RESUMO
OBJECTIVE: The aim of this double-blind, randomized clinical trial was to evaluate the 6- and 18-month clinical performances of a new universal adhesive applied in the "no-waiting" (NW) technique to non-carious cervical lesions (NCCLs) using two evaluation criteria. MATERIALS AND METHODS: One hundred and seventy-six restorations were assigned to four groups according to the adhesive system, adhesive strategy, and application mode: Prime&Bond Active (PB) applied using the etch-and-rinse (ER) and self-etch (SE) strategies with 20 s applications and Clearfil Universal Bond Quick (CQ) applied using the ER and SE strategies with the NW technique. The composite resin restorations were evaluated at baseline and after 6 and 18 months using the World Dental Federation (FDI) and US Public Health Service (USPHS) criteria. The Friedman repeated measures analysis of variance and Wilcoxon test were used for statistical analyses (α = 0.05). RESULTS: No significant differences were observed among any of the groups or criteria after 6 months (p > 0.05). After 18 months, 10 restorations were lost (p > 0.05) (2 with PB-ER [95.5%; 95%CI: 92-100%], 4 with PB-SE [90.9%; 95%CI: 82-98%], 0 with CQ-ER [100%; 95%CI: 92-100%], and 4 with CQ-SE [90.9%; 82-98%]). The restorations performed with the SE strategy showed more marginal discrepancies than those performed with the ER strategy, mainly when the FDI criteria were used (p < 0.05). Those that used the PB-SE showed fewer marginal discrepancies than those that used the CQ-SE (FDI; p < 0.05). A few restorations showed marginal discrepancies after the USPHS analysis (p > 0.05). CONCLUSIONS: The results when using the CQ-SE and -ER strategies with the NW technique were similar to those when using the PB-SE and -ER strategies in standard applications to non-carious cervical lesions after 6 and 18 months of clinical evaluation. CLINICAL RELEVANCE: After 6 and 18 months, the application of Clearfil Universal Bond Quick with the "no-waiting" technique showed similar clinical performance compared to the standard application of Prime & Bond Active applied using the standard application time (20 s). TRIAL REGISTRATION: ClinicalTrials.gov identifier RBR-5f9gps.
Assuntos
Cimentos Dentários , Adesivos Dentinários , Humanos , Adesivos Dentinários/química , Cimentos de Resina/química , Restauração Dentária Permanente/métodos , Método Duplo-Cego , Falha de Restauração Dentária , Resinas Compostas/uso terapêutico , Resinas Compostas/química , Adaptação Marginal DentáriaRESUMO
OBJECTIVES: This study investigated the ability of modified phosphoric acids containing chlorhexidine (CHX) or grape seed extract (GSE) for promoting simultaneous biomodification during acid etching on bonding properties in caries-affected dentin (CAD). MATERIALS AND METHODS: Thirty-two human molars (8 with sound dentin [SD] and 24 naturally CAD) were selected for the study. The SD and CAD were initially exposed, then randomized and etched according to the following groups: (1) SD (SD-CT) and CAD (CAD-CT) both with 37% phosphoric acid, (2) CAD with 2% CHX containing 37% phosphoric acid (CAD-CHX), and (3) CAD with 2% GSE containing 10% phosphoric acid (CAD-GSE). The bonding procedure and composite build-ups were performed after acid etching. Subsequently, they were sectioned in resin-dentin specimens. The specimens were submitted for chemical profiling by micro-Raman, microtensile bond strength (µTBS), failure mode with chemical characterization by FEG/SEM-EDX, and in situ zymography by CLSM. The data from µTBS and CLSM were statistically analyzed (1-way ANOVA and Tukey's test; α = 0.05). RESULTS: The highest µTBS results were shown for SD-CT in comparison with all CAD groups (p < 0.001), and the lowest for CAD-CT and CAD-CHX (p < 0.001). The etching with CHX did not increase the µTBS for CAD when compared with CT (p = 0.52). However, the etching with GSE improved significantly the µTBS for CAD when compared with CT and CHX (p < 0.001). The chemical profile detected chemical and structural changes in collagen peaks for CAD-CT, which were not detected when the CAD was etched by modified acids. Also, the poorest hybridization ability was detected in CAD for CT, which was significantly improved with modified acids, especially the GSE, as evaluated by chemical profile and failure mode. A significant reduction of MMP activity on CAD was promoted by modified acids in comparison with CT (both p < 0.001). CONCLUSIONS: The GSE-containing acid was able to promote biomodification during the acid etching, increasing the bonding properties and reducing the activity of the MMPs within the hybrid layer. CLINICAL RELEVANCE: The use of GSE-containing phosphoric acid can be a promising alternative to improve the bonding performance on caries-affected dentin, since it is capable of biomodifying the dentin during the acid etching, without adding any extra step in bonding procedures.
Assuntos
Colagem Dentária , Adesivos Dentinários , Resinas Compostas , Suscetibilidade à Cárie Dentária , Dentina , Humanos , Teste de Materiais , Cimentos de Resina , Propriedades de Superfície , Resistência à TraçãoRESUMO
OBJECTIVES: The aim of this study was to investigate the effects of collagen cross-linking agents on nanomechanical and bonding properties of eroded dentin (ED), 24 h and 2 years after water storage. MATERIALS AND METHODS: Human molar dentin surfaces, eroded by soft drinks or citric acid, were acid-etched and treated with primers containing proanthocyanidin (PA) and riboflavin (RI) or were untreated (control) and tested after 24 h and 2 years. After acid etching and adhesive application (Prime&Bond Elect (PBE); Scotchbond Universal (SBU); Tetric n-bond Universal (TEU)), specimens were sectioned into beams and tested for microtensile bond strength (µTBS) and silver nitrate deposition (NL) after 24 h and 2 years. The beams were used to evaluate the 24-h in situ conversion of degree (DC). Nanohardness (NH) and Young's modulus (YM) were evaluated via resin-bonded dentin slices after 24 h and 2 years. A three-way ANOVA and Tukey's test were used for statistical analysis (5%). RESULTS: For both storage times, ED with citric acid resulted in lower µTBS, NH, and YM and higher NL for each adhesive system than soft drink ED (p < 0.05). After 2 years of water storage, cross-linking primers maintained the µTBS, NH, and YM (p < 0.05) when compared with the control group. Althougth, the NL values decreased for all groups after 2 years of water storage, PA and RI treatments showed NI values lower than control group (p < 0.001). No significant differences were observed between PA and RI treatments (p > 0.05). Cross-linking primers maintain or improve DC (p < 0.03). In general, TEU and SBU yielded higher µTBS, DC, NH, and YM and lower NL than PBE. CONCLUSION: Cross-linking agents improved the results and maintained the resin-ED interface bonding and nanomechanical properties, without jeopardizing adhesive polymerization. CLINICAL RELEVANCE: Cross-linking agents are a viable alternative for improving and maintaining resin-ED interface bonding and nanomechanical properties.
Assuntos
Colagem Dentária , Colágeno , Resinas Compostas , Dentina , Adesivos Dentinários , Humanos , Teste de Materiais , Cimentos de Resina , Resistência à Tração , ÁguaRESUMO
OBJECTIVES: A systematic review and meta-analysis were performed to answer this research question: "Does combined in-office (IO) and at-home (AH) bleaching produce improved color change and lower tooth sensitivity (TS) better than solely AH or IO bleaching in adults?" MATERIAL AND METHODS: Randomized controlled trials in adults that compared combined versus sole application bleaching were included. The risk of bias (RoB) was evaluated using the Cochrane Collaboration tool. Meta-analyses were conducted for color change in shade guide units (∆SGU) and with a spectrophotometer (∆E*), risk, and intensity of TS, using the random effects model. Heterogeneity was assessed with Cochran's Q test and I2 statistics. GRADE assessed the quality of the evidence. PubMed, Scopus, Web of Science, LILACS, BBO, Cochrane Library, SIGLE, IADR abstracts, unpublished, ongoing trial registries, dissertations, and theses were searched on August 28, 2017 (updated on January 29, 2019). RESULTS: Twelve studies remained. Two were considered to have low RoB. For combined vs. IO bleaching, no significant difference for ∆E*, ∆SGU, and risk of TS were observed; data were not available to analyze the intensity of TS. For combined vs. AH bleaching, no significant difference for ∆E*, ∆SGU, but lower TS to risk (RR 1.40, 95% 1.10 to 1.80) and intensity (MD 1.40, 95% CI 0.18 to 2.63) were detected for AH bleaching. Quality of evidence was graded as low or very low in all meta-analyses. CONCLUSION: Lower risk and intensity of TS was observed for the solely AH group without jeopardizing color change. However, more studies are still encouraged due to the low quality of evidence for most of the outcomes. CLINICAL RELEVANCE: If clinicians are to choose between combined or sole AH bleaching, the solely AH may be preferable; combined bleaching may potentiate the risk of TS without benefits in color change. For combined or sole IO bleaching, no important clinical difference in color change and risk of TS were detected; however, intensity of TS could not be compared due to lack of data. Further studies should be conducted due to the low/very low quality of the evidence.
Assuntos
Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Dente , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto JovemRESUMO
PURPOSE: To investigate the antibacterial effects of Terminalia catappa Linn (TCL) leaf extracts at different concentrations and the effects of these extracts used as primers on the long-term adhesive properties of two universal adhesives. MATERIALS AND METHODS: After extract preparation, the antimicrobial and antibacterial activities of TCL against Streptococcus mutans (UA 159) were assessed in microdilution assays to provide the minimal inhibitory concentration (MIC) and minimal bactericidal concentration (MBC). Additionally, to provide quantitative data on the ability of TCL extract to reduce cell viability, colony forming units (CFU) were counted. To examine adhesive properties, 288 human molars were randomly assigned to 32 experimental conditions (n = 9) according to the following variables: (1) treatment agent: negative control (untreated surface), and primers at concentrations of 1xMIC, 5xMIC, and 10xMIC; (2) adhesives: Scotchbond Universal (SBU) and Futurabond Universal (FBU); (3) adhesive strategy: etch-and-rinse (ER) or self-etch (SE); and (4) storage time: 24 h or after 2 years. Primers were applied for 60 s, upon which the teeth were incrementally restored and sectioned into adhesive-dentin bonded sticks. These were tested for microtensile bond strength (µTBS) and nanoleakage (NL) after 24-h and 2-year water storage, as well as in-situ degree of conversion (DC) at 24 h. The chemical profile of the hybrid layer was determined via micro-Raman spectroscopy. Biofilm assay data were analyzed using the Kruskal-Wallis test; the pH of culture media and the chemical profile were analyzed by one-way ANOVA. The adhesive properties (µTBS, NL, DC) were evaluated using a four-way ANOVA and Tukey's test. Significance was set at 5%. RESULTS: Similar values of MIC and MBC were observed (2 mg/ml), showing bactericidal potential. CFU analysis demonstrated that concentrations of 5xMIC and 10xMIC significantly inhibited biofilm formation (p < 0.001). The application of the TCL primer at all concentrations significantly increased the immediate µTBS and DC, and decreased the immediate NL values when compared to the control group (p < 0.05), regardless of the adhesive and adhesive strategies. Despite an increase in the NL values for all groups after 2 years (p > 0.05), in groups where the TCL primer was applied, the µTBS remained constant after 2 years for both adhesives, while a decrease in the µTBS was observed in the control groups (p < 0.05). Usually, 10xMIC showed better results than 1xMIC and 5xMIC (p < 0.05). The application of TCL promoted cross-linking; cross-linking rates increased proportionally to the concentration of TCL (p < 0.05). CONCLUSION: Primers containing TCL promoted bactericidal and bacteriostatic action, as well as cross-linking with dentin, while maintaining the adhesive properties of the adhesive-dentin interface after 2 years of water storage.
Assuntos
Colagem Dentária , Terminalia , Humanos , Cimentos Dentários/farmacologia , Cimentos Dentários/química , Adesivos Dentinários/farmacologia , Adesivos Dentinários/química , Resinas Compostas/química , Dentina , Resistência à Tração , Cimentos de Resina/farmacologia , Cimentos de Resina/química , Água/química , Antibacterianos/farmacologia , Teste de MateriaisRESUMO
Staphylococcus aureus is a pathogen widely involved in wound infection due to its ability to release several virulence factors that impair the skin healing process, as well as its mechanism of drug resistance. Herein, sodium alginate and chitosan were combined to produce a hydrogel for topical delivery of neomycin to combat S. aureus associated with skin complications. The hydrogel was formulated by combining sodium alginate (50 mg/mL) and chitosan (50 mg/mL) solutions in a ratio of 9:1 (HBase). Neomycin was added to HBase to achieve a concentration of 0.4 mg/mL (HNeo). The incorporation of neomycin into the product was confirmed by scanning electron microscopy, FTIR and TGA analysis. The hydrogels produced are homogeneous, have a high swelling capacity, and show biocompatibility using erythrocytes and fibroblasts as models. The formulations showed physicochemical and pharmacological stability for 60 days at 4 ± 2 °C. HNeo totally inhibited the growth of S. aureus after 4 h. The antimicrobial effects were confirmed using ex vivo (porcine skin) and in vivo (murine) wound infection models. Furthermore, the HNeo-treated mice showed lower severity scores than those treated with HBase. Taken together, the obtained results present a new low-cost bioproduct with promising applications in treating infected wounds.
Assuntos
Alginatos , Antibacterianos , Quitosana , Hidrogéis , Neomicina , Staphylococcus aureus , Quitosana/química , Quitosana/farmacologia , Alginatos/química , Alginatos/farmacologia , Hidrogéis/química , Hidrogéis/farmacologia , Staphylococcus aureus/efeitos dos fármacos , Animais , Camundongos , Neomicina/farmacologia , Neomicina/química , Neomicina/administração & dosagem , Antibacterianos/farmacologia , Antibacterianos/química , Infecções Estafilocócicas/tratamento farmacológico , Infecções Cutâneas Estafilocócicas/tratamento farmacológico , Infecções Cutâneas Estafilocócicas/microbiologia , Infecções Cutâneas Estafilocócicas/patologia , Portadores de Fármacos/química , Pele/efeitos dos fármacos , Pele/microbiologiaRESUMO
This study aimed to assess the potential association between perception malocclusion and school performance in children and adolescents. An electronic search was performed in ten databases. Based on the PECO acronym (Population, Exposition, Comparator, and Outcome), the eligibility criteria included observational studies that compared the school performance of children and adolescents with and without the perception of malocclusion. There were no restrictions on the language or year of publication. Two reviewers selected the studies, extracted the data, and assessed the risk of bias by using the Joanna Briggs Institute tool for cross-sectional studies. School performance was measured by analyzing student grades; levels of absenteeism; and child or adolescent self-perception and/or the perception of parents, guardians, close friends, and teachers regarding the impact of malocclusion on school performance. The data were described narratively/descriptively. The search resulted in 3,581 registers, of which eight were included in the qualitative synthesis. These studies were published between 2007 and 2021. Two studies concluded that there was no significant association between school performance and perception of malocclusion, five studies found that only some of the children with malocclusion had their school performance affected, and one study concluded that there was a significant association between perception of malocclusion and low school performance. Considering all variables and the very low certainty of evidence, the perception of malocclusion seems to negatively impact school performance when associated with external and subjective factors. Further studies using additional measurement standards are required.
Assuntos
Má Oclusão , Criança , Humanos , Adolescente , Estudos Transversais , Estudantes , Pais , PercepçãoRESUMO
OBJECTIVES: To evaluate the microtensile bond strength (µTBS) and nanoleakage (NL) of several universal adhesives to eroded dentine (ED) using etch-and-rinse (ER) and self-etch (SE) strategies, immediately and after 6 years of water storage. MATERIAL AND METHODS: Four hundred and eighty human molars were distributed into 60 groups according to dentine substrate (sound dentine [SD], eroded with soft drink, or eroded with citric acid), application method of the adhesive (SE or ER), and the adhesives used: 1. All-Bond Universal, 2. Ambar Universal, 3. Clearfil Universal, 4. Futurabond U, 5. One Coat 7 Universal, 6. Peak Universal Bond, 7. Prime&Bond Elect, 8. Scotchbond Universal, 9. Tetric n-bond Universal, and 10. Xeno Select. The restoration was then performed with a composite resin, and the specimens were sectioned into resin-dentine bonded sticks. The sticks were tested (immediately or after 6 years of storage) for µTBS (0.5 mm/min) or used to assess NL. The eroded dentine surfaces were also examined using FE-SEM to evaluate the NL. Data for µTBS were analyzed by four-way ANOVA and Tukey's post-hoc test (a = 0.05), and the NL was analyzed by Kruskal-Wallis and the Wilcoxon Signed Rank Sum test (a = 0.05). RESULTS: In ED, there was no difference in µTBS and NL between ER and SE strategies (p > 0.05). Most µTBS and NL values obtained for ED were lower and higher, respectively, than those for SD (p < 0.005). Additionally, the worst results (µTBS and NL) were observed for erosion with citric acid groups in comparison with erosion with soft-drink groups (p < 0.007). After 6y, µTBS was generally lower and NL higher for all substrates, adhesives, and strategies (p < 0.05), except for AMB, SBU, and TEU in dentine eroded with citric acid. The lowest µTBS and highest NL values were observed for ABU, FBU, OCU, PUB, PBE, and XEN in both types of eroded dentine and evaluation times (p < 0.002). CONCLUSION: The use of MDP-containing adhesives seems to be essential to maintain adhesion to eroded dentine. However, other factors such as acidity should be considered. CLINICAL SIGNIFICANCE: The bonding of eroded dentine is a challenge. However, the use of MDP-containing universal adhesives showed less degradation after long-term evaluation.
Assuntos
Colagem Dentária , Cimentos Dentários , Humanos , Adesivos Dentinários/química , Colagem Dentária/métodos , Cimentos de Resina/química , Água/química , Dentina , Resistência à Tração , Teste de Materiais , AdesivosRESUMO
OBJECTIVE: To evaluate the effect of dimethyl sulfoxide (DMSO) on the microtensile bond strength (µTBS) and nanoleakage (NL) of universal adhesives on eroded dentine, immediately and after four years of water storage. METHODS: Sixty-four sound human molars were distributed into 16 groups according to (1) Dentine surface (sound and eroded dentine); (2) dimethyl sulfoxide application (with or without); (3) Application mode (etch-and-rinse or self-etch) and (4) Storage time (immediate and four years). One mild universal adhesive was used (Scotchbond Universal). The restoration was then performed with a composite resin and the specimens were sectioned into resin-dentine bonded sticks. Resin-dentine bonded sticks were tested (immediately and after four years of water storage) for µTBS (0.5 mm/min) or used to assess NL. Data on µTBS and NL were analyzed using four-way ANOVA and Tukey's test (α = 0.05). RESULTS: Only the 3-way cross-product interaction 'substrate vs DMSO vs time' was statistically significant (p = 0.007). Eroded dentine showed a lower mean of µTBS and a higher mean of NL values than sound dentine. However, when DMSO was applied, no significant decrease of µTBS or NL values was observed after four years of water storage, regardless of adhesive strategies, or dentine evaluated, when compared to immediate results. SIGNIFICANCE: Water-based DMSO pre-treatments not only prevent degradation of MDP-containing simplified adhesives but also serve as a potential alternative to improve long-term bonding properties to eroded dentine. The versatility of using a single pre-treatment for both self-etch or etch-and-rinse bonding to eroded dentin may facilitate future clinical applications.
Assuntos
Colagem Dentária , Dimetil Sulfóxido , Humanos , Cimentos Dentários , Colagem Dentária/métodos , Adesivos Dentinários/química , Condicionamento Ácido do Dente/métodos , Cimentos de Resina/química , Dentina , Água/química , Resistência à Tração , Teste de MateriaisRESUMO
This in vitro study aimed to evaluate the effect of different bonding strategies on the micro-shear bond strength (µSBS) of luting agents to CAD−CAM composites. Surface scanning electron microscopy (SEM) and spectroscopy by energy-dispersive X-ray spectroscopy (EDS) were performed to analyze the surfaces of the composite before and after bonding treatment. Three CAD−CAM composites were evaluated: Lava Ultimate restorative (LU), Brava Blocks (BR), and Vita Enamic (VE). The LU and BR surfaces were sandblasted using aluminum oxide, while the VE surfaces were etched using a 5% hydrofluoric acid gel according to the manufacturers' recommendations. All surfaces were subjected to the following bonding strategies (n = 15): adhesive with silane and MDP (ScotchBond Universal, 3M Oral Care, St Paul, MI, USA); adhesive with MDP (Ambar Universal, FGM, Joinville, Brazil); adhesive without silane or MDP (Prime&Bond Elect, Dentsply Sirona, Charlotte, NC, USA), pure silane without MDP (Angelus, Londrina, Brazil), and pure silane with MDP (Monobond N, Ivoclar Vivadent, Schaan, Liechtenstei). Afterwards, tygons were filled with RelyX Ultimate (3M Oral Care), AllCem (FGM), or Enforce (Dentsply Sirona), which were light-cured and subjected to the µSBS test. Data were analyzed using two-way ANOVA and Bonferroni's post hoc test (α = 0.05). Additional blocks (n = 15) were subjected to scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS) before and after the surface treatment. The µSBS values on VE surfaces were higher than those observed on LU and BR surfaces (p < 0.001). Silane without MDP (Allcem) promoted the highest µSBS values, while silane with MDP (RelyX Ultimate) provided the highest values among all bonding strategies (p < 0.001). Enforce promoted no significant difference in µSBS values. SEM and EDS analyses detected noticeable changes to the surface morphology and composition after the surface treatment. The effectiveness of the bonding strategy may vary according not only to the CAD−CAM composite but also to resin cement/bonding agent/silane used.
RESUMO
PURPOSE: To evaluate the microtensile bond strength (µTBS) and silver nitrate uptake (SNU) of three universal adhesives used in etch-and-rinse (ER) and self-etch (SE) modes on dry, wet, and oversaturated dentin surfaces after 24 h and 1 year of water storage. The morphology of the hybrid layer (MHL) and the degree of conversion (DC) were also evaluated. MATERIALS AND METHODS: Human molars were divided into 36 groups according to combinations of the following variables: (i) universal adhesives (Ambar Universal APS [AMB], Prime&Bond Active [PBA], Scotchbond Universal Adhesive [SBU]), (ii) adhesive strategies (ER or SE), (iii) moisture level (dry, wet, or oversaturated dentin surface), and (iv) storage time (24 h or 1 year). After restoration, the specimens were sectioned into resin-dentin sticks and tested for µTBS and SNU according to storage time. For MHL, the specimens were sectioned and evaluated after 24 h using SEM. DC was evaluated using FTIR. ANOVA and Tukey's test were used for statistical analyses (5%). RESULTS: When 24-h vs 1-year data were compared, there was a significant decrease in µTBS and an increase in SNU values for the majority of experimental groups (p < 0.0001). On dry (ER) and oversaturated (ER and SE) dentin, AMB showed higher µTBS than did PBA (p < 0.00001). No significant decrease in µTBS was observed when universal adhesives were applied in the SE mode to dry dentin (p > 0.05). Regarding SNU, at all moisture levels, AMB showed lower SNU values than SBU (p < 0.001). Regarding MHL, SBU showed several imperfections when applied to oversaturated dentin in comparison with AMB and PBA. Regarding DC, when dentin was kept dry or was oversaturated, AMB showed a higher DC than PBA (p < 0.0001). CONCLUSION: The behavior of the different universal adhesives evaluated did not vary when applied to wet or dry dentin. However, the results with oversaturated dentin were dependent on the universal adhesive. Independent of the moisture level and the universal adhesive evaluated, significant degradation of the bonding properties occurred after 1 year of water storage, with the exception of universal adhesives applied to dry dentin in the SE strategy.
Assuntos
Colagem Dentária , Infiltração Dentária , Humanos , Adesivos Dentinários/química , Resinas Compostas/química , Cimentos Dentários/química , Dentina , Resistência à Tração , Teste de Materiais , Cimentos de Resina/química , Água/química , AdesivosRESUMO
This paper evaluates the effect of an additional hydrophobic resin coat (extra HL) associated with universal adhesives on sound and eroded dentin and evaluated immediately or after 2 years of water storage to improve the microtensile bond strength (µTBS) and nanoleakage (NL) when compared to the use of universal adhesives only. Sixty-four molars were assigned to eight groups using the following combinations: 1. dentin substrate, including sound and eroded dentin; 2. treatment, including the control and extra HL and storage time (immediately and after two-years of storage). Two universal adhesives (Prime & Bond Active or Scotchbond Universal) were evaluated. Before restoration, half of the teeth were subjected to soft-drink erosion. Composite buildups were bonded; specimens were stored (37 °C/24 h), sectioned into resin−dentin bonded sticks and tested for microtensile bond strength and nanoleakage using SEM (immediately and after two-years of storage). Three-way ANOVA and Tukey's test (α = 0.05%) were used. In the immediate testing, the application of extra HL did not increase microtensile bond strength values compared with the control group in either substrate (p > 0.05). However, extra HL significantly decreased nanoleakage values when applied to eroded and sound dentin (p = 0.0001). After two years, the application of extra HL produced significantly higher microtensile bond strength and lower nanoleakage values than the control group for both adhesives (p = 0.0001). In all cases, sound dentin showed higher microtensile bond strength and lower nanoleakage values than eroded dentin (p = 0.000001). An extra HL increased the bond strength and reduced nanoleakage in eroded dentin after two-years of storage.
RESUMO
PURPOSE: To compare the effect of active pre-conditioning with 17% ethylenediaminetetraacetic acid (EDTA) vs 37% phosphoric acid (PA) on the resin-enamel microshear bond strength (µSBS), enamel-etching pattern, and in situ degree of conversion (in situ DC) of four universal adhesives on sound and fluorotic enamel. MATERIAL AND METHODS: In this study, 448 extracted human molars (224 without fluorosis and 224 with fluorosis) were sectioned into four parts and divided into 16 experimental groups based on the enamel surface (sound or fluorotic enamel), adhesive (Clearfil Universal Bond [CUB], Futurabond U [FBU], iBond Universal [IBU], or Scotchbond Universal [SBU]), and enamel conditioning agent (PA or EDTA). The specimens were stored for 24 h and tested under shear stress at 1.0 mm/min to determine the µSBS. The adhesive-enamel interfaces were evaluated for in situ DC using micro-Raman spectroscopy. The enamel-etching pattern was evaluated using a scanning electron microscope. The µSBS and in situ DC data were analyzed separately using three-way ANOVA and Tukey's post-hoc test (a = 0.05). RESULTS: Sound enamel showed higher µSBS and in situ DC compared to fluorotic enamel (p < 0.05). However, no significant difference was observed for µSBS, in situ DC (p > 0.05), or etching patterns when PA and EDTA etching were compared in sound and fluorotic enamel. Moreover, CUB and SBU showed higher mean µSBS than did FBU and IBU in both sound and fluorotic enamel (p < 0.05). CONCLUSIONS: Compared to PA, active pre-conditioning with EDTA showed similar µSBS and enamel etching patterns for all the adhesives in fluorotic enamel, without compromising the in situ DC.
Assuntos
Colagem Dentária , Adesivos/análise , Adesivos/farmacologia , Colagem Dentária/métodos , Cimentos Dentários/química , Esmalte Dentário , Ácido Edético , Humanos , Teste de Materiais , Cimentos de Resina/química , Resistência ao Cisalhamento , Propriedades de SuperfícieRESUMO
Dental caries is a multifactorial, biofilm-dependent infectious disease that develops when detrimental changes occur in the oral cavity microenvironment. The antimicrobial and antivirulence properties of the essential oil obtained from the leaves of Eugenia brejoensis Mazine (EBEO) have been reported against Gram-positive and Gram-negative bacteria. Herein, the antimicrobial action of EBEO towards Streptococcus mutans is reported, along with the development and characterization of dental adhesives doped with. The minimum inhibitory concentration (MIC) and minimum bactericidal concentration (MBC) of EBEO were determined against S. mutans, while its toxicity was analyze using Tenebrio molitor larvae. EBEO (MIC and 10×MIC) was incorporated into the Ambar Advanced Polymerization System® (Ambar APS), a two-step total-etch adhesive system (FGM Dental Group), and the antibiofilm action was evaluated. The reflective strength, modulus of elasticity, degree of conversion, and maximum rate of polymerization of each adhesive were also determined. The MIC and MBC values of EBEO against S. mutans were 62.5 µg/mL. The tested concentrations of EBEO were non-toxic to T. molitor larvae. The formation of S. mutans biofilms was significantly inhibited by EBEO and EBEO-coated resin discs (p < 0.05). Importantly, EBEO incorporation did not affect the mechanical and physicochemical properties in relation to oil-free adhesive version. EBEO showed strong antibacterial and antibiofilm activity against S. mutans, no toxicity effect against T. molitor larvae, and did not jeopardize the physical-chemical properties tested.
RESUMO
PURPOSE: To evaluate the effect of inclusion of two dimethyl sulfoxide (DMSO) concentrations in simplified etch-and-rinse adhesives on dentin bonding durability after three years of water storage. MATERIALS AND METHODS: Forty-two caries-free third molars were divided into six experimental groups (n = 7) according to the following factors: 1) adhesive (Adper Single Bond 2 [SB], 3M Oral Care; Prime&Bond 2.1 [PB], Dentsply Sirona); 2) concentration of DMSO (control group: 0.0% DMSO; addition of 0.2% DMSO [0.2] and 2% DMSO [2.0]). After completing restoration, specimens were stored in water (37°C) for 24 h, sectioned into adhesive-dentin sticks (0.8 mm2), tested for microtensile bond strength (µTBS) at 0.5 mm/min, and examined for nanoleakage (NL) using SEM immediately thereafter or after three years of water storage. Data were subjected to a three-way repeated-measures ANOVA and Tukey's test (α = 0.05) for each property evaluated. RESULTS: After three years of water storage, for both adhesives, the incorporation of 2% DMSO maintained the µTBS when compared to immediate µTBS (p > 0.05). In general, SB resulted in a statistically significantly higher mean of µTBS compared to PB, independent of the DMSO concentration after water storage (p < 0.05). Furthermore, the amount of NL was lower and practically limited to the hybrid layer given the concentrations of 0.2% and 2% DMSO for both tested adhesives after three years. CONCLUSION: The incorporation of DMSO in simplified etch-and-rinse adhesives maintains the long-term stability of the dentin bond.
Assuntos
Colagem Dentária , Adesivos Dentinários , Dentina , Dimetil Sulfóxido , Teste de Materiais , Cimentos de Resina , Resistência à Tração , ÁguaRESUMO
PURPOSE: To evaluate the effect of dimethyl sulfoxide (DMSO) on the microtensile bond strength (µTBS), nanoleakage (NL), and degree of conversion (DC) of universal adhesives on eroded dentin. MATERIALS AND METHODS: One hundred thirty-four extracted (134) human third molars were selected for the study. After the dentin surface was exposed, 128 teeth were randomly assigned to 16 experimental groups as follows: dentin surfaces (sound dentin and eroded dentin), application of DMSO (without or with the application of DMSO), and adhesive strategies (etch-and-rinse [ER] and self-etch [SE]). The universal adhesive systems iBond Universal (IBU) and Scotchbond Universal (SBU) were applied and the teeth were restored using a resin composite. After 24 h in distilled water at 37°C, the samples were sectioned and evaluated for µTBS. Selected sticks from each tooth were used for evaluating NL and DC. The remaining six teeth were used to measure the thickness of the collagen layer of the artificially eroded dentin using scanning electron microscopy. Data on µTBS, NL, and DC (%) were analyzed using three-way ANOVA and Tukey's test (α = 0.05). RESULTS: Significantly lower µTBS (p = 0.0001) and DC (p = 0.01) were observed for eroded dentin than for sound dentin. However, a significant increase in the µTBS (p = 0.0007) and DC (p = 0.001) was observed for both substrates when DMSO was applied. Moreover, the application of DMSO decreased the concentration of silver nitrate at the bottom of the hybrid layer for both sound and eroded dentin (p = 0.002). Eroded dentin showed enlarged tubules with the presence of a collapsed collagen fibril layer approximately 5.0 ± 2.0 mm of thickness. CONCLUSION: The bonding performance of both tested universal adhesives improved on both sound and eroded dentin with DMSO pretreatment.
Assuntos
Colagem Dentária , Infiltração Dentária , Resinas Compostas , Dentina , Adesivos Dentinários , Dimetil Sulfóxido , Humanos , Teste de Materiais , Cimentos de Resina , Resistência à TraçãoRESUMO
To investigate the effect of the dimethyl sulfoxide combined with cross-linking agents on microtensile bond strength, silver nitrate penetration and in situ degree of conversion analysis of adhesives to the erosive dentin treatment with Cola-based soft drink. One hundred and sixty-six molars were assigned to 20 groups: (1) Treatment: Sound dentin; Erosive dentin; Erosive dentin treated with primer of dimethyl sulfoxide; Erosive dentin treated with DMSO primer containing proanthocyanidin and rivoflavin; (2) Adhesive systems: iBond Universal and Scotchbond Universal; and (3) adhesive strategy: etch-and-rinse or self-etch strategy. After restoration, specimens were sectioned into sticks to be tested. The data from microtensile bond strength (MPa), silver nitrate penetration (%) and in situ degree of conversion (%) were analyzed by (three- and two-factor ANOVA; Tukey's test α=5%). The application of dimethyl sulfoxide combined of not with cross-linkers improved all properties evaluated when compared to only erosive dentin treatment with Cola-based soft drink. However, only when dimethyl sulfoxide was combined to cross-linkers, the values of the microtensile bond strength, silver nitrate penetration and in situ degree of conversion in erosive dentin treatment with Cola-based soft drink was similar to sound dentin, for both adhesives and adhesive strategies. The application of dimethyl sulfoxide combined with the collagen cross-linking agent contributed to increasing the bond strength and degree of conversion in erosive lesion dentin, at the same time that significantly reduction of nanoleakage in this substrate.
Assuntos
Colagem Dentária , Adesivos Dentinários , Colágeno , Cimentos Dentários , Dentina , Dimetil Sulfóxido , Teste de Materiais , Cimentos de Resina , Resistência à TraçãoRESUMO
OBJECTIVE: To compare the effectiveness of the pretreatment with sandblasting and deproteinization with NaOCl on bond strength (SBS), in situ conversion degree (CD) of brackets in fluorotic enamel, and enamel etching pattern. METHODS: A total of 90 non-carious maxillary premolars were used. The teeth were then assigned to six experimental groups according to: enamel surface (sound and fluorotic enamel); surface treatment (Regular etch with 37% phosphoric acid [RE]; 5.2% sodium hypochlorite + phosphoric acid [NaOCl + RE]; sandblasting + phosphoric acid [sandblasting + RE]). After storage in distilled water (37°C/24h), the specimens were tested at 1 mm/min until failure (SBS). Enamel-resin cement interfaces were evaluated for CD using micro-Raman spectroscopy. The enamel-etching pattern was evaluated under a scanning electron microscope. Data from SBS and in situ CD values were analyzed using ANOVA two-away and Tukey test (α=0.05). The enamel etching pattern was evaluated only qualitatively. RESULTS: For sound enamel, RE showed the highest SBS values, when compared to NaOCl + RE and Sandblasting + RE groups (p< 0.01). Regarding CD, only NaOCl + RE significantly compromised the mean DC, in comparison with other groups (p= 0.002). For fluorotic enamel, the Sandblasting + RE group significantly increased the mean SBS values, in comparison with RE group (p= 0.01) and no significant change was observed for CD (p> 0.52). CONCLUSIONS: The application of NaOCl or sandblasting associated to phosphoric acid improved the SBS of the brackets in fluorotic enamel without compromising the CD of the resin cement, with improving of enamel interprismatic conditioning.
Assuntos
Colagem Dentária , Braquetes Ortodônticos , Condicionamento Ácido do Dente , Cimentos Dentários , Esmalte Dentário , Teste de Materiais , Ácidos Fosfóricos , Cimentos de Resina , Resistência ao Cisalhamento , Propriedades de SuperfícieRESUMO
PURPOSE: To evaluate 1. the microtensile bond strength (µTBS) and in situ degree of conversion (DC) of adhesives applied using two bonding strategies after silver diamine fluoride (diamine) application on carious dentinal lesions, and 2. dentin etching patterns using SEM and energy dispersive x-ray spectroscopy. MATERIALS AND METHODS: Human molars were randomly divided into 12 experimental groups according to: 1. application of a silver diamine fluoride solution (carious dentinal lesion without silver diamine fluoride treatment [control], with 12% silver diamine fluoride [diamine 12%] or 38% silver diamine fluoride [diamine 38%]); 2. adhesives (Clearfil Universal Bond Quick [CUQ] and Scotchbond Universal [SBU]); 3. adhesive strategy (etch-and-rinse [ER] and self-etch [SE]). After restoration, the specimens were sectioned and submitted to µTBS testing. Sticks from each tooth were used for DC evaluation. To examine the changes induced by diamine before and after phosphoric acid treatment, SEM/EDX analysis was performed. Data from the µTBS and DC tests were analyzed using three-way ANOVA and Tukey's test (α = 0.05). RESULTS: Both concentrations of diamine resulted in a statistically significantly higher mean µTBS compared to the control (p < 0.0001). Diamine 38% showed a statistically significantly higher mean µTBS for both adhesives in SE mode compared to diamine 12% (p < 0.0001). The application of diamine to carious dentinal lesions did not significantly influence the mean DC values for either adhesive (p = 0.72). SBU showed a higher mean DC compared to CUQ (p = 0.03). After diamine treatment, there was an increase in the Ca peak intensity and the presence of residual silver ions mainly when diamine 38% was applied along with the SE approach. CONCLUSION: Independent of the adhesive application approach, the use of diamine may be a promising alternative to increase µTBS without jeopardizing the DC of the two adhesives in carious dentinal lesions.
Assuntos
Colagem Dentária , Cimentos Dentários , Dentina , Fluoretos Tópicos , Humanos , Compostos de Amônio Quaternário , Compostos de Prata , Resistência à TraçãoRESUMO
To evaluate the effect of combining 5% hydrofluoric acid (HF) and silane (SI) with the self-etching ceramic primer on the immediate and after 1-year of water storage on bonding efficacy, conditioning pattern (CP) and chemical interaction (CI) to the lithium disilicate. A total of 16 CAD/CAM blocks of lithium disilicate (LD) were cut into four square sections (n=64). For bonding efficacy evaluation, the LD specimens were divided into 4 groups (n=10): 1) HF+SI; 2) self-etching ceramic primer (MEP); 3) HF+MEP; 4) MEP+SI. After each treatment, an adhesive system was applied and Tygon matrices were filled with a dual-cured resin cement followed by light curing. Cylinder specimens (0.8 mmx0.5mm) were stored in water (37 °C for 24 h or 1-year) and submitted to the µSBS test (2-way ANOVA and Tukey's test; a=0.05). CP and CI were only evaluated qualitatively. No significant difference on the µSBS was observed between groups (p=0.73), but reduced µSBS was observed after 1-year of water storage (p>0.0001). After application of HF+SI and MEP, reduction in a number of siloxane bonds was observed, suggesting the coupling of SI on the LD surface. HF or HF+MEP produced a higher dissolution of the glassy matrix than the use of MEP alone. The MEP can be an alternative to traditional ceramic treatment once the chemical interaction and long-term bond strength were similar between both groups. The association of hydrofluoric acid or silane with a self-etching ceramic primer did not add any benefits in terms of chemical interaction and bonding stability.