Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Orthop Sci ; 17(2): 141-7, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22258120

RESUMO

BACKGROUND: Experience treating proximal humerus fracture sequelae with reverse total shoulder arthroplasty is limited. We report our results. PATIENTS: Forty-four patients with sequelae of a proximal humeral fracture were treated with a reverse total shoulder prosthesis. There were 26 women and 18 men, with a mean age of 77 years (range, 74-84 years). The mean follow-up after reverse arthroplasty was 48 months (range, 40-84 months). RESULTS: The mean Constant score increased from 28 preoperatively to 58 postoperatively (p < 0.0001). The average anterior elevation increased from 40° to 100° (p < 0.0001), abduction from 41° to 95° (p < 0.0001), external rotation from 15° to 35° (p < 0.0001) and internal rotation from 25° to 60° (p < 0.0001). The average subjective shoulder score increased from 13% preoperatively to 56% postoperatively (p < 0.0001). All but six patients would undergo the same procedure again if faced with the same problem. Twenty-four patients were very satisfied, 14 satisfied and 6 unhappy with the operation. Six prosthetic dislocations occurred (13.6%). Two of them were successfully treated by adding an extension to the humeral neck component to increase the offset and tension. In the other four dislocations this procedure failed, and the prosthesis was revised and converted to a hemiarthroplasty. There was one case of glenoid component loosening that was converted to a hemiarthroplasty. CONCLUSIONS: The reverse total shoulder arthroplasty improves function and motion in patients with proximal humeral fracture sequelae. However, the dislocation rate is high.


Assuntos
Artroplastia de Substituição/métodos , Prótese Articular , Fraturas do Ombro/cirurgia , Articulação do Ombro/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Desenho de Prótese , Radiografia , Amplitude de Movimento Articular , Estudos Retrospectivos , Fraturas do Ombro/diagnóstico por imagem , Fraturas do Ombro/fisiopatologia , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
2.
Int Orthop ; 36(9): 1877-83, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22584619

RESUMO

PURPOSE: The purpose of this study was to compare arthroscopic rotator cuff repair with single-row and double-row techniques because research has demonstrated the superiority of double-row repair from a biological and mechanical point of view but there is no evidence of clinical superiority. METHODS: A total of 160 patients with a full-thickness rotator cuff tear underwent arthroscopic repair with suture anchors. They were randomised into two groups of 80 patients according to the repair technique: single-row (group 1) and double-row (group 2). Results were evaluated by use of the University of California, Los Angeles (UCLA), American Shoulder and Elbow Surgeons (ASES) and Constant questionnaires, the Shoulder Strength Index (SSI) and range of motion. Follow-up time was two years. Magnetic resonance imaging (MRI) studies were performed on each shoulder preoperatively and two years after repair. RESULTS: One hundred per cent of the patients were followed up. All measurements showed significant improvement compared with the preoperative status. The UCLA score showed significant improvement in group 2. In over 30-mm tears UCLA and ASES showed significant differences. SSI showed significant improvement in group 2. Range of motion showed significant improvements in flexion and abduction in group 2. In under 30-mm tears group 2 showed also significant improvement in internal and external rotation. In MRI studies there were no significant differences. CONCLUSIONS: At two years follow-up the double-row repair technique showed a significant difference in clinical outcome compared with single-row repair and this was even more significative in over 30-mm tears. No MRI differences were observed.


Assuntos
Artroscopia/métodos , Manguito Rotador/cirurgia , Ruptura/cirurgia , Articulação do Ombro/cirurgia , Tenodese/métodos , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Amplitude de Movimento Articular , Recuperação de Função Fisiológica , Manguito Rotador/fisiopatologia , Lesões do Manguito Rotador , Lesões do Ombro , Articulação do Ombro/fisiopatologia , Inquéritos e Questionários , Âncoras de Sutura , Traumatismos dos Tendões/fisiopatologia , Traumatismos dos Tendões/cirurgia , Resultado do Tratamento
3.
Injury ; 44(4): 488-91, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23195206

RESUMO

The purpose of this study is to report the long-term follow-up result of allograft reconstruction of segmental defect of the humeral head associated with posterior dislocation of the shoulder. Six men underwent operative management of defects of the humeral head involving 40% of the articular surface, following posterior dislocation of the humeral head. The period of time between dislocation and surgery ranged from 7 to 8 weeks. The defect in the head was filled with an allogeneic segment of humeral head contoured to restore the spherical shape. All the patients returned to their occupation 4 months later. All the cases were evaluated clinically and by radiographs and computed tomography (CT) scan at a mean of 122 (96-144) months after the operative procedure. Three men had no complaints of pain, instability, clicking or catching, whereas three had pain, clicking, catching and stiffness. The three patients with good clinical result showed also good radiographic result. The computed tomography (CT) confirmed incorporation of the allograft and no osteoarthrosis. Another patient had a good clinical and radiographic result until the eighth postoperative year. At 8-year follow-up examination, this patient developed shoulder osteoarthrosis and he had pain and stiffness. He needed an arthroplasty 10 years after the operation. The other two patients developed collapse of the graft and osteoarthrosis that were yet evident at 4-year follow-up. These patients required a shoulder arthroplasty 8 years after the procedure. We conclude that the treatment of segmental defects of the humeral head associated with posterior dislocations of the shoulder by allograft reconstruction has a good long-term follow-up result in 50% of the patients.


Assuntos
Artroplastia/métodos , Transplante Ósseo/métodos , Fixação Interna de Fraturas/métodos , Cabeça do Úmero/diagnóstico por imagem , Reoperação/estatística & dados numéricos , Luxação do Ombro/diagnóstico por imagem , Adulto , Artroplastia/efeitos adversos , Parafusos Ósseos , Transplante Ósseo/efeitos adversos , Transplante Ósseo/diagnóstico por imagem , Seguimentos , Fixação Interna de Fraturas/instrumentação , Humanos , Cabeça do Úmero/patologia , Cabeça do Úmero/cirurgia , Masculino , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/cirurgia , Amplitude de Movimento Articular , Recuperação de Função Fisiológica , Luxação do Ombro/epidemiologia , Luxação do Ombro/fisiopatologia , Luxação do Ombro/cirurgia , Dor de Ombro , Espanha/epidemiologia , Fatores de Tempo , Tomografia Computadorizada por Raios X , Transplante Homólogo , Resultado do Tratamento
4.
Adv Orthop ; 2013: 914148, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23533788

RESUMO

Purpose. The purpose of this study was to evaluate the functional outcome and the tendon healing after arthroscopic double row rotator cuff repair of large and massive rotator cuff tears. Methods. 82 patients with a full-thickness large and massive rotator cuff tear underwent arthroscopic repair with double row technique. Results were evaluated by use of the UCLA, ASES, and Constant questionnaires, the Shoulder Strength Index (SSI), and range of motion. Follow-up time was 2 years. Magnetic resonance imaging (MRI) studies were performed on each shoulder preoperatively and 2 years after repair. Results. 100% of the patients were followed up. UCLA, ASES, and Constant questionnaires showed significant improvement compared with preoperatively (P < 0.001). Range of motion and SSI in flexion, abduction, and internal and external rotation also showed significant improvement (P < 0.001). MRI studies showed 24 cases of tear after repair (29%). Only 8 cases were a full-thickness tear. Conclusions. At two years of followup, in large and massive rotator cuff tears, an arthroscopic double row rotator cuff repair technique produces an excellent functional outcome and structural integrity.

5.
Injury ; 43 Suppl 2: S3-6, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23622989

RESUMO

INTRODUCTION: Experience with treating proximal humeral nonunions with reverse total shoulder arthroplasty is limited. We report our results. PATIENTS: Eighteen patients with proximal humeral atrophic nonunion were treated with reverse total shoulder prosthesis. There were 12 women and 6 men, with a mean age of 78.8 years (range, 75-84 years). The mean follow up after reverse arthroplasty was 28 months (range, 24-32 months). Extensive proximal humeral bone loss that was found in six cases was treated adding a proximal humeral allograft. A long humeral stem was always used. RESULTS: The mean Constant score increased from 26% preoperatively to 55% postoperatively (p <0.0001). The average anterior elevation increased from 35° to 90° (p<0.0001), abduction from 35° to 85° (p<0.0001), external rotation from 15° to 30° (p <0.0001) and internal rotation from 25° to 55° (p <0.0001). The average subjective shoulder score increased from 10% preoperatively to 50% postoperatively (p <0.0001). All but 4 patients would undergo the same procedure again if faced with the same problem. Eight patients were very satisfied, 6 satisfied and 4 unhappy with the operation. We had one case of transitory axillary nerve palsy and two cases of infection. Two prosthetic dislocations occurred; they were successfully treated by revision with a larger polyethylene glenosphere of 44 mm. CONCLUSIONS: Reverse total shoulder arthroplasty improves function and motion in patients with proximal humeral fracture sequelae. However, the rate of dislocation is high.


Assuntos
Artroplastia de Substituição/métodos , Fraturas não Consolidadas/cirurgia , Luxação do Ombro/cirurgia , Fraturas do Ombro/cirurgia , Atividades Cotidianas , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Fraturas não Consolidadas/fisiopatologia , Fraturas não Consolidadas/reabilitação , Humanos , Incidência , Masculino , Osteoporose , Posicionamento do Paciente , Amplitude de Movimento Articular , Estudos Retrospectivos , Luxação do Ombro/fisiopatologia , Luxação do Ombro/reabilitação , Fraturas do Ombro/fisiopatologia , Fraturas do Ombro/reabilitação , Espanha/epidemiologia , Resultado do Tratamento
6.
Injury ; 2012 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-22222366

RESUMO

This article has been withdrawn at the request of the editor. The Publisher apologizes for any inconvenience this may cause. The full Elsevier Policy on Article Withdrawal can be found at http://www.elsevier.com/locate/withdrawalpolicy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA