Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
Lasers Med Sci ; 33(2): 233-240, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29075997

RESUMO

The aim of this study was to evaluate the effect of different output powers of Er,Cr:YSGG laser and the association with tribochemical silica coating on the bond strength between zirconia ceramic and two resin cements. One hundred ninety-two zirconia ceramic bars (IPS e-max ZirCAD Ivoclar Vivadent-) were sectioned (6 × 6 × 4 mm), sintered, and randomly divided into 12 groups for each cement system according to the surface treatment (n = 8): C-without treatment (control); R-tribochemical coating + resin cement (control); 2L-laser (2.0 W) + resin cement; 2LR-laser (2.0 W) + tribochemical coating + resin cement; R2L-tribochemical coating + laser (2.0 W) + resin cement; 2.5L-laser (2.5 W) + resin cement; 2.5LR-laser (2.5 W) + tribochemical coating + resin cement; R2.5L-tribochemical coating + laser (2.5 W) + resin cement; 3L-laser (3.0 W) + resin cement; 3LR-laser (3.0 W) + tribochemical coating + resin cement, R3L-tribochemical coating + laser (3.0 W) + resin cement; and RPHO-tribochemical + resin cement + photoactivation (control). After the surface treatment, the respective primers were applied, and resin cements, Multilink N, Ivoclar Vivadent (M), and Panavia F 2.0, Kuraray Medical Inc. (P), were inserted into Tygon molds which were bonded to the zirconia bars. Each specimen received two cements bars. After 24 h of storage in a relative humidity (100%) at 37 °C, they were evaluated by the microshear test speed of 1 mm/min. The microshear values were analyzed by one-way ANOVA and Tukey's test (α = 0.05). ANOVA showed statistically significant differences among the evaluated groups. The highest bond strength was observed in RPHO, which statistically differed from all groups. The lowest bond strength was observed in M2.5L (Multilink N) and in P3LR (Panavia F 2.0). It can be concluded that the lowest power output tested was suitable and showed bond strength values similar to tribochemical silica deposition. The light curing is important to adhesion and the tribosilicatizated surface achieves similar microshear values to untreated surface in absence of light.


Assuntos
Colagem Dentária , Cimentos Dentários/química , Lasers de Estado Sólido , Resistência ao Cisalhamento , Dióxido de Silício/química , Zircônio/química , Resinas Acrílicas/química , Cerâmica/química , Resinas Compostas/química , Lâmpadas de Polimerização Dentária , Teste de Materiais , Poliuretanos/química , Cimentos de Resina/química , Propriedades de Superfície
2.
J Esthet Restor Dent ; 30(4): 346-351, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29766651

RESUMO

OBJECTIVE: To test the effects of different adhesive protocols and silane application on the adhesive durability to a Lithium Disilicate reinforced glass ceramic. METHODS: Forty disks of 13 mm diameter (E.max Press) were used. After etching with 9.5% HF for 20 seconds, disks were randomly assigned into 4 groups according to the adhesive/silane protocol: silane application only (SIL); silane application followed by adhesive (SILXP-XP Bond); silane-containing adhesive (SBU-ScotchBond Universal); silane application followed by silane-containing adhesive (SILSBU). Four resin composite cylinders of 1-mm diameter and 3-mm height were made on each ceramic disk and tested in shear. Specimens were stored in water for 24 hours or 12 months prior to testing. Results were statistically analyzed by two-way ANOVA and Tukey test. RESULTS: After 24 hours, the highest SBS values were observed for SILXP and SILSBU. However, after 12 months, SILXP and SILSBU presented a significant reduction in SBS, while the highest SBS were observed for SIL. For SBU, no significant reduction in SBS was observed, however, it showed the lowest SBS after 12 months. CONCLUSIONS: Regardless of the presence of silane in the composition of SBU, previous silane application is still recommended prior to cementation of Lithium Disilicate. CLINICAL SIGNIFICANCE: The application of silane as a separate step is recommended prior to cementation of Lithium Disilicate reinforced glass-ceramic, independent of the presence of silane within the universal adhesive solution.


Assuntos
Colagem Dentária , Silanos , Cerâmica , Cimentos Dentários , Porcelana Dentária , Teste de Materiais , Cimentos de Resina , Propriedades de Superfície
3.
J Craniofac Surg ; 27(3): 784-8, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27100634

RESUMO

OBJECTIVE: This study investigated the osteoblastic behavior to yttrium-stabilized tetragonal zirconia polycrystal (Y-TZP) surface after different intensities of erbium, chromium-doped:yttrium, scandium, gallium, and garnet (Er,Cr:YSGG) laser irradiation treatment. MATERIALS AND METHODS: Y-TZP blocks were randomized divided into 4 groups to Er,Cr:YSGG laser irradiation: group G1 = control (no laser irradiation); group G2 = 1.5 W; group G3 = 3.0 W; group G4 = 5.0 W, with air-water irrigation. The irradiated surface roughness (Sa and Ra) topography was evaluated. MC3T3-E1 osteoblast cells were cultured and seeded onto the treated surfaces at a plate density of 1 × 10 cells/mL. At the third and seventh days cell proliferation was measured by the colorimetric assay methods. The specimens were prepared to scanning electron microscope to observe adhesion and morphology of cells. RESULTS: MTT assay showed adhesion and proliferation of MC3T3-E1 cells in all groups. Compared with group G1 (control), the group G2 had a proliferation 1.4% higher (P > 0.05), the group G3 had a proliferation 3.1% higher (P < 0.05) and group G4 had a proliferation 4.5% higher (P < 0.01). After 7 days there was no difference among the groups (ANOVA, Newman-Keuls). CONCLUSIONS: Er,Cr:YSGG laser irradiation may have contributed to the greater and earlier cell spreading that was observed with the Y-TZP without alterations on surface topography.


Assuntos
Terapia com Luz de Baixa Intensidade/métodos , Osteoblastos/citologia , Osteoblastos/efeitos da radiação , Zircônio , Cromo , Relação Dose-Resposta a Droga , Érbio , Gálio , Humanos , Técnicas In Vitro , Lasers de Estado Sólido/uso terapêutico , Microscopia Eletrônica de Varredura , Escândio , Propriedades de Superfície , Ítrio
4.
Lasers Med Sci ; 30(1): 43-8, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24430726

RESUMO

This study investigated changes in the roughness parameters (Sa in µm(2) and Ra in µm) of yttrium-stabilized tetragonal zirconia polycrystal (Y-TZP) and large-grit sandblasted acid-etched (SLA) titanium (TI) materials after decontamination by erbium chromium-doped:yttrium, scandium, gallium, and garnet (Er,Cr:YSGG) laser irradiation. Twenty disks were analyzed in this study: 10 disks of Y-TZP (5 mm in diameter and 3 mm in height), standardized with CAD-CAM procedures, and 10 disks of SLA TI (5 mm in diameter and 4 mm in thickness). Disks were randomized into four groups (n = 5), according to whether laser irradiation was performed: Y-TZP_G1 and TI_G1 were not treated by laser (control groups), whereas Y-TZP_G2 and TI_G2 were irradiated with Er,Cr:YSGG laser (1.5 W/20 Hz, air-water cooling proportion of 80%/25%). The surface topography of the disks was analyzed by confocal light microscopy. The mean Sa and Ra values were calculated from five profiles from each group. The results were statistically analyzed by t-test at the 95% confidence level (α = 0.05). For Y-TZP, the Sa results (in mean ± SD) for Y-TZP_G1 and Y-TZP_G2 were 2.60 ± 1.1 and 0.80 ± 0.17 µm(2), respectively, and the Ra results were 2.01 ± 0.71 and 0.18 ± 0.15 µm, respectively (both p < .05). For SLA TI, the Sa results for TI_G1 and TI_G2 were 1.99 ± 0.5 and 3.37 ± 0.75 µm(2), respectively, and the Ra results were 1.78 ± 0.53 and 3.84 ± 0.63 µm, respectively (both p < .05). Er,Cr:YSGG laser irradiation alters the surface roughness of zirconia and SLA TI.


Assuntos
Cromo/química , Érbio/química , Lasers de Estado Sólido , Titânio/efeitos da radiação , Zircônio/efeitos da radiação , Condicionamento Ácido do Dente , Propriedades de Superfície , Ítrio/química , Ítrio/farmacologia
5.
Clin Oral Implants Res ; 25(4): 408-16, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23651315

RESUMO

OBJECTIVES: The objective of this systematic review was to evaluate the effects of smoking on the survival rate of dental implants placed in areas of maxillary sinus floor augmentation. MATERIAL AND METHODS: The Cochrane Oral Health Group's Trials Register (CENTRAL), MEDLINE and EMBASE were searched in duplicate up to, and including, October 2012 without language restrictions. Studies were considered eligible for inclusion if they involved the treatment of smokers and non-smokers with titanium implants and sinus floor elevation procedures. The Newcastle-Ottawa Scale and the Cochrane Collaboration's quality assessment tool were used for the assessment of the risk of bias in included studies. Random effects meta-analyses were used to assess the number of implants lost in smokers vs. number of implants lost in non-smokers. RESULTS: Of 3360 potentially eligible papers, eight studies were included. More than half (62.5%) of the studies found that smoking adversely affects implant survival in sites of sinus floor augmentation. Similarly, the pooled analysis indicated a statistically significantly increased risk of implant failure in smokers when the outcomes of all studies available to be included into meta-analysis were evaluated [RR: 1.87 (95% CI: 1.35, 2.58), P = 0.0001]. Conversely, a subgroup analysis including only prospective studies (3 studies) did not reveal significant differences in implant failure between smokers and non-smokers [RR: 1.55 (95% CI: 0.91, 2.65), P = 0.11]. CONCLUSIONS: Although smoking was associated with implant failure in most of individual studies and in the overall meta-analysis, the detrimental effect of smoking was not confirmed when only prospective data were assessed.


Assuntos
Implantes Dentários , Falha de Restauração Dentária , Levantamento do Assoalho do Seio Maxilar , Fumar/efeitos adversos , Humanos , Taxa de Sobrevida
6.
Lasers Med Sci ; 27(1): 31-8, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20859649

RESUMO

The objective of this study was to evaluate the influence of Er:YAG laser (λ = 2.94 µm) on microtensile bond strength (µTBS) and superficial morphology of bovine dentin bleached with 16% carbamide peroxide. Forty bovine teeth blocks (7 × 3 × 3 mm(3)) were randomly assigned to four groups: G1- bleaching and Er:YAG irradiation with energy density of 25.56 J/cm(2) (focused mode); G2 - bleaching; G3 - no-bleaching and Er:YAG irradiation (25.56 J/cm(2)); G4 - control, non-treated. G1 and G2 were bleached with 16% carbamide peroxide for 6 h during 21 days. Afterwards, all blocks were abraded with 320 to 600-grit abrasive papers to obtain flat standardized dentin surfaces. G1 and G3 were Er:YAG irradiated. Blocks were immediately restored with 4-mm-high composite resin (Adper Single Bond 2, Z-250-3 M/ESPE). After 24 h, the restored blocks (n = 9) were serially sectioned and trimmed to an hour-glass shape of approximately 1 mm(2) at the bonded interface area, and tested in tension in a universal testing machine (1 mm/ min). Failure mode was determined at a magnification of 100× using a stereomicroscope. One block of each group was selected for scanning electron microscope (SEM) analysis. µTBS data was analyzed by two-way ANOVA and Tukey test (α = 0.05). Mean bond strengths (SD) in MPa were: G1- 32.7 (5.9)(A); G2- 31.1 (6.3)(A); G3- 25.2 (8.3)(B); G4- 36.7 (9.9).(A) Groups with different uppercase letters were significantly different from each other (p < .05). Enamel bleaching procedure did not affect µTBS values for dentin adhesion. Er:YAG laser irradiation with 25.56 J/cm(2) prior to adhesive procedure of bleached teeth did not affect µTBS at dentin and promoted a dentin surface with no smear layer and opened dentin tubules observed under SEM. On the other hand, Er:YAG laser irradiation prior to adhesive procedure of non-bleached surface impaired µTBS compared to the control group.


Assuntos
Resinas Compostas/efeitos da radiação , Colagem Dentária , Dentina/efeitos da radiação , Lasers de Estado Sólido , Resistência à Tração , Animais , Peróxido de Carbamida , Bovinos , Esmalte Dentário/efeitos dos fármacos , Esmalte Dentário/efeitos da radiação , Dentina/ultraestrutura , Microscopia Eletrônica de Varredura , Peróxidos/farmacologia , Cimentos de Resina/efeitos da radiação , Clareamento Dental , Ureia/análogos & derivados , Ureia/farmacologia
7.
Lasers Med Sci ; 26(1): 133-8, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20803160

RESUMO

Recent studies have shown that direct laser metal sintering (DLMS) produces structures with complex geometry and consequently that allow better osteoconductive properties. The aim of this patient report was to evaluate the early bone response to DLMS implant surface retrieved from human jaws. Four experimental DLMS implants were inserted in the posterior mandible of four patients during conventional dental implant surgery. After 8 weeks, the micro-implants and the surrounding tissue were removed and prepared for scanning electron microscopy (SEM) and histomorphometric analysis to evaluate the bone-implant interface. The SEM and EDX evaluations showed a newly formed tissue composed of calcium and phosphorus. The bone-to-implant contact presented a mean of 60.5 ± 11.6%. Within the limits of this patient report, data suggest that the DLMS surfaces presented a close contact with the human bone after a healing period of 8 weeks.


Assuntos
Implantes Dentários , Osseointegração , Adulto , Ligas , Feminino , Humanos , Lasers de Estado Sólido , Masculino , Mandíbula/patologia , Mandíbula/cirurgia , Microscopia Eletrônica de Varredura , Pessoa de Meia-Idade , Espectrometria por Raios X , Propriedades de Superfície , Fatores de Tempo , Titânio
8.
Photobiomodul Photomed Laser Surg ; 39(6): 403-410, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33567218

RESUMO

Objective: This in vivo study compared two bleaching techniques with regard to the degree of tooth sensitivity (TS), color change, and treatment stability for a 6-month follow-up period. Materials and methods: Sixty volunteers were selected according to inclusion and exclusion criteria and submitted to in-office bleaching. For group 1, we performed one bleaching session with a 35% hydrogen peroxide gel and a second bleaching session after 7 days; for group 2, we performed two bleaching sessions with two applications per session, each session with a 7-day interval, using a light-emitting diodes (LEDs) device emitting violet light (405-410 nm) without employing peroxide-containing bleaching gel. TS was recorded immediately before and immediately after each bleaching session using the Variance Analogic Scale. The color of upper central incisors and upper canines at baseline was recorded immediately after each bleaching session, after 15, 30, and 180 days, with a value-oriented shade guide used by two well-trained observers. Results: The two whitening protocols results were similar regarding the immediate effectiveness and 6-month stability of tooth whitening. Dental bleaching with violet LED did not promote postoperative pain sensitivity at any of the evaluated times. However, dental bleaching performed with 35% hydrogen peroxide promoted higher postoperative pain sensitivity. Conclusions: The violet light alone provided dental bleaching and had the clinical advantage of promoting less immediate postoperative sensitivity; however, an unwanted repigmentation occurred after dental bleaching with light alone.


Assuntos
Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Sensibilidade da Dentina/induzido quimicamente , Seguimentos , Humanos , Peróxido de Hidrogênio/efeitos adversos , Clareamento Dental/efeitos adversos , Clareadores Dentários/efeitos adversos
10.
Lasers Med Sci ; 25(6): 881-9, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19802717

RESUMO

The objective of this study was to evaluate the influence of various pulse widths with different energy parameters of erbium:yttrium-aluminum-garnet (Er:YAG) laser (2.94 mum) on the morphology and microleakage of cavities restored with composite resin. Identically sized class V cavities were prepared on the buccal surfaces of 54 bovine teeth by high-speed drill (n = 6, control, group 1) and prepared by Er:YAG laser (Fidelis 320A, Fotona, Slovenia) with irradiation parameters of 350 mJ/ 4 Hz or 400 mJ/2 Hz and pulse width: group 2, very short pulse (VSP); group 3, short pulse (SP); group 4, long pulse (LP); group 5, very long pulse (VLP). All cavities were filled with composite resin (Z-250-3 M), stored at 37 degrees C in distilled water, polished after 24 h, and thermally stressed (700 cycles/5-55 degrees C). The teeth were impermeabilized, immersed in 50% silver nitrate solution for 8 h, sectioned longitudinally, and exposed to Photoflood light for 10 min to reveal the stain. The leakage was evaluated under stereomicroscope by three different examiners, in a double-blind fashion, and scored (0-3). The results were analyzed by Kruskal-Wallis test (P > 0.05) and showed that there was no significant differences between the groups tested. Under scanning electron microscopy (SEM) the morphology of the cavities prepared by laser showed irregular enamel margins and dentin internal walls, and a more conservative pattern than that of conventional cavities. The different power settings and pulse widths of Er:YAG laser in cavity preparation had no influence on microleakage of composite resin restorations.


Assuntos
Preparo da Cavidade Dentária/métodos , Lasers de Estado Sólido/uso terapêutico , Terapia com Luz de Baixa Intensidade/métodos , Animais , Bovinos , Resinas Compostas , Esmalte Dentário/efeitos da radiação , Esmalte Dentário/ultraestrutura , Infiltração Dentária/prevenção & controle , Restauração Dentária Permanente/métodos , Dentina/efeitos da radiação , Dentina/ultraestrutura , Técnicas In Vitro , Microscopia Eletrônica de Varredura
11.
Lasers Med Sci ; 25(6): 829-34, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19626274

RESUMO

UNLABELLED: The objective of this study was to evaluate in vitro light activation of the nano-filled resin composite Vita shade A1 and A3 with a halogen lamp (QTH) and argon ion laser by Knoop microhardness profile. MATERIALS AND METHODS: Specimens of nanofilled composite resin (Z350-3 M-ESPE) Vita shade A1 and A3 were prepared with a single increment inserted in 2.0-mm-thick and 3-mm diameter disc-shaped Teflon mold. The light activation was performed with QTH for 20 s (with an intensity of approximately 1,000 mW/cm(2) and 700 mW/cm(2)) and argon ion laser for 10 s (with a power of 150 mW and 200 mW). Knoop microhardness test was performed after 24 h and 6 months. The specimens were divided into the 16 experimental groups (n = 10), according to the factors under study: photoactivation form, resin shade, and storage time. Knoop microhardness data was analyzed by a factorial ANOVA and Tukey s tests at the 0.05 level of significance. RESULTS: Argon ion laser was not able to photo-activate the darker shade of the nanofilled resin composite evaluated but when used with 200 mW it can be as effective as QTH to photo-activate the lighter shade with only 50% of the time exposure. After 6 months storage, an increase in the means of Knoop microhardness values were observed. CONCLUSIONS: Light-activation significantly influenced the Knoop microhardness values for the darker nanofilled resin composite.


Assuntos
Resinas Compostas , Lâmpadas de Polimerização Dentária , Lasers de Gás/uso terapêutico , Cor , Análise do Estresse Dentário , Dureza , Humanos , Técnicas In Vitro , Teste de Materiais , Propriedades de Superfície , Fatores de Tempo
12.
J Int Acad Periodontol ; 22(4): 231-235, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-32980835

RESUMO

AIMS: This study evaluated the mechanical properties of mandibular bone tissue retrieved from postmenopausal women under alendronate treatment. METHODS: Twenty postmenopausal women were divided into two groups: healthy postmenopausal subjects (control group) and osteoporotic subjects treated with alendronate (alendronate group). Mandibular bone samples were retrieved with a trephine bur at the time of dental implant placement and fixed in 4% formalin. Samples were processed for hard tissue histology, and the bone surface was analyzed for nanohardness measurement. Nanohardness and elastic modulus were evaluated by using a Berkovich tip with elastic modulus of 1.016x106 MPa, Poisson coefficient of 0.3, and a load of 100 mN. Each cycle was configured with a load time of 18 seconds (speed of 1 mN/second), the discharge time of 18 seconds, and a rest time of 5 seconds during indentation at a depth of 10 µm. RESULTS: The control group presented the highest values for nanohardness and elastic modulus (p less than 0.05) in relation to the osteoporotic subjects. CONCLUSIONS: Within the limitations of the study, it can be concluded that treatment with alendronate negatively influenced the mechanical properties of mandibular bone in postmenopausal women by reducing bone nanohardness and elastic modulus.


Assuntos
Alendronato , Pós-Menopausa , Módulo de Elasticidade , Feminino , Dureza , Humanos , Mandíbula
13.
J Adhes Dent ; 11(3): 221-9, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19603586

RESUMO

PURPOSE: The objective of this in vitro study was to compare the degree of microleakage of composite restorations performed by lasers and conventional drills associated with two adhesive systems. MATERIALS AND METHODS: Sixty bovine teeth were divided into 6 groups (n = 10). The preparations were performed in groups 1 and 2 with a high-speed drill (HD), in groups 3 and 5 with Er:YAG laser, and in groups 4 and 6 with Er,Cr:YSGG laser. The specimens were restored with resin composite associated with an etch-and-rinse two-step adhesive system (Single Bond 2 [SB]) (groups 1, 3, 4) and a self-etching adhesive (One-Up Bond F [OB]) (groups 2, 5, 6). After storage, the specimens were polished, thermocycled, immersed in 50% silver nitrate tracer solution, and then sectioned longitudinally. The specimens were placed under a stereomicroscope (25X) and digital images were obtained. These were evaluated by three blinded evaluators who assigned a microleakage score (0 to 3). The original data were submitted to Kruskal-Wallis and Mann-Whitney statistical tests. RESULTS: The occlusal/enamel margins demonstrated no differences in microleakage for all treatments (p > 0.05). The gingival/dentin margins presented similar microleakage in cavities prepared with Er:YAG, Er,Cr:YSGG, and HD using the etch-and-rinse two-step adhesive system (SB) (p > 0.05); otherwise, both Er:YAG and Er,Cr:YSGG lasers demonstrated lower microleakage scores with OB than SB adhesive (p < 0.05). CONCLUSION: The microleakage score at gingival margins is dependent on the interaction of the hard tissue removal tool and the adhesive system used. The self-etching adhesive system had a lower microleakage score at dentin margins for cavities prepared with Er:YAG and Er,Cr:YSGG than the etch-and-rinse two-step adhesive system.


Assuntos
Resinas Compostas , Colagem Dentária , Preparo da Cavidade Dentária/métodos , Infiltração Dentária , Restauração Dentária Permanente , Cimentos de Resina , Condicionamento Ácido do Dente , Animais , Bis-Fenol A-Glicidil Metacrilato , Bovinos , Preparo da Cavidade Dentária/instrumentação , Técnica Odontológica de Alta Rotação , Adaptação Marginal Dentária , Lasers de Estado Sólido , Metacrilatos , Distribuição Aleatória
14.
J Oral Implantol ; 33(4): 232-8, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17912965

RESUMO

The aim of this study was to evaluate the microbiota and surface of failed titanium dental implants from 4 manufacturers. Twelve mobile dental implants were retrieved from 10 smokers after 3 to 10 years of functional loading. Before implant removal, microbial samples were taken and evaluated using polymerase chain reaction. After implant removal, analyses of the failed implant surfaces were performed using scanning electron microscopy and energy-dispersive spectrometer x-ray. Periodontal pathogens such as Aggregactibacter actinomycetemcomitans, Campylobacter rectus, Eikenella corrodens, Fusobacterium nucleatum, Porphyromonas gingivalis, Prevotella intermedia, Tannerella forsythia, and Treponema denticola were detected in all implants in different proportions. Surface analysis showed varying degrees of surface roughness between the samples and the presence of proteinaceous material, appearing mainly as dark stains. Foreign carbon, oxygen, sodium, calcium, aluminum, and silicon elements were also found. Although no material-related causes of implant failure were detected, several periodontal pathogens were identified independently of the surface topography or manufacturer.


Assuntos
Implantes Dentários , Falha de Restauração Dentária , Bactérias Gram-Negativas/classificação , Fumar , Aggregatibacter actinomycetemcomitans/isolamento & purificação , Bacteroides/isolamento & purificação , Cálcio/análise , Campylobacter rectus/isolamento & purificação , Carbono/análise , Implantes Dentários/microbiologia , Materiais Dentários/química , Eikenella corrodens/isolamento & purificação , Microanálise por Sonda Eletrônica , Fusobacterium nucleatum/isolamento & purificação , Humanos , Microscopia Eletrônica de Varredura , Oxigênio/análise , Fósforo/análise , Porphyromonas gingivalis/isolamento & purificação , Prevotella intermedia/isolamento & purificação , Sódio/análise , Propriedades de Superfície , Titânio/química , Treponema denticola/isolamento & purificação
15.
Gen Dent ; 55(5): 416-9, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17899718

RESUMO

The argon laser is an alternative light source that can be used for the photopolymerization of resin-based dental materials and for tooth bleaching. The argon laser emits specific laser lines with wavelengths that correspond to the absorption peak of camphoroquinone, the initiator of polymerization for the adequate photocuring of resin composite. The collimated beam of the argon laser does not decrease with distance and an optical fiber has access to all cavity areas. In addition, the temperatures produced by an argon laser when curing resin-based materials and performing in-office tooth bleaching are significantly lower than those of conventional photocuring units. Argon is one of the three dental laser wavelengths that have been cleared by the FDA for tooth whitening. This article reviews the literature to examine the role that argon lasers can play in dental treatment.


Assuntos
Resinas Compostas/efeitos da radiação , Lasers , Clareamento Dental/métodos , Argônio , Equipamentos Odontológicos , Humanos , Transição de Fase , Clareamento Dental/instrumentação
16.
Photomed Laser Surg ; 35(10): 530-536, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28322603

RESUMO

OBJECTIVE: The objective of the study was to evaluate the microtensile bond strength (µTBS) of a composite resin to abraded or non-abraded bleached enamel after Er,Cr:YSGG laser irradiation and to observe the fracture patterns of the tested interfaces. MATERIALS AND METHODS: Two hundred twenty-eight bovine incisors were sectioned, resulting in 228 enamel blocks (7 × 4 × 4 mm3) that were divided into 12 groups (n = 19) according to the factors "adhesion" after bleaching (immediate adhesion; after 14 days; and a control group with adhesion on unbleached teeth); enamel "abrasion" (with or without abrasion simulating cavity preparation); and "laser" (with or without Er,Cr:YSGG laser irradiation). Bleached enamel groups were treated with 20% carbamide peroxide, 8 h/day for 21 days. Abrasion was performed with silicon carbide sandpaper. Specimens were restored with adhesive system and a composite resin (Adper Single Bond 2 and Z250; 3M ESPE). After 7 days, specimens were prepared by cutting into 1 mm beans to µTBS test performed in a universal testing machine. Fracture mode analysis was performed by using a stereoscopic loupe. The µTBS data were statistically analyzed by three-way analysis of variance with 95% confidence level and compared by running a Tukey post hoc test (α = 0.05). RESULTS: There was no statistically significant difference between triple interaction and double interactions among factors. There was no significant difference between the factors "adhesion," "abrasion," and "laser." Laser irradiation produced significantly lower bond strength values in irradiated groups compared with the non-irradiated ones. All groups had a high percentage of adhesive failures. CONCLUSIONS: Abrasion provided no benefit to bond strength of composite resins to bleached enamel. Er,Cr:YSGG (20 Hz, 0.5 W, 3.97 J/cm2) treatment reduced the bond strength of composite resins to enamel.


Assuntos
Resinas Compostas/efeitos da radiação , Colagem Dentária/métodos , Lasers de Estado Sólido/uso terapêutico , Terapia com Luz de Baixa Intensidade/métodos , Resistência à Tração/efeitos da radiação , Clareamento Dental/métodos , Análise de Variância , Animais , Bovinos , Resinas Compostas/química , Esmalte Dentário/efeitos da radiação , Técnicas In Vitro , Incisivo/efeitos da radiação , Sensibilidade e Especificidade
17.
Photomed Laser Surg ; 35(11): 639-646, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29099682

RESUMO

BACKGROUND: High power lasers have been suggested as a useful tool for dental caries and erosion prevention due to the increase of enamel acid resistance. OBJECTIVE: to evaluate the effect of Er,Cr:YSGG (erbium,chromium:yttrium, scandium, gallium, garnet) laser irradiation pulse frequency and power on enamel surface and acid erosion resistance. METHODS: By combining pulse frequency (5-75 Hz) and power settings (0.10-1.00 W), 20 irradiated groups and one nonirradiated control group were tested. A total of 63 bovine enamel blocks (n = 3/group) were prepared for surface hardness and roughness evaluation, performed in three phases: baseline, after irradiation, and after erosive challenge. Enamel blocks were irradiated with Er,Cr:YSGG laser with MZ8 tip (iPlus; Waterlase, Biolase, CA) for 30 sec according to experimental group and submitted. Erosive challenge consisted of four cycles alternating immersion in 0.01 M HCl (5 mL/mm2; 2 min; at 37°C) and immersion in artificial saliva for 3 h. Analysis of variance (three-way ANOVA), Tukey's test, and Pearson correlation were performed for the statistical analysis (p < 0.05). RESULTS: After irradiation, groups irradiated with pulse frequency of 10 and 15 Hz showed a decrease in surface hardness. After erosive challenge, 5 and 75 W groups showed increase in surface hardness; 0.25, 0.5, 0.75, and 1 W groups showed minor alterations in surface roughness. CONCLUSIONS: the irradiation of Er,Cr:YSGG laser with different parameters of power and pulse frequency settings may alter enamel surface and erosive resistance differently. Pulse frequency of 30 Hz and power of 0.50 W was considered the best parameter to prevent enamel acid erosion.


Assuntos
Cárie Dentária/prevenção & controle , Esmalte Dentário/efeitos da radiação , Lasers de Estado Sólido , Erosão Dentária/prevenção & controle , Animais , Bovinos , Testes de Dureza , Técnicas In Vitro , Propriedades de Superfície
18.
Photomed Laser Surg ; 35(10): 515-519, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28437191

RESUMO

OBJECTIVE: One of the limiting factors of employing laser radiation on dental therapies is the potential of causing thermal injuries to pulp tissues. The purpose of this study was to evaluate intra-chamber temperature increase on extracted human teeth exposed to 670 nm wavelength InGaAlP laser diode radiation. MATERIALS AND METHODS: In vitro intra-chamber temperature measurements of 12 standardized human teeth (incisors, canines, premolars, and molars; n = 3) were taken both before and after laser radiation. A type-K thermocouple fast-response thermocouple wire with a 0.5 mm diameter probe was inserted into the tooth pulp chamber (ICEL-Manaus-brand). The laser device Lasotronic-brand InGaAlP laser diode was used to irradiate tooth enamel, perpendicularly to the external surface for 30 sec, with power of levels of 340, 272, 204, 136, and 68 mW. The measurements were taken at three time points: 0, 30 sec, and 3 min after the laser irradiation. Measurements were repeated 24 h after removal and reinsertion of the probe in the pulp chamber. The temperature gradient (ΔT in °C) was calculated (ΔT = final temperature-initial temperature) for each group. Data of ΔT were statistically analyzed by two-way analysis of variance (ANOVA) at the 95% confidence level and compared by Tukey post hoc test (α = 0.05). RESULTS: ANOVA showed statistically significant differences to the interaction of factors (p < 0.05). The highest ΔT values obtained were observed to incisors with 340 mW, 272 mW; 204 mW of power (respectively 4.7°C, 4.2°C, and 3.1°C); and canines presented the lowest ΔT (0.8°C-0.3°C) with no influence of power output. CONCLUSIONS: Since the thermal increase was observed in this study, especially in incisors, attention should be paid to avoid pulpal damage.


Assuntos
Cavidade Pulpar/efeitos da radiação , Lasers Semicondutores , Terapia com Luz de Baixa Intensidade/métodos , Temperatura , Análise de Variância , Dente Pré-Molar/efeitos da radiação , Humanos , Técnicas In Vitro , Incisivo/efeitos da radiação
19.
Photomed Laser Surg ; 34(5): 194-9, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27058359

RESUMO

OBJECTIVE: This study investigated the effects of diode laser (gallium, aluminium, arsenide [GaAlAs]) irradiation with decontamination parameters on the temperature and roughness of yttrium-stabilized tetragonal zirconia polycrystal (Y-TZP), titanium (TI), and sandblasted large grit acid-etched titanium (SLA). MATERIALS AND METHODS: Three groups (n = 10) of standardized disks with 5 mm diameter and 2 mm thickness were produced with Y-TZP obtained from computer-aided design and computer-aided manufacturing (CAD-CAM), machined TI and SLA. The diode laser single application (808 nm, 20 sec, 1 W, 50 Hz, t on = 100 ms, t off = 100 ms, energy density = 28.29 J/cm(2)) was performed in contact mode, on each disk. The temperature was measured by a thermosensor attached to a digital thermometer fixed to the opposite irradiated surface. The temperature gradient (ΔT) was calculated (ΔT = final temperature - initial temperature) for each group. The parameters Ra (in µm) and Sa (in µm(2)) were measured by white light confocal laser microscopy to express the surface roughness. Data of ΔT was statistically analyzed by one way ANOVA at the 95% confidence level and compared by Tukey post-hoc test (α = 0.05). Roughness data was analyzed by t test. RESULTS: The diode laser irradiation presented the following results (ΔT value): Y-TZP = 10.3°C(B); TI = 38.6°C(A), and SLA = 26.7°C(A). The ΔT values ((°)C) of the titanium groups were higher than for the Y-TZP group. For both roughness parameters (Ra and Sa), data did not show statistical significant differences to "irradiation" factor (p > 0.05) to Y-TZP and SLA. The Ra results (in µm) were: Y-TZP (control) = 0.73 (0.55); Y-TZP (irradiated) = 0.45 (0.27); SLA (control) = 0.74 (0.23); and SLA (irradiated) = 0.99 (0.33). The Sa results (in µm(2)) were: Y-TZP (control) = 1.39 (1.05); Y-TZP (irradiated) = 0.73 (0.41); SLA (control) = 0.85 (0.08); and SLA (irradiated) = 1.27 (0.44). CONCLUSIONS: Diode laser irradiation for peri-implantitis treatment increased both zirconia and TI temperature without surface roughness alterations.


Assuntos
Descontaminação/métodos , Lasers Semicondutores , Peri-Implantite/prevenção & controle , Titânio/efeitos da radiação , Zircônio/efeitos da radiação , Condicionamento Ácido do Dente , Desenho Assistido por Computador , Propriedades de Superfície , Temperatura , Ítrio/química
20.
Photomed Laser Surg ; 23(5): 493-7, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16262580

RESUMO

OBJECTIVE: The aim of this work was to study one dentin-bonding system associated with posterior teeth restorative composite resin by means of tensile bond strength tests varying the technique of polymerization: visible light and argon laser. BACKGROUND DATA: Previous studies have demonstrated the ability of the argon laser to polymerize light-activated materials. METHODS: Sixty specimens were prepared by grinding the labial surface of bovine teeth embedded in acrylic resin. The dentin bonding system used was Single Bond (3M), which has a poliacenoic acid copolimer, associated with a posterior teeth restorative composite resin (Filtek P60, 3M). The bonding sites were treated according to the instruction of the manufacturers. The 60 teeth, duly embedded and ground, were assigned to four groups with 15 teeth each: group 1, the adhesive was light cured during 10 sec with visible light (Curing Light, 3M) with power density of 410 mW/cm2 and the composite resin was light cured during 20 sec with visible light; group 2, the adhesive and the composite resin were cured during 10 seconds with argon laser with 150 mW of power; group 3, the adhesive and the composite resin were cured during 10 sec with argon laser with 200 mW of power; and group 4, the adhesive and the composite resin were cured during 10 sec with argon laser with 250 mW of power. The composite resin was light cured in layers of 1 mm of thickness until the model of teflon with 3 mm in height was completely filled. RESULTS: The tensile bond strength test was performed in a Mini-Instron (model 4442) and the results for group 1 were 19.75 MPa (+/-4.65), group 2 were 16.09 MPa (+/-7.27), group 3 were 11.56 MPa (+/-4.50), and group 4 were 11.90 MPa (+/-5.78). CONCLUSIONS: One can conclude that the tensile bond strength promoted by the polymerization with visible light presented greater tensile bond strength than the polymerization with argon laser with 200 mW and 250 mW, but there was no significant difference between visible light and argon laser with 150 mW. There was no significant difference between argon laser with 150 mW and argon laser with 200 mW or 250 mW.


Assuntos
Colagem Dentária/métodos , Dentina/efeitos da radiação , Terapia a Laser , Ácidos Polimetacrílicos/farmacologia , Resistência à Tração , Dente , Animais , Argônio , Bovinos , Resinas Compostas/farmacologia , Colagem Dentária/instrumentação , Análise do Estresse Dentário , Modelos Animais , Valores de Referência , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA