Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Circulation ; 2024 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-39327797

RESUMO

BACKGROUND: Substernal lead placement of the extravascular implantable cardioverter-defibrillator (EV ICD) permits both defibrillation at thresholds similar to those seen with transvenous ICDs and effective antitachycardia pacing (ATP), while avoiding the vasculature and associated complications. The global Pivotal study has shown the EV ICD system to be safe and effective through 6 months, but long-term experience has yet to be published. We aim to report the performance and safety of the EV ICD system throughout the study. METHODS: The EV ICD Pivotal study was a prospective, global, single-arm, pre-market clinical study. Individuals with a class I or IIa indication for a single-chamber ICD per guidelines were enrolled. Freedom from major system- or procedure-related complications, as well as appropriate and inappropriate therapy rates, were assessed through 3 years using the Kaplan-Meier method. Anti-tachycardia pacing success was calculated using simple proportions. RESULTS: An implant was attempted in 316 patients [25.3% female, 53.8±13.1 years old, 81.6% primary prevention, LVEF 38.9%±15.4%]. Of 299 patients with a successful implant, 24 experienced 82 spontaneous arrhythmic episodes that were appropriately treated with either ATP only (38, 46.3%), shock only (34, 41.5%), or both (10, 12.2%) for a Kaplan-Meier-estimated rate of first any appropriate therapy of 9.2% at 3 years. Antitachycardia pacing was successful in 77.1% (37/48) of episodes, and ATP usage significantly increased from discharge to last follow-up visit (P<0.0001). Shock therapy was successful in 100% (27/27) of discrete, spontaneous ventricular arrhythmias. The inappropriate shock rates at 1 and 3 years were 9.8% and 17.5%, respectively, with P-wave oversensing the predominant cause. No major intraprocedural complications were reported and the estimated freedom from system- or procedure-related major complications was 91.9% at 1 year and 89.0% at 3 years. The most common major complications were lead dislodgement (10 events; n=9 patients, 2.8%), postoperative wound or device pocket infection (n=8, 2.5%), and device inappropriate shock delivery (n=4, 1.3%). Twenty-four system revisions were performed as a result of major complications related to the EV ICD system or procedure. CONCLUSIONS: From implant to study completion, the EV ICD Pivotal study demonstrated that a single integrated system with an extravascular lead placed in the substernal space maintains high ATP success, effective defibrillation, and a consistent safety profile.

2.
N Engl J Med ; 387(14): 1292-1302, 2022 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-36036522

RESUMO

BACKGROUND: The extravascular implantable cardioverter-defibrillator (ICD) has a single lead implanted substernally to enable pause-prevention pacing, antitachycardia pacing, and defibrillation energy similar to that of transvenous ICDs. The safety and efficacy of extravascular ICDs are not yet known. METHODS: We conducted a prospective, single-group, nonrandomized, premarket global clinical study involving patients with a class I or IIa indication for an ICD, all of whom received an extravascular ICD system. The primary efficacy end point was successful defibrillation at implantation. The efficacy objective would be met if the lower boundary of the one-sided 97.5% confidence interval for the percentage of patients with successful defibrillation was greater than 88%. The primary safety end point was freedom from major system- or procedure-related complications at 6 months. The safety objective would be met if the lower boundary of the one-sided 97.5% confidence interval for the percentage of patients free from such complications was greater than 79%. RESULTS: A total of 356 patients were enrolled, 316 of whom had an implantation attempt. Among the 302 patients in whom ventricular arrhythmia could be induced and who completed the defibrillation testing protocol, the percentage of patients with successful defibrillation was 98.7% (lower boundary of the one-sided 97.5% confidence interval [CI], 96.6%; P<0.001 for the comparison with the performance goal of 88%); 299 of 316 patients (94.6%) were discharged with a working ICD system. The Kaplan-Meier estimate of the percentage of patients free from major system- or procedure-related complications at 6 months was 92.6% (lower boundary of the one-sided 97.5% CI, 89.0%; P<0.001 for the comparison with the performance goal of 79%). No major intraprocedural complications were reported. At 6 months, 25 major complications were observed, in 23 of 316 patients (7.3%). The success rate of antitachycardia pacing, as assessed with generalized estimating equations, was 50.8% (95% CI, 23.3 to 77.8). A total of 29 patients received 118 inappropriate shocks for 81 arrhythmic episodes. Eight systems were explanted without extravascular ICD replacement over the 10.6-month mean follow-up period. CONCLUSIONS: In this prospective global study, we found that extravascular ICDs were implanted safely and were able to detect and terminate induced ventricular arrhythmias at the time of implantation. (Funded by Medtronic; ClinicalTrials.gov number, NCT04060680.).


Assuntos
Desfibriladores Implantáveis , Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Humanos , Estudos Prospectivos , Resultado do Tratamento
3.
Bioinformatics ; 40(8)2024 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-39078114

RESUMO

SUMMARY: Genome assembly projects have grown exponentially due to breakthroughs in sequencing technologies and assembly algorithms. Evaluating the quality of genome assemblies is critical to ensure the reliability of downstream analysis and interpretation. To fulfil this task, we have developed the AssemblyQC pipeline that performs file-format validation, contaminant checking, contiguity measurement, gene- and repeat-space completeness quantification, telomere inspection, taxonomic assignment, synteny alignment, scaffold examination through Hi-C contact-map visualization, and assessments of completeness, consensus quality and phasing through k-mer analysis. It produces a comprehensive HTML report with method descriptions, tables, and visualizations. AVAILABILITY AND IMPLEMENTATION: The pipeline uses Nextflow for workflow orchestration and adheres to the best-practice established by the nf-core community. This pipeline offers a reproducible, scalable, and portable method to assess the quality of genome assemblies-the code is available online at GitHub: https://github.com/Plant-Food-Research-Open/assemblyqc.


Assuntos
Software , Análise de Sequência de DNA/métodos , Algoritmos , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Genoma , Genômica/métodos
4.
New Phytol ; 242(5): 2270-2284, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38532557

RESUMO

Floral nectar composition beyond common sugars shows great diversity but contributing genetic factors are generally unknown. Manuka (Leptospermum scoparium) is renowned for the antimicrobial compound methylglyoxal in its derived honey, which originates from the precursor, dihydroxyacetone (DHA), accumulating in the nectar. Although this nectar trait is highly variable, genetic contribution to the trait is unclear. Therefore, we investigated key gene(s) and genomic regions underpinning this trait. We used RNAseq analysis to identify nectary-associated genes differentially expressed between high and low nectar DHA genotypes. We also used a manuka high-density linkage map and quantitative trait loci (QTL) mapping population, supported by an improved genome assembly, to reveal genetic regions associated with nectar DHA content. Expression and QTL analyses both pointed to the involvement of a phosphatase gene, LsSgpp2. The expression pattern of LsSgpp2 correlated with nectar DHA accumulation, and it co-located with a QTL on chromosome 4. The identification of three QTLs, some of the first reported for a plant nectar trait, indicates polygenic control of DHA content. We have established plant genetics as a key influence on DHA accumulation. The data suggest the hypothesis of LsSGPP2 releasing DHA from DHA-phosphate and variability in LsSgpp2 gene expression contributing to the trait variability.


Assuntos
Di-Hidroxiacetona , Regulação da Expressão Gênica de Plantas , Leptospermum , Néctar de Plantas , Locos de Características Quantitativas , Locos de Características Quantitativas/genética , Néctar de Plantas/metabolismo , Di-Hidroxiacetona/metabolismo , Leptospermum/metabolismo , Monoéster Fosfórico Hidrolases/genética , Monoéster Fosfórico Hidrolases/metabolismo , Genes de Plantas , Genótipo , Mapeamento Cromossômico , Cromossomos de Plantas/genética , Proteínas de Plantas/genética , Proteínas de Plantas/metabolismo
5.
Heart Vessels ; 32(11): 1390-1399, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28623398

RESUMO

Coronary heart disease is associated with high morbidity and mortality. Endothelial dysfunction in affected patients is linked to long-term atherosclerotic disease progression and cardiovascular event rates. The present paper reports on changes in the levels of endothelial progenitor cells (VEGFR2/CD133/CD34), essential for endothelial repair, and of endothelial microvesicles (CD31/annexin V) as indicators of endothelial lesion, in patients undergoing coronary bypass surgery with respect both to baseline levels and to counts in healthy subjects. In an observational descriptive study, 31 patients scheduled for coronary revascularization surgery were compared with those of 25 healthy controls. In a subsequent longitudinal study, patients undergoing surgery were monitored at 5 timepoints up until 48 h after surgery. Endothelial progenitor cell (VEGFR2/CD133/CD34) and endothelial microvesicle (CD31/annexin V) levels were quantified by flow cytometry. Baseline endothelial progenitor cell counts in coronary patients were significantly lower than those of healthy controls (p < 0.001); however, after surgery, levels rose steadily over all 5 timepoints to 48 h  with statistically significant differences (p < 0.001) between intra-operative and 48 h after surgery (T5). Endothelial microvesicle levels were significantly higher in coronary patients prior to surgery than in healthy controls (p < 0.001), and despite declining at 48 h remained significantly higher than those of controls (p < 0.001). Coronary surgery has had a positive impact on the endothelium in the patients, prompting a decrease in signs of endothelial dysfunction and a considerable improvement in the endothelial repair mechanisms involved in angiogenesis, playing an important role in the inflammatory response and the remodelling process of ischemic myocardium in postoperative period.


Assuntos
Anexinas/sangue , Doença da Artéria Coronariana/sangue , Vasos Coronários/metabolismo , Endotélio Vascular/metabolismo , Revascularização Miocárdica , Vasodilatação/fisiologia , Biomarcadores/sangue , Micropartículas Derivadas de Células/metabolismo , Micropartículas Derivadas de Células/patologia , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/fisiopatologia , Vasos Coronários/cirurgia , Células Progenitoras Endoteliais/metabolismo , Células Progenitoras Endoteliais/patologia , Endotélio Vascular/patologia , Endotélio Vascular/fisiopatologia , Citometria de Fluxo , Seguimentos , Humanos , Período Pós-Operatório , Prognóstico , Estudos Prospectivos
6.
Children (Basel) ; 11(9)2024 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-39334645

RESUMO

BACKGROUND: One of the most common food allergies in the pediatric population is allergy to cow's milk protein (CMPA). Treatment consists of avoiding cow's milk proteins in lactating mothers and/or using therapeutic formulas based on hydrolysates or vegetable formulas. In infants with CMPA at diagnosis, a different gut microbial profile has been found compared to healthy children, with a reduction in beneficial bacteria. The aim of this study was to evaluate changes in the gut microbiota profile and its metabolites, dietary patterns and anthropometric variables in a pediatric cohort with CMPA after six months on a restrictive diet compared to healthy controls. METHODS: In total, 21 patients diagnosed with CMPA and a control group of 24 healthy infants participated in this study. The fecal microbiota of all participants were investigated by metataxonomic analysis of 16S rDNA amplicons, and fecal short-chain fatty acids were measured by gas chromatography. Epidemiological assessment and dietary questionnaires were carried out for both groups. RESULTS: Regarding growth, no significant differences were found, but differences in dietary intake of some macro- and micronutrients were observed. Patients who were breastfed at six months had higher bifidobacteria and lipid intakes than patients fed with hydrolyzed formulas. CONCLUSIONS: Although the growth of CMPA infants fed with therapeutic formula is similar to breastfed CMPA infants, there are differences in microbiota composition and macronutrient intake that underline the importance of continued breastfeeding in CMPA cases.

7.
Eur J Cardiothorac Surg ; 55(6): 1160-1167, 2019 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-30608571

RESUMO

OBJECTIVES: The decision about whether to use a biological or a mechanical prosthesis for aortic valve replacement remains controversial in patients between 50 and 65 years of age and has yet to be addressed in a Mediterranean population. This research aimed to analyse long-term survival and major morbidity rates (30-day mortality, stroke, any prosthetic reoperation and major bleeding) within this population. METHODS: Our multicentre observational retrospective study included all subjects aged 50-65 years who had a primary isolated aortic valve replacement due to severe aortic stenosis at 7 public hospitals from Andalusia (Spain) between 2000 and 2015. Concomitant surgery, reoperations and endocarditis were the exclusion criteria. A total of 1443 patients were enrolled in the study (272 with biological and 1171 with mechanical valves). Multivariate analyses including a 2:1 propensity score matching (506 mechanical and 257 biological prostheses) were conducted. RESULTS: Bioprostheses were implanted in 18.8% (n = 272): 35% were women; the mean EuroSCORE-I was 3%. The mean follow-up was 8.1 ± 4.9 years in a matched sample: 8.8 ± 4.9 years in those receiving a mechanical vs 7.1 ± 4.5 years in those receiving a biological prosthesis (P = 0.001). In the paired sample, the 15-year survival rate was 73% in those who had a biological vs 76% in those who had a mechanical valve [hazard ratio (HR) 0.80, 95% confidence interval (CI) 0.54-1.20; P = 0.159]. No significant differences were observed in patients ≥55 years old (74% of 15-year survival in both groups: HR 0.88, 95% CI 0.56-1.34; P = 0.527). A higher rate of major bleeding was found in patients with a mechanical prosthesis (P = 0.004), whereas reoperation was more frequent among those with a biological prosthesis (P = 0.01). CONCLUSIONS: Long-term survival was comparable in patients above 55 years of age. Mechanical prostheses were associated with more major bleeding and bioprostheses, with more reoperations. A bioprosthesis in patients above 55 years old is a reasonable choice. CLINICAL TRIAL REGISTRATION NUMBER: NCT03239509.


Assuntos
Valva Aórtica/cirurgia , Bioprótese , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Complicações Pós-Operatórias/epidemiologia , Pontuação de Propensão , Fatores Etários , Idoso , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Prognóstico , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Espanha/epidemiologia , Taxa de Sobrevida/tendências
8.
Rev Esp Cardiol ; 57(1): 29-36, 2004 Jan.
Artigo em Espanhol | MEDLINE | ID: mdl-14746715

RESUMO

INTRODUCTION AND OBJECTIVES: We analyzed the incidence, risk factors and clinical impact of pulmonary homograft dysfunction after the Ross procedure in our patients. PATIENTS AND METHOD: All patients were evaluated at 3, 6 and 12 months, and annually thereafter. Patients with a transhomograft pressure gradient greater than 30 mmHg were referred for cardiac magnetic resonance imaging. RESULTS: At the end of the study, 9 patients (11.8%) showed a transhomograft pressure gradient >30 mmHg after a mean period of 15.3 months post-surgery. Mean transhomograft pressure gradient was 19.8 (16.2%) (range, 2-100 mmHg). All patients were in functional class I, except 2 who were in New York Heart Association class II with severe stenosis. These 2 patients were treated percutaneously with stent placement and no reoperation. No association was found between clinical outcome and sex, age or homograft diameter. We found a trend toward greater perioperative use of plasma, platelets and red cells in the group of patients in comparison to controls, although the difference was significant only for postoperative use of plasma (1.7 [3] vs 5.5 [5.3] units; P<0.05). Cardiac magnetic resonance imaging showed stenosis predominantly in the body of the homograft, whereas the valvular component itself remained competent. Right ventricular hypertrophy was mild or very mild in 7 patients and moderate in 2. CONCLUSIONS: The incidence of some degree of pulmonary homograft dysfunction after the Ross procedure was non-negligible, but its clinical impact seems to be slight. Patients with severe stenosis were treated successfully via a percutaneous approach. The use of blood products might be a risk factor for the development of this complication.


Assuntos
Complicações Pós-Operatórias/epidemiologia , Estenose da Valva Pulmonar/epidemiologia , Valva Pulmonar/transplante , Adolescente , Adulto , Cateterismo Cardíaco , Criança , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Incidência , Imageamento por Ressonância Magnética , Masculino , Análise Multivariada , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/cirurgia , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/patologia , Estenose da Valva Pulmonar/patologia , Estenose da Valva Pulmonar/cirurgia , Radiografia , Reoperação , Transplante Autólogo , Resultado do Tratamento
9.
Interact Cardiovasc Thorac Surg ; 17(2): 423-5, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23667065

RESUMO

Active valvular endocarditis could be considered a contraindication to heart transplantation. Nevertheless, there have been some reports of success with this form of treatment, despite the characteristics of the infection and its aggressive nature. Here, we describe the case of a patient with acute bicuspid aortic valvular endocarditis caused by Staphylococcus aureus and with a periannular abscess. Cryopreserved aortic homograft replacement of the aortic root was initially carried out, in addition to debridement and reconstruction of the interventricular septum with a pericardial patch. Early recurrence occurred, however, with extensive tissue destruction, a periaortic abscess and involvement of multiple valves, associated with severe sepsis. In view of the failure of 'conventional' surgery, an emergency heart transplantation was decided on after discussing the case with the Spanish National Transplant Organization (ONT), because of the theoretical contraindication of transplantation in this case. Transplantation was finally carried out after a waiting period of 3 days, in emergency code conditions, and the postoperative course proved uneventful, with no reinfection during the follow-up period. The present case suggests that heart transplantation may be an alternative option in patients suffering aggressive endocarditis with extensive involvement of the heart structures.


Assuntos
Endocardite Bacteriana/cirurgia , Transplante de Coração , Doenças das Valvas Cardíacas/cirurgia , Infecções Estafilocócicas/cirurgia , Adulto , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/microbiologia , Transplante de Coração/efeitos adversos , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/microbiologia , Humanos , Masculino , Seleção de Pacientes , Recidiva , Reoperação , Fatores de Risco , Infecções Estafilocócicas/diagnóstico , Infecções Estafilocócicas/microbiologia , Resultado do Tratamento
10.
Metabolism ; 60(12): 1719-25, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21663925

RESUMO

The objective was to evaluate the need for vitamin D prophylaxis in healthy infants. This was a prospective and randomized study performed at primary care clinics. Eighty-eight full-term 1-month-old healthy infants were randomly assigned to receive (n = 41) or not (n = 47) 402 IU/d of vitamin D for 1 year. Primary outcome measures were serum 25-hydroxyvitamin D (25OHD) and parathyroid hormone (PTH) concentrations at 3, 6, and 12 months of age; secondary measures included data on feeding, habitat, season of birth, sun exposure, and physical examination. At 3 and 6 months of age, serum 25OHD levels (±SD) were significantly higher (P < .001) in the prophylaxis group. In the group without prophylaxis, serum 25OHD increased with age; and breast-fed infants aged 3 months had the lowest value (20.2 ± 9.4 ng/mL), which was significantly (P = .001) lower than that of formula-fed infants (35.0 ± 9.7 ng/mL). The PTH levels were not influenced by the prophylaxis or feeding. No influence of either the habitat or season of birth on serum 25OHD concentrations was demonstrated. No infant had clinical signs of vitamin D deficiency. Serum 25OHD and PTH concentrations were weakly but significantly correlated (r = -0.29, P = .009) at 3 months of age. Healthy infants without vitamin D prophylaxis had lower circulating concentrations of 25OHD at 3 and 6 months of age, the lowest value being found in 3-month breast-fed infants. The clinical relevance of these findings is probably negligible because serum 25OHD levels spontaneously increased with age and were not associated with high serum PTH. Clinical manifestations of rickets were not observed.


Assuntos
Necessidades e Demandas de Serviços de Saúde , Hormônio Paratireóideo/sangue , Prevenção Primária , Deficiência de Vitamina D/prevenção & controle , Vitamina D/análogos & derivados , Vitamina D/administração & dosagem , Fatores Etários , Biomarcadores/sangue , Aleitamento Materno , Humanos , Lactente , Masculino , Atenção Primária à Saúde , Prevenção Primária/métodos , Estudos Prospectivos , Estações do Ano , Espanha , Resultado do Tratamento , Vitamina D/sangue , Deficiência de Vitamina D/sangue
13.
Arch. Inst. Cardiol. Méx ; 69(3): 235-40, mayo-jun. 1999. tab, ilus
Artigo em Espanhol | LILACS | ID: lil-258833

RESUMO

La trombosis venosa profunda puede causar embolias pulmonares. En raras ocasiones, la embolización se produce, no directamente en el árbol arterial pulmonar, sino en las cavidades cardiacas derechas. Aunque el valor de la ecocardiografía en el diagnóstico es bien reconocido, actualmente no existe consenso en cuanto al tratamiento apropiado. Presentamos seis casos de trombo flotante en aurícula derecha, diagnosticado por ecocardiografía, en pacientes con embolias pulmonares o con shock o síncope sin causa evidente. Se realizó embolectomía quirúrgica en 4 pacientes, y tratamiento fibrinolítico en 2, sin mortalidad hospitalaria. La elevada mortalidad asociada con esta patología puede reducirse con un diagnóstico ecocardiográfico rápido y un tratamiento emergente con fibrinolisis o cirugía. Nuestros datos sugieren la posible utilización de la fibrinolisis como tratamiento de primera elección en casos seleccionados


Assuntos
Humanos , Masculino , Adulto , Fibrinolíticos/administração & dosagem , Quimioterapia Combinada , Ecocardiografia , Embolectomia , Embolia/diagnóstico , Embolia/terapia , Ecocardiografia , Heparina/administração & dosagem , Pulmão , Terapia Trombolítica , Relação Ventilação-Perfusão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA