Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Clin Oncol (R Coll Radiol) ; 35(12): e676-e688, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37802722

RESUMO

AIMS: After primary radiotherapy, biochemical recurrence is defined according to the Phoenix criteria as a prostate-specific antigen (PSA) value >2 ng/ml relative to the nadir. Several studies have shown that prostate-specific membrane antigen (PSMA)-ligand positron emission tomography/computed tomography (PET/CT) can help in detecting recurrence in patients with low PSA values. This study aimed to assess the detection rate and patterns of PSMA-ligand PET/CT uptake in patients with suspected biochemical recurrence after primary radiotherapy and with PSA levels below the Phoenix threshold. MATERIALS AND METHODS: The meta-analysis was carried out in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement. Articles providing data on patients with suspected prostate cancer recurrence after primary radiotherapy with a PSA value below the Phoenix threshold and who underwent PSMA-ligand PET/CT were included. Quality assessment was carried out using the Quality Assessment of Diagnostic Accuracy Studies-2 tool (QUADAS-2). RESULTS: In total, five studies were included, recruiting 909 patients (202 with PSA ≤2 ng/ml). The PSMA-ligand detection rate in the patients with ≤2 ng/ml ranged from 66 to 83%. The most frequent source of PSMA-ligand PET/CT uptake was local recurrence, followed by lymph node metastasis and bone metastasis. PSMA-ligand PET/CT uptake due to local-only recurrence was more likely in patients with PSA ≤2 ng/ml compared with PSA > 2 ng/ml: risk ratio 0.72 (95% confidence interval 0.58-0.89), P = 0.003. No significant differences were observed in the detection of PSMA-ligand uptake in other areas. Limitations include a lack of biopsy confirmation, cohort reports with small sample sizes and a potentially high risk of bias. CONCLUSION: A significant detection of PSMA-ligand-avid disease was observed in patients with PSA levels below the Phoenix threshold. There was a higher likelihood of detecting local-only uptake when the PSA value was ≤2 ng/ml. The findings suggest that a critical review of the Phoenix criteria may be warranted in the era of PSMA-ligand PET/CT and highlight the need for further prospective trials.


Assuntos
Antígeno Prostático Específico , Neoplasias da Próstata , Masculino , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Próstata/patologia , Ligantes , Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/patologia , Estudos Retrospectivos
2.
Cancer Radiother ; 24(5): 444-452, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32620457

RESUMO

The aim of the present paper is to systematically review all available literature on preradiotherapy high uptake areas (hotspots) as a potential target for dose escalation in different tumour sites, and to understand the potential role and limitations of fluorodeoxyglucose (FDG)-positron-emission tomography (PET)/computed tomography (CT) in this context. An electronic database (Medline) search was conducted to identify articles reporting on a correlation between high tracer uptake on pretreatment PET and preferential sites of local recurrence after radiotherapy. Search was limited to English language. No date range limitation was applied. Among 45 studies initially identified, nine series matching with inclusion criteria have finally been retained from the literature after reviewing (5 retrospective and 4 prospective). Primary tumour locations were head-neck (n=2), lung (n=4), oesophageal (n=2) and rectal (n=1) areas. Overlaps between FDG hotspot on preradiotherapy PET/CT and site of local recurrence on post-treatment scan showed good to excellent agreement. Only studies on head-neck cancer reported moderate agreement probably explained by the lack of reproducibility of the patients positioning between pre- and post-treatment FDG-PET/CT; and by the rigid registration process of images limited by post-therapeutic changes that highly affect anatomical landmarks. FDG hotspot-guided radiotherapy may allow dose escalation in respecting a robust methodology (treatment position, co-registration method, four-dimensional PET).


Assuntos
Fluordesoxiglucose F18 , Recidiva Local de Neoplasia/diagnóstico por imagem , Neoplasias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Compostos Radiofarmacêuticos , Pontos de Referência Anatômicos/diagnóstico por imagem , Neoplasias Esofágicas/diagnóstico por imagem , Neoplasias Esofágicas/radioterapia , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Neoplasias/radioterapia , Posicionamento do Paciente , Estudos Prospectivos , Neoplasias Retais/diagnóstico por imagem , Neoplasias Retais/radioterapia , Estudos Retrospectivos
3.
J Dent Res ; 67(5): 836-40, 1988 May.
Artigo em Inglês | MEDLINE | ID: mdl-2835405

RESUMO

The objective of this investigation was to determine the influence of water exposure on the flexural strength of three experimental composite materials. The composites consisted of an experimental resin system which contained silane-treated filler particles of quartz, barium glass, and porous silica. The amorphous silica particles were spheres approximately 5 micron in diameter. In addition to the different composites, pure resin samples were investigated as a control group. The results of this investigation did not support the hypothesis that use of porous amorphous silica filler particles reduced the hydrolytic degradation effect of composites containing such silica particles. Instead, the results indicated that water may have a more detrimental effect on the strength of the matrix than on the filler-matrix interface. However, the relatively high frequency of fracture lines in the porous silica particles after storage in water indicate that water had a weakening effect on this type of filler.


Assuntos
Resinas Compostas , Água , Fenômenos Químicos , Físico-Química , Análise do Estresse Dentário , Elasticidade , Vidro , Metacrilatos , Polietilenoglicóis , Ácidos Polimetacrílicos , Quartzo , Dióxido de Silício , Resistência à Tração , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA