Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Europace ; 24(6): 938-947, 2022 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-34849726

RESUMO

AIMS: To non-invasively characterize, by means of late gadolinium enhancement cardiac magnetic resonance (LGE-CMR), scar differences, and potential variables associated with ventricular tachycardia (VT) occurrence in chronic post-myocardial infarction (MI) patients. METHODS AND RESULTS: A case-control study was designed through retrospective LGE-CMR data analysis of chronic post-MI patients (i) consecutively referred for VT substrate ablation after a first VT episode (n = 66) and (ii) from a control group (n = 84) with no arrhythmia evidence. The myocardium was characterized differentiating core, border zone (BZ), and BZ channels (BZCs) using the ADAS 3D post-processing imaging platform. Clinical and scar characteristics, including a novel parameter, the BZC mass, were compared between both groups. One hundred and fifty post-MI patients were included. Four multivariable Cox proportional hazards regression models were created for total scar mass, BZ mass, core mass, and BZC mass, adjusting them by age, sex, and left ventricular ejection fraction (LVEF). A cut-off of 5.15 g of BZC mass identified the cases with 92.4% sensitivity and 86.9% specificity [area under the ROC curve (AUC) 0.93 (0.89-0.97); P < 0.001], with a significant increase in the AUC compared to other scar parameters (P < 0.001 for all pairwise comparisons). Adding BZC mass to LVEF allowed to reclassify 33.3% of the cases and 39.3% of the controls [net reclassification improvement = 0.73 (0.71-0.74)]. CONCLUSIONS: The mass of BZC is the strongest independent variable associated with the occurrence of sustained monomorphic ventricular tachycardia in post-MI patients after adjustment for age, sex, and LVEF. Border zone channel mass measurement could permit a more accurate VT risk stratification than LVEF in chronic post-MI patients.


Assuntos
Infarto do Miocárdio , Taquicardia Ventricular , Arritmias Cardíacas/complicações , Arritmias Cardíacas/etiologia , Estudos de Casos e Controles , Cicatriz , Meios de Contraste , Gadolínio , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/patologia , Estudos Retrospectivos , Volume Sistólico , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/etiologia , Função Ventricular Esquerda
2.
Europace ; 23(8): 1285-1294, 2021 08 06.
Artigo em Inglês | MEDLINE | ID: mdl-33846728

RESUMO

AIMS: To assess potential benefits of a local activation time (LAT) automatic acquisition protocol using wavefront annotation plus an ECG pattern matching algorithm [automatic (AUT)-arm] during premature ventricular complex (PVC) ablation procedures. METHODS AND RESULTS: Prospective, randomized, controlled, and international multicentre study (NCT03340922). One hundred consecutive patients with indication for PVC ablation were enrolled and randomized to AUT (n = 50) or manual (MAN, n = 50) annotation protocols using the CARTO3 navigation system. The primary endpoint was mapping success. Clinical success was defined as a PVC-burden reduction of ≥80% in the 24-h Holter within 6 months after the procedure. Mean age was 56 ± 14 years, 54% men. The mean baseline PVC burden was 25 ± 13%, and mean left ventricular ejection fraction (LVEF) 55 ± 11%. Baseline characteristics were similar between the groups. The most frequent PVC-site of origin were right ventricular outflow tract (41%), LV (25%), and left ventricular outflow tract (17%), without differences between groups. Radiofrequency (RF) time and number of RF applications were similar for both groups. Mapping and procedure times were significantly shorter in the AUT-arm (25.5 ± 14.3 vs. 32.8 ± 12.6 min, P = 0.009; and 54.8 ± 24.8 vs. 67.4 ± 25.2, P = 0.014, respectively), while more mapping points were acquired [136 (94-222) AUT vs. 79 (52-111) MAN; P < 0.001]. Mapping and clinical success were similar in both groups. There were no procedure-related complications. CONCLUSION: The use of a complete automatic protocol for LAT annotation during PVC ablation procedures allows to achieve similar clinical endpoints with higher procedural efficiency when compared with conventional, manual annotation carried out by expert operators.


Assuntos
Ablação por Cateter , Complexos Ventriculares Prematuros , Adulto , Idoso , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia
3.
Heart Rhythm ; 18(10): 1709-1716, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34029733

RESUMO

BACKGROUND: Pacemapping (PM) is a useful maneuver for aiding premature ventricular complex (PVC) ablation. Its standalone clinical value is still to be defined. OBJECTIVES: The purpose of this study was to analyze the efficacy of a predefined PM protocol for low-burden PVC ablation, regardless of their site of origin (SOO) and the presence of structural heart disease. METHODS: This was a prospective, nonrandomized, multicenter study. The PM protocol was performed when <1 PVC/min was found. The "target area" was delimited by the 3 best matching points >94% correlation, and 3 radiofreqency (RF) applications were delivered. RESULTS: Of 185 patients, 105 (57%) underwent activation mapping, 60 (32%) were PM-guided, and 20 (11%) were canceled due to absence of PVCs. Baseline QRS, PVC burden, and outflow tract origin were independent predictors of PM-guided ablation. A higher proportion of right ventricular outflow tract SOO in the PM group (52% vs 40%; P = .03) was observed. Mean target area was 0.6 ± 0.9 cm2. Mean 10-ms isochronal area in local activation time (LAT)-guided procedures was higher (1.7 ± 2.3 cm2; P <.001). Mean number of PM matching points acquired was 39 ± 21 (range 6-98). Mean mapping and RF times were similar in both groups. However, significantly shorter procedural (53 ± 24 vs 61 ± 26 minutes; P = .04) as well as RF times (111 ± 51 vs 149 ± 149 seconds; P = .05) were needed in the PM group using the proposed protocol. Global clinical success reached 87% for the PM group and 90% (P = .58) the for LAT mapping group. CONCLUSION: When LAT mapping is precluded, application of a PM-guided ablation protocol directed to >94% matching correlation target area is a more efficient alternative with comparable clinical results.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/métodos , Eletrocardiografia Ambulatorial/métodos , Ventrículos do Coração/fisiopatologia , Volume Sistólico/fisiologia , Complexos Ventriculares Prematuros/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento , Complexos Ventriculares Prematuros/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA