Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
BMC Ophthalmol ; 24(1): 439, 2024 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-39375665

RESUMO

PURPOSE: To evaluate the repeatability and agreement of two swept-source optical coherence tomographers and Scheimpflug imaging for corneal curvature in healthy subjects to obtain data on the clinical application of a new device. METHODS: This prospective study was conducted in January and February 2021 with 100 healthy subjects at the Eye Hospital of Wenzhou Medical University. Simulated keratometry (Sim-K), posterior keratometry (Kp), total corneal power (TCP), and total corneal astigmatism (TCA) were measured with CASIA2, Anterion, and Pentacam. Within-subject standard deviation (Sw), repeatability coefficient (RC), coefficient of variation (CoV), and intraclass correlation coefficient (ICC) were used to assess inter-device repeatability. Bland-Altman analysis was performed to determine inter-device agreement. RESULTS: The three devices showed good repeatability for Sim-K, Kp, and TCP with all ICC > 0.980. Pentacam showed the highest repeatability (ICC ≥ 0.993; ICC ≥ 0.993) while the CASIA2 demonstrated the lowest repeatability (ICC: ≥ 0.986; ICC: ≥ 0.985) for Sim-K and TCP. Anterion and CASIA2 revealed better repeatability (ICC ≥ 0.998; ICC ≥ 0.981) for Kp than Pentacam (ICC ≥ 0.980). Pentacam and Anterion showed good repeatability for TCA (ICC: 0.935 and 0.916), whereas the CASIA2 showed moderate repeatability (ICC: 0.836). Three instruments demonstrated good agreement with the maximum absolute 95% Limits of agreement (LoA) of 1.00 D for Sim-K, Kp, and TCP. Wide LoA were found for TCA with the maximum absolute 95% LoA ≥ 0.66 D between the three devices. CONCLUSIONS: In healthy subjects, the three devices (Pentacam, Anterion and CASIA2) displayed comparable repeatability and accuracy for SimK, Kp, and TCP, and could be used interchangeably for these parameters. However, TCA measured by the three devices was not interchangeable. TRIAL REGISTRATION: Chinese Clinical Trial Registry Center (10/10/2020, ChiCTR2000038959).


Assuntos
Córnea , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Estudos Prospectivos , Masculino , Feminino , Reprodutibilidade dos Testes , Adulto , Córnea/diagnóstico por imagem , Adulto Jovem , Pessoa de Meia-Idade , Topografia da Córnea/instrumentação , Topografia da Córnea/métodos , Voluntários Saudáveis , Astigmatismo/diagnóstico , Fotografação/instrumentação , Fotografação/métodos
2.
Ophthalmology ; 129(9): 1014-1021, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35537532

RESUMO

PURPOSE: To explore whether there is a causal relationship between coffee consumption and primary open-angle glaucoma (POAG). DESIGN: Two-sample Mendelian randomization (MR). PARTICIPANTS: The single-nucleotide polymorphisms (SNPs) associated with coffee consumption (including phenotypes 1 and 2) were selected from a genome-wide association study (GWAS) involving 121 824 individuals of European descent. Coffee intake from the MRC-IEU UK Biobank was also used to identify instruments for coffee intake. Summary-level data for POAG were obtained from the largest publicly available meta-analyses involving 16 677 POAG cases and 199 580 controls of European descent. METHODS: The inverse variance-weighted (IVW) method was the main MR analysis, whereas weighted-median, weighted mode-based estimate (MBE), MR Pleiotropy RESidual Sum and Outlier (PRESSO) test, and MR-Egger regression were used for sensitivity analysis. MAIN OUTCOME MEASURES: Diagnosis of POAG. RESULTS: Three sets of instrumental variables were used to evaluate the causal association between coffee consumption and POAG risk. Results showed that genetically predicted higher coffee consumption phenotype 1 (cups/day) was significantly associated with higher risk of POAG (odds ratio [OR], 1.241; 95% confidence interval [CI], 1.041-1.480; P = 0.016). Genetically predicted higher coffee consumption phenotype 2 (high vs. no/low) was also significantly associated with higher risk of POAG (OR, 1.155; 95% CI, 1.038-1.284; P = 0.008, using the IVW method). Moreover, genetically predicted higher coffee intake from the MRC-IEU UK Biobank OpenGWAS was significantly associated with a higher risk of POAG (OR, 1.727; 95% CI, 1.230-2.425; P = 0.002, using the IVW method). Sensitivity analyses confirmed that the findings were robust to possible pleiotropy. CONCLUSIONS: These findings provide the genetic evidence that higher coffee consumption is associated with a higher risk of POAG. Given that coffee is widely consumed, our findings provide new insights into potential strategies to prevent and manage POAG.


Assuntos
Glaucoma de Ângulo Aberto , Análise da Randomização Mendeliana , Café/efeitos adversos , Estudo de Associação Genômica Ampla , Glaucoma de Ângulo Aberto/epidemiologia , Glaucoma de Ângulo Aberto/genética , Humanos , Polimorfismo de Nucleotídeo Único
3.
Graefes Arch Clin Exp Ophthalmol ; 260(9): 2905-2911, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35488908

RESUMO

PURPOSE: To assess the acquisition rate and agreement of axial length (AL) measurements with the OA-2000, Anterion, and IOLMaster 500 in cataractous patients. METHODS: In total, 298 eyes of 191 cataractous patients were enrolled and scanned with the three devices in random order. The success rate of AL measurements per device was calculated and a chi-square test was utilized to identify the differences in acquisition rate between the three devices. Logistic regression analysis was applied to evaluate the association of different cataract types and severity with the AL measurement acquisition rate. Bland-Altman plots were mapped to appraise the agreement of AL values. RESULTS: AL measurements were successfully achieved in 288 eyes (96.64%) with the OA-2000, in 282 eyes (94.30%) with the Anteiron, and in 246 eyes (82.55%) with the IOLMaster 500. Significant differences in the acquisition rate were found between either of the SS-OCT devices and IOLMaster 500 by chi-square analysis (P < 0.001). No significant difference was noted between OA-2000 and Anterion. Increasing severity of posterior subcapsular cataract was associated with a higher failure rate with the IOLMaster 500. Bland-Altman analysis identified good agreement between the three biometers with narrow 95% limits of agreement. CONCLUSIONS: The OA-2000 and Anterion showed similarly higher acquisition rate of AL measurements than IOLMaster 500 in cataractous patients. Good agreement for AL values was found between the three biometers in cataractous patients.


Assuntos
Comprimento Axial do Olho , Catarata , Câmara Anterior , Biometria , Humanos , Interferometria , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica
4.
Graefes Arch Clin Exp Ophthalmol ; 260(7): 2271-2281, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35171331

RESUMO

PURPOSE: To investigate the repeatability of Anterion and compare the agreement of ocular biometric measurements and predicted intraocular lens (IOL) powers with other three optical biometers. METHODS: Flat keratometry (Kf), steep keratometry (Ks), J0 and 45 vectors, central cornea thickness (CCT), anterior chamber depth (ACD), and axial length (AL) from the Anterion, IOLMaster 700, Lenstar LS 900, and OA-2000 were recorded. The IOL powers were calculated with the Hoffer Q, Holladay 1, SRK/T, and Haigis formulas. The repeatability was evaluated using the within-subject standard deviation (Sw), repeatability coefficient (RC), coefficient of variation (COV), and intraclass correlation coefficient (ICC). Inter-device agreement between the four biometers was assessed with the 95% limits of agreement. RESULTS: In total, 101 right eyes of 101 participants were enrolled. The Anterion showed good repeatability for all the included biometric parameters with all the CoV ≤ 0.30% and ICC ≥ 0.930 except for J45 with moderate repeatability (ICC was 0.849). Good agreement was found among the four devices for Kf, Ks, J0, J45, ACD, and AL. Generally, wide 95% LoA was found for the predicted IOL powers with the four IOL calculation formulas between the four devices. CONCLUSIONS: The Anterion showed good repeatability of biometric measurements for most parameters. Good agreement among the four optical biometers was achieved for all the parameters except for CCT and the predicted IOL power. The AL values exhibited the best repeatability with Anterion and the best agreement among the biometers in our study.


Assuntos
Comprimento Axial do Olho , Lentes Intraoculares , Câmara Anterior/anatomia & histologia , Câmara Anterior/diagnóstico por imagem , Comprimento Axial do Olho/anatomia & histologia , Biometria , Córnea/diagnóstico por imagem , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica
5.
BMC Musculoskelet Disord ; 20(1): 380, 2019 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-31421678

RESUMO

BACKGROUND: At present, bicortical pedicle screws (BPSs) are not used clinically because they carry the potential risk of damaging the prevertebral great vessels (PGVs). The authors observed the anatomical relationship between the PGVs and simulated BPSs at different transverse screw angles (TSAs), exploring the insertion method of the BPS. METHODS: Computed tomography angiography (CTA) images from 65 adults were collected. A total of 4-5 TSAs of the BPSs were simulated on the left and right sides of L1-L5 (L1-L3: 0°, 5°, 10°, 15°; L4-L5: 0°, 5°, 10°, 15°, 20°). There were three types of distances from the anterior vertebral cortex (AVC) to the PGVs (DAVC-PGV); DAVC-PGV < 0.50 cm, DAVC-PGV ≥ 0.50 cm, and DAVC-PGV↑; these distances represented close, distant, and noncontact PGV, respectively. RESULTS: The ratio of every type of PGV was calculated, and the appropriate TSA of the BPS was recommended. In L1, the recommended left TSA of the BPS was 0°, and the ratio of the close PGV was 7.69%, while the recommended right TSA was 0°-10°, and the ratio of the close PGV was 1.54-4.62%. In L2, the recommended left TSA of the BPS was 0° and the ratio of the close PGV was 1.54%, while the recommended right TSA was 0°-15° and the ratio of the close PGV was 3.08-9.23%. In L3, the recommended left TSA was 0°-5°, and the ratio of the close PGV was 1.54-4.62%. In L4, the recommended left TSA was 0°, and the ratio of the close PGV was 4.62%. BPS use was not recommended on the right side of either L3 or L4 or on the either side of L5. CONCLUSIONS: From the anatomical perspective of the PGVs, BPSs were not suitable for insertion into every lumbar vertebra. Furthermore, the recommended methods for inserting BPSs were different in L1-L4.


Assuntos
Vértebras Lombares/irrigação sanguínea , Parafusos Pediculares/efeitos adversos , Fusão Vertebral/métodos , Adulto , Idoso , Aorta Abdominal/anatomia & histologia , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/lesões , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Artéria Ilíaca/anatomia & histologia , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/lesões , Veia Ilíaca/anatomia & histologia , Veia Ilíaca/diagnóstico por imagem , Veia Ilíaca/lesões , Complicações Intraoperatórias/etiologia , Complicações Intraoperatórias/prevenção & controle , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Fusão Vertebral/efeitos adversos , Fusão Vertebral/instrumentação , Veia Cava Inferior/anatomia & histologia , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/lesões , Adulto Jovem
6.
Eur Respir J ; 48(1): 168-78, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27230438

RESUMO

Prospective population data on the incidence of tuberculosis (TB) infection has been sparsely reported in the global literature.A population-based prospective study was conducted in rural China to investigate the annual risk of TB infection, and its persistence using serial tuberculin skin tests (TSTs) and an interferon-γ release assay. In total, 13 580 eligible participants from four rural sites, identified as TST negative (<10 mm) or QuantiFERON-TB Gold In-Tube (QFT) (an interferon-γ release assay) negative from a baseline survey, were included in the first year's follow-up examination.The annual conversion rate of QFT among the study sites ranged between 2.1% and 4.9% (average 3.1%), and the incidence of TST conversion ranged between 6.0% and 31.1% (average 14.5%). During the second year's follow-up, infection persistence was investigated using 390 subjects with QFT conversions. Among them, 49.7% (164 out of 330) were found to be consistently QFT positive. Both the conversion and the persistence of QFT positivity were found to be significantly increased with increasing age.In conclusion, the annual TB infection rate was suggested to be ∼1.5% based on persistent positive results after QFT conversion in rural China. Therefore, infection control among those high-risk populations, including the elderly, should be prioritised for TB control in China.


Assuntos
Tuberculose Latente/diagnóstico , Tuberculose Latente/epidemiologia , Programas de Rastreamento/métodos , População Rural , Adolescente , Adulto , Distribuição por Idade , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , China/epidemiologia , Feminino , Humanos , Incidência , Testes de Liberação de Interferon-gama , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco , Distribuição por Sexo , Teste Tuberculínico , Adulto Jovem
7.
PLoS Med ; 12(9): e1001876, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26372470

RESUMO

BACKGROUND: Mobile text messaging and medication monitors (medication monitor boxes) have the potential to improve adherence to tuberculosis (TB) treatment and reduce the need for directly observed treatment (DOT), but to our knowledge they have not been properly evaluated in TB patients. We assessed the effectiveness of text messaging and medication monitors to improve medication adherence in TB patients. METHODS AND FINDINGS: In a pragmatic cluster-randomised trial, 36 districts/counties (each with at least 300 active pulmonary TB patients registered in 2009) within the provinces of Heilongjiang, Jiangsu, Hunan, and Chongqing, China, were randomised using stratification and restriction to one of four case-management approaches in which patients received reminders via text messages, a medication monitor, combined, or neither (control). Patients in the intervention arms received reminders to take their drugs and reminders for monthly follow-up visits, and the managing doctor was recommended to switch patients with adherence problems to more intensive management or DOT. In all arms, patients took medications out of a medication monitor box, which recorded when the box was opened, but the box gave reminders only in the medication monitor and combined arms. Patients were followed up for 6 mo. The primary endpoint was the percentage of patient-months on TB treatment where at least 20% of doses were missed as measured by pill count and failure to open the medication monitor box. Secondary endpoints included additional adherence and standard treatment outcome measures. Interventions were not masked to study staff and patients. From 1 June 2011 to 7 March 2012, 4,292 new pulmonary TB patients were enrolled across the 36 clusters. A total of 119 patients (by arm: 33 control, 33 text messaging, 23 medication monitor, 30 combined) withdrew from the study in the first month because they were reassessed as not having TB by their managing doctor (61 patients) or were switched to a different treatment model because of hospitalisation or travel (58 patients), leaving 4,173 TB patients (by arm: 1,104 control, 1,008 text messaging, 997 medication monitor, 1,064 combined). The cluster geometric mean of the percentage of patient-months on TB treatment where at least 20% of doses were missed was 29.9% in the control arm; in comparison, this percentage was 27.3% in the text messaging arm (adjusted mean ratio [aMR] 0.94, 95% CI 0.71, 1.24), 17.0% in the medication monitor arm (aMR 0.58, 95% CI 0.42, 0.79), and 13.9% in the combined arm (aMR 0.49, 95% CI 0.27, 0.88). Patient loss to follow-up was lower in the text messaging arm than the control arm (aMR 0.42, 95% CI 0.18-0.98). Equipment malfunction or operation error was reported in all study arms. Analyses separating patients with and without medication monitor problems did not change the results. Initiation of intensive management was underutilised. CONCLUSIONS: This study is the first to our knowledge to utilise a randomised trial design to demonstrate the effectiveness of a medication monitor to improve medication adherence in TB patients. Reminders from medication monitors improved medication adherence in TB patients, but text messaging reminders did not. In a setting such as China where universal use of DOT is not feasible, innovative approaches to support patients in adhering to TB treatment, such as this, are needed. TRIAL REGISTRATION: Current Controlled Trials, ISRCTN46846388.


Assuntos
Antituberculosos/administração & dosagem , Adesão à Medicação , Sistemas de Alerta , Envio de Mensagens de Texto , Tuberculose Pulmonar/tratamento farmacológico , China , Feminino , Humanos , Masculino
8.
Lancet ; 383(9934): 2057-2064, 2014 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-24650955

RESUMO

BACKGROUND: China scaled up a tuberculosis control programme (based on the directly observed treatment, short-course [DOTS] strategy) to cover half the population during the 1990s, and to the entire population after 2000. We assessed the effect of the programme. METHODS: In this longitudinal analysis, we compared data from three national tuberculosis prevalence surveys done in 1990, 2000, and 2010. The 2010 survey screened 252,940 eligible individuals aged 15 years and older at 176 investigation points, chosen by stratified random sampling from all 31 mainland provinces. All individuals had chest radiographs taken. Those with abnormal radiographs, persistent cough, or both, were classified as having suspected tuberculosis. Tuberculosis was diagnosed by chest radiograph, sputum-smear microscopy, and culture. Trained staff interviewed each patient with tuberculosis. The 1990 and 2000 surveys were reanalysed and compared with the 2010 survey. FINDINGS: From 1990 to 2010, the prevalence of smear-positive tuberculosis decreased from 170 cases (95% CI 166-174) to 59 cases (49-72) per 100,000 population. During the 1990s, smear-positive prevalence fell only in the provinces with the DOTS programme; after 2000, prevalence decreased in all provinces. The percentage reduction in smear-positive prevalence was greater for the decade after 2000 than the decade before (57% vs 19%; p<0.0001). 70% of the total reduction in smear-positive prevalence (78 of 111 cases per 100,000 population) occurred after 2000. Of these cases, 68 (87%) were in known cases-ie, cases diagnosed with tuberculosis before the survey. Of the known cases, the proportion treated by the public health system (using the DOTS strategy) increased from 59 (15%) of 370 cases in 2000 to 79 (66%) of 123 cases in 2010, contributing to reduced proportions of treatment default (from 163 [43%] of 370 cases to 35 [22%] of 123 cases) and retreatment cases (from 312 [84%] of 374 cases to 48 [31%] of 137 cases; both p<0.0001). INTERPRETATION: In 20 years, China more than halved its tuberculosis prevalence. Marked improvement in tuberculosis treatment, driven by a major shift in treatment from hospitals to the public health centres (that implemented the DOTS strategy) was largely responsible for this epidemiological effect. FUNDING: Chinese Ministry of Health.


Assuntos
Tuberculose/epidemiologia , Adolescente , Adulto , Distribuição por Idade , Idoso , Algoritmos , China/epidemiologia , Feminino , Programas Governamentais/organização & administração , Inquéritos Epidemiológicos , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Mycobacterium tuberculosis/isolamento & purificação , Prevalência , Distribuição por Sexo , Escarro/microbiologia , Tuberculose/diagnóstico , Tuberculose/prevenção & controle , Tuberculose Pulmonar/diagnóstico , Tuberculose Pulmonar/epidemiologia , Tuberculose Pulmonar/prevenção & controle , Adulto Jovem
9.
BMC Infect Dis ; 14: 64, 2014 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-24502559

RESUMO

BACKGROUND: In the context of decreasing tuberculosis prevalence in China, we examined the effectiveness of screening household contacts of tuberculosis patients. METHODS: A tuberculosis survey was conducted in 2008. All 3,355 household contacts of notified tuberculosis cases were examined with a questionnaire interview, chest X-ray and three sputum smear tests. The effectiveness was examined by comparing the prevalence of pulmonary tuberculosis in household contacts with or without presenting clinical symptoms against the respective notification rates. Regression models were used to evaluate the factors associated with pulmonary tuberculosis. RESULTS: Of the 3,355 household contacts, 92 members (2.7%) had pulmonary tuberculosis, among which 46 cases were asymptomatic. The prevalence of pulmonary tuberculosis and smear positive cases in household contacts without symptoms were 20 and 7 times higher than the notification rates in 2008, while those in household contacts with symptoms were 247 and 108 times higher than notification rates, respectively. The patients detected were mainly Index Cases' spouses, sisters/brothers and those who were in contact with female Index Cases. CONCLUSIONS: The present study provides convincing evidence that household contacts of notified tuberculosis cases are at higher risk of developing tuberculosis. Routine screening for household contacts without any symptoms is recommended for sustained tuberculosis control in China as well as in the world.


Assuntos
Busca de Comunicante , Tuberculose Pulmonar/epidemiologia , Tuberculose Pulmonar/transmissão , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , China/epidemiologia , Estudos Transversais , Características da Família , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Prevalência , Escarro/microbiologia , Inquéritos e Questionários , Tuberculose Pulmonar/diagnóstico , Adulto Jovem
10.
J Huazhong Univ Sci Technolog Med Sci ; 34(6): 907-911, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25480589

RESUMO

Anterior lumbar interbody fusion (ALIF) followed by posterior pedicle screw fixation (PSF) in a second procedure is mostly used to implement lumbar spine fusion. ALIF followed by anterior lumbar screw-plate has a lot of advantages, but its biomechanical stability requires confirmation. This study evaluated the biomechanical stability of a novel anterior lumbar locked screw-plate (ALLSP) by comparison with posterior lumbar PSF. Twelve fresh human cadaveric lumbar specimens (L4-L5) were assigned to four groups: ALIF+PSF group, ALIF+ALLSP (both fixed) group, ALIF group and an untreated control (both non-fixed) group. The first three groups received implantation of a rectangular titanium cage. Tests under axial compression, flexion, extension, lateral bending, or rotation showed that the fixed groups had significantly stronger stability than the non-fixed groups (P=0.000 for all). The ALIF+ALLSP group had significantly greater axial stiffness under applied axial compression and significantly less angular displacement under rotational forces than the ALIF+PSF group. The angular displacement of the ALIF+ALLSP group was less under flexion than that of the ALIF+PSF, and the angular displacement under lateral bending and extension was greater, but these differences were not statistically significant. In summary, the ALLSP conforms to the anterior lumbar spine and has good biomechanical stability. It is a reliable choice for enhancing the stability of ALIF.


Assuntos
Placas Ósseas , Parafusos Ósseos , Vértebras Lombares/fisiopatologia , Teste de Materiais , Adulto , Feminino , Humanos , Vértebras Lombares/patologia , Masculino
11.
China CDC Wkly ; 6(35): 896-900, 2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39233996

RESUMO

Introduction: Newer skin tests, including the ESAT6-CFP10 (EC) skin test, were recommended for diagnosing Mycobacterium tuberculosis (M. tb) infection. However, no data exist assessing the diagnostic performance of the EC skin test among foreign students with different skin tones. Methods: A cohort study at Nanjing Medical University screened incoming foreign freshmen. The EC skin test was used to assess for M. tb infection, and results were read at 24, 48, 72, and 96-hours post-administration. Results: Among 96 participants, M. tb infection rates at 24, 48, 72, and 96-hours post-injection were 3.13%, 7.29%, 13.54%, and 9.38%, respectively. While infection rates were lower among individuals with darker skin tones, the difference was not statistically significant (P=0.186), and variations were consistent across different measurement times. Trajectory analysis revealed 5.3% in the continuous-increasing group, 86.5% in the low-stable group, and 5.2% in the elevated-decreasing group. Notably, participants in the elevated-decreasing group had lighter skin tones, with trajectory patterns consistent across different skin colors. Discussion: The EC skin test is safe, and redness diameter is a more reliable indicator than induration. Results should be collected within 48 to 72 hours, with verification at 72 hours crucial if initial results are negative. Importantly, skin color does not affect EC skin test outcomes.

12.
J Refract Surg ; 39(1): 48-55, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36630430

RESUMO

PURPOSE: To investigate refractive prediction accuracy with the OA-2000 (Tomey), Anterion (Heidelberg Engineering), and IOLMaster 500 (Carl Zeiss Meditec AG) in patients with cataract. METHODS: Patients with cataract referred for phacoemulsification were enrolled and scanned with the OA-2000, Anterion, and IOLMaster 500 in random order. The success rate of axial length (AL) measurements per device was calculated and a chi-square test was used to identify the differences in acquisition rate between the three devices. The Bland-Altman method was used to appraise the agreement of biometric parameters between the three devices. Four different formulas (Barrett Universal II [BUII], Haigis, Holladay 1, and SRK/T) were included in the study. The parameters of refractive prediction accuracy comprised predictive error (PE), absolute PE (AE), and percentages of eyes with a PE within ±0.50, ±0.75, and ±1.00 diopters (D). RESULTS: The acquisition rates of AL measurements with the OA-2000 and Anterion were 97.35% and 94.70%, respectively (chi-square = 3.82, P > .05). A significantly lower acquisition rate of 84.82% was obtained with the IOLMaster 500 compared with the other two devices (P < .05). Bland-Altman analysis identified good agreement between the three biometers with narrow 95% limits of agreement for flat and steep keratometry (K1 and K2), anterior chamber depth (ACD), and AL. For PE, only the differences between the Anterion and IOLMaster 500 with the Barrett UII and Haigis formulas were statistically significant (P < .05). The three devices revealed no statistically significant differences in MAE, MedAE, and the proportion of eyes with a PE within ±0.50, ±0.75, and ±1.00 D (P > .05). CONCLUSIONS: The OA-2000 and Anterion showed a similarly higher acquisition rate of AL measurements than the IOLMaster 500 in patients with cataract. Good agreement for K1, K2, ACD, and AL was found between the three biometers. Regarding refractive prediction accuracy, the Anterion did not significantly outperform both the OA-2000 and IOLMaster 500. [J Refract Surg. 2023;39(1):48-55.].


Assuntos
Extração de Catarata , Catarata , Lentes Intraoculares , Dispositivos Ópticos , Facoemulsificação , Humanos , Refração Ocular , Catarata/diagnóstico , Facoemulsificação/métodos , Biometria/métodos , Óptica e Fotônica , Comprimento Axial do Olho , Estudos Retrospectivos
13.
Int J Biol Macromol ; 253(Pt 7): 127463, 2023 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-37852397

RESUMO

Variations in the structure and activities of polysaccharides from Tetrastigma hemsleyanum Diels et Gilg fermented by Sanghuangporus sanghuang fungi were investigated. Compare with the unfermented polysaccharide (THDP2), the major monosaccharide composition and molecular weight of polysaccharide after fermentation (F-THDP2) altered dramatically, which caused galactose-induced conversion from glucose and one-third of molecular weight. F-THDP2 had a molecular weight of 1.23 × 104 Da. Moreover, the glycosidic linkage of F-THDP2 varied significantly, a 1, 2-linked α-d-Galp and 1, 2-linked α-d-Manp backbone was established in F-THDP2, which differed from that of 1, 4-linked α-d-Glcp and 1, 4-linked ß-d-Galp in THDP2. In addition, F-THDP2 showed a more flexible chain conformation than that of THDP2 in aqueous solution. Strikingly, F-THDP2 exhibited superior inhibitory effects on HeLa cells via Fas/FasL-mediated Caspase-3 signaling pathways than that of the original polysaccharide. These variations in both structure and biological activities indicated that fermentation-mediated modification by Sanghuangporus sanghuang might a promising novel method for the effective conversion of starch and other polysaccharides from Tetrastigma hemsleyanum Diels et Gilg into highly bioactive biomacromolecules, which could be developed as a potential technology for use in the food industry.


Assuntos
Polissacarídeos , Vitaceae , Humanos , Células HeLa , Fermentação , Polissacarídeos/farmacologia , Polissacarídeos/química , Vitaceae/química
14.
BMC Public Health ; 12: 454, 2012 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-22712786

RESUMO

BACKGROUND: Data on effect of regular liver function monitoring during anti-TB treatment is limited in China. This study aimed to evaluate the effects of scheduled liver function monitoring on identification of asymptomatic liver damage and anti-TB treatment outcomes during anti-TB treatment. METHODS: A retrospective analysis was performed based on a national-level cohort study. A total of 273 patients developing liver dysfunction were divided into two groups, 111 patients who were diagnosed through scheduled liver function test within two months after initiation of anti-TB treatment formed scheduled monitoring group, others who were diagnosed due to developing symptoms formed passive detection group (n = 162). The two groups were compared through clinical features, prognosis of liver dysfunction and impact on anti-TB treatment using propensity score weighting analysis. RESULTS: 33.3% of 273 patients did not have any clinical symptoms, including 8 with severe hepatotoxicity. 1.8% in scheduled monitoring group and 11.1% in passive detection group required hospitalization (P = 0.004). Regarding the prognosis of liver dysfunction, most patients recovered, no death happened in scheduled monitoring group while 3 died in passive detection group. In terms of impact on anti-TB treatment, 35.1% in scheduled monitoring group and 56.8% in passive detection group changed their anti-TB treatment (P = 0.001). CONCLUSIONS: Scheduled monitoring is effective in identifying asymptomatic liver damage, reducing hospitalization rate and improving compliance of anti-TB treatment.


Assuntos
Antituberculosos/efeitos adversos , Doença Hepática Induzida por Substâncias e Drogas/diagnóstico , Doença Hepática Induzida por Substâncias e Drogas/etiologia , Monitoramento de Medicamentos , Testes de Função Hepática , Fígado/efeitos dos fármacos , Tuberculose/tratamento farmacológico , Adulto , Idoso , Antituberculosos/uso terapêutico , Criança , China , Estudos de Coortes , Feminino , Hospitalização/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Análise de Regressão , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença
15.
Zhonghua Yan Ke Za Zhi ; 48(11): 1005-10, 2012 Nov.
Artigo em Chinês | MEDLINE | ID: mdl-23302275

RESUMO

OBJECTIVE: To evaluate the precision of Intraocular Lens (IOL) power calculation using a new optical low-coherence reflectometry biometer (Lenstar) and compare the results with those obtained with IOLMaster. METHODS: It was a prospective controlled study. Biometry measurements in 157 eyes of 98 cataract patients were performed by the same examiner with Lenstar and IOLMaster. Axial length (AL), corneal keratometry readings (Km), and anterior chamber depth (ACD) were obtained. Correlation and differences of biometry measurements obtained with two biometers were made. Intraocular Lens power were calculated using 4 formulas and the corresponding IOL constants, the target was emmetropia. Then statistical analysis was proceeded. RESULTS: Axial length were (23.65 ± 1.17) mm and (23.65 ± 1.16) mm respectively, Km (44.15 ± 1.58) D and (44.17 ± 1.58) D respectively by Lenstar and IOLMaster and no statistical differences were found (P > 0.05). ACD were (3.09 ± 0.41) mm and (3.05 ± 0.41) mm respectively by Lenstar and IOLMaster and there was statistical difference between them (P = 0.001). All biometry measurements showed good linear correlation (r > 0.9, P < 0.001). IOL power calculations with biometry values between Lenstar and IOLMaster using the 4 formulas showed good agreement. The least difference was obtained with formula SRK/T and the most with formula Haigis. CONCLUSIONS: Lenstar can provide precise and noncontact biometry measurements easily and safely, which are welcome by patients. Providing precise and reliable biometry measurements of cataract patients for Intraocular Lens power calculation, it shows good agreement with IOLMaster and the two biometers can be interchanged.


Assuntos
Catarata/diagnóstico por imagem , Catarata/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Câmara Anterior , Biometria , Feminino , Humanos , Lentes Intraoculares , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiografia , Tomografia de Coerência Óptica , Testes Visuais
16.
J Glaucoma ; 31(7): 602-608, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35763682

RESUMO

PURPOSE: The aim was to evaluate the repeatability and agreement of two swept-source optical coherence tomographers for anterior segment parameters in healthy subjects. PATIENTS AND METHODS: Automated mark of scleral spur and angle recess for the CASIA2 and manual mark of scleral spur and angle recess for the Anterion were performed, and then the measurement values of the related parameters were automatically generated. Subjects with pupil diameter (PD) differing by <15% between the 2 devices were included. PD, lens vault (LV), anterior chamber depth (ACD), angle to angle distance (ATA), anterior chamber width (ACW), anterior chamber angle (ACA), angle opening distance (AOD), and trabecular iris space area (TISA) were measured in the horizontal images with both CASIA2 and Anterion. Intraclass correlation coefficient (ICC) was used to evaluate intradevice repeatability. Bland-Altman plots were performed to assess the agreement between the 2 devices. RESULTS: Thirty-five right eyes of 35 subjects were included with a mean age of 25.60±3.00 years. The CASIA2 showed moderate to good intradevice repeatability (ICCs ranged from 0.786 to 0.989) whereas the Anterion showed good intradevice repeatability (ICCs ranged from 0.921 to 0.998) for anterior segment parameters. Compared with the CASIA2, the Anterion offered larger values of ACA500/750, AOD500/750, and TISA500/750 but smaller values of PD, LV, ACD, ATA, and ACW. Good agreement for PD, ACD, ATA, and ACW was detected with 95% limits of agreement of -1.02 to 1.02 mm, -0.11 to 0.14 mm, -0.17 to 0.19 mm, -0.13 to 0.28 mm, respectively. Poor agreement for LV, ACA500/750, AOD500/750, and TISA500/750 was achieved with the 2 devices. CONCLUSIONS: Anterion outperformed CASIA2 on intradevice repeatability. While agreement was noted for some parameters using manual Anterion and automated CASIA2 approaches, poor agreement of LV and angle parameters indicates that measurements from these optical coherence tomography devices should not be considered interchangeable.


Assuntos
Segmento Anterior do Olho , Pressão Intraocular , Adulto , Câmara Anterior/diagnóstico por imagem , Segmento Anterior do Olho/diagnóstico por imagem , Humanos , Iris/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Adulto Jovem
18.
Medicine (Baltimore) ; 100(10): e25005, 2021 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-33725880

RESUMO

ABSTRACT: The role of thoracic CT (computerized tomography) in monitoring disease course of COVID-19 is controversial. The purpose of this study is to investigate the risk factors and predictive value of deterioration on repeatedly performed CT scan during hospitalization.All COVID-19 patients treated in our isolation ward, from January 22, 2020 to February 7, 2020, were reviewed. Patients included were categorized into RD (Radiological Deterioration) group or NRD (No Radiological Deterioration) group according to the manifestation on the CT routinely performed during the hospitalization. All clinical data and CT images were analyzed.Forty three patients were included in our study. All are moderate cases with at least 4 CT scans each. Eighteen (42.9%) patients had radiological deteriorations which were all identified in CT2 (the first CT after admission). Patients in RD group had lower leukocyte count (P = .003), lymphocyte count (P = .030), and higher prevalence (P = .012) of elevated C-reactive protein (CRP) at admission. NRD patients had a lower prevalence of reticulations (P = .034) on baseline CT (CT1, performed within 2 days before admission) and a longer duration between symptom onset and the time of CT2 (P < .01). There was no significant difference in hospital stay or fibrotic change on CT4 (follow-up CT scan performed 4 weeks after discharge) between 2 groups. Shorter duration between symptom onset and CT2 time (odds ratio [OR], 0.436; 95% confidence interval: 0.233-0.816; P < .01) and lower leukocyte count in baseline evaluation (OR, 0.316; 95% CI: 0.116-0.859; P < .05) were associated with increased odds of radiological deterioration on CT image during hospitalization.For moderate COVID-19 patients, the value of routinely performed CT during the treatment is limited. We recommend avoiding using CT as a routine monitor in moderate COVID-19 patients.


Assuntos
COVID-19/diagnóstico por imagem , Progressão da Doença , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Adolescente , Adulto , Idoso , Proteína C-Reativa/análise , Deterioração Clínica , Feminino , Humanos , Tempo de Internação , Contagem de Leucócitos , Contagem de Linfócitos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Risco , SARS-CoV-2 , Índice de Gravidade de Doença , Tempo para o Tratamento , Adulto Jovem
19.
J Refract Surg ; 37(10): 707-714, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34661478

RESUMO

PURPOSE: To evaluate the differences in efficacy, predictability, safety, and visual quality between topography-guided customized ablation treatment (TCAT) and wavefront-optimized (WFO) laser in situ keratomileusis (LASIK) for the treatment of myopia with and without astigmatism. METHODS: A comprehensive literature search of PubMed, Embase, the Cochrane library, Web of Science, and ClinicalTrials was used to identify randomized controlled trials (RCTs) comparing TCAT-LASIK with WFO-LASIK for myopia with and without astigmatism up to September 2020. The references of all searched literature were checked as supplements. Literature was screened according to the inclusion and exclusion criteria and relative data were extracted. RevMan software version 5.3.0 (Cochrane Collaboration) was used for meta-analysis. RESULTS: A total of seven RCTs (1,168 eyes) were included. There were no statistically significant differences in the ratio of uncorrected distance visual acuity of 20/20 or better (relative risk [RR] = 1.01, 95% CI [0.97 to 1.06], P = .64) and 20/16 or better (RR = 0.96, 95% CI [0.80 to 1.16], P = .69). Compared with WFO-LASIK, TCAT-LASIK achieved a higher proportion of postoperative manifest refractive spherical equivalent within ±0.50 diopters of the target (RR = 1.06, 95% CI [1.02 to 1.11], P = .003) and less surgically induced higher order aberrations (weighted mean difference [WMD] = -0.11, 95% CI [-0.15 to -0.0], P < .00001), spherical aberrations (WMD = -0.04, 95% CI [-0.05 to -0.03], P < .00001), and coma (WMD = -0.15, 95% CI [-0.28 to -0.01], P = .03). No patient lost two or more lines of distance-corrected visual acuity postoperatively in the two groups. CONCLUSIONS: This meta-analysis suggests that both TCATLASIK and WFO-LASIK show excellent efficacy, predictability, and safety for myopia. TCAT-LASIK exhibited more accurate postoperative refraction predictability and less surgically induced higher order aberrations, spherical aberrations, and coma. More randomized, prospective, and large sample-sized studies are needed to confirm these conclusions in the long term. [J Refract Surg. 2021;37(10):707-714.].


Assuntos
Astigmatismo , Aberrações de Frente de Onda da Córnea , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Astigmatismo/cirurgia , Humanos , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Estudos Prospectivos , Resultado do Tratamento
20.
PLoS Med ; 7(11): e1000371, 2010 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-21124891

RESUMO

Jia and colleagues describe how a combination of increased domestic funding, supplemented by foreign loans and donations since 2002, have led to a dramatic increase in tuberculosis case finding in China.


Assuntos
Investimentos em Saúde/organização & administração , Tuberculose/economia , Tuberculose/prevenção & controle , China , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA