Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Card Fail ; 27(3): 364-367, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33242607

RESUMO

BACKGROUND: Balloon dilation and stenting of the atrial septum are techniques used to unload left heart cavities in acute or end-stage heart failure in children. However, they carry significant risks such as tamponade or device embolization. CASE PRESENTATION: We report the first case of a child with an end-stage mitochondrial cardiomyopathy on a venoarterial extracorporeal membrane oxygenator as a bridge to heart transplant where an atrial flow regulator device has been implanted. CONCLUSIONS: This case illustrates the feasibility and safety of atrial flow regulator implantation in this setting. This procedure allowed to wean inotropic support while awaiting heart transplantation.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca , Transplante de Coração , Criança , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Insuficiência Cardíaca/terapia , Humanos , Oxigenadores de Membrana
2.
Catheter Cardiovasc Interv ; 92(4): 732-740, 2018 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-29602262

RESUMO

OBJECTIVE: Thoracic endovascular aortic repair (TEVAR) has changed the management of aortic dissection by induced remodelling. Beyond reconstructing the true lumen, we describe the concept of False Lumen Intervention to promote Remodelling and Thrombosis (FLIRT) in both type A and B aortic dissection. METHODS: Between 2011 and 2017, 10 patients with aortic dissection (5 type A; 5 type B) underwent FLIRT using a combination of patent foramen ovale (PFO) or atrial septal defect (ASD) occluders, coils and glue. Patients were followed by computed tomography (CT) angiogram prior to, and 6 months following, discharge to evaluate false lumen (FL) thrombosis and aortic remodelling. Outcomes analyzed comprised successful device delivery, completeness of FL thrombosis and aortic remodelling, procedure related complications and mortality. RESULTS: FLIRT induced aortic remodelling in all cases of proximal dissection, with aortic shrinkage from 63.8 ± 7.5 pre-FLIRT, to 50.2 ± 6.6 mm (P = 0.057) and an increase in true lumen area from 5.8 ± 3.6 to 11.4 ± 2.5 cm2 (P = 0.006). In distal dissection (after previous TEVAR with residual FL flow), FLIRT successfully induced FL thrombosis in 4 of 5 cases at first attempt (1 case required additional coiling of the gutter between left subclavian artery and stent-graft for complete thrombosis). While maximal aortic diameter remained unchanged (55.6 ± 9.1 pre-FLIRT and 54.4 ± 13.7 mm at follow-up), true lumen area increased from 7.8 ± 2.3 pre-procedure, to 10.6 ± 1.5 cm2 at follow-up (P = 0.016), consistent with remodelling. CONCLUSION: Interventional FL management, using the FLIRT concept, is feasible in selected cases of aortic dissection, promotes FL thrombosis and induces successful remodelling.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Procedimentos Endovasculares , Trombose , Remodelação Vascular , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/mortalidade , Dissecção Aórtica/fisiopatologia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/fisiopatologia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Aneurisma da Aorta Torácica/fisiopatologia , Aortografia/métodos , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Trombose/diagnóstico por imagem , Fatores de Tempo , Resultado do Tratamento
3.
Aorta (Stamford) ; 10(1): 3-12, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35640581

RESUMO

Aortic pathologies in general require a multidisciplinary approach and decision-making to integrate elements of clinical acuity, vascular pathology, individual comorbidity, and risk assessment; thus, ideally it is a center with access to multiple imaging modalities and expertise in all treatment options. Besides classic open surgical options, endovascular procedures have been accepted for a variety of aortic pathologies. More recently, novel transcatheter interventions even to the proximal aorta have been introduced, particularly for patients unfit for open surgery. Nevertheless, the role of transesophageal echocardiography to guide percutaneous aortic interventions is not well established, notwithstanding the growing potential as an ancillary tool to guide the procedure and document success.

4.
Clin Case Rep ; 9(8): e04634, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34430006

RESUMO

Although Thoracic Endovascular Aortic Repair is usually applied to patients without connective tissue disorders, our case shows its potential for complicated type B aortic dissection in a Marfan patient as a feasible alternative to open redo surgery with good short-term outcomes.

5.
Eur Heart J Case Rep ; 5(1): ytaa485, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33554022

RESUMO

BACKGROUND: Aortic complications can happen during left ventricular assist devices (LVADs) insertion and its treatment remains challenging. Percutaneous aortic interventions can be an alternative to surgery in such high-risk cases. CASE SUMMARY: We present a patient with idiopatic dilated cardiomyopathy and advanced heart failure requiring LVAD insertion as a bridge to transplant, who developed an aortic pseudoaneurysm below the anastomosis of the LVAD tube. He was successfully treated with percutaneous coiling under contrast-enhanced transoesophageal echocardiography (TOE) guidance, reaching destination therapy (heart transplantation) a year later. DISCUSSION: Left ventricular assist devices provide haemodynamic support for patients with advanced heart failure waiting for heart transplantation. Although uncommon, aortic complications can happen as a result of LVAD insertion and be life-threatening. Percutaneous aortic interventions can be performed in such cases to promote thrombosis and remodelling of false lumen or aneurysmatic spaces, hence potentially reducing the risk of sudden death. Contrast-enhanced TOE can be easily and safely used to monitor the intervention in order to improve anatomic definition, guide positioning of wires and catheters and assess early results.

6.
Eur Heart J Case Rep ; 4(6): 1-7, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33442596

RESUMO

BACKGROUND: Corona Virus Disease 2019 (COVID-19) pneumonitis associated with severe respiratory failure carries a high mortality. Coagulopathy has emerged as a significant contributor to thrombotic complications. CASE SUMMARY: We describe two cases of severe COVID-19 pneumonitis refractory to conventional mechanical ventilation and proning position, transferred to our specialist centre for cardiorespiratory failure. Cross-sectional imaging demonstrated concurrent venous and aortic thrombosis with end-organ ischaemic changes. One patient received thrombolysis with a partial response. This could not be offered to the other patient due to a recent haemorrhagic event. Both patients died of multi-organ failure in the hospital. DISCUSSION: Concurrent aortic and venous thromboses are rare. This finding in COVID-19 cases, who were both critically ill patients, likely reflects the strongly thrombogenic nature of this illness which ultimately contributed to poor outcomes. The absence of deep vein thrombosis or a potential systemic source of embolism suggests in situ thrombosis. Further, the management of anticoagulation and thrombolysis is challenging in patients where an attendant bleeding risk exists.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA