1.
Mikrochim Acta ; 190(10): 415, 2023 09 26.
Artigo em Inglês | MEDLINE | ID: mdl-37750999

RESUMO

In recent years, electrochemiluminescence resonance energy transfer (ECL-RET) with low background signal and high specificity has attracted much attention among researchers. Herein, we established a novel ECL-RET biosensor for PML/RARα fusion gene detection. In this ECL-RET system, carbon dots (CDs) with low toxicity and prominent electrochemical activity were used as donor and Au@Ag2S core-shell nanoparticles (Au@Ag2S NPs) were employed as ECL acceptor. The Au@Ag2S NPs possessed a wide ultraviolet-visible (UV-vis) absorption spectrum between 500 nm and 700 nm, which completely overlapped with the ECL spectrum of CDs. Furthermore, the CDs-decorated poly-amidoamine/reduced graphene oxide (CDs/PAMAM/rGO) nanocomposites were prepared to improve the ECL signals and served as a substrate to stably load capture probe deoxyribonucleic acid (DNA). Based on the ECL-RET biosensing strategy, the Au@Ag2S NPs-labeled assistant probes and target DNA could pair with capture probes to form the sandwich-type DNA structure and the distance between donor and accepter was closed, leading to quenching of the ECL signal of CDs. The ECL-RET biosensor represented eminent analytical performance for PML/RARα fusion gene detection with a wide linear relationship from 5 fM to 500 pM and a low detection limit of 0.72 fM, which provided a novel technical means and theoretical basis for detection and diagnosis of acute promyelocytic leukemia.


Assuntos
Nanocompostos , Nanopartículas , Carbono , Transferência de Energia , DNA
2.
Spectrochim Acta A Mol Biomol Spectrosc ; 321: 124730, 2024 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-38943757

RESUMO

Most known chemiluminescence (CL) systems are flash-type that generate weak luminescence and decline quickly after dozens of seconds, while the glow-type CL systems have stable emission for an extended period to achieve accurate quantitation. In this work, a long-term CL system based on hydrazine-hydrate (N2H4·H2O) modified carbon quantum dots (N-CQDs) as a luminescent probe, with K2S2O8 and H2O2 as co-reactants, was proposed. The CL emission enhanced by H2O2 increased 18-fold more than that of N-CQDs and K2S2O8 direct reaction, and decayed by 5% of the maximum intensity over 700 s. In the reaction system, K2S2O8 and H2O2 co-reactants can promote each other to continuously generate corresponding radicals (•OH, O2•-, 1O2), which in turn trigger the CL emission of N-CQDs. This phenomenon was identified as the primary cause for the production of persistent CL. In addition, a stable and selective CL sensor based on the N-CQDs-K2S2O8-H2O2 CL enhancing system was developed for ascorbic acid quantitation in the linear range from 0.1 to 10.0 mM with a detection limit of 0.036 mM. The method has been applied to the analysis of tablet samples and holds potential in pharmaceutical analysis field.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA