1.
J Ultrasound Med ; 38(7): 1733-1738, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30426546

RESUMO

OBJECTIVES: To evaluate a new commercial image-processing technique (MicroPure; Toshiba America Medical Systems, Tustin, CA) for detection and characterization of breast microcalcifications in patients undergoing stereotactic or ultrasound-guided biopsies using mammography as the reference standard. METHODS: One hundred female patients, with a total of 104 lesions, scheduled for an image-guided biopsy of an area with breast microcalcifications (identified on a prior mammogram) underwent MicroPure examinations of the breast using an Aplio XG scanner (Toshiba America Medical Systems) with a broad-bandwidth linear array. MicroPure combines nonlinear imaging and speckle suppression to mark suspected calcifications as white spots in a blue overlay image. Four independent and blinded readers (2 radiologists and 2 physicists) analyzed 208 digital clips consisting of dual grayscale ultrasound and MicroPure imaging, counting the number of microcalcifications seen with MicroPure. The observers also assessed the level of suspicion on a qualitative, visual analog, 6-point scale from 0 (no findings) over 1 (benign) to 5 (malignant). RESULTS: The mean number of microcalcifications ± SD seen was 6.3 ± 3.5, whereas mammography saw 28.9 ± 24.6 (P = .66). When the MicroPure level of suspicion scores were compared with pathologic results using a receiver operating characteristic curve analysis, the areas under the curve ranged from 0.54 to 0.59. Nonetheless, malignant cases were seen to have significantly more microcalcifications than benign cases (mean number of microcalcifications, 6.9 ± 5.1 versus 5.3 ± 3.7; P = .02). CONCLUSIONS: MicroPure can be used to identify areas with breast microcalcifications but cannot effectively characterize such areas. Instead, MicroPure may represent a new imaging method for guiding a biopsy to areas of microcalcifications.


Assuntos
Doenças Mamárias/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Ultrassonografia Mamária/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Doenças Mamárias/patologia , Calcinose/patologia , Feminino , Humanos , Biópsia Guiada por Imagem , Mamografia , Pessoa de Meia-Idade , Estudos Prospectivos
2.
Radiology ; 262(2): 435-49, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22282182

RESUMO

PURPOSE: To determine whether adding shear-wave (SW) elastographic features could improve accuracy of ultrasonographic (US) assessment of breast masses. MATERIALS AND METHODS: From September 2008 to September 2010, 958 women consented to repeat standard breast US supplemented by quantitative SW elastographic examination in this prospective multicenter institutional review board-approved, HIPAA-compliant protocol. B-mode Breast Imaging Reporting and Data System (BI-RADS) features and assessments were recorded. SW elastographic evaluation (mean, maximum, and minimum elasticity of stiffest portion of mass and surrounding tissue; lesion-to-fat elasticity ratio; ratio of SW elastographic-to-B-mode lesion diameter or area; SW elastographic lesion shape and homogeneity) was performed. Qualitative color SW elastographic stiffness was assessed independently. Nine hundred thirty-nine masses were analyzable; 102 BI-RADS category 2 masses were assumed to be benign; reference standard was available for 837 category 3 or higher lesions. Considering BI-RADS category 4a or higher as test positive for malignancy, effect of SW elastographic features on area under the receiver operating characteristic curve (AUC), sensitivity, and specificity after reclassifying category 3 and 4a masses was determined. RESULTS: Median participant age was 50 years; 289 of 939 (30.8%) masses were malignant (median mass size, 12 mm). B-mode BI-RADS AUC was 0.950; eight of 303 (2.6%) BI-RADS category 3 masses, 18 of 193 (9.3%) category 4a lesions, 41 of 97 (42%) category 4b lesions, 42 of 57 (74%) category 4c lesions, and 180 of 187 (96.3%) category 5 lesions were malignant. By using visual color stiffness to selectively upgrade category 3 and lack of stiffness to downgrade category 4a masses, specificity improved from 61.1% (397 of 650) to 78.5% (510 of 650) (P<.001); AUC increased to 0.962 (P=.005). Oval shape on SW elastographic images and quantitative maximum elasticity of 80 kPa (5.2 m/sec) or less improved specificity (69.4% [451 of 650] and 77.4% [503 of 650], P<.001 for both), without significant improvement in sensitivity or AUC. CONCLUSION: Adding SW elastographic features to BI-RADS feature analysis improved specificity of breast US mass assessment without loss of sensitivity.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Aumento da Imagem/métodos , Ultrassonografia Mamária/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Europa (Continente) , Feminino , Humanos , Internacionalidade , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resistência ao Cisalhamento , Estados Unidos , Adulto Jovem
3.
Ultrasound Med Biol ; 44(6): 1286-1290, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29606493

RESUMO

The objective was to evaluate a commercial image processing technique (MicroPure, Canon Medical Systems, Tustin, CA, USA) for detection of microcalcifications in breast surgical specimens. Twenty women scheduled for surgical excision of an area with breast calcifications were enrolled, their surgical specimens underwent grayscale ultrasound (US) and MicroPure examination using an Aplio XG scanner (Canon). Four independent and blinded readers analyzed 54 US and 54 MicroPure digital clips to determine the number of calcifications and scored image quality and artifacts on a 10-point scale. All readers saw significantly more microcalcifications with MicroPure than with US, 14.0 ± 12.0 versus 3.0 ± 3.2 (p <0.0001). Three readers preferred MicroPure image quality over that of US (p <0.009) and vice versa for one reader (p = 0.003). Three readers saw fewer Cooper's ligament artifacts with MicroPure than with US (p <0.0001); one reader saw no significance difference between them (p = 0.58). In conclusion MicroPure identified more breast microcalcifications than grayscale US in ex vivo surgical breast specimens.


Assuntos
Doenças Mamárias/diagnóstico por imagem , Doenças Mamárias/patologia , Calcinose/diagnóstico por imagem , Calcinose/patologia , Ultrassonografia Mamária/métodos , Adulto , Idoso , Mama/diagnóstico por imagem , Mama/patologia , Feminino , Humanos , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos