Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Eur Radiol ; 26(6): 1582-9, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26385802

RESUMO

PURPOSE: Evaluation of feasibility and clinical performance of a tomosynthesis-guided vacuum-assisted breast biopsy (TVAB) system compared to Stereotaxy (SVAB). MATERIALS AND METHODS: All biopsies were performed on consecutive patients: 148 TVAB biopsies and 86 biopsies on different patients using SVAB. Evaluation criteria for each biopsy were technical feasibility, histopathology, procedure time, and complications. RESULTS: All 148 TVAB biopsies were technically successful, and gained the targeted groups of microcalcifications (100 %). In 1 of 86 SVAB procedures, it was not possible to gain the targeted microcalcifications (1 %), in 3 of 86 the needle had to be adjusted (4 %). All TVAB biopsies were performed without clinically relevant complications. Distortions were biopsied exclusively by TVAB, mean size 0.9 cm, p < 0.0001. Of the 24 distortions, 13 were cancer, 11 Radial Scars/ CSL. The mean procedure time for TVAB was 15.4 minutes (range 7-28 min), for SVAB 23 minutes (range 11-46 min), p < 0.0001. CONCLUSIONS: TVAB is able to biopsy small architectural distortions with high accuracy. TVAB is easily feasible and appears to have the same degree of clinical performance for diagnosing microcalcifications. The increased number of biopsied distortions by TVAB is presumably due to increased use of tomosynthesis and its diagnostic potential. KEY POINTS: • TVAB is easily feasible. • TVAB is able to target architectural distortions with high accuracy. • TVAB diagnoses microcalcifications with the same clinical performance as SVAB.


Assuntos
Neoplasias da Mama/patologia , Calcinose/patologia , Carcinoma Ductal de Mama/patologia , Carcinoma Intraductal não Infiltrante/patologia , Carcinoma Lobular/patologia , Fibroadenoma/patologia , Doença da Mama Fibrocística/patologia , Vácuo , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha/métodos , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Carcinoma Ductal de Mama/diagnóstico por imagem , Carcinoma Intraductal não Infiltrante/diagnóstico por imagem , Carcinoma Lobular/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Fibroadenoma/diagnóstico por imagem , Doença da Mama Fibrocística/diagnóstico por imagem , Humanos , Biópsia Guiada por Imagem/métodos , Imageamento Tridimensional , Mamografia/métodos , Pessoa de Meia-Idade
2.
AJR Am J Roentgenol ; 200(1): 226-31, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23255766

RESUMO

OBJECTIVE: The purpose of this study is to compare the diagnostic value of one-view digital breast tomosynthesis versus two-view full-field digital mammography (FFDM) alone, and versus a combined reading of both modalities. MATERIALS AND METHODS: The datasets of one-view digital breast tomosynthesis and two-view FFDM of abnormal mammograms in 144 consecutive women admitted for diagnostic workup with clinical signs and symptoms (n = 78) or recalled from screening (n = 66) were read alone and in a combined setting. The malignant or benign nature of the lesions was established by histologic analysis of biopsied lesions or by 12-16-month follow-up. RESULTS: Eighty-six of the 144 patients were found to have breast cancer. The BI-RADS categories for one-view digital breast tomosynthesis were significantly better than those for two-view FFDM (p < 0.001) and were equal to those of the combined reading in both women admitted for diagnostic workup and women recalled from screening. The sensitivity and negative predictive values of digital breast tomosynthesis were superior to those of FFDM in fatty and dense breasts overall and in women admitted for diagnostic workup and in women recalled from screening. Only 11% of digital breast tomosynthesis examinations required additional imaging, compared with 23% of FFDMs. CONCLUSION: In patients with abnormal mammograms, one-view digital breast tomosynthesis had better sensitivity and negative predictive value than did FFDM in patients with fatty and dense breasts. They also suggest that digital breast tomosynthesis would likely increase the predictive values if incorporated in routine screening.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Mamografia , Intensificação de Imagem Radiográfica , Feminino , Humanos , Imageamento Tridimensional , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA