Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Scand J Med Sci Sports ; 33(7): 1104-1115, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36811255

RESUMO

Predictors and mitigators of strain injuries have been studied in sprint-related sports. While the rate of axial strain, and thus running speed, may determine the site of muscle failure, muscle excitation seemingly offers protection against failure. It seems therefore plausible to ask whether running at different speeds changes the distribution of excitation within muscles. Technical limitations undermine, however, the possibility of addressing this issue in high-speed, ecological conditions. Here, we circumvent these limitations with a miniaturized, wireless, multi-channel amplifier, suited for collecting spatio-temporal data and high-density surface electromyograms (EMGs) during overground running. We segmented running cycles while 8 experienced sprinters ran at speeds close to (70% and 85%) and at (100%) their maximum, over an 80 m running track. Then, we assessed the effect of running speed on the distribution of excitation within biceps femoris (BF) and gastrocnemius medialis (GM). Statistical parametric mapping (SPM) revealed a significant effect of running speed on the amplitude of EMGs for both muscles, during late swing and early stance. Paired SPM revealed greater EMG amplitude when comparing 100% with 70% running speed for BF and GM. Regional differences in excitation were observed only for BF, however. As running speed increased from 70% to 100% of the maximum, a greater degree of excitation was observed at more proximal BF regions (from 2% to 10% of the thigh length) during late swing. We discuss how these results, in the context of the literature, support the protective role of pre-excitation against muscle failure, suggesting the site of BF muscle failure may depend on running speed.


Assuntos
Músculos Isquiossurais , Corrida , Humanos , Músculos Isquiossurais/fisiologia , Músculo Esquelético/fisiologia , Eletromiografia , Corrida/fisiologia
2.
Exp Brain Res ; 239(8): 2569-2581, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34191118

RESUMO

The purpose of this study is to investigate whether regional modulation of the ankle plantarflexors during standing was related to the recruitment of motor units associated with force direction. Fourteen participants performed a multi-directional leaning task in standing. Participants stood on a force platform and maintained their center of pressure in five different target directions. Motor unit firings were extracted by decomposition of high-density surface electromyograms recorded from the ankle plantarflexor muscles. The motor unit barycentre, defined as the weighted mean of the maximal average rectified values across columns and rows, was used to evaluate the medio-lateral and proximo-distal changes in the surface representation of single motor units across different leaning target directions. Using a motor unit tracking analysis, groups of motor units were identified as being common or unique across the target directions. The leaning directions had an effect on the spatial representations of motor units in the medial gastrocnemius and soleus (p < 0.05), but not in the lateral gastrocnemius (p > 0.05). Motor unit action potentials were represented in the medial and proximal aspects of the muscles during forward vs. lateral leans. Further analysis determined that the common motor units were found in similar spatial locations across the target directions, whereas newly recruited unique motor units were found in different spatial locations according to target direction (p < 0.05). The central nervous system may possess the ability to activate different groups of motor units according to task demands to meet the force-direction requirements of the leaning task.


Assuntos
Tornozelo , Postura , Articulação do Tornozelo , Eletromiografia , Humanos , Músculo Esquelético , Recrutamento Neurofisiológico , Posição Ortostática
3.
Artigo em Inglês | MEDLINE | ID: mdl-39074029

RESUMO

Tongue motor function is crucial in a wide range of basic activities and its impairment affects quality of life. The electrophysiological assessment of the tongue relies primarily on needle electromyography, which is limited by its invasiveness and inability to capture the concurrent activity of the different tongue muscles. This work aimed at developing an intraoral grid for high-density surface electromyography (HDsEMG) to non-invasively map the electrical excitation of tongue muscles. We developed a grid of 4×8 electrodes deposited over an adhesive 8- µ m thick polyurethane membrane. The testing protocol was conducted on 7 healthy participants and included functional tasks (vowels articulation and tongue movements) aimed at activating different regions of the tongue. The electrical stability of contact was assessed by measuring electrode-tongue impedances before and after the tasks. The spatial amplitude distribution of global EMG and single motor unit action potentials (MUAPs) was characterized. Electrode-tongue impedance magnitude showed no significant changes in the pre-post comparison ( 58±46 k Ω vs. 67±58 k Ω at 50Hz). Contact stability was confirmed by the quality of the signals that allowed to quantify spatiotemporal characteristics of muscle activation during the different tasks. The analysis of the spatial distribution of individual MUAPs amplitude showed that they were confined to relatively small areas on the tongue surface (range: 0.5cm2 -3.9cm [Formula: see text]. A variety of different spatiotemporal MUAP patterns, likely due to the presence of different muscle compartments with different fiber orientations, were observed. Our results demonstrate that the developed electrode grid enables HDsEMG acquisition from the tongue during functional tasks, thus opening new possibilities in tongue muscle assessment both at global and single motor unit level.


Assuntos
Eletromiografia , Desenho de Equipamento , Língua , Humanos , Língua/fisiologia , Eletromiografia/instrumentação , Eletromiografia/métodos , Masculino , Adulto , Feminino , Adulto Jovem , Voluntários Saudáveis , Impedância Elétrica , Músculo Esquelético/fisiologia , Contração Muscular/fisiologia , Eletrodos , Reprodutibilidade dos Testes , Potenciais de Ação/fisiologia , Poliuretanos
4.
J Neural Eng ; 20(4)2023 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-37437598

RESUMO

Objective.Ultrafast ultrasound (UUS) imaging has been used to detect intramuscular mechanical dynamics associated with single motor units (MUs). Detecting MUs from ultrasound sequences requires decomposing a velocity field into components, each consisting of an image and a signal. These components can be associated with putative MU activity or spurious movements (noise). The differentiation between putative MUs and noise has been accomplished by comparing the signals with MU firings obtained from needle electromyography (EMG). Here, we examined whether the repeatability of the images over brief time intervals can serve as a criterion for distinguishing putative MUs from noise in low-force isometric contractions.Approach.UUS images and high-density surface EMG (HDsEMG) were recorded simultaneously from 99 MUs in the biceps brachii of five healthy subjects. The MUs identified through HDsEMG decomposition were used as a reference to assess the outcomes of the ultrasound-based components. For each contraction, velocity sequences from the same eight-second ultrasound recording were separated into consecutive two-second epochs and decomposed. To evaluate the repeatability of components' images across epochs, we calculated the Jaccard similarity coefficient (JSC). JSC compares the similarity between two images providing values between 0 and 1. Finally, the association between the components and the MUs from HDsEMG was assessed.Main results.All the MU-matched components had JSC > 0.38, indicating they were repeatable and accounted for about one-third of the HDsEMG-detected MUs (1.8 ± 1.6 matches over 4.9 ± 1.8 MUs). The repeatable components (JSC > 0.38) represented 14% of the total components (6.5 ± 3.3 components). These findings align with our hypothesis that intra-sequence repeatability can differentiate putative MUs from noise and can be used for data reduction.Significance.This study provides the foundation for developing stand-alone methods to identify MU in UUS sequences and towards real-time imaging of MUs. These methods are relevant for studying muscle neuromechanics and designing novel neural interfaces.


Assuntos
Contração Isométrica , Músculo Esquelético , Humanos , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/fisiologia , Eletromiografia/métodos , Braço , Voluntários Saudáveis , Contração Muscular/fisiologia
5.
J Electromyogr Kinesiol ; 67: 102721, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36427373

RESUMO

Biofeedback based on electromyograms (EMGs) has been recently proposed to reduce exaggerated postural activity. Whether the effect of EMG biofeedback on the targeted muscles generalizes to - or is compensated by - other muscles is still an open question we address here. Fourteen young individuals were tested in three 60 s standing trials, without and with EMG-audio feedback: (i) collectively from soleus and medial gastrocnemius and (ii) from medial gastrocnemii. The Root Mean Square (RMS) of bipolar EMGs sampled from postural muscles bilaterally was computed to assess the degree of activity and postural sway was assessed from the center of pressure (CoP). In relation to standing at naturally, EMG-audio feedback from soleus and medial gastrocnemii decreased plantar flexors' activity (∼10 %) but at the cost of increased amplitude of tibialis anterior (∼5%) and vasti muscles (∼20 %) accompanied by a posterior shift of the mean CoP position. However, EMG-audio feedback from medial gastrocnemii reduced only plantar flexors' activity (∼5%) when compared to standing at naturally. Current results suggest the EMG biofeedback has the potential to reduce calf muscles' activity without loading other postural muscles especially when using medial gastrocnemii as feedback source, with implications on postural training aimed at assisting individuals in activating more efficiently postural muscles during standing.


Assuntos
Músculo Esquelético , Postura , Humanos , Músculo Esquelético/fisiologia , Postura/fisiologia , Equilíbrio Postural/fisiologia , Tornozelo/fisiologia , Eletromiografia , Extremidade Inferior/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA