction in sinus rhythm. The enhancement intensity correlates with bipolar voltage and conduction velocity in a point-by-point analysis. The performance of LGE-MRI in assessing local velocity might be reduced in patients with dilated atria (LA diameter ≥45).
Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/cirurgia , Meios de Contraste , Fibrose , Gadolínio , Átrios do Coração/cirurgia , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância MagnéticaRESUMO
AIMS: Our aim was to analyse whether using delayed enhancement cardiac magnetic resonance imaging (DE-CMR) to localize veno-atrial gaps in atrial fibrillation (AF) redo ablation procedures improves outcomes during follow-up. METHODS AND RESULTS: We conducted a case-control study with 35 consecutive patients undergoing a DE-CMR-guided Repeat-pulmonary vein isolation (Re-PVI) procedure. Those with more extensive ablations (e.g. roof lines, box) were excluded. Patients were matched for age, sex, AF pattern, and left atrial dimension with 35 patients who had undergone a conventional Re-PVI procedure guided with a three dimensional (3D)-navigation system. Procedural characteristics were recorded, and patients were followed for 24 months in a specialized outpatient clinic. The primary endpoint was freedom from recurrent AF, atrial tachycardia, or flutter. The duration of CMR-guided procedures was shorter compared to the conventional group (161 ± 52 vs. 195 ± 72 min, respectively, P = 0.049), with no significant differences in fluoroscopy or total radiofrequency time. At the 2-year follow-up, more patients in the DE-CMR-guided group remained free from recurrences compared with the conventional group (70% vs. 39%, respectively, P = 0.007). In univariate Cox-regression analyses, AF pattern [persistent AF, hazard ratio (HR) 2.66 (1.27-5.46), P = 0.006] and the use of DE-CMR [HR 0.36 (0.17-0.79), P = 0.009] predicted recurrences during follow-up; both factors remained independent predictors in multivariate analyses. CONCLUSION: The substrate characterization provided by DE-CMR facilitates the identification of anatomical veno-atrial gaps and associates with shorter procedures and better clinical outcomes in repeated AF ablation procedures.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Estudos de Casos e Controles , Ablação por Cateter/efeitos adversos , Humanos , Espectroscopia de Ressonância Magnética , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Resultado do TratamentoRESUMO
INTRODUCTION AND OBJECTIVES: Late gadolinium-enhanced cardiac magnetic resonance (LGE-CMR) allows noninvasive detection of left atrial fibrosis in patients with atrial fibrillation (AF). However, whether the same methodology can be used in the right atrium (RA) remains unknown. Our aim was to define a standardized threshold to characterize RA fibrosis in LGE-CMR. METHODS: A 3 Tesla LGE-CMR was performed in 53 individuals; the RA was segmented, and the image intensity ratio (IIR) calculated for the RA wall using 1 557 767 IIR pixels (40 994±10 693 per patient). The upper limit of normality of the IIR (mean IIR+2 standard deviations) was estimated in healthy volunteers (n=9), and patients who had undergone previous typical atrial flutter ablation (n=9) were used to establish the dense scar threshold. Paroxysmal and persistent AF patients (n=10 each) were used for validation. IIR values were correlated with a high-density bipolar voltage map in 15 patients undergoing AF ablation. RESULTS: The upper normality limit (total fibrosis threshold) in healthy volunteers was set at an IIR = 1.21. In the postablation group, 60% of the maximum IIR pixel (dense fibrosis threshold) was calculated as IIR = 1.29. Endocardial bipolar voltage showed a weak but significant correlation with IIR. The overall accuracy between the electroanatomical map and LGE-CMR to characterize fibrosis was 56%. CONCLUSIONS: An IIR > 1.21 was determined to be the threshold for the detection of right atrial fibrosis, while an IIR > 1.29 differentiates interstitial fibrosis from dense scar. Despite differences between the left and right atria, fibrosis could be assessed with LGE-CMR using similar thresholds in both chambers.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Cicatriz/patologia , Cicatriz/cirurgia , Meios de Contraste , Átrios do Coração/patologia , Imageamento por Ressonância Magnética/métodos , Fibrilação Atrial/cirurgia , Fibrose , Ablação por Cateter/métodos , Gadolínio , Espectroscopia de Ressonância MagnéticaRESUMO
Background: Substrate-based ablation has become a successful technique for ventricular tachycardia (VT) ablation. High-density (HD) mapping catheters provide high-resolution electroanatomical maps and better discrimination of local abnormal electrograms. The HD Grid Mapping Catheter is an HD catheter with the ability to map orthogonal signals on top of conventional bipolar signals, which could provide better discrimination of the arrhythmic substrate. On the other hand, conventional mapping techniques, such as activation mapping, when possible, help to identify the isthmus of the tachycardia. Aim: The purpose of this study was to compare clinical outcomes after using two different VT ablation strategies: one based on extensive mapping with the HD Grid Mapping Catheter, including VT isthmus analysis, and the other based on pure substrate ablation. Methods: Forty consecutive patients undergoing VT ablation with extensive HD mapping method in the hospital clinic (November 2018-November 2019) were included. Clinical outcomes were compared with a historical cohort of 26 consecutive patients who underwent ablation using a scar dechanneling technique before 2018. Results: The density of mapping points was higher in the extensive mapping group (2370.24 ± 920.78 vs. 576.45 ± 294.46; p < 0.001). After 1 year of follow-up, VT recurred in 18.4% of patients in the extensive mapping group vs. 34.6% of patients in the historical control group (p = 0.14), with a significantly greater reduction of VT burden: VT episodes (81.7 ± 7.79 vs. 43.4 ± 19.9%, p < 0.05), antitachycardia pacing (99.45 ± 2.29 vs. 33.9 ± 102.5%, p < 0.001), and implantable cardioverter defibrillator (ICD) shocks (99 ± 4.5 vs. 64.7 ± 59.9%, p = 0.02). Conclusion: The use of a method based on extensive mapping with the HD Grid Mapping Catheter and VT isthmus analysis allows better discrimination of the arrhythmic substrate and could be associated with a greater decrease in VT burden.
RESUMO
Background Left atrial structural remodeling contributes to the arrhythmogenic substrate of atrial fibrillation (AF), but the role of the right atrium (RA) remains unknown. Our aims were to comprehensively characterize right atrial structural remodeling in AF and identify right atrial parameters predicting recurrences after ablation. Methods and Results A 3.0 T late gadolinium enhanced-cardiac magnetic resonance was obtained in 109 individuals (9 healthy volunteers, 100 patients with AF undergoing ablation). Right and left atrial volume, surface, and sphericity were quantified. Right atrial global and regional fibrosis burden was assessed with validated thresholds. Patients with AF were systematically followed after ablation for recurrences. Progressive right atrial dilation and an increase in sphericity were observed from healthy volunteers to patients with paroxysmal and persistent AF; fibrosis was similar among the groups. The correlation between parameters recapitulating right atrial remodeling was mild. Subsequently, remodeling in both atria was compared. The RA was larger than the left atrium (LA) in all groups. Fibrosis burden was higher in the LA than in the RA of patients with AF, whereas sphericity was higher in the LA of patients with persistent AF only. Fibrosis, volume, and surface of the RA and LA, but not sphericity, were strongly correlated. Tricuspid regurgitation predicted right atrial volume and shape, whereas diabetes was associated with right atrial fibrosis burden; sex and persistent AF also predicted right atrial volume. Fibrosis in the RA was mostly located in the inferior vena cava-RA junction. Only right atrial sphericity is significantly associated with AF recurrences after ablation (hazard ratio, 1.12 [95% CI, 1.01-1.25]). Conclusions AF progression associates with right atrial remodeling in parallel with the LA. Right atrial sphericity yields prognostic significance after ablation.
Assuntos
Fibrilação Atrial , Remodelamento Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/patologia , Ablação por Cateter/métodos , Gadolínio , Átrios do Coração , Fibrose , Espectroscopia de Ressonância MagnéticaRESUMO
INTRODUCTION: Data regarding the efficacy of catheter ablation in patients with atrial fibrillation (AF) and patients' previous history of pulmonary lobectomy/pneumonectomy are scanty. We sought to evaluate the efficacy and long-term follow-up of catheter ablation in this highly selected group of patients. MATERIAL AND METHODS: Twenty consecutive patients (8 females, 40%; median age 65.2 years old) with a history of pneumonectomy/lobectomy and paroxysmal or persistent AF, treated by means of pulmonary vein isolation (PVI) at ten participating centers were included. Procedural success, intra-procedural complications, and AF recurrences were considered. RESULTS: Fifteen patients had a previous lobectomy and five patients had a complete pneumonectomy. A large proportion (65%) of PV stumps were electrically active and represented a source of firing in 20% of cases. PVI was performed by radiofrequency ablation in 13 patients (65%) and by cryoablation in the remaining 7 cases. Over a median follow up of 29.7 months, a total of 7 (33%) AF recurrences were recorded with neither a difference between patients treated with cryoablation or radiofrequency ablation or between the two genders. CONCLUSIONS: Catheter ablation by radiofrequency ablation or cryoablation in patients with pulmonary stumps is feasible and safe. Long-term outcomes are favorable, and a similar efficacy of catheter ablation has been noticed in both males and females.
RESUMO
BACKGROUND: Scar characteristics analyzed by late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) are related with ventricular arrhythmias. Current guidelines are based only on the left ventricular ejection fraction to recommend an implantable cardioverter-defibrillator (ICD) in primary prevention. OBJECTIVES: Our study aims to analyze the role of imaging to stratify arrhythmogenic risk in patients with ICD for primary prevention. METHODS: From 2006 to 2017, we included 200 patients with LGE-CMR before ICD implantation for primary prevention. The scar, border zone, core, and conducting channels (CCs) were automatically measured by a dedicated software. RESULTS: The mean age was 60.9 ± 10.9 years; 81.5% (163) were men; 52% (104) had ischemic cardiomyopathy. The mean left ventricular ejection fraction was 29% ± 10.1%. After a follow-up of 4.6 ± 2 years, 46 patients (22%) reached the primary end point (appropriate ICD therapy). Scar mass (36.2 ± 19 g vs 21.7 ± 10 g; P < .001), border zone mass (26.4 ± 12.5 g vs 16.0 ± 9.5 g; P < .001), core mass (9.9 ± 8.6 g vs 5.5 ± 5.7 g; P < .001), and CC mass (3.0 ± 2.6 g vs 1.6 ± 2.3 g; P < .001) were associated with appropriate therapies. Scar mass > 10 g (25.31% vs 5.26%; hazard ratio 4.74; P = .034) and the presence of CCs (34.75% vs 8.93%; hazard ratio 4.07; P = .003) were also strongly associated with the primary end point. However, patients without channels and with scar mass < 10 g had a very low rate of appropriate therapies (2.8%). CONCLUSION: Scar characteristics analyzed by LGE-CMR are strong predictors of appropriate therapies in patients with ICD in primary prevention. The absence of channels and scar mass < 10 g can identify patients at a very low risk of ventricular arrhythmias in this population.
Assuntos
Cicatriz/patologia , Desfibriladores Implantáveis , Imagem Cinética por Ressonância Magnética/métodos , Isquemia Miocárdica/diagnóstico , Miocárdio/patologia , Prevenção Primária/métodos , Taquicardia Ventricular/prevenção & controle , Cicatriz/complicações , Meios de Contraste/farmacologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/complicações , Volume Sistólico/fisiologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Fatores de Tempo , Função Ventricular EsquerdaRESUMO
Two-dimensional representation of 3D anatomical structures is a simple and intuitive way for analysing patient information across populations and image modalities. While cardiac ventricles, especially the left ventricle, have an established standard representation (bull's eye plot), the 2D depiction of the left atrium (LA) remains challenging due to its sub-structural complexity including the pulmonary veins (PV) and the left atrial appendage (LAA). Quasi-conformal flattening techniques, successfully applied to cardiac ventricles, require additional constraints in the case of the LA to place the PV and LAA in the same geometrical 2D location for different cases. Some registration-based methods have been proposed but surface registration is time-consuming and prone to errors when the geometries are very different. We propose a novel atrial flattening methodology where a 2D standardised map of the LA is obtained quickly and without errors related to registration. The LA is divided into five regions which are then mapped to their analogue two-dimensional regions. 67 human left atria from magnetic resonance images (MRI) were studied to derive a population-based template representing the averaged relative locations of the PVs and LAA. The clinical application of our methodology is illustrated on different use cases including the integration of MRI and electroanatomical data.
Assuntos
Átrios do Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Humanos , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Veias Pulmonares/diagnóstico por imagemRESUMO
BACKGROUND: Myocardial fibrosis is key for atrial fibrillation maintenance. We aimed to test the efficacy of ablating cardiac magnetic resonance (CMR)-detected atrial fibrosis plus pulmonary vein isolation (PVI). METHODS: This was an open-label, parallel-group, randomized, controlled trial. Patients with symptomatic drug-refractory atrial fibrillation (paroxysmal and persistent) undergoing first or repeat ablation were randomized in a 1:1 basis to receive PVI plus CMR-guided fibrosis ablation (CMR group) or PVI alone (PVI-alone group). The primary end point was the rate of recurrence (>30 seconds) at 12 months of follow-up using a 12-lead ECG and Holter monitoring at 3, 6, and 12 months. The analysis was conducted by intention-to-treat. RESULTS: In total, 155 patients (71% male, age 59±10, CHA2DS2-VASc 1.3±1.1, 54% paroxysmal atrial fibrillation) were allocated to the PVI-alone group (N=76) or CMR group (N=79). First ablation was performed in 80% and 71% of patients in the PVI-alone and CMR groups, respectively. The mean atrial fibrosis burden was 12% (only ≈50% of patients had fibrosis outside the pulmonary vein area). One hundred percent and 99% of patients received the assigned intervention in the PVI-alone and CMR group, respectively. The primary outcome was achieved in 21 patients (27.6%) in the PVI-alone group and 22 patients (27.8%) in the CMR group (odds ratio: 1.01 [95% CI, 0.50-2.04]; P=0.976). There were no differences in the rate of adverse events (3 in the CMR group and 2 in the PVI-alone group; P=0.68). CONCLUSIONS: A pragmatic ablation approach targeting CMR-detected atrial fibrosis plus PVI was not more effective than PVI alone in an unselected population undergoing atrial fibrillation ablation with low fibrosis burden. Registration: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02698631.
Assuntos
Fibrilação Atrial/cirurgia , Remodelamento Atrial , Ablação por Cateter , Átrios do Coração/cirurgia , Imageamento por Ressonância Magnética , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Eletrocardiografia Ambulatorial , Feminino , Fibrose , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Veias Pulmonares/fisiopatologia , Recidiva , Espanha , Fatores de Tempo , Resultado do TratamentoRESUMO
BACKGROUND: There is limited knowledge about the impact of anatomic gaps as assessed by delayed gadolinium enhancement cardiac magnetic resonance on atrial fibrillation (AF) recurrence after first pulmonary vein (PV) isolation. METHODS: Consecutive patients underwent delayed gadolinium enhancement cardiac magnetic resonance 3 months after radiofrequency circumferential PV isolation. Delayed gadolinium enhancement cardiac magnetic resonance images were assessed from 360 PV resulting in 2880 segments in the 2×8-segment model from 94 patients (52±11 years, 62% paroxysmal AF). Left atria were segmented using dedicated software. Anatomic gap was defined as discontinuation of the ablation line by ≥3 mm. Relative gap length was calculated as absolute gap length divided by the total length of the ablation line. AF recurrence was assessed after a mean follow-up duration of 15±10 months Results: Mean number of anatomic gaps was 5.4 per patient. Recurrence within the first year of ablation was observed in 21 patients with paroxysmal AF (36%) and 19 patients with persistent AF (53%). In the univariate analysis, CHA2DS2-VASc score, AF type, and relative gap length were predictive of recurrence. In the multivariate analysis, only relative gap length was significantly associated with recurrence (hazard ratio, 1.16 [1.02-1.31] per each 10% of gap). CONCLUSIONS: The total relative gap length but not the number of anatomic gaps in the PV ablation line as assessed by delayed gadolinium enhancement cardiac magnetic resonance was associated with AF recurrence 1 year after first PV isolation. An increase of 10% relative gap length increased the likelihood of AF recurrence by 16%.
Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Gadolínio , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Veias Pulmonares/cirurgia , Adulto , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/mortalidade , Ablação por Cateter/mortalidade , Estudos de Coortes , Meios de Contraste , Feminino , Humanos , Aumento da Imagem/métodos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Modelos de Riscos Proporcionais , Recidiva , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Espanha , Estatísticas não Paramétricas , Análise de SobrevidaRESUMO
BACKGROUND: Out-of-Hospital Cardiac Arrest (OHCA) and mild therapeutic hypothermia (MTH) have been linked to increased risk of Stent Thrombosis (ST) in comatose survivors who undergo percutaneous coronary intervention (PCI). In this sense, there is no formal recommendation about which antiplatelet regimen should be used in patients with acute coronary syndromes (ACS) after OHCA. AIMS: To compare the incidence of probable/definite ST and bleeding events between ticagrelor and clopidogrel, in patients with ACS under MTH after an OHCA. METHODS AND RESULTS: From January 2010 to August 2016, 144 patients underwent MTH after an OHCA. Overall, 114 had an ACS (79%) and 98 (67,3%) were treated with primary PCI and stent implantation. Among them, 61 (62,2%) were treated with clopidogrel, and 32 (32,6%) with ticagrelor. During hospitalization, the incidence of probable or definite ST was significantly higher in patients receiving clopidogrel compared to ticagrelor (11,4% vs. 0%; p: 0.04), and no significant differences in any (28,6% vs. 25%; p: 0.645) or major bleeding (BARC 3 or 5) (11,4% vs. 12,5%; p: 0.685) were found. Hospital mortality did not differ between groups (26,2% vs. 25%; p: 0.862). CONCLUSIONS: In this study, as compared to clopidogrel, ticagrelor was associated with a lower rate of ST, without differences in haemorrhagic events in patients with OHCA for an ACS under MTH. Similarly to other settings, ticagrelor might be a valid alternative to clopidogrel in these patients.
Assuntos
Adenosina/análogos & derivados , Trombose Coronária/tratamento farmacológico , Parada Cardíaca Extra-Hospitalar/terapia , Inibidores da Agregação Plaquetária/uso terapêutico , Stents/efeitos adversos , Ticlopidina/análogos & derivados , Adenosina/uso terapêutico , Idoso , Clopidogrel , Trombose Coronária/etiologia , Humanos , Hipotermia Induzida/efeitos adversos , Masculino , Pessoa de Meia-Idade , Parada Cardíaca Extra-Hospitalar/complicações , Intervenção Coronária Percutânea/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Ticagrelor , Ticlopidina/uso terapêuticoAssuntos
COVID-19 , Produtos de Degradação da Fibrina e do Fibrinogênio/análise , Hematoma , Heparina , Pulmão , Embolia Pulmonar , Anticoagulantes/administração & dosagem , Anticoagulantes/efeitos adversos , COVID-19/sangue , COVID-19/diagnóstico , COVID-19/fisiopatologia , COVID-19/terapia , Angiografia por Tomografia Computadorizada/métodos , Hematoma/complicações , Hematoma/diagnóstico por imagem , Hematoma/terapia , Heparina/administração & dosagem , Heparina/efeitos adversos , Humanos , Hipóxia/etiologia , Hipóxia/terapia , Pulmão/diagnóstico por imagem , Pulmão/patologia , Masculino , Pessoa de Meia-Idade , Administração dos Cuidados ao Paciente/métodos , Seleção de Pacientes , Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico por imagem , Embolia Pulmonar/etiologia , Embolia Pulmonar/terapia , Risco Ajustado/métodos , SARS-CoV-2 , Resultado do TratamentoRESUMO
BACKGROUND: Mild therapeutic hypothermia (MTH) is associated with an increased risk of both thrombotic and bleeding events. Although little is known about the use of Glycoprotein IIb-IIIa inhibitors (GPi) in this setting, the early action and the intravenous administration of these agents in patients who cannot swallow might potentially translate into clinical benefits in patients with acute coronary syndromes (ACS). AIMS: To assess the incidence of bleeding/thrombotic events in patients with ACS under MTH after an Out-of-hospital cardiac arrest (OHCA) who received GPi or not. METHODS AND RESULTS: From January 2010 to September 2015, 110 patients were treated with MTH after an OHCA. Among them, 88 (80%) had an ACS and 71 patients (80.6%) underwent percutaneous coronary intervention (PCI). In 17 (24%) GPi were administered in the cath-lab. During hospitalization, 11.7% in the GPi and 9.25%in the non GPi group presented thrombotic events (stent thrombosis, deep vein thrombosis, pulmonary embolism) without significant differences between groups (p= 0.762). The incidence of any bleeding (64.7% vs. 14.8%; p<0.0001), and major bleeding (41.1% vs. 3.7; p<0.0001) was significantly higher in patients receiving GPi. Finally, in-hospital mortality did not differ between groups (24% vs. 35, 2%; p=0.385). CONCLUSIONS: In this study, the use of GPi in patients with ACS undergoing PCI under MTH was associated with an increased bleeding risk without reduction of thrombotic events. According to these results, the use of GPi should be carefully considered in this setting.