Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Med Dosim ; 38(4): 407-12, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23810414

RESUMO

To compare 2 beam arrangements, sectored (beam entry over ipsilateral hemithorax) vs circumferential (beam entry over both ipsilateral and contralateral lungs), for static-gantry intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) delivery techniques with respect to target and organs-at-risk (OAR) dose-volume metrics, as well as treatment delivery efficiency. Data from 60 consecutive patients treated using stereotactic body radiation therapy (SBRT) for primary non-small-cell lung cancer (NSCLC) formed the basis of this study. Four treatment plans were generated per data set: IMRT/VMAT plans using sectored (-s) and circumferential (-c) configurations. The prescribed dose (PD) was 60Gy in 5 fractions to 95% of the planning target volume (PTV) (maximum PTV dose ~ 150% PD) for a 6-MV photon beam. Plan conformality, R50 (ratio of volume circumscribed by the 50% isodose line and the PTV), and D2cm (Dmax at a distance ≥2cm beyond the PTV) were evaluated. For lungs, mean doses (mean lung dose [MLD]) and percent V30/V20/V10/V5Gy were assessed. Spinal cord and esophagus Dmax and D5/D50 were computed. Chest wall (CW) Dmax and absolute V30/V20/V10/V5Gy were reported. Sectored SBRT planning resulted in significant decrease in contralateral MLD and V10/V5Gy, as well as contralateral CW Dmax and V10/V5Gy (all p < 0.001). Nominal reductions of Dmax and D5/D50 for the spinal cord with sectored planning did not reach statistical significance for static-gantry IMRT, although VMAT metrics did show a statistically significant decrease (all p < 0.001). The respective measures for esophageal doses were significantly lower with sectored planning (p < 0.001). Despite comparable dose conformality, irrespective of planning configuration, R50 significantly improved with IMRT-s/VMAT-c (p < 0.001/p = 0.008), whereas D2cm significantly improved with VMAT-c (p < 0.001). Plan delivery efficiency improved with sectored technique (p < 0.001); mean monitor unit (MU)/cGy of PD decreased from 5.8 ± 1.9 vs 5.3 ± 1.7 (IMRT) and 2.7 ± 0.4 vs 2.4 ± 0.3 (VMAT). The sectored configuration achieves unambiguous dosimetric advantages over circumferential arrangement in terms of esophageal, contralateral CW, and contralateral lung sparing, in addition to being more efficient at delivery.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/cirurgia , Neoplasias Pulmonares/cirurgia , Radiocirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA