J Vasc Surg ; 79(2): 420-435.e1, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37944771

RESUMO

OBJECTIVE: Despite the publication of various national/international guidelines, several questions concerning the management of patients with asymptomatic (AsxCS) and symptomatic (SxCS) carotid stenosis remain unanswered. The aim of this international, multi-specialty, expert-based Delphi Consensus document was to address these issues to help clinicians make decisions when guidelines are unclear. METHODS: Fourteen controversial topics were identified. A three-round Delphi Consensus process was performed including 61 experts. The aim of Round 1 was to investigate the differing views and opinions regarding these unresolved topics. In Round 2, clarifications were asked from each participant. In Round 3, the questionnaire was resent to all participants for their final vote. Consensus was reached when ≥75% of experts agreed on a specific response. RESULTS: Most experts agreed that: (1) the current periprocedural/in-hospital stroke/death thresholds for performing a carotid intervention should be lowered from 6% to 4% in patients with SxCS and from 3% to 2% in patients with AsxCS; (2) the time threshold for a patient being considered "recently symptomatic" should be reduced from the current definition of "6 months" to 3 months or less; (3) 80% to 99% AsxCS carries a higher risk of stroke compared with 60% to 79% AsxCS; (4) factors beyond the grade of stenosis and symptoms should be added to the indications for revascularization in AsxCS patients (eg, plaque features of vulnerability and silent infarctions on brain computed tomography scans); and (5) shunting should be used selectively, rather than always or never. Consensus could not be reached on the remaining topics due to conflicting, inadequate, or controversial evidence. CONCLUSIONS: The present international, multi-specialty expert-based Delphi Consensus document attempted to provide responses to several unanswered/unresolved issues. However, consensus could not be achieved on some topics, highlighting areas requiring future research.


Assuntos
Estenose das Carótidas , Acidente Vascular Cerebral , Humanos , Estenose das Carótidas/diagnóstico , Estenose das Carótidas/diagnóstico por imagem , Consenso , Técnica Delphi , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia , Constrição Patológica
2.
Ann Vasc Surg ; 102: 133-139, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38408393

RESUMO

BACKGROUND: Carotid near-occlusion (CNO) represents an anatomical-functional condition characterized by severe (more than 90%) internal carotid artery stenosis which can lead to a distal lumen diameter greater or less than 2 mm. CNO can be divided into a less severe subgroup (without lumen full collapse: diameter >2 mm) and a more severe subgroup (with lumen full collapse: diameter <2 mm). The decision for revascularization is still highly debated in Literature. The aim of the present multicenter retrospective study is to analyze the incidence of perioperative (30 days) and follow-up complications in 2 groups of patients with or without distal internal carotid lumen full collapse. METHODS: Between January 2011 and March 2023, in 5 Vascular Surgery Units, 67 patients (49 male, 73% and 18 females, 27%) with CNO underwent carotid endarterectomy: 28 (41.7%) with lumen diameter <2 mm and 39 (58.3%) with diameter >2 mm. 19 patients were symptomatic and 48 asymptomatic. The outcomes considered for comparative analysis were: perioperative neurological and cardiac complications, carotid restenosis or occlusion at follow-up. Both groups were homogeneous in terms of risk factors, morphological features and pharmacological treatments. RESULTS: In the group with lumen <2 mm, 3 perioperative major events (10.7%) occurred (1 ischemic stroke, 1 hemorrhagic stroke, 1 myocardial infarction) and 2 (7.1%) at follow-up (average 11 ± 14.5 months; 1 asymptomatic carotid occlusion, 1 hemodynamic restenosis treated with stenting). No event was recorded in the group with lumen >2 mm. CONCLUSIONS: According to our results CNO patients show different complication risk according to the presence or not of distal lumen collapse. The later seems to play a significant role in perioperative and follow-up complication rate. These results therefore support a surgical treatment only in patients with CNO without lumen full collapse.


Assuntos
Estenose das Carótidas , Endarterectomia das Carótidas , Acidente Vascular Cerebral , Feminino , Humanos , Masculino , Estudos Retrospectivos , Tratamento Conservador/efeitos adversos , Resultado do Tratamento , Estenose das Carótidas/complicações , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/cirurgia , Artérias Carótidas/cirurgia , Endarterectomia das Carótidas/efeitos adversos , Endarterectomia das Carótidas/métodos , Fatores de Risco , Constrição Patológica/etiologia , Acidente Vascular Cerebral/complicações , Stents/efeitos adversos
3.
J Endovasc Ther ; : 15266028231179874, 2023 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-37287265

RESUMO

PURPOSE: Patients undergoing carotid endarterectomy (CEA) or carotid artery stenting (CAS) are at substantially increased risk of short-term and long-term cardiac complications. Still, the role of perioperative troponin in predicting cardiac events remains unclear. The objective was to systematically summarize the existing evidence on the topic and provide directions for further research. MATERIALS AND METHODS: Studies that examined perioperative troponin values and its association with myocardial injury, and/or myocardial infarction (MI), and/or major adverse cardiac events (MACE) and postoperative mortality in exclusively CEA/CAS patients, published in English until March 15, 2022, were retrieved through a systematic search of MEDLINE and Web of Science. The study selection process was independently performed by 2 authors, while the third researcher resolved disagreements. RESULTS: Four studies with 885 participants met the inclusion criteria. Age, chronic kidney disease, presentation of carotid disease, type of closure (primary closure/venous patch/Dacron/polytetrafluoroethylene patch), coronary artery disease, chronic heart failure, and the long-term use of calcium channel blockers represent risk factors for troponin elevation, which occurred in 11% to 15.3%. Myocardial infarction and MACE occurred in 23.5% to 40%, that is, 26.5% of patients with troponin elevation, respectively, during the first 30 postoperative days. Elevated postoperative troponin levels were significantly associated with adverse cardiac events during the long-term surveillance period. The rates of cardiac-related and all-cause mortality were higher in patients with postoperative troponin elevation. CONCLUSION: Troponin measurement could be helpful in the prediction of adverse cardiac events. The predictive role of preoperative troponin, the patient population in whom routine troponin sampling should be used, and a comparison of different treatment methods/anesthesia techniques in carotid patients should be further examined. CLINICAL IMPACT: The present scoping review critically appraises the extent and nature of the existing literature data on the predictive value of troponin on the occurrence of cardiac complications in patients undergoing CEA and CAS. In particular, it provides clinicians with essential insights by systematically summarizing the core evidence and identifying knowledge gaps that may direct future research. This, in turn, may significantly alter the current clinical practice and perhaps even reduce the incidence of cardiac complications in patients undergoing CEA/CAS.

4.
Ann Vasc Surg ; 76: 342-350, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33951519

RESUMO

BACKGROUND: Carotid artery stenting (CAS) has become a valid alternative to carotid endarterectomy in stroke prevention. However, female gender is still considered as an independent risk factor for CAS procedures, potentially limiting immediate and long-term benefits. Aim of present study was to evaluate gender differences in CAS submitted patients from an Italian high-volume center. MATERIAL AND METHODS: a retrospective monocentric study has been conducted on 568 patients (366 males and 202 females), submitted to CAS, between January 2000 and December 2019. Besides gender sex, clinical anatomical, and procedural data were collected as possible factors determining the outcome, when associated to sex gender itself. Primary endpoint of this study consisted in evaluating the technical and procedural success ratio, and the incidence of major and minor stroke, transient ischemic attack, acute myocardial infarction (AMI) peri-procedurally and at medium and long term, between the male and the female population. Secondary endpoint of this study consisted in evaluating the percentage ratio of minor complications happening peri-procedurally in both genders. RESULTS: Male patients were more likely to be octogenarians, clinical history of coronary artery disease, and smokers, while diabetes was more frequent in female patients. Anatomical and plaque morphology features were not different between the two groups. Technical success was obtained in all but two patients (99,6%), while procedural success was 95% (538/566 patients). During the peri-procedural time, no major stroke, 16 minor strokes (2,81%, 2,45% males vs. 3,45% females, P= 0,48), and 11 transient ischemic attack (2,18% males vs. 1,48% females, P= 0,56) were recorded. At a medium follow-up 57 months, 32 stroke (8 major strokes, 24 minor strokes) episodes (5,6%, males 5,7% vs. females 5,4%, P= 0,88), 24 AMIs (4,2%, males 4,6% vs. females 3,46%, P= 0,5;), 13 restenosis (2,8%, males 2,4% vs. females 1,9%, P= 0,71) and 223 deaths (39,2%, males 34,9% vs. females 47%, P= 0,0048) were noted. CONCLUSIONS: Our results showed no differences in immediate, and long-term CAS outcomes between gender. Larger, prospective studies are required to assess the real importance and significance of gender in determining CAS procedures' benefit and outcome.


Assuntos
Estenose das Carótidas/terapia , Procedimentos Endovasculares/instrumentação , Disparidades nos Níveis de Saúde , Stents , Idoso , Estenose das Carótidas/complicações , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Ataque Isquêmico Transitório/etiologia , Itália , Masculino , Infarto do Miocárdio/etiologia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores Sexuais , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Resultado do Tratamento
5.
Ann Vasc Surg ; 74: 183-193, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33549787

RESUMO

PURPOSE: to evaluate the impact of bi- and 3-dimensional preoperative aortic morphological features and their immediate postoperative variations on the outcome of abdominal aortic aneurysms (AAA) treated by endovascular exclusion with standard devices (EVAR). MATERIALS AND METHODS: Double centre retrospective analysis of prospectively collected registry data of EVAR patients. For all patients, preoperative and 30-day computed tomographic angiography images (CTA) were reviewed. Preoperative maximum AAA diameter >59 mm and volume >159 cm3, and any 30-day postoperative increasing at CTA, were considered as potentially influencing the outcome. The outcome measures were: primary technical success; 30-day, 1-year, and mean follow-up reintervention, all-cause and AAA-related mortality rates, and also endoleak-related reinterventions. RESULTS: Three hundred and thrity-three patients were enrolled. Mean preoperative and 30-day AAA diameter and volume were 50.4 mm ± 11.8 vs. 49.1 mm ± 12.1, and 112.9 cm3 ± 79.5 vs. 112.1 cm3 ± 80.5, respectively. Primary technical success was achieved in all cases. At 34.9 months follow-up, cumulative reintervention rate was 12.0%, mortality rates 7.2%, without AAA-related deaths. Endoleak-related reintervention rate was 7.5%. At uni- and multi-variate analysis, preoperative AAA diameter >59 mm, and AAA volume >159 cm3 were significantly associated to reintervention (P = 0.012; P = 0.002), and reintervention and death (P = 0.002; P = 0.001) during follow-up. Additionally, any increase in postoperative AAA diameter or volume was significantly associated with reintervention (P = 0.001, P = 0.001) and reintervention and death (P = 0.006, P = 0.001). Endoleak-related reintervention were also significantly associated with all of the analysed morphological parameters (P = 0.019, P = 0.005, P = 0.005, and P = 0.002, respectively). CONCLUSIONS: Patients with larger baseline AAA size and volume as well as unfavourable early remodelling of the sac are associated to worse long-term EVAR outcome.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico , Aneurisma da Aorta Abdominal/mortalidade , Aortografia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Sistema de Registros , Retratamento , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Cidade de Roma , Fatores de Tempo , Resultado do Tratamento
6.
Ann Vasc Surg ; 63: 458.e1-458.e6, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31648033

RESUMO

The aim of this study is to report the outcome of immediate and direct revascularization by mechanical thrombectomy in acute limb ischemia due to thrombosed popliteal artery aneurysm (PAA). Two patients with acute limb ischemia due to PAA thrombosis were admitted at our hospital, and immediately treated by mechanical thrombectomy (Indigo System). The first patient had a complete recanalization after thrombectomy, while the second one required urokinase infusion (12 hr) due to a suboptimal result. After revascularization, both patients were treated by a polytetrafluoroethylene bypass to definitively exclude PAA. Follow-up showed the patency of the femoropopliteal bypass with good distal outflow. In these 2 reported cases, the Indigo System® has proven to be safe and effective, allowing an immediate limb reperfusion, reducing the necessity for thrombolytic drug infusion.


Assuntos
Aneurisma/terapia , Isquemia/terapia , Artéria Poplítea , Trombectomia/instrumentação , Trombose/terapia , Doença Aguda , Idoso , Aneurisma/diagnóstico por imagem , Aneurisma/fisiopatologia , Humanos , Isquemia/diagnóstico por imagem , Isquemia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Artéria Poplítea/diagnóstico por imagem , Artéria Poplítea/fisiopatologia , Sucção/instrumentação , Trombose/diagnóstico por imagem , Trombose/fisiopatologia , Resultado do Tratamento , Grau de Desobstrução Vascular
7.
Ann Vasc Surg ; 67: 274-282, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32209404

RESUMO

BACKGROUND: The aim of the present study was to evaluate early-, mid-, and long-term outcomes in an unselected population of patients treated for abdominal aortic aneurysms (AAAs) by endovascular aneurysm repair (EVAR) with different commercially available off-the-shelf devices. MATERIALS AND METHODS: A retrospective study was conducted on a prospectively compiled computerized database on patients presenting an infrarenal AAA treated between January 2008 and December 2015 in a high-volume Italian tertiary referral Center. Demographic, clinical, and specific morphological features were considered as potentially influencing the outcomes and the type of the implanted device. Outcome measures were procedure-related reintervention, AAA-related, and all-cause mortality rates at 30-day, 12-month, and long-term follow-up. Reinterventions considered for the analysis were AAA rupture, graft infection, type I or III endoleaks, type II endoleaks with sac enlargement > 5 mm, graft stenosis or occlusions, procedures related to renal or visceral ischemia, and reintervention for access vessel injury. RESULTS: Of 498 EVAR procedures performed for elective infrarenal AAA treatment during the entire study period, 479 patients were enrolled, the mean age was 73.5 ± 7.34 years (range 51-91), and 416 (86.84%) were men. The mean maximum AAA diameter was 52.02 ± 8.04 mm (range 39-90.2), a maximum AAA diameter ≥59 mm was recorded in 107 patients (22.33%), and an aortic neck length was <10 mm in 137 (28.60%). Technical success was achieved in all patients. At a mean follow-up of 52.97 ± 26.16 months (range 1-120), overall reintervention and death rates were 8.14% and 20.04%, respectively, without AAA-related deaths. At univariate analysis, hypertension was the only demographical variable found to be associated with higher risk of reintervention, P = 0.04 (OR: 2.34; CI 95%: 1.00-5.42). Furthermore, male sex (P = 0.02; OR: 2.62; CI 95%: 1.09-6.27) and chronic renal insufficiency (P = 0.003; OR: 2.08; CI 95%: 1.27-3.42) were associated with higher mortality rates. AAA diameter ≥59 mm was statistically associated with a higher rate of both reintervention and mortality: P < 0.001 (OR: 9.05; CI 95%: 4.52-18.11) and <0.001 (4.00; 2.46-6.49), respectively. CONCLUSIONS: Our experience seems to suggest that EVAR could be safely and effectively performed in an unselected patients' population, with encouraging results up to a ten-year follow-up.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Bases de Dados Factuais , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Cidade de Roma , Stents , Fatores de Tempo , Resultado do Tratamento
8.
J Endovasc Ther ; 26(1): 105-112, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30591005

RESUMO

PURPOSE: To compare outcomes of patients treated for pararenal aortic aneurysms using fenestrated endovascular aneurysm repair (fEVAR) vs open surgical repair (OSR) in 3 high-volume centers. MATERIALS AND METHODS: A multicenter retrospective analysis was conducted of 200 pararenal abdominal aortic aneurysm patients electively treated with OSR (n=108) or fEVAR (n=92) from 1998 to 2015 at 3 tertiary institutions. Endpoints were 30-day morbidity and mortality, late reinterventions, visceral artery occlusion, and mortality. Analysis was conducted on the entire population and on a propensity score-matched population constructed on age, gender, coronary artery disease (CAD), and chronic renal failure. RESULTS: In the total cohort, fEVAR patients were significantly (p<0.001) older and had higher frequencies of CAD (p<0.001) and previous stroke (p=0.003). OSR patients had higher risk of perioperative morbidity (OR 2.5, 95% CI 1.09 to 5.71, p=0.033), specifically respiratory failure (OR 4.06, 95% CI 1.12 to 4.72, p=0.034). These findings were confirmed in the propensity-adjusted analysis, where cardiac complications were also higher after OSR (OR 12.8, 95% CI 0.07 to 0.21, p=0.02). No difference in perioperative mortality (2.2% in fEVAR vs 1.9% in OSR) was identified. Mean follow-up was 50 months (range 0-119). Four-year results showed higher survival (91.2% vs 69.3%, p=0.02) and freedom from reintervention (95.6% vs 77.8%, p=0.01) after OSR in the unmatched population, with a small but significant (p=0.021) difference in the risk of late visceral artery occlusion/stenosis after fEVAR. On propensity analysis, no differences in late survival were found between groups. CONCLUSION: fEVAR and OSR may afford similar early and midterm survival rates. Higher risks of perioperative systemic complications after OSR are counterbalanced by higher risks of late visceral vessel patency issues and need for reintervention after fEVAR. Both procedures are safe and effective in the long term in experienced centers, where patient evaluation should drive the treatment strategy.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Bases de Dados Factuais , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Alemanha , Hospitais com Alto Volume de Atendimentos , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Intervalo Livre de Progressão , Pontuação de Propensão , Retratamento , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo
9.
Ann Vasc Surg ; 60: 479.e5-479.e9, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31195105

RESUMO

We report a case of an 18-year-old woman who developed a delayed pseudoaneurysm of the right anterior tibial artery (ATA), 14 days after a knife accidental trauma. The patient was admitted to our emergency department for acute onset of pain in the right limb after a domestic trauma. At a physical examination, the limb was tense and tender, with a pulsatile mass in the anterior compartment. Femoral, popliteal, and distal pulses were palpable on both limbs. Duplex ultrasound scan (DUS) and computed tomography angiography showed the presence of an ATA pseudoaneurysm. An urgent endovascular treatment was performed under local anesthesia via percutaneous access. Pseudoaneurysm was excluded implanting 2 coronary covered balloon-expandable stents (BeGraft; Bentley Innomed GmbH, Hechingen, Germany). Postoperative course was uneventful and the patient was discharged on the second postoperative day under dual antiplatelet therapy. One- and 13-month scheduled follow-up visits and DUS revealed the presence of a normal pedal pulse, complete pseudoaneurysm exclusion, and patency of the stent grafts and the entire ATA with triphasic waveforms. In conclusion, endovascular treatment of an ATA pseudoaneurysm seems to be a feasible option. Further experience with this technique is needed to validate its safety and long-term patency, especially in young and healthy subjects.


Assuntos
Falso Aneurisma/terapia , Angioplastia com Balão , Artérias da Tíbia/lesões , Lesões do Sistema Vascular/terapia , Ferimentos Perfurantes/complicações , Adolescente , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Angioplastia com Balão/instrumentação , Feminino , Humanos , Stents , Artérias da Tíbia/diagnóstico por imagem , Resultado do Tratamento , Lesões do Sistema Vascular/diagnóstico por imagem , Lesões do Sistema Vascular/etiologia , Ferimentos Perfurantes/diagnóstico
10.
Ann Vasc Surg ; 56: 224-232, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30502380

RESUMO

BACKGROUND: The aim of this work is describing incidence and fate of type 2 endoleaks (T2ELs) in a multicentric cohort of patients treated by endovascular aneurysms repair using the Ovation device (Endologix) and comparing them with a group treated using the Excluder (W. L. Gore & Associates). METHODS: This is a retrospective study conducted on 261 patients treated using the Ovation device and 203 using the Excluder. Outcomes were intraprocedural, 30-day, 12-month, and mean time follow-up T2EL incidence and related reinterventions. Patent inferior mesenteric artery (IMA), ≥3 lumbar arteries (LAs), intrasac thrombus volume, the mean diameter of common and external iliac arteries, external iliac artery stenosis (>70%), diameter ≤5 mm, iliac tortuosity ratio ≤0.5, thrombosis, and calcification were noted and considered as potentially influencing outcomes. RESULTS: Patients of the Ovation group presented significantly more thrombosed, calcified, and tortuous iliac vessels than those in the Excluder group. No significant differences were noted in sac thrombosis, IMA, and LA patency. At completion angiography, T2EL was evident in 57 Ovation and 46 Excluder patients (P = 0.832). At 1 month, it was evident in 33 Ovation group and 28 Excluder group patients (P = 0.726). At 12-month and mean time (30.14 months) follow-up, no differences were evident between the 2 groups (P = 0.940 and 0.951, respectively). The log-rank test showed that the rate of T2EL-related reintervention was not different between the 2 groups (P = 0.46). Regarding anatomical characteristics, a statistically significant difference was not observed between patients presenting or not with T2EL (P > 0.05). CONCLUSIONS: Data showed no significant differences in terms of T2EL incidence between the 2 study groups. None of preoperative anatomical features were found to be significantly associated with the appearance of T2EL.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Endoleak/epidemiologia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/epidemiologia , Aortografia/métodos , Angiografia por Tomografia Computadorizada , Endoleak/diagnóstico por imagem , Feminino , Humanos , Incidência , Itália/epidemiologia , Masculino , Tomografia Computadorizada Multidetectores , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
11.
Ann Vasc Surg ; 53: 271.e1-271.e5, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30092428

RESUMO

We report an unusual complication of Chocolate nitinol-constraining structure after right superficial femoral artery (SFA) angioplasty. The procedure was performed by vascular surgeons in an operating theater equipped by a portable fluoroscopy unit. Under local anesthesia, by a contralateral approach, a 7F introducer sheath was advanced through the proximal portion of the right common iliac artery. Owing to the severe aorto-iliac vessels calcification, it was not possible to place the introducer sheath into a more distal vessel, as planned. After external iliac artery (EIA) stenting (7 × 80 mm Eluvia), SFA obstruction was intraluminal crossed, and a 6 × 120 mm nitinol-constrained balloon (Chocolate; Medtronic) was advanced in place and inflated. Once the balloon came out, the nitinol-constraining structure was not attached to the balloon surface. Under fluoroscopy, the crashed nitinol mesh was identified at distal edge of previously positioned EIA stent. To prevent mesh migration, it was fixed by covering with a 7 × 40 mm stent. The procedure was then successfully completed, as planned. One-month, postoperative computed tomography angiography showed complete expansion of the stents and no significant residual stenosis (>30%) in EIA, and SFA. Chocolate's mesh was still evident between the stent and the iliac artery wall, in absence of further complications. A 3 months follow-up, patient was still completely asymptomatic for claudication.


Assuntos
Ligas , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/instrumentação , Artéria Femoral/cirurgia , Artéria Ilíaca/cirurgia , Doença Arterial Periférica/cirurgia , Stents , Idoso , Angiografia por Tomografia Computadorizada , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Humanos , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/fisiopatologia , Masculino , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Desenho de Prótese , Falha de Prótese , Resultado do Tratamento , Grau de Desobstrução Vascular
12.
J Endovasc Ther ; 24(6): 846-851, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28891375

RESUMO

PURPOSE: To describe results of AFX unibody stent-graft treatment for TransAtlantic Inter-Society Consensus (TASC) D aortoiliac occlusive disease (AIOD) with coexistent abdominal aortic aneurysm (AAA). METHODS: A retrospective analysis was conducted of 21 consecutive patients (mean age 73.6±6.4 years; 17 men) with TASC D AIOD plus AAA (diameter >3.5 cm) treated electively using the AFX stent-graft. Common iliac artery (CIA) and external iliac artery (EIA) stenosis or occlusion was reported. Outcome measures were technical and clinical success, improvement in ankle-brachial index (ABI), and improvement in Rutherford category. Immediate and midterm patency, AAA exclusion, major adverse events (MAE), and mortality were also evaluated. RESULTS: After AFX deployment (100% technical success), 18 EIAs required adjunctive stenting (none required in the CIA). One patient required a reintervention for closure device failure. At 30-day follow-up, no death or MAE was recorded. Improvement in ABI was registered in all patients (mean 0.91±0.11), with 100% primary patency. At a mean follow-up of 25.2±11.1 months, primary patency was maintained in all cases. No death or amputation occurred; 2 patients had a myocardial infarction. Improvement in ABI was maintained (0.88±0.13) as well as Rutherford category. CONCLUSION: This study examined the use of the AFX unibody stent-graft for the treatment of TASC D AIOD with concomitant AAA. The AFX stent-graft appears to be a safe and effective solution for these complex lesions, with low morbidity and mortality.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Aneurisma Ilíaco/cirurgia , Stents , Idoso , Idoso de 80 Anos ou mais , Índice Tornozelo-Braço , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Aneurisma Ilíaco/fisiopatologia , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
13.
Ann Vasc Surg ; 44: 421.e9-421.e13, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28483632

RESUMO

To report a case of pararenal aortic aneurysm (PAAA) with narrowed iliac arteries treated by the chimney technique combined with the INCRAFT® AAA stent graft system. A 75-year-old man was diagnosed with a 55-mm PAAA. Patient was judged unfit for open repair and for standard endovascular aneurysm repair (EVAR) due to its clinical and anatomical requirements. Custom-made fenestrated device (FEVAR) was excluded due to the presence of narrowed and heavily calcified iliac axes. Consequently, patient underwent auspicious endovascular aneurysm repair with the INCRAFT System and chimney grafts in the superior mesenteric artery and both renal arteries. At 12 months' follow-up, patient was in good clinical condition, with preserved renal function. Computed tomographic angiography revealed inceptive shrinkage of the aneurysm with patency of aortic and visceral grafts even in the presence of a low-flow type Ia endoleak. Chimney grafts (CGs) combined with the low-profile INCRAFT System seem to be feasible for treating PAAA, in high-risk patients unfit for standard EVAR or FEVAR devices.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Artéria Ilíaca , Stents , Idoso , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Aortografia/métodos , Angiografia por Tomografia Computadorizada , Humanos , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/fisiopatologia , Masculino , Desenho de Prótese , Resultado do Tratamento , Grau de Desobstrução Vascular
14.
Ann Vasc Surg ; 40: 296.e15-296.e19, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27908810

RESUMO

We report a case of a compassionate treatment of a ruptured thoracoabdominal aortic aneurysm in a 92-year-old patient. The patient was admitted to our emergency department for acute onset of pain irradiating to the back. Computed tomography angiography showed the presence of a thoracoabdominal aortic aneurysm with a contained rupture at infrarenal level. Given the presence of a relative healthy visceral aorta, we decided to treat the patient by Ovation (Endologix, Irvine, CA) implantation in an off-label fashion. Procedure was performed by bilateral percutaneous access. Completion angiography showed the good stent-graft apposition with complete aneurysm exclusion. The patient was discharged on the third postoperative day. The 1-month follow-up confirmed the good procedural result; aneurysm was completely excluded without further thoracic dilatation.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Ruptura Aórtica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Stents , Idoso de 80 Anos ou mais , Aneurisma da Aorta Torácica/diagnóstico por imagem , Ruptura Aórtica/diagnóstico por imagem , Aortografia/métodos , Ensaios de Uso Compassivo , Angiografia por Tomografia Computadorizada , Aprovação de Equipamentos , Emergências , Feminino , Humanos , Rotulagem de Produtos , Desenho de Prótese , Resultado do Tratamento
15.
Ann Vasc Surg ; 43: 310.e9-310.e12, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28461183

RESUMO

We report a case of acute limb ischemia (ALI) due to a thromboembolism from a persistent sciatic artery (PSA) pseudoaneurysm precipitated by a fractured stent. Patient, previously treated for ALI by fibrinolysis and stent implantation, presented with a PSA pseudoaneurysm (undetected during first hospitalization), stent fracture (SF), and occlusion of vessels below the knee. Fibrinolysis was performed, restoring direct flow to the foot. A week later, an endovascular procedure was attempted to reline SF and exclude the PSA pseudoaneurysm by deployment of two 13 × 100-mm peripheral endografts (Viabahn; W.L. Gore & Associates, Flagstaff, AZ). At 1-year follow-up, patient was asymptomatic without further clinical events.


Assuntos
Falso Aneurisma/terapia , Procedimentos Endovasculares/instrumentação , Isquemia/terapia , Extremidade Inferior/irrigação sanguínea , Falha de Prótese , Stents , Tromboembolia/terapia , Doença Aguda , Idoso , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Fibrinólise , Humanos , Isquemia/diagnóstico por imagem , Isquemia/fisiopatologia , Masculino , Fluxo Sanguíneo Regional , Tromboembolia/diagnóstico por imagem , Tromboembolia/etiologia , Resultado do Tratamento , Grau de Desobstrução Vascular
16.
Ann Vasc Surg ; 45: 253-261, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28689943

RESUMO

BACKGROUND: The objective of the study was to report immediate and midterm results of an unselected population of patients treated for abdominal aortic aneurysms (AAAs) by endovascular aneurysm repair (EVAR) using the Ovation stent graft. METHODS: A double-center retrospective study was conducted on a prospectively collected database between 2012 and 2015. One hundred fifty-six elective patients were included. The outcome measures considered for analysis were primary technical success, 30-day and midterm reinterventions, and all-cause and AAA-related mortality rates. The presence of an aortic neck ≤10 mm, and of a noncylindrical aortic neck, as well as a narrowed aortic bifurcation was defined as an aortic bifurcation average diameter (ABaverage) ≤ 18 mm or an ABarea ≤ 20 mm2, and an external iliac artery diameter ≤5 mm was considered as independent factors potentially influencing the outcome. RESULTS: Male patients totaled 128 (82.1%), and mean age was 74.83 ± 6.76 years (range: 56-91). Mean aortic diameter was 57.15 ± 8.77 mm, mean diameter at inferior renal artery level + 13 was 24.44 ± 3.31 mm, and mean aortic neck length was 18.77 ± 8.45 mm. Fifty-four patients (34.6%) had an aortic neck ≤10 mm, and cylindrical aortic neck shape was present in 34 patients (21.8%). Regarding the aortic bifurcation (AB), 31 patients (19.9%) presented ABaverage ≤ 18 mm, and 35 (22.4%) an ABarea ≤ 20 mm2. Technical success was achieved in all cases. At 30-day follow-up, 2 type I endoleaks (1.3%) were detected. One patient was successfully treated endovascularly by proximal aortic cuff implantation, while the other patient refused further treatment. Three-month unscheduled computed tomographic angiography shows endoleak resolution and complete aneurysm seal. One patient suffered from a limb graft occlusion, managed by medical treatment. At a mean follow-up time of 20.4 ± 8.8 (1-60) months, 6 reinterventions were reported, including 2 embolizations for type II endoleak and 4 for iliac and femoral vessel occlusive disease. Log-rank test on preoperative anatomical features showed no significant differences in terms of freedom from reinterventions, and P values were 0.653 for aortic neck length ≤10 mm, 0.309 for noncylindrical aortic neck length shape, 0.520 for ABaverage ≤ 18 mm, 0.604 for ABarea ≤ 20 mm2, and 0.421 for external iliac artery diameter ≤5 mm. CONCLUSIONS: Our initial experience suggests that in an unselected patient population undergoing AAA repair, EVAR by Ovation stent graft can be performed safely with satisfactory immediate and midterm outcomes.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Bases de Dados Factuais , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Itália , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
17.
Ann Vasc Surg ; 34: 270.e19-24, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27174349

RESUMO

We report a case of an early type Ia endoleak after endovascular aneurysm repair (EVAR) of an abdominal aortic aneurysm by Ovation Stent Graft implantation and spontaneously resolved without further reintervention. The patient presents a conical aortic neck, but EVAR was performed within the instruction for use proposed by manufactory. At completion angiography, a low-flow type Ia endoleak was present and left untreated. Computed tomographic angiography performed on the third postoperative day showed infolding of the 2 sealing rings. The patient was dismissed without further treatment. At 3-month follow-up, the leak appeared spontaneously sealed with partial expansion of the 2 rings.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortografia , Angiografia por Tomografia Computadorizada , Endoleak/diagnóstico por imagem , Humanos , Masculino , Desenho de Prótese , Remissão Espontânea , Fatores de Tempo
18.
Ann Vasc Surg ; 32: 133.e1-5, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26806247

RESUMO

The coral reef aorta (CRA) is a rare syndrome commonly referred to a distribution of calcified plaques in the visceral part of the aorta. Because those plaques can cause malperfusion of the lower limbs, visceral ischemia or renovascular hypertension, surgical treatment is recommended. Transaortic endarterectomy is accepted as a standard repair and it is often performed through an extensive thoracoabdominal approach. CRA has been reported in association with polidistrectual atherosclerotic disease, such as Leriche syndrome. When these 2 conditions coexist, surgical invasivity increases raising several issues concerning the type of surgical access and the revascularization techniques. We report the case of a patient with CRA and Leriche syndrome treated by simultaneous aortic endarterectomy and aortibifemoral bypass at our institution. Intervention was performed through left lumbotomy at 10th intercostal space extended by a left pararectal abdominal incision with section of 11th rib. Through extraperitoneal access visceral vessels were isolated. Aortic cross-clamping was performed at supraceliac and infrarenal levels and a longitudinal arteriotomy was performed on the posterolateral wall of visceral aorta for an overall 4-cm extension. Aortic endarterectomy was then performed and complete plaque excision was easily achieved. Superior mesenteric artery angioplasty was then performed by a DeBakey dilator, gaining an optimal backflow. The aortotomy was then closed with running 3-0 polypropylene suture. Subsequently, through a transperitoneal access an aortobi-femoral bypass was performed by a Dacron knitted graft. Postoperative course was uneventful. At a 6-month follow-up, the patient is in good clinical condition with normal patency of visceral vessels.


Assuntos
Doenças da Aorta/cirurgia , Implante de Prótese Vascular , Endarterectomia , Síndrome de Leriche/cirurgia , Calcificação Vascular/cirurgia , Angioplastia , Doenças da Aorta/complicações , Doenças da Aorta/diagnóstico por imagem , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Síndrome de Leriche/complicações , Síndrome de Leriche/diagnóstico por imagem , Pessoa de Meia-Idade , Polietilenotereftalatos , Desenho de Prótese , Técnicas de Sutura , Resultado do Tratamento , Calcificação Vascular/complicações , Calcificação Vascular/diagnóstico por imagem
19.
Ann Vasc Surg ; 30: 198-204, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26408970

RESUMO

BACKGROUND: To preliminary report on epidemiology, risk factors, diagnosis, treatments, and outcomes in a multicenter series of patients treated for endovascular aortic repair (EVAR) infection and detected by an Italian National enquiry. METHODS: From June 2012, 26 cases of abdominal aortic endograft infection were collected by a National Enquiry and recorded in the Italian National Registry of Infection in EVAR. Cases collected were available for patients submitted to EVAR implantation from January 2004 to June 2013. RESULTS: Mean time from EVAR treatment to infection diagnosis was 20.5 ± 20.3 months (range, 1-72). In 6 cases (23.1%), an aortoenteric fistula (AEF) was detected. Positive microbiologic cultures were found in 20 patients (76.9%). More than 1 infectious agent was found in 6 cases (19.2%). EVAR infection treatment was conservative in 4 cases, endovascular in 2. Endograft excision was performed in 10 cases by conventional treatment (aortic stump + extra-anatomic bypass) and in 10 cases by in situ reconstruction (cryopreserved allograft or rifampin-soaked silver Dacron graft). A 30-day mortality was 38.4% (10 of 26 cases), 3 patients died from 2 to 24 months after infection treatment, accounting for a mean time from infection treatment to death of 1.25 ± 0.62 months. Mortality rates were 50% in all treatment groups. In those survived (13 of 26 cases) recurrence-free follow-up after infection treatment was 27.9 ± 22.4 months (range, 2-74). Four patients with AEF died in the first month after treatment (66.6%). Suprarenal endografts required supraceliac aortic cross-clamping for removal. Supraceliac cross-clamping was burdened by higher mortality rates than infrarenal cross-clamping (71.4% vs. 30.7%). CONCLUSIONS: EVAR infection diagnosis is burdened by extremely high mortality rates. Prospective registries could help monitoring outcomes in EVAR infection patients and, possibly, developing new surveillance protocols in patients at high risk of recurrence.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Infecções Relacionadas à Prótese/epidemiologia , Sistema de Registros , Humanos , Incidência , Itália/epidemiologia , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/terapia , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
20.
J Endovasc Ther ; 22(1): 110-5, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25775690

RESUMO

PURPOSE: To retrospectively review all patients undergoing late open conversion (LOC) after endovascular aneurysm repair (EVAR) in order to identify any clinical or technical predictors of poor outcome. METHODS: Twenty-six consecutive patients (24 men; mean age 74.7 ± 8.3 years) underwent LOC between June 2006 and April 2013 at our institution. The mean interval from index EVAR to LOC was 40.4 ± 29.2 months (range 5-93 months). The indication for LOC was endoleak in 14 (54%) patients and infection in 12 (46%): 2 (8%) patients with endoleak had a ruptured aneurysm and 6 (23%) patients with infection had a recurrent secondary aortoesophageal fistula (sAEF). RESULTS: In all 12 cases of infection and in 12 of 14 endoleaks, the entire endograft was explanted. A rifampin-soaked Dacron silver graft was implanted in all patients with infection. Patients with any infection and with recurrent AEF required more blood units than patients with endoleak (6.40 vs. 1.86, p = 0.045; 6.76 vs. 1.86, p = 0.0036, respectively). Compared with endoleak, the duration of conversions in the setting of infection (274 vs. 316 minutes, p = 0.42) and recurrent sAEF (274 vs. 396 minutes, p = 0.021) was longer. All patients with recurrent sAEF died at a mean 3.0 ± 2.5 days after LOC from proximal anastomosis disruption and hemorrhagic shock (n = 2), myocardial infarction (n = 2), acute stroke (n = 1), or persistent sepsis (n = 1). Perioperative mortality was significantly higher in patients with endograft infection (6/12, p = 0.002) and in cases of supraceliac cross-clamping (4/6, p = 0.003). The association of infection with supraceliac cross-clamping was a strong predictor for perioperative mortality (p < 0.001). CONCLUSION: In our experience, endograft infection led to greater perioperative mortality after LOC. Recurrent aortoenteric fistula in association with supraceliac cross-clamping is a strong predictor of poor outcome. Patients surviving the perioperative period may have good chances of long-term survival.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Fístula Esofágica/microbiologia , Stents/efeitos adversos , Fístula Vascular/microbiologia , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/uso terapêutico , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/mortalidade , Ruptura Aórtica , Prótese Vascular/efeitos adversos , Conversão para Cirurgia Aberta/métodos , Conversão para Cirurgia Aberta/mortalidade , Remoção de Dispositivo , Endoleak/etiologia , Fístula Esofágica/etiologia , Fístula Esofágica/mortalidade , Fístula Esofágica/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Recidiva , Reoperação , Estudos Retrospectivos , Fatores de Risco , Análise de Sobrevida , Resultado do Tratamento , Fístula Vascular/etiologia , Fístula Vascular/mortalidade , Fístula Vascular/terapia