Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Phys Rev Lett ; 132(22): 225001, 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38877942

RESUMO

We report on an experimental observation of the streaking of betatron x rays in a curved laser wakefield accelerator. The streaking of the betatron x rays was realized by launching a laser pulse into a plasma with a transverse density gradient. By controlling the plasma density and the density gradient, we realized the steering of the laser driver, electron beam, and betatron x rays simultaneously. Moreover, we observed an energy-angle correlation of the streaked betatron x rays and utilized it in diagnosing the electron acceleration process in a single-shot mode. Our work could also find applications in advanced control of laser beam and particle propagation. More importantly, the angular streaked betatron x ray has an intrinsic spatiotemporal correlation, which makes it a promising tool for single-shot pump-probe applications.

2.
Phys Rev Lett ; 130(10): 105002, 2023 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-36962018

RESUMO

The generation of low emittance electron beams from laser-driven wakefields is crucial for the development of compact x-ray sources. Here, we show new results for the injection and acceleration of quasimonoenergetic electron beams in low amplitude wakefields experimentally and using simulations. This is achieved by using two laser pulses decoupling the wakefield generation from the electron trapping via ionization injection. The injection duration, which affects the beam charge and energy spread, is found to be tunable by adjusting the relative pulse delay. By changing the polarization of the injector pulse, reducing the ionization volume, the electron spectra of the accelerated electron bunches are improved.

3.
Nat Commun ; 11(1): 6355, 2020 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-33311487

RESUMO

Laser wakefield accelerators promise to revolutionize many areas of accelerator science. However, one of the greatest challenges to their widespread adoption is the difficulty in control and optimization of the accelerator outputs due to coupling between input parameters and the dynamic evolution of the accelerating structure. Here, we use machine learning techniques to automate a 100 MeV-scale accelerator, which optimized its outputs by simultaneously varying up to six parameters including the spectral and spatial phase of the laser and the plasma density and length. Most notably, the model built by the algorithm enabled optimization of the laser evolution that might otherwise have been missed in single-variable scans. Subtle tuning of the laser pulse shape caused an 80% increase in electron beam charge, despite the pulse length changing by just 1%.

4.
Arch Intern Med ; 144(6): 1167-8, 1984 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-6732375

RESUMO

Elevated levels of serum gastrin as a consequence of gastric achlorhydria are characteristic of clinical pernicious anemia. In a largely male hospitalized population with an average age of 64 years, 7.7% had low levels of serum B12 (less than 170 pg/mL); only 2.5% of these had frank pernicious anemia. In an attempt to separate a subgroup with low levels of serum B12 in whom pernicious anemia may later develop, their serum gastrin levels were determined. Twenty-two percent had high values and, of these, 70% had low B12 absorptions. In patients with low serum B12 levels, serum gastrin assays may be useful in determining those in whom clinical pernicious anemia seems likely to develop.


Assuntos
Anemia Perniciosa/diagnóstico , Gastrinas/sangue , Deficiência de Vitamina B 12/diagnóstico , Vitamina B 12/sangue , Humanos , Masculino , Pessoa de Meia-Idade
5.
J Nucl Med ; 24(10): 949-51, 1983 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-6413663

RESUMO

The use of Co-57-labeled B12 for whole-body measurement of B12 uptake in humans has the advantage over Co-58 of easy commercial availability and lower cumulative radiation to the liver, but the disadvantage of significant attenuation. Methods devised to correct for the attenuation have used inaccurate early 100% counts. A method is described here that uses a liver phantom, containing a dissolved Co-57 B12 capsule, in a water tank. The ratios of upper to lower detector counts is related to total counts; it varies at different depths in the tank, and with the overall tank depth that is selected to accord with measured body habitus. The ratio of detector counts in the final patient count is used to read off the appropriate 100% total count. With this technique there is a clear discrimination between normal patients and those with pernicious anemia.


Assuntos
Boro/metabolismo , Radioisótopos de Cobalto/metabolismo , Radioisótopos/metabolismo , Contagem Corporal Total/métodos , Absorção , Anemia Perniciosa/metabolismo , Humanos , Fatores de Tempo
6.
J Nucl Med ; 26(8): 941-3, 1985 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-3928837

RESUMO

Previously described techniques for the measurement of the absorption of [57Co]vitamin B12 by total-body counting have required an iron room equipped with scanning or multiple detectors. The present study uses simplifying modifications which make the technique more available and include the use of static geometry, the measurement of body thickness to correct for attenuation, a simple formula to convert the capsule-in-air count to a 100% absorption count, and finally the use of an adequately shielded gamma camera obviating the need of an iron room.


Assuntos
Radioisótopos de Cobalto , Vitamina B 12/metabolismo , Absorção , Cápsulas , Equipamentos e Provisões , Humanos , Fígado/metabolismo , Masculino , Modelos Estruturais , Proteção Radiológica , Contagem Corporal Total
7.
Trans Am Clin Climatol Assoc ; 92: 227-33, 1981.
Artigo em Inglês | MEDLINE | ID: mdl-7281411

RESUMO

To summarize, from preliminary observations on the possible effects of radioactive fall-out, it may be inferred that in addition to the secondary products of ionizing irradiation per se, the stable end-products of the transmutation of certain radionuclides may adversely influence cellular metabolism, including mutagenesis. The discussion of the possible role of intracellular barium as an end-product of 137Cs decay is offered as an example of an unpredictable number of broad ecological, as well as the more limited medical, effects that may be of both clinical and climatological significance.


Assuntos
Flavonoides/farmacologia , Neoplasias Induzidas por Radiação , Lesões por Radiação , Cinza Radioativa , Replicação do DNA , DNA de Neoplasias , Humanos , Leucemia Induzida por Radiação , Mutagênicos/efeitos da radiação
8.
Health Phys ; 72(3): 351-60, 1997 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-9030836

RESUMO

A model to predict the time weighted exposures to gamma radiation was developed for buildings constructed with structural steel having some contamination from 60Co. Several buildings throughout sixteen city blocks in downtown Taipei were built about ten years ago with this material. These buildings were used for residential, business, and educational purposes with radiation levels ranging from background to five hundred times background. A comprehensive epidemiologic study by the National Yang Ming University Medical School in Taipei is underway to study the effects of this exposure to the building occupants. An evaluation of external radiation exposure was performed using survey instruments and thermoluminescent dosimeters. Exposure data from the survey instruments were used in a computer model developed to calculate cumulative radiation exposure estimates for the epidemiologic research. While the survey instrument data provided radiation levels at a point in time, the thermoluminescent dosimeters were placed in fixed locations and on several volunteers for a period of one month to verify the modeling results. The model itself is a mathematical algorithm that provides estimates with minimum and maximum range values by taking into account differences in the survey data between adults and children, variable occupancy patterns, background radiation, and radioactive decay. Several assumptions (background rates, height adjustment values, and occupancy factors) are easily adjusted to improve the estimated radiation exposures. The model predicted the exposures as measured by the thermoluminescent dosimeters with greater reliability for adults than for children. The differences between the two methods were about 10-15% for the adults and about 60% for the child. This strategy, its advantages, limitations, and its performance against actual thermoluminescent dosimeter measurements are presented.


Assuntos
Radioisótopos de Cobalto/análise , Exposição Ambiental , Habitação , Doses de Radiação , Poluentes Radioativos/análise , Atividades Cotidianas , Adulto , Criança , Humanos , Modelos Biológicos , Taiwan
18.
MMWR Suppl ; 55(2): 10-3, 2006 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-17183236

RESUMO

Engineering is the application of scientific and technical knowledge to solve human problems. Using imagination, judgment, and reasoning to apply science, technology, mathematics, and practical experience, engineers develop the design, production, and operation of useful objects or processes. During the 1940s, engineers dominated the ranks of CDC scientists. In fact, the first CDC director, Assistant Surgeon General Mark Hollis, was an engineer. CDC engineers were involved in malaria control through the elimination of standing water. Eventually the CDC mission expanded to include prevention and control of dengue, typhus, and other communicable diseases. The development of chlorination, water filtration, and sewage treatment were crucial to preventing waterborne illness. Beginning in the 1950s, CDC engineers began their work to improve public health while developing the fields of environmental health, industrial hygiene, and control of air pollution. Engineering disciplines represented at CDC today include biomedical, civil, chemical, electrical, industrial, mechanical, mining, and safety engineering. Most CDC engineers are located in the National Institute for Occupational Safety and Health (NIOSH) and the Agency for Toxic Substances and Disease Registry (ATSDR). Engineering research at CDC has a broad stakeholder base. With the cooperation of industry, labor, trade associations, and other stakeholders and partners, current work includes studies of air contaminants, mining, safety, physical agents, ergonomics, and environmental hazards. Engineering solutions remain a cornerstone of the traditional "hierarchy of controls" approach to reducing public health hazards.


Assuntos
Centers for Disease Control and Prevention, U.S./tendências , Engenharia/tendências , Saúde Pública/tendências , Centers for Disease Control and Prevention, U.S./história , Engenharia/história , História do Século XX , História do Século XXI , Humanos , Saúde Pública/história , Estados Unidos
19.
Am J Hematol ; 31(3): 194-8, 1989 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-2741912

RESUMO

The reported incidence of low serum vitamin B12 levels in patients ranges from 4% to 8%. In only a small percentage can this be ascribed to readily diagnosed pernicious anemia, malabsorption syndrome, or to gastrointestinal surgery. This leaves a number of patients in whom the meaning of the low serum B12 is not immediately apparent. In 71 patients with intact gastrointestinal tracts, hematological indices did not adequately separate patients with decreased absorption of unbound B12 from those with normal absorption. A low absorption of B12, either unbound or food-bound, was found, however, when the level of serum gastrin was elevated. In contrast, a normal absorption of unbound B12 was likely (95% of 44 patients) when the serum gastrin was normal.


Assuntos
Gastrinas/sangue , Deficiência de Vitamina B 12/diagnóstico , Absorção , Radioisótopos de Cobalto , Culinária , Gema de Ovo , Testes Hematológicos , Humanos , Vitamina B 12/administração & dosagem , Vitamina B 12/farmacocinética , Deficiência de Vitamina B 12/sangue
20.
Am J Phys Anthropol ; 58(3): 307-13, 1982 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-7124924

RESUMO

Ultrasound (A-scan mode) and skinfold methods were evaluated in the measurement of subcutaneous fat thickness and prediction of total fat weight (by whole body potassium counting). Based on intraobserver correlations on 39 men at 15 body sites, skinfold caliper measurements were more reproducible than ones obtained by ultrasound. Measurements made with the two techniques at the same site typically produced different mean estimates of fat thickness. However, scores were often highly correlated with each other, indicating similar relative rankings of subjects by each technique. Skinfolds were more highly correlated with total fat weight than were ultrasound measurements, but body weight. Anthropometric measurements were highly correlated with fatness because of their association with body weight, and when this relationship was statistically controlled for, they typically lost their predictive effectiveness. Multiple regression analyses revealed that the best predictors of fat weight were body weight along with skinfold and ultrasound measurements. These results suggest that skinfolds are a more effective means of assessing subcutaneous fat than ultrasound, especially when the large difference in cost of equipment is considered.


Assuntos
Tecido Adiposo/anatomia & histologia , Dobras Cutâneas , Ultrassonografia , Abdome , Braço , Peso Corporal , Humanos , Perna (Membro) , Masculino , Tórax
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA