Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Biosens Bioelectron ; 249: 116014, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38219469

RESUMO

Pre-eclampsia is a serious multi-organ complication that severely threatens the safety of pregnant women and infants. To accurate and timely diagnose pre-eclampsia, point-of-care (POC) biosensing of the specific biomarkers is urgently required. However, one of the key biomarkers of pre-eclampsia, placental growth factor (PlGF), has a reduced level of expression in patients, which challenges the quantification capability and Limit-of-detection (LOD) of biosensors. Herein, we reported a microfiber Bragg grating biosensor for the quantification of PlGF in clinical serum samples. The Bragg grating was inscribed in a unilateral tapered fiber to generate the segmented Fabry-Perot spectrum for improving the capability of detection. Furthermore, a temperature-calibrated Bragg grating was added to enable dual parametric detection of PlGF and temperature simultaneously for removing the crosstalk. Finally, the biosensor was envisaged to be perfectly compatible with microfluidic chips, and thus dramatically reducing the sample consumption to as small as 10 µL. The proposed biosensor can respond to PlGF with concentrations ranging from 5 to 120 pg mL-1, attaining a LOD of 5 pg mL-1 of clinical relevance. More importantly, the biosensor achieved micro volume detection of clinical serum samples from patients, and the ROC curve with an AUC of 0.977 confirmed the viability of the device. Our study paves the way to a new idea for cost-effective and high-precision screening of patients with pre-eclampsia, and hence envisages a promising prospect for point-of-care (POC) diagnosis of patients with pre-eclampsia.


Assuntos
Técnicas Biossensoriais , Pré-Eclâmpsia , Gravidez , Feminino , Humanos , Pré-Eclâmpsia/diagnóstico , Fator de Crescimento Placentário , Sistemas Automatizados de Assistência Junto ao Leito , Biomarcadores
2.
Talanta ; 274: 125958, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38574534

RESUMO

Hydrovoltaic is an emerging technology that aims to harvest energy from water flow and evaporation, in which the plasmonic hydrogen ions are generated by the interaction between water and hydrovoltaic device. However, the volume of the water sample for the interaction is usually ultra-small due to the compact size of hydrovoltaic device, making the quantification and characterization of the hydrogen ions in such water sample an elusive goal. To address this issue, a miniature fiber-optic pH probe is proposed using a unilaterally tapered-microfiber Bragg grating. The microfiber Bragg grating has an intrinsic Bragg reflection signal with a narrow linewidth. The fiber probe is functionalized by coating the sodium alginate, which can respond to the variation of pH mediated by the alteration of the hydrophilicity. The rigidity and robustness of microfiber Bragg grating facilitates the encapsulation of the sensor into a sampling capillary, allowing for the detection of trace aqueous sample less than 2 µL. The pH sensitivity of the tapered-µFBG-based sensor is 62.8 p.m./pH (R2 = 0.995) with a limit resolution of 0.096 pH. The sensor performed a practical application in the monitoring and characterization of the hydrovoltaic microdevice, which can generate microcurrent as soaked in the water. This work demonstrates a promising technology in the fields of materials, energy, biology and medicine, in which the detection of the microsamples is inevitable.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA