RESUMO

PURPOSE: To determine whether perfusion computed tomography (CT)-derived vascular parameters-namely, blood flow, mean transit time (MTT), volume transfer constant (K(trans)), permeability-surface area product (PS), extracellular extravascular space volume, and vascular volume-correlate with the immunohistologic markers of angiogenesis in colorectal tumors. MATERIALS AND METHODS: This prospective study was approved by the Regional Ethics and Research and Development Committees. The perfusion CT protocol was incorporated in the staging CT after informed consent in 29 patients (14 men, 15 women; mean age, 70 years; age range, 55-94 years). The perfusion parameters were calculated over two regions of interest (ROIs), at the invasive and luminal site defined by two radiologists independently. Accurate representative data were captured manually by correcting for motion artifacts and were analyzed by using Matlab software. The vascular heterogeneity between ROIs was assessed by using the Wilcoxon signed rank test. Perfusion CT parameters were correlated with the microvessel density (MVD) count at both corresponding sites obtained by means of immunohistochemical staining of the selected histologic slide with factor VIII and CD105 antigens by using Spearmen rank coefficient. RESULTS: There was no statistically significant difference found between perfusion CT vascular parameters at the two ROIs by either of the radiologists. The Pearson coefficient for blood flow, MTT, K(trans), and PS at the two ROIs demonstrated good to moderate interobserver variability (for the two ROIs, 0.46 and 0.44; 0.67 and 0.64; 0.41 and 0.72; and 0.86 and 0.56, respectively). None of these parameters correlated with MVD count at the invasive or the luminal site for either of the two antigens. CONCLUSION: Perfusion CT measurements may measure vascularity of colorectal tumors, however, correlation with MVD, which is a morphologic measure, appears inappropriate. © RSNA, 2013.


Assuntos
Neoplasias Colorretais/irrigação sanguínea , Neoplasias Colorretais/diagnóstico por imagem , Neovascularização Patológica/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Artefatos , Meios de Contraste , Feminino , Humanos , Técnicas Imunoenzimáticas , Iohexol , Masculino , Microvasos , Pessoa de Meia-Idade , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador , Estatísticas não Paramétricas
2.
Curr Cardiol Rep ; 15(10): 402, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24022543

RESUMO

This review attempts to give practical advice for invasive electrophysiologists on personal radiation protection. Applying all measures of the "As low as reasonably achievable" ALARA concept should be a daily and indeed routine practice for all staff in the electrophysiology laboratory. A substantial number of technical options have been recently introduced which may enable the physician to lower the total radiation exposure significantly, but all require a substantial learning curve. Using these measures can arrive at very low or indeed close to ZERO fluoroscopy exposure even in complex ablation cases.


Assuntos
Técnicas Eletrofisiológicas Cardíacas/efeitos adversos , Exposição Ocupacional/prevenção & controle , Proteção Radiológica/métodos , Radiografia Intervencionista/efeitos adversos , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Fluoroscopia/efeitos adversos , Pessoal de Saúde , Humanos , Doses de Radiação , Radiografia Intervencionista/métodos , Gestão da Segurança/métodos
3.
Radiology ; 265(2): 426-36, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22891356

RESUMO

PURPOSE: To assess baseline reproducibility and compare performance of dynamic contrast material-enhanced (DCE) magnetic resonance (MR) imaging versus DCE computed tomographic (CT) measures of early vascular response in the same patients treated with cediranib (30 or 45 mg daily). MATERIALS AND METHODS: After institutional review board approval, written informed consent was obtained from 29 patients with advanced solid tumors who had lesions 3 cm or larger and in whom simultaneous imaging of an adjacent artery was possible. Two baseline DCE MR acquisitions and two baseline DCE CT acquisitions 7 days or fewer apart (within 14 days of starting treatment) and two posttreatment acquisitions with each modality at day 7 and 28 (±3 days) were obtained. Nonmodeled and modeled parameters were derived (measured arterial input function [AIF] for CT, population-based AIF for MR imaging; temporal sampling rate of 0.5 second for CT, 3-6 seconds for MR imaging). Baseline variability was assessed by using intra- and intersubject analysis of variance and Bland-Altman analysis; a paired t test assessed change from baseline to after treatment. RESULTS: The most reproducible parameters were DCE MR imaging enhancement fraction (baseline intrapatient coefficient of variation [CV]=8.6%), volume transfer constant (CV=13.9%), and integrated area under the contrast agent uptake curve at 60 seconds (CV=15.5%) and DCE CT positive enhancement integral (CV=16.0%). Blood plasma volume was highly variable and the only parameter with CV greater than 30%. Average reductions (percentage change) from baseline were consistently observed for all DCE MR imaging and DCE CT parameters at day 7 and 28 for both starting-dose groups (45 and 30 mg), except for DCE CT mean transit time. Percentage change from baseline for parameters reflecting blood flow and permeability were comparable, and reductions from baseline at day 7 were maintained at day 28. CONCLUSION: DCE MR imaging and DCE CT can depict vascular response to antiangiogenic agents with response evident at day 7. Improved reproducibility with MR imaging favors its use in trials with small patient numbers.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neoplasias/diagnóstico , Neoplasias/tratamento farmacológico , Neovascularização Patológica/diagnóstico , Neovascularização Patológica/tratamento farmacológico , Quinazolinas/administração & dosagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Inibidores da Angiogênese/administração & dosagem , Antineoplásicos/administração & dosagem , Meios de Contraste , Relação Dose-Resposta a Droga , Feminino , Gadolínio DTPA , Humanos , Iohexol , Masculino , Pessoa de Meia-Idade , Neoplasias/complicações , Neovascularização Patológica/etiologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
4.
Arch Cardiovasc Dis ; 112(1): 12-21, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30041863

RESUMO

BACKGROUND: Cardiac catheterization is the gold-standard modality for investigation of cardiovascular morphology before bidirectional cavopulmonary connection, but requires general anaesthesia and is associated with procedural risk. AIMS: To assess the diagnostic accuracy and safety of computed tomography in diagnosing great vessel stenosis/hypoplasia compared with cardiac catheterization and surgical findings. METHODS: Twenty-seven patients (10 after Norwood stage I) underwent computed tomography before surgery between January 2010 and June 2016; 16 of these patients also underwent cardiac catheterization. Proximal and distal pulmonary artery, aortic isthmus and descending aorta measurements, radiation dose and complications were compared via Bland-Altman analyses and correlation coefficients. RESULTS: The accuracy of computed tomography in detecting stenosis/hypoplasia of either pulmonary artery was 96.1% compared with surgical findings. For absolute vessel measurements and Z-scores, there was high correlation between computed tomography and angiography at catheterization (r=0.98 for both) and a low mean bias (0.71mm and 0.48; respectively). The magnitude of intertechnique differences observed for individual patients was low (95% of the values ranged between -0.9 and 2.3mm and between -0.7 and 1.7, respectively). Four patients (25%) experienced minor complications from cardiac catheterization, whereas there were no complications from computed tomography. Patients tended to receive a higher radiation dose with cardiac catheterization than with computed tomography, even after exclusion of interventional catheterization procedures (median 2.5 mSv [interquartile range 1.3 to 3.4 mSv] versus median 1.3 mSv [interquartile range 0.9 to 2.6 mSv], respectively; P=0.13). All computed tomography scans were performed without sedation. CONCLUSIONS: Computed tomography may replace cardiac catheterization in identification of great vessel stenosis/hypoplasia before bidirectional cavopulmonary connection when no intervention before surgery is required. Computed tomography carries lower morbidity, can be performed without sedation and may be associated with less radiation.


Assuntos
Aorta/diagnóstico por imagem , Aorta/cirurgia , Cateterismo Cardíaco , Angiografia por Tomografia Computadorizada , Técnica de Fontan , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia , Aorta/anormalidades , Aorta/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Angiografia por Tomografia Computadorizada/efeitos adversos , Constrição Patológica , Feminino , Cardiopatias Congênitas/fisiopatologia , Hemodinâmica , Humanos , Masculino , Valor Preditivo dos Testes , Artéria Pulmonar/anormalidades , Artéria Pulmonar/fisiopatologia , Doses de Radiação , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco
5.
J Cardiovasc Comput Tomogr ; 11(4): 268-273, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28532693

RESUMO

BACKGROUND: Little real-world radiation dose data exist for the majority of cardiovascular CT. Some data have been published for coronary CT angiography (coronary CTA) specifically, but they invariably arise from high-volume centres with access to the most recent technology. OBJECTIVE: The aim of this study was to document real-world radiation doses for coronary CTA in the United Kingdom, and to establish their relationship to clinical protocol selection, acquisition heart rate, and scanner technology. METHODS: A dose survey questionnaire was distributed to members of the British Society of Cardiovascular Imaging and other UK cardiac CT units. All participating centres collected data for consecutive coronary CTA cases over one month. The survey captured information about the exam conducted, patient demographics, pre-scan details such as beta-blocker administration, acquisition heart rate and scan technique, and post-scan dose indicators - series volumetric CT dose index (CTDIvol), series dose-length product (DLP), and exam DLP. RESULTS: Fifty centres provided data on a total of 1341 coronary CTA exams. Twenty-nine centres (58%) performed at least 20 coronary CTA scans in the collection period. The median BMI, acquisition heart rate and exam DLP were 28 kg/m2, 60 bpm and 209 mGycm respectively. The corresponding effective dose was estimated as 5.9 mSv using a conversion factor of 0.028 mSv/mGycm. There was no statistically significant difference in radiation dose between low and high-volume centres. Median exam DLP increased with the acquisition heart rate due to the selection of wider temporal windows. The highest exam DLPs were obtained on the older scanner technology. CONCLUSION: This study provides baseline data for benchmarking practice, optimizing radiation dose and improving service quality locally.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Doses de Radiação , Exposição à Radiação , Benchmarking , Índice de Massa Corporal , Angiografia por Tomografia Computadorizada/efeitos adversos , Angiografia por Tomografia Computadorizada/normas , Angiografia Coronária/efeitos adversos , Angiografia Coronária/normas , Doença da Artéria Coronariana/fisiopatologia , Pesquisas sobre Atenção à Saúde , Frequência Cardíaca , Hospitais com Alto Volume de Atendimentos , Hospitais com Baixo Volume de Atendimentos , Humanos , Valor Preditivo dos Testes , Estudos Prospectivos , Melhoria de Qualidade , Indicadores de Qualidade em Assistência à Saúde , Exposição à Radiação/efeitos adversos , Exposição à Radiação/normas , Fatores de Risco , Reino Unido
6.
Open Heart ; 4(2): e000626, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28878951

RESUMO

OBJECTIVE: High-pitch protocols are increasingly used in cardiovascular CT assessment for transcatheter aortic valve implantation (TAVI), but the impact on diagnostic image quality is not known. METHODS: We reviewed 95 consecutive TAVI studies: 44 (46%) high-pitch and 51 (54%) standard-pitch. Single high-pitch scans were performed regardless of heart rate. For standard-pitch acquisitions, a separate CT-aortogram and CT-coronary angiogram were performed with prospective gating, unless heart rate was ≥70 beats/min, when retrospective gating was used. The aortic root and coronary arteries were assessed for artefact (significant artefact=1; artefact not limiting diagnosis=2; no artefact=3). Aortic scans were considered diagnostic if the score was >1; the coronaries, if all three epicardial arteries scored >1. RESULTS: There was no significant difference in diagnostic image quality for either the aorta (artefact-free high-pitch: 31 (73%) scans vs standard-pitch: 40 (79%), p=0.340) or the coronary tree as a whole (10 (23%) vs 15 (29%), p=0.493). However, proximal coronary arteries were less well visualised using high-pitch acquisitions (16 (36%) vs 30 (59%), p=0.04). The median (IQR) radiation dose was significantly lower in the high-pitch cohort (dose-length product: 347 (318-476) vs 1227 (1150-1474) mGy cm, respectively, p<0.001), and the protocol required almost half the amount of contrast. CONCLUSIONS: The high-pitch protocol significantly reduces radiation and contrast doses and is non-inferior to standard-pitch acquisitions for aortic assessment. For aortic root assessment, the high-pitch protocol is recommended. However, if coronary assessment is critical, this should be followed by a conventional standard-pitch, low-dose, prospectively gated CT-coronary angiogram if the high-pitch scan is non-diagnostic.

7.
J Thorac Imaging ; 31(3): 177-82, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27007667

RESUMO

PURPOSE: We evaluated a high-pitch, non-electrocardiogram-gated cardiac computed tomographic protocol, designed to image both cardiac and extracardiac structures, including coronary arteries, in a neonatal population (less than 1 year old) that was referred for congenital heart disease assessment and compared it with an optimized standard-pitch protocol in an equivalent cohort. MATERIALS AND METHODS: Twenty-nine high-pitch scans were compared with 31 age-matched, sex-matched, and weight-matched standard-pitch, dosimetrically equivalent scans. The visualization and subjective quality of both cardiac and extracardiac structures were scored by consensus between 2 trained blinded observers. Image noise, signal-to-noise and contrast-to-noise ratios, and radiation doses were also compared. RESULTS: The high-pitch protocol better demonstrated the pulmonary veins (P=0.03) and all coronary segments (all P<0.05), except the distal right coronary artery (P=0.10), with no significant difference in the visualization of the remaining cardiac or extracardiac structures. Both contrast-to-noise and signal-to-noise ratios improved due to greater vessel opacity, with significantly fewer streak (P<0.01) and motion (P<0.01) artifacts. Image noise and computed tomographic dose index were comparable across the 2 techniques; however, the high-pitch acquisition resulted in a small, but statistically significant, increase in dose-length product [13.0 mGy.cm (9.0 to 17.3) vs. 11.0 mGy.cm (9.0 to 13.0), P=0.05] due to greater z-overscanning. CONCLUSIONS: In neonates, a high-pitch protocol improves coronary artery and pulmonary vein delineation compared with the standard-pitch protocol, allowing a more comprehensive assessment of cardiovascular anatomy while obviating the need for either patient sedation or heart rate control.


Assuntos
Angiografia Coronária/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Coração/diagnóstico por imagem , Humanos , Lactente , Recém-Nascido , Masculino , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído
8.
Med Phys ; 32(8): 2517-27, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16193782

RESUMO

A Monte Carlo based computer model has been developed for electron beam computed tomography (EBCT) to calculate organ and effective doses in a humanoid hermaphrodite phantom. The program has been validated by comparison with experimental measurements of the CT dose index in standard head and body CT dose phantoms; agreement to better than 8% has been found. The robustness of the model has been established by varying the input parameters. The amount of energy deposited at the 12:00 position of the standard body CT dose phantom is most susceptible to rotation angle, whereas that in the central region is strongly influenced by the beam quality. The program has been used to investigate the changes in organ absorbed doses arising from partial and full rotation about supine and prone subjects. Superficial organs experience the largest changes in absorbed dose with a change in subject orientation and for partial rotation. Effective doses for typical clinical scan protocols have been calculated and compared with values obtained using existing dosimetry techniques based on full rotation. Calculations which make use of Monte Carlo conversion factors for the scanner that best matches the EBCT dosimetric characteristics consistently overestimate the effective dose in supine subjects by typically 20%, and underestimate the effective dose in prone subjects by typically 13%. These factors can therefore be used to correct values obtained in this way. Empirical dosimetric techniques based on the dose-length product yield errors as great as 77%. This is due to the sensitivity of the dose length product to individual scan lengths. The magnitude of these errors is reduced if empirical dosimetric techniques based on the average absorbed dose in the irradiated volume (CTDIvol) are used. Therefore conversion factors specific to EBCT have been calculated to convert the CTDIvol to an effective dose.


Assuntos
Elétrons , Modelos Biológicos , Lesões por Radiação/etiologia , Lesões por Radiação/prevenção & controle , Proteção Radiológica/métodos , Radiometria/métodos , Medição de Risco/métodos , Tomografia Computadorizada por Raios X/efeitos adversos , Tomografia Computadorizada por Raios X/métodos , Carga Corporal (Radioterapia) , Simulação por Computador , Humanos , Imagens de Fantasmas , Doses de Radiação , Eficiência Biológica Relativa , Fatores de Risco
11.
Int J Radiat Oncol Biol Phys ; 74(1): 29-37, 2009 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-19036529

RESUMO

PURPOSE: Hypoxia in patients with head-and-neck cancer (HNC) is well established and known to cause radiation resistance and treatment failure in the management of HNC. This study examines the role of parameters derived from dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) and perfusion computed tomography (CT) as surrogate markers of intratumoral hypoxia, defined by using the exogenous marker of hypoxia pimonidazole and the endogenous marker carbonic anhydrase 9 (CA9). METHODS AND MATERIALS: Patients with HNC underwent preoperative DCE-MRI, perfusion CT, and pimonidazole infusion. Imaging parameters were correlated with pimonidazole and CA9 staining. The strength of correlations was tested by using a two-tailed Spearman's rank correlation coefficient. RESULTS: Twenty-three regions of interest were analyzed from the 7 patients who completed the DCE-MRI studies. A number of statistically significant correlations were seen between DCE-MRI parameters (volume transfer between blood plasma and extracellular extravascular space [EES], volume of EES, rate constant between EES and blood plasma, time at arrival of contrast inflow, time to peak, average gradient, and time to onset) and areas with a pimonidazole score of 4. In the case of CA9 staining, only a weak correlation was shown with wash-in rate. There were no significant correlations between perfusion CT parameters and pimonidazole staining or CA9 expression. CONCLUSION: Intratumoral hypoxia in patients with HNC may be predicted by using DCE-MRI; however, perfusion CT requires further investigation.


Assuntos
Hipóxia Celular , Neoplasias de Cabeça e Pescoço/metabolismo , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada Espiral/métodos , Idoso , Biomarcadores Tumorais/metabolismo , Anidrases Carbônicas/análise , Anidrases Carbônicas/metabolismo , Meios de Contraste/farmacocinética , Feminino , Neoplasias de Cabeça e Pescoço/irrigação sanguínea , Neoplasias de Cabeça e Pescoço/cirurgia , Humanos , Iohexol/farmacocinética , Masculino , Pessoa de Meia-Idade , Nitroimidazóis/farmacocinética , Tolerância a Radiação , Radiossensibilizantes/farmacocinética , Estatísticas não Paramétricas
SELEÇÃO DE REFERÊNCIAS