Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
J Physiol ; 599(17): 4183-4195, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34174090

RESUMO

KEY POINTS: Recent animal and human physiology studies indicate that noradrenergic and muscarinic processes are key mechanisms that mediate pharyngeal muscle control during sleep. The noradrenergic agent reboxetine combined with the anti-muscarinic hyoscine butylbromide has recently been shown to improve upper airway function during sleep in healthy individuals. However, whether these findings translate to the clinically relevant patient population of people with obstructive sleep apnoea (OSA), and the effects of the agents on OSA severity, are unknown. We found that reboxetine plus hyoscine butylbromide reduced OSA severity, including overnight hypoxaemia, via increases in pharyngeal muscle responsiveness, improvements in respiratory control and airway collapsibility without changing the respiratory arousal threshold. These findings provide mechanistic insight into the role of noradrenergic and anti-muscarinic agents on upper airway stability and breathing during sleep and are important for pharmacotherapy development for OSA. ABSTRACT: The noradrenergic agent reboxetine combined with the anti-muscarinic hyoscine butylbromide has recently been shown to improve upper airway function during sleep in healthy individuals. However, the effects of this drug combination on obstructive sleep apnoea (OSA) severity are unknown. Accordingly, this study aimed to determine if reboxetine plus hyoscine butylbromide reduces OSA severity. Secondary aims were to investigate the effects on key upper airway physiology and endotypic traits. Twelve people with OSA aged 52 ± 13 years, BMI = 30 ± 5 kg/m2 , completed a double-blind, randomised, placebo-controlled, crossover trial (ACTRN12617001326381). Two in-laboratory sleep studies with nasal mask, pneumotachograph, epiglottic pressure sensor and bipolar fine-wire electrodes into genioglossus and tensor palatini muscles were performed separated by approximately 1 week. Each participant received either reboxetine (4 mg) plus hyoscine butylbromide (20 mg), or placebo immediately prior to sleep. Polysomnography, upper airway physiology and endotypic estimates of OSA were compared between conditions. Reboxetine plus hyoscine butylbromide reduced the apnoea/hypopnoea index by (mean ± SD) 17 ± 17 events/h from 51 ± 30 to 33 ± 22 events/h (P = 0.005) and nadir oxygen saturation increased by 6 ± 5% from 82 ± 5 to 88 ± 2% (P = 0.002). The drug combination increased tonic genioglossus muscle responsiveness during non-REM sleep (median [25th, 75th centiles]: -0.007 [-0.0004, -0.07] vs. -0.12 [-0.02, -0.40] %maxEMG/cmH2 O, P = 0.02), lowered loop gain (0.43 ± 0.06 vs. 0.39 ± 0.07, P = 0.01), and improved airway collapsibility (90 [69, 95] vs. 93 [88, 96] %eupnoea, P = 0.02), without changing the arousal threshold (P = 0.39). These findings highlight the important role that noradrenergic and muscarinic processes have on upper airway function during sleep and the potential for pharmacotherapy to target these mechanisms to treat OSA.


Assuntos
Antagonistas Muscarínicos , Apneia Obstrutiva do Sono , Pressão Positiva Contínua nas Vias Aéreas , Estudos Cross-Over , Humanos , Hidrocarbonetos Bromados , Reboxetina , Escopolamina , Sono , Apneia Obstrutiva do Sono/tratamento farmacológico
2.
Respirology ; 26(9): 878-886, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34164887

RESUMO

BACKGROUND AND OBJECTIVE: Atomoxetine combined with oxybutynin (Ato-Oxy) has recently been shown to reduce obstructive sleep apnoea (OSA) severity by >60%. However, Ato-Oxy also modestly reduced the respiratory arousal threshold, which may decrease sleep quality/efficiency. We sought to investigate the additional effect of zolpidem with Ato-Oxy on sleep efficiency (primary outcome), the arousal threshold, OSA severity, other standard polysomnography (PSG) parameters, next-day sleepiness and alertness (secondary outcomes). METHODS: Twelve participants with OSA received 10 mg zolpidem plus Ato-Oxy (80-5 mg, respectively) or Ato-Oxy plus placebo prior to overnight in-laboratory PSG according to a double-blind, randomized, crossover design (1-week washout). Participants were fitted with an epiglottic catheter, a nasal mask and pneumotachograph to quantify arousal threshold and airflow. Next-day sleepiness and alertness were assessed via the Karolinska Sleepiness Scale and a driving simulation task. RESULTS: The addition of zolpidem increased sleep efficiency by 9% ± 13% (80.9% ± 16.9% vs. 88.2% ± 8.2%, p = 0.037) and the respiratory arousal threshold by 17% ± 18% (-26.6 ± 14.5 vs. -33.8 ± 20.3 cm H2 O, p = 0.004) versus Ato-Oxy + placebo. Zolpidem did not systematically change OSA severity. Combination therapy was well tolerated, and zolpidem did not worsen next-day sleepiness. However, median steering deviation during the driving simulator task increased following the zolpidem combination. CONCLUSION: Zolpidem improves sleep efficiency via an increase in the respiratory arousal threshold to counteract potential wake-promoting properties of atomoxetine in OSA. These changes occur without altering the rate of respiratory events or overnight hypoxaemia. However, while the addition of zolpidem does not increase next-day perceived sleepiness, caution is warranted given the potential impact on next-morning objective alertness.


Assuntos
Apneia Obstrutiva do Sono , Sono , Nível de Alerta , Cloridrato de Atomoxetina , Humanos , Ácidos Mandélicos , Apneia Obstrutiva do Sono/tratamento farmacológico , Zolpidem
3.
J Physiol ; 598(3): 567-580, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31782971

RESUMO

KEY POINTS: Impaired pharyngeal anatomy and increased airway collapsibility is a major cause of obstructive sleep apnoea (OSA) and a mediator of its severity. Upper airway reflexes to changes in airway pressure provide important protection against airway closure. This study shows increased pharyngeal collapsibility and attenuated genioglossus reflex responses during expiration in people with OSA. ABSTRACT: Upper airway collapse contributes to obstructive sleep apnoea (OSA) pathogenesis. Pharyngeal dilator muscle activity varies throughout the respiratory cycle and may contribute to dynamic changes in pharyngeal collapsibility. However, whether upper airway collapsibility and reflex responses to changes in airway pressure vary throughout the respiratory cycle in OSA is unclear. Thus, this study quantified differences in upper airway collapsibility and genioglossus electromyographic (EMG) activity and reflex responses during different phases of the respiratory cycle. Twelve middle-aged people with OSA (2 female) were fitted with standard polysomnography equipment: a nasal mask, pneumotachograph, two fine-wire intramuscular electrodes into the genioglossus, and a pressure catheter positioned at the epiglottis and a second at the choanae (the collapsible portion of the upper airway). At least 20 brief (∼250 ms) pressure pulses (∼-11 cmH2 O at the mask) were delivered every 2-10 breaths during four conditions: (1) early inspiration, (2) mid-inspiration, (3) early expiration, and (4) mid-expiration. Mean baseline genioglossus EMG activity 100 ms prior to pulse delivery and genioglossus reflex responses were quantified for each condition. The upper airway collapsibility index (UACI), quantified as 100 × (nadir choanal - epiglottic pressure)/nadir choanal pressure during negative pressure pulses, varied throughout the respiratory cycle (early inspiration = 43 ± 25%, mid-inspiration = 29 ± 19%, early expiration = 83 ± 19% and mid-expiration = 95 ± 11% (mean ± SD) P < 0.01). Genioglossus EMG activity was lower during expiration (e.g. mid-expiration vs. mid-inspiration = 76 ± 23 vs. 127 ± 41% of early-inspiration, P < 0.001). Similarly, genioglossus reflex excitation was delayed (39 ± 11 vs. 23 ± 7 ms, P < 0.001) and reflex excitation amplitude attenuated during mid-expiration versus early inspiration (209 ± 36 vs. 286 ± 80%, P = 0.009). These findings may provide insight into the physiological mechanisms of pharyngeal collapse in OSA.


Assuntos
Apneia Obstrutiva do Sono , Idoso , Eletromiografia , Feminino , Humanos , Pessoa de Meia-Idade , Músculos Faríngeos , Faringe , Polissonografia , Reflexo , Sono
4.
J Physiol ; 598(20): 4681-4692, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32864734

RESUMO

KEY POINTS: A decreased respiratory arousal threshold is one of the main contributors to obstructive sleep apnoea (OSA) pathogenesis. Several recent studies have sought to find a drug capable of increasing the respiratory arousal threshold without impairing pharyngeal muscle activity to reduce OSA severity, with variable success. Here we show that zolpidem increases the respiratory arousal threshold by ∼15%, an effect size which was insufficient to systematically decrease OSA severity as measured by the apnoea-hypopnoea index. Unlike recent physiological findings that showed paradoxical increases in pharyngeal muscle responsiveness during transient manipulations of airway pressure, zolpidem did not alter pharyngeal muscle responsiveness during natural sleep. It did, however, increase sleep efficiency without changing apnoea length, oxygen desaturation, next-day perceived sleepiness and alertness. These novel findings indicate that zolpidem was well tolerated and effective in promoting sleep in people with OSA, which may be therapeutically useful for people with OSA and comorbid insomnia. ABSTRACT: A recent physiology study performed using continuous positive airway pressure (CPAP) manipulations indicated that the hypnotic zolpidem increases the arousal threshold and genioglossus responsiveness in people with and without obstructive sleep apnoea (OSA). Thus, zolpidem may stabilise breathing and reduce OSA severity without CPAP. Accordingly, we sought to determine the effects of zolpidem on OSA severity, upper airway physiology and next-day sleepiness and alertness. Nineteen people with OSA with low-to-moderate arousal threshold received 10 mg zolpidem or placebo according to a double-blind, randomised, cross-over design. Participants completed two overnight in-laboratory polysomnographies (1-week washout), with an epiglottic catheter, intramuscular genioglossus electromyography, nasal mask and pneumotachograph to measure OSA severity, arousal threshold and upper airway muscle responsiveness. Next-morning sleepiness and alertness were also assessed. Zolpidem did not change the apnoea-hypopnoea index versus placebo (40.6 ± 12.3 vs. 40.3 ± 16.4 events/h (means ± SD), p = 0.938) or nadir oxyhaemoglobin saturation (79.6 ± 6.6 vs. 79.7 ± 7.4%, p = 0.932), but was well tolerated. Zolpidem increased sleep efficiency by 9 ± 14% (83 ± 11 vs. 73 ± 17%, p = 0.010). Arousal threshold increased by 15 ± 5% with zolpidem throughout all sleep stages (p = 0.010), whereas genioglossus muscle responsiveness did not change. Next-morning sleepiness and alertness were not different between nights. In summary, a single night of 10 mg zolpidem is well tolerated and does not cause next-day impairment in alertness or sleepiness, or overnight hypoxaemia in OSA. However, despite increases in arousal threshold without any change in pharyngeal muscle responsiveness, zolpidem does not alter OSA severity. It does, however, increase sleep efficiency by ∼10%, which may be beneficial in people with OSA and insomnia.


Assuntos
Nível de Alerta , Pressão Positiva Contínua nas Vias Aéreas , Humanos , Músculos Faríngeos , Sono , Zolpidem
5.
Eur Respir J ; 55(6)2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32165399

RESUMO

Accidental opioid-related deaths are increasing. These often occur during sleep. Opioids such as morphine may worsen obstructive sleep apnoea (OSA). Thus, people with OSA may be at greater risk of harm from morphine. Possible mechanisms include respiratory depression and reductions in drive to the pharyngeal muscles to increase upper airway collapsibility. However, the effects of morphine on the four key phenotypic causes of OSA (upper airway collapsibility (pharyngeal critical closure pressure; P crit), pharyngeal muscle responsiveness, respiratory arousal threshold and ventilatory control (loop gain) during sleep) are unknown.21 males with OSA (apnoea-hypopnoea index range 7-67 events·h-1) were studied on two nights (1-week washout) according to a double-blind, randomised, cross-over design (ACTRN12613000858796). Participants received 40 mg of MS-Contin on one visit and placebo on the other. Brief reductions in continuous positive airway pressure (CPAP) from the therapeutic level were delivered to induce airflow limitation during non-rapid eye movement (REM) sleep to quantify the four phenotypic traits. Carbon dioxide was delivered via nasal mask on therapeutic CPAP to quantify hypercapnic ventilatory responses during non-REM sleep.Compared to placebo, 40 mg of morphine did not change P crit (-0.1±2.4 versus -0.4±2.2 cmH2O, p=0.58), genioglossus muscle responsiveness (-2.2 (-0.87 to -5.4) versus -1.2 (-0.3 to -3.5) µV·cmH2O-1, p=0.22) or arousal threshold (-16.7±6.8 versus -15.4±6.0 cmH2O, p=0.41), but did reduce loop gain (-10.1±2.6 versus -4.4±2.1, p=0.04) and hypercapnic ventilatory responses (7.3±1.2 versus 6.1±1.5 L·min-1, p=0.006).Concordant with recent clinical findings, 40 mg of MS-Contin does not systematically impair airway collapsibility, pharyngeal muscle responsiveness or the arousal threshold in moderately severe OSA patients. However, consistent with blunted chemosensitivity, ventilatory control is altered.


Assuntos
Morfina , Apneia Obstrutiva do Sono , Pressão Positiva Contínua nas Vias Aéreas , Humanos , Masculino , Fenótipo , Sono
6.
J Sleep Res ; 28(6): e12853, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-30968498

RESUMO

New knowledge on hypnotics and their effects on the phenotypic causes of obstructive sleep apnea indicate that zolpidem has therapeutic potential for certain patients. Specifically, zolpidem increases the threshold for arousal threshold and pharyngeal dilator muscle responsiveness. However, the effects of a standard dose of zolpidem (10 mg) on obstructive sleep apnea severity and symptoms have not been investigated. In an open-label pilot study, 12 unselected people with obstructive sleep apnea were recruited following a diagnostic in-laboratory sleep study. Participants then returned for a single-night sleep study in which 10 mg of zolpidem was given just prior to sleep. Tolerability, next-day sleepiness and the effects of zolpidem on polysomnography variables were assessed. Zolpidem was well tolerated and significantly improved the sleep efficiency compared with the no-drug night (77 ±â€…12% versus 84 ±â€…9%, p = 0.005). Individual responses on obstructive sleep apnea severity to zolpidem in this unselected obstructive sleep apnea patient population were variable with no overall systematic difference in apnea-hypopnea index (29 ±â€…18.2 events per hr versus 33 ±â€…28 events per hr, p = 0.45) or other key respiratory parameters (e.g. event duration or hypoxemia). Next-day sleepiness assessed via the Karolinska Sleepiness Scale was not different between visits (4 ±â€…1 versus 4 ±â€…2, p = 0.85). These findings provide the first insight into the effects of a standard dose of zolpidem in obstructive sleep apnea, and highlight its tolerability and potential to improve sleep quality. The variable effects on obstructive sleep apnea severity observed in this pilot also underscore the need for larger trials that incorporate phenotypic characterisation (e.g. arousal threshold, Pcrit and muscle responsiveness) to understand inter-individual heterogeneity and the therapeutic potential of zolpidem for certain people with obstructive sleep apnea.


Assuntos
Medicamentos Indutores do Sono/uso terapêutico , Apneia Obstrutiva do Sono/tratamento farmacológico , Zolpidem/uso terapêutico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Medicamentos Indutores do Sono/farmacologia , Zolpidem/farmacologia
7.
J Sleep Res ; 28(5): e12773, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-30272379

RESUMO

Pharyngeal and oesophageal manometry is used clinically and in research to quantify respiratory effort, upper-airway mechanics and the pathophysiological contributors to obstructive sleep apnea. However, the effects of this equipment on respiratory events and sleep in obstructive sleep apnea are unclear. As part of a clinical trial (ANZCTRN12613001106729), data from 28 participants who successfully completed a physiology night with an epiglottic catheter and nasal mask followed by a standard in-laboratory polysomnography were compared. The apnea-hypopnea index was not different during the physiology night versus standard polysomnography (22 ±â€…14 versus 23 ±â€…13 events per hr, p = 0.71). Key sleep parameters were also not different compared between conditions, including sleep efficiency (79 ±â€…13 versus 81 ±â€…11%, p = 0.31) and the arousal index (26 ±â€…11 versus 27 ±â€…11 arousals per hr, p = 0.83). There were, however, sleep stage distribution changes between nights with less N3 and rapid eye movement sleep and more N1 on the physiology night, with no difference in N2 (53 ±â€…15 versus 48 ±â€…9, p = 0.08). However, these changes did not increase next-day sleepiness. These findings indicate that while minor sleep stage distribution changes do occur towards lighter sleep, epiglottic manometry does not alter obstructive sleep apnea severity or sleep efficiency. Thus, epiglottic manometry can be used clinically and to collect detailed physiological information for research without major sleep disruption.


Assuntos
Polissonografia/métodos , Apneia Obstrutiva do Sono/diagnóstico , Sono/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Apneia Obstrutiva do Sono/fisiopatologia
8.
J Physiol ; 596(14): 2853-2864, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29658103

RESUMO

KEY POINTS: Protective reflexes in the throat area (upper airway) are crucial for breathing. Impairment of these reflexes can cause breathing problems during sleep such as obstructive sleep apnoea (OSA). OSA is very common in people with spinal cord injury for unknown reasons. This study shows major changes in protective reflexes that serve to keep the upper airway open in response to suction pressures in people with tetraplegia and OSA. These results help us understand why OSA is so common in people with tetraplegia and provide new insight into how protective upper airway reflexes work more broadly. ABSTRACT: More than 60% of people with tetraplegia have obstructive sleep apnoea (OSA). However, the specific causes are unknown. Genioglossus, the largest upper-airway dilator muscle, is important in maintaining upper-airway patency. Impaired genioglossus muscle function following spinal cord injury may contribute to OSA. This study aimed to determine if genioglossus reflex responses to negative upper-airway pressure are altered in people with OSA and tetraplegia compared to non-neurologically impaired able-bodied individuals with OSA. Genioglossus reflex responses measured via intramuscular electrodes to ∼60 brief (250 ms) pulses of negative upper-airway pressure (∼-15 cmH2 O at the mask) were compared between 13 participants (2 females) with tetraplegia plus OSA and 9 able-bodied controls (2 females) matched for age and OSA severity. The initial short-latency excitatory reflex response was absent in 6/13 people with tetraplegia and 1/9 controls. Genioglossus reflex inhibition in the absence of excitation was observed in three people with tetraplegia and none of the controls. When the excitatory response was present, it was significantly delayed in the tetraplegia group compared to able-bodied controls: excitation onset latency (mean ± SD) was 32 ± 16 vs. 18 ± 9 ms, P = 0.045; peak excitation latency was 48 ± 17 vs. 33 ± 8 ms, P = 0.038. However, when present, amplitude of the excitation response was not different between groups, 195 ± 26 vs. 219 ± 98% at baseline, P = 0.55. There are major differences in genioglossus reflex morphology and timing in response to rapid changes in airway pressure in people with tetraplegia and OSA. Altered genioglossus function may contribute to the increased risk of OSA in people with tetraplegia. The precise mechanisms mediating these differences are unknown.


Assuntos
Músculos Faríngeos/fisiologia , Quadriplegia/fisiopatologia , Reflexo , Apneia Obstrutiva do Sono/fisiopatologia , Respiradores de Pressão Negativa , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
9.
Eur Respir J ; 52(1)2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29976648

RESUMO

Hypnotic use in obstructive sleep apnoea (OSA) is contraindicated due to safety concerns. Recent studies indicate that single-night hypnotic use worsens hypoxaemia in some and reduces OSA severity in others depending on differences in pathophysiology. However, longer clinical trial data are lacking. This study aimed to determine the effects of 1 month of zopiclone on OSA severity, sleepiness and alertness in patients with low-moderate respiratory arousal thresholds without major overnight hypoxaemia.69 participants completed a physiology screening night with an epiglottic catheter to quantify arousal threshold. 30 eligible patients (apnoea-hypopnoea index (AHI) 22±11 events·h-1) then completed standard in-laboratory polysomnography (baseline) and returned for two additional overnight sleep studies (nights 1 and 30) after receiving either nightly zopiclone (7.5 mg) or placebo during a 1-month, double-blind, randomised, parallel trial (ANZCTR identifier ANZCTRN12613001106729).The change in AHI from baseline to night 30 was not different between zopiclone versus placebo groups (-5.9±10.2 versus -2.4±5.5 events·h-1; p=0.24). Similarly, hypoxaemia, next-day sleepiness and driving simulator performance were not different.1 month of zopiclone does not worsen OSA severity, sleepiness or alertness in selected patients without major overnight hypoxaemia. As the first study to assess the effect of a hypnotic on OSA severity and sleepiness beyond single-night studies, these findings provide important safety data and insight into OSA pathophysiology.


Assuntos
Compostos Azabicíclicos/administração & dosagem , Hipnóticos e Sedativos/administração & dosagem , Piperazinas/administração & dosagem , Apneia Obstrutiva do Sono/tratamento farmacológico , Apneia Obstrutiva do Sono/fisiopatologia , Adulto , Nível de Alerta/efeitos dos fármacos , Compostos Azabicíclicos/efeitos adversos , Método Duplo-Cego , Esquema de Medicação , Feminino , Humanos , Hipnóticos e Sedativos/efeitos adversos , Masculino , Pessoa de Meia-Idade , Piperazinas/efeitos adversos , Polissonografia , Índice de Gravidade de Doença , Sono/efeitos dos fármacos , Resultado do Tratamento
10.
Eur Respir J ; 50(6)2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-29284686

RESUMO

Hypnotics are contraindicated in obstructive sleep apnoea (OSA) because of concerns of pharyngeal muscle relaxation and delayed arousal worsening hypoxaemia. However, human data are lacking. This study aimed to determine the effects of three common hypnotics on the respiratory arousal threshold, genioglossus muscle responsiveness and upper airway collapsibility during sleep.21 individuals with and without OSA (18-65 years) completed 84 detailed sleep studies after receiving temazepam (10 mg), zolpidem (10 mg), zopiclone (7.5 mg) and placebo on four occasions in a randomised, double-blind, placebo-controlled, crossover trial (ACTRN12612001004853).The arousal threshold increased with zolpidem and zopiclone versus placebo (mean±sd -18.3±10 and -19.1±9 versus -14.6±7 cmH2O; p=0.02 and p<0.001) but not with temazepam (-16.8±9 cmH2O; p=0.17). Genioglossus muscle activity during stable non-REM sleep and responsiveness during airway narrowing was not different with temazepam and zopiclone versus placebo but, paradoxically, zolpidem increased median muscle responsiveness three-fold during airway narrowing (median -0.15 (interquartile range -1.01 to -0.04) versus -0.05 (-0.29 to -0.03)% maximum EMG per cmH2O epiglottic pressure; p=0.03). The upper airway critical closing pressure did not change with any of the hypnotics.These doses of common hypnotics have differential effects on the respiratory arousal threshold but do not reduce upper airway muscle activity or alter airway collapsibility during sleep. Rather, muscle activity increases during airway narrowing with zolpidem.


Assuntos
Hipnóticos e Sedativos/efeitos adversos , Apneia Obstrutiva do Sono/induzido quimicamente , Apneia Obstrutiva do Sono/terapia , Sono/efeitos dos fármacos , Zolpidem/administração & dosagem , Adulto , Nível de Alerta/efeitos dos fármacos , Compostos Azabicíclicos/administração & dosagem , Compostos Azabicíclicos/efeitos adversos , Pressão Positiva Contínua nas Vias Aéreas , Estudos Cross-Over , Método Duplo-Cego , Feminino , Humanos , Hipnóticos e Sedativos/administração & dosagem , Masculino , Pessoa de Meia-Idade , Piperazinas/administração & dosagem , Piperazinas/efeitos adversos , Sistema Respiratório/efeitos dos fármacos , Temazepam/administração & dosagem , Temazepam/efeitos adversos , Língua/efeitos dos fármacos , Zolpidem/efeitos adversos
11.
Eur Respir J ; 43(4): 1149-58, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23766332

RESUMO

Sustained hypoxia is a dominant feature of respiratory disease. Despite the clinical significance, the effects of sustained hypoxia on the form and function of respiratory muscle during development are relatively underexplored. Wistar rats were exposed to 1 week of sustained hypoxia (ambient pressure 450 mmHg) or normoxia at various time points during development. Sternohyoid and diaphragm muscle contractile and endurance properties were assessed in vitro. Muscle succinate dehydrogenase and myosin heavy chain composition were determined. The role of reactive oxygen species in hypoxia-induced muscle remodelling was assessed. Sustained hypoxia increased sternohyoid muscle force and fatigue in early but not late development, effects that persisted after return to normoxia. Hypoxia-induced sternohyoid muscle fatigue was not attributable to fibre type transitions or to a decrease in oxidative capacity. Chronic supplementation with the superoxide scavenger tempol did not prevent hypoxia-induced sternohyoid muscle fatigue, suggesting that mechanisms unrelated to oxidative stress underpin hypoxia-induced maladaptation in sternohyoid muscle. Sustained hypoxia had no effect on diaphragm muscle fatigue. We conclude that there are critical windows during development for hypoxia-induced airway dilator muscle maladaptation. Sustained hypoxia-induced impairment of upper airway muscle endurance may persist into later life. Upper airway muscle dysfunction could have deleterious consequences for the control of pharyngeal airway calibre in vivo.


Assuntos
Diafragma/patologia , Regulação da Expressão Gênica no Desenvolvimento , Hipóxia , Músculo Esquelético/patologia , Animais , Feminino , Hematócrito , Imuno-Histoquímica , Masculino , Microscopia de Fluorescência , Contração Muscular/fisiologia , Fadiga Muscular/fisiologia , Cadeias Pesadas de Miosina/metabolismo , Ratos , Ratos Wistar , Espécies Reativas de Oxigênio/metabolismo , Músculos Respiratórios/fisiopatologia , Succinato Desidrogenase/metabolismo , Fatores de Tempo
12.
Ann Am Thorac Soc ; 20(4): 584-595, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36538809

RESUMO

Rationale: The combination of noradrenergic and antimuscarinic agents has recently been shown to improve upper-airway function and reduce obstructive sleep apnea (OSA) severity in short-term (⩽1 wk) proof-of-concept studies. Objectives: To determine the safety, tolerability, and potential efficacy of longer term use of different doses of the noradrenergic agent atomoxetine combined with the antimuscarinic oxybutynin (ato-oxy). Methods: Thirty-nine people with predominantly severe OSA received 80/5 mg ato-oxy, 40/5 mg ato-oxy, 40/2.5 mg ato-oxy, or placebo nightly for 30 days in a double-blind, randomized, parallel design. Participants completed three in-laboratory sleep studies (baseline, Night 1, and Night 30) to assess efficacy. Vital signs and objective measures of alertness and memory were assessed. In men, potential effects on prostate function were assessed using the International Prostate Symptom Score at baseline and Night 30. Potential adverse events were assessed during in-laboratory visits and via weekly phone calls. Results: Side effects were generally mild and consistent with known side-effect profiles of each individual drug (i.e., dose-dependent increases in dry mouth with oxybutynin). Heart rate increased by Night 30 in two active drug arms (mean ± standard deviation 8 ± 10 beats/min [P = 0.01] with 80/5 mg and 9 ± 14 beats/min [P = 0.02] with 40/2.5 mg vs. placebo). No clinically relevant changes in blood pressure, International Prostate Symptom Score, and measures of alertness and memory were observed between conditions. Apnea-hypopnea index (AHI) with 4% oxygen desaturation and hypoxic burden decreased by ∼50% with 80/5 mg ato-oxy from baseline but not versus placebo (e.g., AHI with 3% oxygen desaturation and AHI with 4% oxygen desaturation difference at Night 30 was -8.2 [95% confidence interval, -22.5 to 6.2] and -8.5 [95% confidence interval, -18.3 to 1.3] events/h, respectively). Conclusions: One month of nightly noradrenergic and antimuscarinic combination therapy was generally well tolerated, with a side-effect profile consistent with each agent alone, and was associated with an ∼50% reduction from baseline in a key OSA severity metric, the hypoxic burden with the highest dose combination. These findings highlight the potential to target noradrenergic and antimuscarinic mechanisms for OSA pharmacotherapy development. Clinical trial registered with www.anzctr.org.au (ACTRN 12619001153101).


Assuntos
Antagonistas Muscarínicos , Apneia Obstrutiva do Sono , Masculino , Humanos , Cloridrato de Atomoxetina/efeitos adversos , Antagonistas Muscarínicos/efeitos adversos , Apneia Obstrutiva do Sono/tratamento farmacológico , Oxigênio/uso terapêutico
13.
Sleep Med Rev ; 62: 101589, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35121222

RESUMO

Impaired upper airway sensation may contribute to obstructive sleep apnea (OSA) pathophysiology and could represent a therapeutic target. However, the extent of impaired sensation and its functional role in OSA pathogenesis remains unclear. This study aimed to: 1) evaluate methods of upper airway sensory testing in people with OSA, 2) compare upper airway sensation in people with and without OSA and 3) investigate the potential relationship between upper airway sensation and OSA severity. Major electronic databases were searched for studies that reported methods of upper airway sensory testing in people with OSA (n = 3819). From the selected studies (n = 38), information on the type of sensation, testing methods, validity and test-retest reliability were extracted. Meta-analyses were performed on case-controlled studies and studies that investigated potential relationships between upper airway sensation and OSA severity. Seven categories of sensory tests were reported: olfactory, gustatory, chemical, tactile, vibratory, thermal and perioral neuro-sensation. Testing methods varied widely across studies. No tests were validated in OSA. People with OSA had impaired upper airway sensation to airflow (p = 0.0002), chemical (p = 0.0001), gustatory (p = 0.009), olfactory (p = 0.04), tactile (p = 0.0001) and vibratory (p = 0.005) stimuli. Upper airway sensory impairment increased with OSA severity (p < 0.001). These findings suggest that, while variable across testing methods, people with OSA have impaired upper airway sensation, which is related to increased OSA severity. Development of valid and reliable upper airway sensory testing methods that relate to upper airway function in people with OSA are required to inform future clinical and research practices and identify potential therapeutic targets.


Assuntos
Apneia Obstrutiva do Sono , Estudos de Casos e Controles , Humanos , Reprodutibilidade dos Testes , Sensação , Apneia Obstrutiva do Sono/terapia
14.
J Appl Physiol (1985) ; 133(3): 755-765, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35771222

RESUMO

Tongue and upper airway dilator muscle movement patterns during quiet breathing vary in people with obstructive sleep apnea (OSA). Many patients have inadequate or counterproductive responses to inspiratory negative airway pressure that likely contributes to their OSA. This may be due, at least in part, to inadequate or nonhomogeneous reflex drive to different regions of the largest upper airway dilator, genioglossus. To investigate potential regional heterogeneity of genioglossus reflex responses in OSA, brief suction pulses were applied via a nasal breathing mask and an electromyogram (EMG) was recorded in four regions (anterior oblique, anterior horizontal, posterior oblique, and posterior horizontal) using intramuscular fine wire electrodes in 15 people with OSA. Genioglossus short-latency reflex excitation amplitude had regional heterogeneity (horizontal vs. oblique regions) when expressed in absolute units but homogeneity when normalized as a percentage of the immediate (100 ms) prestimulus EMG. Regional variability in reflex morphology (excitation and inhibition) was present in one-third of the participants. The minimum cross-sectional area (CSA) of the pharyngeal airway was quantified using MRI and may be related to the amplitude of the short-latency reflex response to negative pressure as we found that people with a smaller CSA tended to have a greater reflex amplitude (e.g., horizontal region r2 = 0.41, P = 0.01). These findings highlight the complexity of genioglossus reflex control, the potential for regional heterogeneity, and the functional importance of upper airway anatomy in mediating genioglossus reflex responses to rapid changes in negative pressure in OSA.NEW & NOTEWORTHY Our findings indicate that 30% of participants had regional heterogeneity in reflex morphology (excitation/inhibition) to brief pulses of negative upper-airway pressure across anterior oblique, anterior horizontal, posterior oblique, and posterior horizontal regions of the genioglossus muscle. Reflex excitation amplitude was proportional to prestimulus drive, with increased activation in oblique compared with horizontal regions of the posterior tongue. People with narrower upper-airway anatomy tended to have increased genioglossus reflex amplitude to negative pressure pulses during wakefulness.


Assuntos
Apneia Obstrutiva do Sono , Eletromiografia , Humanos , Reflexo/fisiologia , Língua/fisiologia , Vigília/fisiologia
15.
J Appl Physiol (1985) ; 132(3): 815-823, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-35050793

RESUMO

Obstructive sleep apnea (OSA) is common in people with multiple sclerosis (MS). However, people with MS often do not have "typical" anatomical risk factors (i.e., nonobese and female predominance). Accordingly, nonanatomical factors such as impaired upper-airway muscle function may be particularly important for OSA pathogenesis in MS. Therefore, this study aimed to investigate genioglossus (largest upper-airway dilator muscle) reflex responses to brief pulses of upper-airway negative pressure in people with OSA and MS. Eleven people with MS and OSA and 10 OSA controls without MS matched for age, sex, and OSA severity were fitted with a nasal mask, pneumotachograph, choanal and epiglottic pressure sensors, and intramuscular electrodes into genioglossus. Approximately 60 brief (250 ms) negative pressure pulses (approximately -12 cmH2O mask pressure) were delivered every 2-6 breaths at random during quiet nasal breathing during wakefulness to determine genioglossus electromyogram (EMGgg) reflex responses (timing, amplitude, and morphology). Where available, recent clinical MRI brain scans were evaluated for the number, size, and location of brainstem lesions in the group with MS. When present, genioglossus reflex excitation responses were similar between MS participants and controls (e.g., peak excitation amplitude = 229 ± 85% vs. 282 ± 98% baseline, P = 0.17). However, ∼30% of people with MS had either an abnormal (predominantly inhibition) or no protective excitation reflex. Participants with MS without a reflex had multiple brainstem lesions including in the hypoglossal motor nucleus which may impair sensory processing and/or efferent output. Impaired pharyngeal reflex function may be an important contributor to OSA pathogenesis for a proportion of people with MS.NEW & NOTEWORTHY This study investigated the function of an important reflex that helps protect the upper airway from closing during negative (suction) pressure in people with and without multiple sclerosis (MS) and obstructive sleep apnea (OSA). We found that ∼30% of people with MS had either no protective reflex or an abnormal reflex response. These findings indicate that impaired upper-airway reflex function may be an important contributor to OSA for a substantial proportion of people with MS.


Assuntos
Esclerose Múltipla , Apneia Obstrutiva do Sono , Eletromiografia , Feminino , Engasgo , Humanos , Masculino , Músculos Faríngeos/fisiologia , Reflexo/fisiologia , Sono/fisiologia , Vigília/fisiologia
16.
J Appl Physiol (1985) ; 130(5): 1373-1382, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33734828

RESUMO

The combination of the noradrenergic agent atomoxetine plus the antimuscarinic oxybutynin has recently been shown to improve upper airway physiology and reduce obstructive sleep apnea (OSA) severity. However, the effects of different antimuscarinics when combined with atomoxetine is limited. This study aimed to determine the effects of atomoxetine combined with two different antimuscarinics with varying M-subtype receptor selectivity on OSA severity and upper airway physiology. Ten people with predominantly severe OSA completed a double-blind, randomized, placebo-controlled, cross-over trial. Participants completed three overnight in-laboratory sleep studies after either 80 mg atomoxetine + 5 mg solifenacin succinate (ato-sol) or 80 mg atomoxetine + 2 mg biperiden hydrochloride (ato-bip) or placebo. OSA severity, ventilatory stability (loop gain), respiratory-arousal threshold (via epiglottic manometry), next-day subjective sleepiness [Karolinska Sleepiness Scale (KSS)], and alertness were compared between conditions. Neither drug combination altered the apnea/hypopnea index versus placebo (P = 0.63). Ato-sol caused a shift toward milder respiratory events with reduced frequency of obstructive apneas (13 ± 14 vs. 22 ± 17 events/h; means ± SD, P = 0.04) and increased hypopneas during nonrapid eye movement (NREM) (38 ± 21 vs. 24 ± 18 events/h, P = 0.006) with improved nadir oxygenation versus placebo (83 ± 4 vs. 80 ± 8%, P = 0.03). Both combinations reduced loop gain by ∼10% versus placebo; sleep efficiency and arousal threshold were unaltered. Ato-bip reduced next-day sleepiness versus placebo (KSS = 4.3 ± 2.2 vs. 5.6 ± 1.6, P = 0.03). Atomoxetine + biperiden hydrochloride reduces perceived sleepiness, and atomoxetine + solifenacin modestly improves upper airway function in people with OSA but to a lesser extent versus recently published atomoxetine + oxybutynin (broad M-subtype receptor selectivity) findings. These results provide novel mechanistic insight into the role of noradrenergic and antimuscarinic agents on sleep and breathing and are important for pharmacotherapy development for OSA.NEW & NOTEWORTHY In contrast to recent findings of major reductions in OSA severity when atomoxetine is combined with a nonspecific antimuscarinic, oxybutynin (broad M-subtype receptor selectivity), addition of solifenacin succinate (M2 and M3 muscarinic receptor selectivity) or biperiden (M1 muscarinic receptor selectivity) with atomoxetine had modest effects on upper airway function during sleep, which provide mechanistic insight into the role of noradrenergic and antimuscarinic agents on sleep and breathing and are important for pharmacotherapy development for OSA.


Assuntos
Antagonistas Muscarínicos , Apneia Obstrutiva do Sono , Cloridrato de Atomoxetina , Humanos , Polissonografia , Sono , Vigília
17.
Sleep Med Rev ; 60: 101519, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34229295

RESUMO

Insomnia and obstructive sleep apnea (OSA) commonly co-occur. Approximately 30-50% of patients with OSA report clinically significant insomnia symptoms, and 30-40% of patients with chronic insomnia fulfil diagnostic criteria for OSA. Compared to either insomnia or OSA alone, co-morbid insomnia and sleep apnea (COMISA) is associated with greater morbidity for patients, complex diagnostic decisions for clinicians, and reduced response to otherwise effective treatment approaches. Potential bi-directional causal relationships between the mechanisms and manifestations of insomnia and OSA could play an integral role in the development and management of COMISA. A greater understanding of these relationships is required to guide personalized diagnostic and treatment approaches for COMISA. This review summarizes the available evidence of bi-directional relationships between COMISA, including epidemiological research, case studies, single-arm treatment studies, randomized controlled treatment trials, and objective sleep study data. This evidence is integrated into a conceptual model of COMISA to help refine the understanding of potential bi-directional causal relationships between the two disorders. This theoretical framework is essential to help guide future research, improve diagnostic tools, determine novel therapeutic targets, and guide tailored sequenced and multi-faceted treatment approaches for this common, complex, and debilitating condition.


Assuntos
Síndromes da Apneia do Sono , Apneia Obstrutiva do Sono , Distúrbios do Início e da Manutenção do Sono , Pressão Positiva Contínua nas Vias Aéreas , Humanos , Polissonografia , Ensaios Clínicos Controlados Aleatórios como Assunto , Síndromes da Apneia do Sono/complicações , Síndromes da Apneia do Sono/epidemiologia , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/epidemiologia , Distúrbios do Início e da Manutenção do Sono/complicações , Distúrbios do Início e da Manutenção do Sono/epidemiologia
18.
Chest ; 158(1): 374-385, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32197956

RESUMO

BACKGROUND: Studies indicate that standard doses of hypnotics reduce or do not change the apnea-hypopnea index (AHI) or pharyngeal muscle activity. A 1-month trial of nightly zopiclone (7.5 mg) modestly reduced the AHI vs baseline without changing other sleep parameters or next-day sleepiness. RESEARCH QUESTION: This study aimed to determine the effects of high-dose zopiclone (15 mg) on AHI, arousal threshold, genioglossus muscle responsiveness, and next-day alertness in selected people with OSA (low to moderate arousal thresholds without major overnight hypoxemia). We hypothesized that high-dose zopiclone would yield greater increases in arousal threshold and therefore larger reductions in AHI but may come at the expense of increased hypoxemia and next-day impairment. STUDY DESIGN AND METHODS: Twenty-eight participants (AHI = 29 ± 20 events/h) suspected to have low to moderate arousal thresholds were studied during two in-laboratory polysomnographies, separated by 1 week, with an epiglottic pressure catheter and genioglossus intramuscular electrodes. Participants received 15 mg of zopiclone or placebo at each visit according to a double-blind, randomized, crossover design. Each morning, subjective sleepiness and alertness via a driving simulator task were assessed. RESULTS: The AHI did not change from placebo to zopiclone (-1.5 events/h; 95% CI, -6.6 to 3.5 events/h; P = .54). Arousal threshold, genioglossus muscle responsiveness, and most other sleep parameters and measures of next-day sleepiness and alertness also did not change with zopiclone. INTERPRETATION: A single night of treatment with high-dose zopiclone does not systematically reduce the AHI or increase the arousal threshold in selected people with OSA. The mechanisms for these unexpected findings require further investigation. TRIAL REGISTRY: Australian New Zealand Clinical Trials Registry; No.: ACTRN12617000988358; URL: https://www.anzctr.org.au.


Assuntos
Nível de Alerta/efeitos dos fármacos , Compostos Azabicíclicos/administração & dosagem , Hipnóticos e Sedativos/administração & dosagem , Piperazinas/administração & dosagem , Apneia Obstrutiva do Sono/tratamento farmacológico , Apneia Obstrutiva do Sono/fisiopatologia , Vigília/efeitos dos fármacos , Adulto , Estudos Cross-Over , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia
19.
J Appl Physiol (1985) ; 129(5): 1085-1091, 2020 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-32909921

RESUMO

Oral appliance (OA) therapy is the leading alternative to continuous positive airway pressure (CPAP) for obstructive sleep apnea (OSA). It is well tolerated compared with CPAP. However, ≥50% of patients using OA therapy have incomplete resolution of their OSA. Combination therapy with CPAP and oral appliance (CPAP + OA) is a potential alternative for incomplete responders to OA therapy. This study aimed to determine the extent to which combination therapy reduces therapeutic CPAP requirements using gold-standard physiological methodology in those who have an incomplete response to OA therapy alone. Sixteen incomplete responders [residual apnea/hypopnea index (AHI) > 10 events/h] to a novel OA with a built-in oral airway were recruited (3 women:13 men, aged 31-65 yr, body mass index: 22-38 kg/m2, residual AHI range: 13-63 events/h). Participants were fitted with a nasal mask, pneumotachograph, epiglottic pressure catheter, and standard polysomnography equipment. CPAP titrations were performed during non-rapid eye movement (NREM) supine sleep in each participant during three conditions (order randomized): CPAP only, CPAP + OA (oral airway open), and CPAP + OA (oral airway closed). OSA was resolved at pressures of 4 ± 2 and 5 ± 2 cmH2O during CPAP + OA (oral airway open) and CPAP + OA (oral airway closed) conditions versus 8 ± 2 cmH2O during CPAP only (P < 0.01). Negative epiglottic pressure swings in oral airway open and closed conditions were normalized to CPAP only levels [-2.5(-3.7, -2.6) vs. -2.3(-3.2, -2.4) vs. -2.1(-2.7, -2.3) cmH2O]. Combined CPAP and OA therapy reduces therapeutic CPAP requirements by 35%-45% and minimizes epiglottic pressure swings. This combination may be a therapeutic alternative for patients with incomplete responses to OA therapy alone and those who cannot tolerate high CPAP levels.NEW & NOTEWORTHY Combined CPAP and oral appliance therapy has been suggested as an alternative for incomplete responders to oral appliance therapy. We used a novel oral appliance incorporating an oral airway together with CPAP to show that pharyngeal pressure swings were normalized at reduced CPAP levels. Our findings demonstrate that using CPAP and oral appliance together may be a beneficial alternative for incomplete responders to oral appliance therapy and intolerant CPAP users due to high-pressure requirements.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Avanço Mandibular , Apneia Obstrutiva do Sono , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Faringe , Polissonografia , Apneia Obstrutiva do Sono/terapia
20.
J Clin Sleep Med ; 16(4): 483-492, 2020 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-32003735

RESUMO

STUDY OBJECTIVES: High nasal resistance is associated with oral appliance treatment failure in obstructive sleep apnea (OSA). A novel oral appliance with a built-in oral airway has been shown to reduce pharyngeal pressure swings during sleep and may be efficacious in those with high nasal resistance. The role of posture and mandibular advancement on nasal resistance in OSA remains unclear. This study aimed to determine (1) the effects of posture and mandibular advancement on nasal resistance in OSA and (2) the efficacy of a new oral appliance device including in patients with high nasal resistance. METHODS: A total of 39 people with OSA (7 females, apnea-hypopnea index (AHI) (mean ± standard deviation) = 29 ± 21 events/h) completed split-night polysomnography with and without oral appliance (order randomized). Prior to sleep, participants were instrumented with a nasal mask, pneumotachograph, and a choanal pressure catheter for gold standard nasal resistance quantification seated, supine and lateral (with and without oral appliance, order randomized). RESULTS: Awake nasal resistance increased from seated, to supine, to lateral posture (median [interquartile range] = 1.8 [1.4, 2.7], 2.7 [1.7, 3.5], 3.4 [1.9, 4.6] cm H2O/L/s, P < .001). Corresponding measures of nasal resistance did not change with mandibular advancement (2.3 [1.4, 3.5], 2.5 [1.8, 3.6], 3.5 [1.9, 4.8] cm H2O/L/s, P = .388). The median AHI reduced by 47% with oral appliance therapy (29 ± 21 versus 18 ± 15 events/h, P = .002). Participants with high nasal resistance (> 3 cm H2O/L/s) had similar reductions in AHI versus those with normal nasal resistance (61 [-8, 82] versus 40 [-5, 62] %, P = .244). CONCLUSIONS: Nasal resistance changes with posture in people with OSA. A novel oral appliance with a built-in oral airway reduces OSA severity in people with OSA, including in those with high nasal resistance. CLINICAL TRIAL REGISTRATION: Registry: ANZCTR; Title: Combination therapy for obstructive sleep apnoea; Identifier: ACTRN12617000492358; URL: https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=372279.


Assuntos
Avanço Mandibular , Apneia Obstrutiva do Sono , Pressão Positiva Contínua nas Vias Aéreas , Feminino , Humanos , Polissonografia , Postura , Apneia Obstrutiva do Sono/terapia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA